Manual Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS

12 pages 0.5 mb
Download

Go to site of 12

Summary
  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 1

    P ACKAGED TERMINAL AIR CONDITIONERS AND HEA T PUMPS ! Ultrahigh efficiency . Up to 12.2 EER. ! Unique component mounting and isolation provide ultraquiet operation and vibration dampening. ! Large well spaced control panel with universal markings and non-removable controls ! Attractive front cover and tamper resistant contoured discharge grille ble ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 2

    2 PERFORMANCE DA TA: Cooling Btuh. Cooling Power (W) EER Heating Btuh COP Dehumidification (Pts/h) Sensible Heat Ratio ELECTRICAL DA TA: V oltage (1 Ph, 60Hz) V oltage Range Current (Amps) (A) P ower Factor Amps L.R Amps F .L. Horsepower AIRFLOW DATA: Indoor CFM V ent CFM PHYSICAL DATA: Dimensions (HxWxD)(In.) Net Weight Shipping Weight R-22 Charge ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 3

    3 Extended Heating Performance PH07 PH09 PH12 Btuh Watts Amps Btuh Watts Amps Btuh Watts Amps Btuh Watts Amps RA TING POINT ARI 310/380 Outdoor Dr y Bulb T emp. ( ° F) 37 42 47 52 57 5366 5663 6400 7053 7789 536 545 568 577 610 2.5 2.6 2.6 2.7 2.8 6005 6399 8100 8647 9245 666 676 742 747 757 3.1 3.1 3.2 3.2 3.3 7799 8611 10800 11383 12349 893 927 ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 4

    4 T ypical Unit Components and Dimensions PXWS W all Sleeve Dimensions: 16" H x 42" W x 13¾" D Series P = Packaged T erminal Unit System X = Accessory E = Cooling with or without electric heat H = Heat Pump with Auxiliary Heat Nominal Cooling Capacity 07 = 7,000 Btuh 09 = 9,000 Btuh 1 2 = 12,000 Btuh 1 5 = 15,000 Btuh Engineering Di ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 5

    5 Note the use of a lintel under the first course of bricks above the wall sleeve. Do not use the wall sleeve as a lintel. The mounting screw holes shown are to be made by the installer . Lintel Installation Lintel Installation Lintel Installation Lintel Installation Lintel Installation Lintel Used T o Support Masonry W alls Smooth side of clip on ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 6

    6 Screw T ube Screw PXDR10 DRAIN KIT Architectural Louver Installation (PXAA) Primary Area: Condensation from the chassis collects in the sleeve in this area. The Primary Area is the preferred installation location. Installation 1. Screw a threaded metal stud into each of the holes at the four corners of the louver . 2. From inside the building, gr ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 7

    7 All units shall be factory assembled, piped, wired and fully charged with R-22. All units shall be certified in accordance with ARI Standard 310 for air conditioners and ARI Standard 380 for heat pumps. Units shall be UL listed and carry a UL label. All units shall be factory run-tested to check operation and be Friedrich WallMaster® or equivale ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 8

    8 New Construction Accessories Friedrich PT AC Accessories MODEL NUMBER DESCRIPTION PHOTO W ALL SLEEVE G-90 zinc coated steel is prepared in an eleven-step process, then powder coated for maximum coverage and protection. The wall sleeve is insulated for thermal efficiency . 16" High x 42" Wide x 13¾" Deep. PXWS DEEP W ALL SLEEVE EXT ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 9

    9 PXSE SLEEVE EXTENSION RETROFIT KIT G-90 zinc coated steel, 2¼" sleeve extension attached to the room side of the sleeve to allow for the installation of a P-Series Friedrich PT AC in a T-Series sleeve. PXDA LA TERAL DUCT EXTENSION A three foot insulated plenum that attaches to the left or right side of the duct adapter . The extension can b ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 10

    10 SA VE THIS CERTIFICA TE. It gives you specific rights, you may also have other rights which may vary from state to state and province to province. In the event that your unit needs servicing, contact your nearest authorized service center . If you do not know the nearest se rvice center, ask the company that installed your unit or contact us - s ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 11

    11 W ALLMASTER ® P-SERIES P ACKAGED TERMINAL AIR CONDITIONERS Purchaser: P .O. # Date: Project: Location: Engineer: Architect: Submitted By: For Approval: For Reference: ITEM PLAN DESIGNA TION QUANTITY COOLING BTU/H V O L T A G E FRIEDRICH MODEL DIMENSIONS Wall Sleeve Overall Depth Width Height Depth Sleeve with Front 42" 16" 13 ¾" ...

  • Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - page 12

    12 Post Office Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4480 ww w .friedrich.com Printed in the U.S.A . PT ACBW02 (04/02) Multiple solutions. One trusted name. F riedrich Air Conditioning Co. ...

Manufacturer Friedrich Category Air Conditioner

Documents that we receive from a manufacturer of a Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS can be divided into several groups. They are, among others:
- Friedrich technical drawings
- PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS manuals
- Friedrich product data sheets
- information booklets
- or energy labels Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS, service manual, brief instructions and user manuals Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS.

Similar manuals

A complete manual for the device Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS.

A complete Friedrich manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS, that we can find in the current document
3. Tips how to use the basic functions of the device Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS - which should help us in our first steps of using Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS?

Use the form below

If you did not solve your problem by using a manual Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS, ask a question using the form below. If a user had a similar problem with Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)