  • Napoleon Fireplaces GT8N - page 1

    1 W415-0619 / B / 03.03.08 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplaces .com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE. GT8N NA TURAL GA ...

  • Napoleon Fireplaces GT8N - page 2

    2 W415-0619 / B / 03.03.08 PG 2-5 INTRODUCTION W arranty General Instructions General Information Care of Glass and Plated Parts Dimensions 5-10 VENTING V enting Lengths and Air T erminal Locations Vent Installations T ypical V ent Installations - Horizontal T ermination T ypical V ent Installations - V ertical T ermination Minimum Air T erminal Lo ...

  • Napoleon Fireplaces GT8N - page 3

    3 W415-0619 / B / 03.03.08 ® ® ® ® ® ® ® ® ® ® ® ®® ® ® ® ® e following ma te rials and workmanship in your new NAPO LEON® gas firepla ce are waanted agains t defects for as long as you own the fireplace.  is covers: combus tion chamber , hea t changer , s tainle s t eel burner , gold pla ted par t s agains t tarn ...

  • Napoleon Fireplaces GT8N - page 4

    4 W415-0619 / B / 03.03.08 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is important to know the speci fi cs that apply to your area, for example: in Massachusetts State: • The fi replace damper must be removed or welded in th ...

  • Napoleon Fireplaces GT8N - page 5

    5 W415-0619 / B / 03.03.08 3 / 4 43 GAS LINE ACCESS ELECTRICAL ACCESS FIGURES 1a-c The glass is 3/16” ceramic glass, available from your Napoleon® / Wolf Steel Ltd. dealer . Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace glass cleaner . Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! Do not ...

  • Napoleon Fireplaces GT8N - page 6

    6 W415-0619 / B / 03.03.08 For safe and proper operation of the fi replace follow the venting instruction exactly . Deviation from the minimum or the maximum vertical vent length can create dif fi culty in burner start-up and/or carboning. Under extreme vent con fi gurations, allow several minutes (5-15) for the fl ame to stabilize after igniti ...

  • Napoleon Fireplaces GT8N - page 7

    7 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - HORIZONT AL TERMINA TION MIN MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) N/A 1 Rise per foot (recommended) 1/4” N/A Rise per foot (allowable) 0” N/A Horizontal run (If vent run does not include vertical rise) 4” 24” 2a Horizontal ru ...

  • Napoleon Fireplaces GT8N - page 8

    8 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - VERTICAL TERMINA TION 24” MIN. MINIMUM VERITICAL 4” MIN. FIGURE 3a 24” MIN. MINIMUM VERITICAL MAXIMUM HORIZONT AL 5 FT MAX. 15 FT MAX. 4” MIN. MAXIMUM VERTICAL 19 1/2 FT MAX. 4” MIN. MIN MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) ...

  • Napoleon Fireplaces GT8N - page 9

    9 W415-0619 / B / 03.03.08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL L OCA TION CLEARANCES N D E O FIGURE 4 ...

  • Napoleon Fireplaces GT8N - page 10

    10 W415-0619 / B / 03.03.08 INST ALLA TION / FRAMING WALL AND CEILING PRO TECTION This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square opening of 8” wide x 8” high. 1. Apply a bead of caulking all around and place the fi restop ...

  • Napoleon Fireplaces GT8N - page 11

    11 W415-0619 / B / 03.03.08 1. Stretch the 3” fl exible vent pipe to the required length taking into account the additional length needed for the fi nished wall surface. Apply a heavy bead of the high temperature sealant W573-0007 (not supplied). Slip the fl exible vent pipe a minimum of 2” over the inner sleeve of the air terminal and secur ...

  • Napoleon Fireplaces GT8N - page 12

    12 W415-0619 / B / 03.03.08 HIGH TEMPERA TURE SEALANT 1 1 / 2 ” OVERLAP SCREWS 1. Install the 3” fl exible vent pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using Mill Pac sealant (W573-0007 not supplied). 2. Install the 5” fl exible vent pipe to the fi replace. Attach and seal the joints ...

  • Napoleon Fireplaces GT8N - page 13

    13 W415-0619 / B / 03.03.08 Do NOT use the fireplace if any part has been under water . Call a qualified service technician IMMEDIA TEL Y to have the fi replace inspected for damage to the electrical circuit. IT IS NECESSAR Y T O HARD WIRE THIS FIREPLACE. Permanently framing the fi replace with an enclosure, requires the fireplace junction box to ...

  • Napoleon Fireplaces GT8N - page 14

    14 W415-0619 / B / 03.03.08 FRAMING FIGURES 21a,b&c NAILING T AB INST ALLA TION Attach the 4 nailing tabs supplied to the sides of the outer shell as illustrated using the 8 self-tapping screws included in the manual baggie. FIGURE 20 The has been designed to be installed mid-way up a wall. When installing this unit close to the fi nished fl ...

  • Napoleon Fireplaces GT8N - page 15

    15 W415-0619 / B / 03.03.08 2” MIN.* 12” MIN. TO COMBUSTIBLES (to ceiling or mantle) 1 1 / 2 ” MIN. * Any protruding finishing material installed in this space (ie. baseboards) must leave 2” of unobstructed clearance to allow for full rotation of the control door . COMBUSTIBLE NON-COMBUSTIBLE 1” 1” 0” IF NON-COMBUSTIBL E FINISHING IS ...

  • Napoleon Fireplaces GT8N - page 16

    16 W415-0619 / B / 03.03.08 FIGURE 28 RECEIVING SLOTS DOOR STOP CHAIN FRAME/FRONT INST ALLA TION 1. Align the two holes in the upper portion of the hinge on the control door to those in the bottom trim bracket, secure using two of the #8 x 1/2” hex head screws supplied. Figure 26 2. Install the top trim bracket to the fi rebox using the three #9 ...

  • Napoleon Fireplaces GT8N - page 17

    17 W415-0619 / B / 03.03.08 LK8 LIGHT INST ALLA TION (OPTIONAL) 1 . T urn off the electrical and gas supply to the fi replace. 2 . Remove the frame from the unit by removing the 2 black securing screws from the top, and the 2 silver hex head securing screws from the bottom. 3 . Lay the frame down on its front, being careful not to scratch the fi ...

  • Napoleon Fireplaces GT8N - page 18

    18 W415-0619 / B / 03.03.08 A. This fi replace is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Do not use this fi replace if an ...

  • Napoleon Fireplaces GT8N - page 19

    19 W415-0619 / B / 03.03.08 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame color to be established. NOTE: It ...

  • Napoleon Fireplaces GT8N - page 20

    20 W415-0619 / B / 03.03.08 # P ART NO. DESCRIPTION 1 W225-0216 DOOR FRAME 2* W562-0008 DOOR GASKET 3* W010-1736 DOOR LA TCH ASSEMBL Y 4 W010-1743 GLASS C / W GASKET 5* W300-0088 GLASS 6 W100-0104 BURNER 7 W357-0006 IGNITOR 8 W190-0026 CONTROL, MODULE 9* W750-0183 WIRE HARNESS 10* W750-0184 IGNITION CABLE 1 1 W200-0234 IGNITOR COVER 12 W200-0233 BU ...

  • Napoleon Fireplaces GT8N - page 21

    21 W415-0619 / B / 03.03.08 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, burner ignites, electrode continues to spark for complete 7 seconds, burner shuts down. Hot and neutral wires are re ...

  • Napoleon Fireplaces GT8N - page 22

    22 W415-0619 / B / 03.03.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

Manufacturer Napoleon Fireplaces Category Indoor Fireplace

Documents that we receive from a manufacturer of a Napoleon Fireplaces GT8N can be divided into several groups. They are, among others:
- Napoleon Fireplaces technical drawings
- GT8N manuals
- Napoleon Fireplaces product data sheets
- information booklets
- or energy labels Napoleon Fireplaces GT8N
All of them are important, but the most important information from the point of view of use of the device are in the user manual Napoleon Fireplaces GT8N.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Napoleon Fireplaces GT8N, service manual, brief instructions and user manuals Napoleon Fireplaces GT8N. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Napoleon Fireplaces GT8N.

A complete manual for the device Napoleon Fireplaces GT8N, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Napoleon Fireplaces GT8N by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Napoleon Fireplaces GT8N.

A complete Napoleon Fireplaces manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Napoleon Fireplaces GT8N - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Napoleon Fireplaces GT8N, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Napoleon Fireplaces GT8N, that we can find in the current document
3. Tips how to use the basic functions of the device Napoleon Fireplaces GT8N - which should help us in our first steps of using Napoleon Fireplaces GT8N
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Napoleon Fireplaces GT8N
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Napoleon Fireplaces GT8N in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Napoleon Fireplaces GT8N?

Use the form below

If you did not solve your problem by using a manual Napoleon Fireplaces GT8N, ask a question using the form below. If a user had a similar problem with Napoleon Fireplaces GT8N it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)