Manual Omron INTELLI SENSE HEM-711AC

38 pages 1.44 mb
Download

Go to site of 38

Summary
  • Omron INTELLI SENSE HEM-711AC - page 1

    A utomatic Blood P ressur e Monitor with Arm C uff Model HEM-711A C INSTRUCTION MANUAL ESP AÑOL ENGLISH 280239_HEM-7011-E_S.qxd 2/19/08 3:00 PM Page 1 ...

  • Omron INTELLI SENSE HEM-711AC - page 2

    Bef or e Using the Monitor Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Operating the De vice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Ri ...

  • Omron INTELLI SENSE HEM-711AC - page 3

    Thank you for purchasing the Omron ® HEM-711A C IntelliSense ® Automatic Blood Pressure Monitor with Arm Cuf f. INTRODUCTION 3 F ill in for future reference . DA TE PURCHASED: __________________ SERIAL NUMBER: ____________________ Staple your pur chase receipt here Y our ne w digital blood pressure monitor uses the oscillometric method of blood p ...

  • Omron INTELLI SENSE HEM-711AC - page 4

    T o assur e the corr ect use of the pr oduct basic saf ety measur es should alw ays be f ollo wed inc luding the warnings and cautions listed in this instruction manual. W ARNING Indicates a potentially hazardous situation which, if not a v oided, could result in death or serious injury . SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL CA UTION Indi ...

  • Omron INTELLI SENSE HEM-711AC - page 5

    5 OPERA TING THE DEVICE (continued) Read the Special Conditions section (page 27) of the instruction manual if your systolic pressure is kno wn to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuf f is applied. Operate the de vice only as intended. Do not use the de vice for any other purpose. ...

  • Omron INTELLI SENSE HEM-711AC - page 6

    CARE AND MAINTENANCE Do not subject the monitor to strong shocks such as dropping the unit on the floor . Do not submer ge the de vice or any of the components in w ater . Store the de vice and the components in a clean, safe location. Changes or modif ication not approv ed by Omron Healthcare will v oid the user warranty . Do not disassemble or at ...

  • Omron INTELLI SENSE HEM-711AC - page 7

    Opera ting Instruc tions 7 BEFORE T AKING A MEASUREMENT T o ensure a reliable reading follow these recommendations: 1. A v oid eating, drinking alcohol, smoking, ex ercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. A v oid taking measurement ...

  • Omron INTELLI SENSE HEM-711AC - page 8

    8 Air Jack Main Unit: Batter y Compar tment ST ART/STOP Button MEMOR Y Button Date/Time Setting Button Display AC Adapter Jack Components: Air T ube Air Plug (Connects to Air Jack) Arm Cuf f Storage Case AC Adapter KNOW Y OUR UNIT INSTRUCTION MANUAL ESP ESPAÑOL ENGLISH Automatic Blood Pressure Monitor with Arm Cuff Model HEM-711AC Instruction Manu ...

  • Omron INTELLI SENSE HEM-711AC - page 9

    9 UNIT DISPLA Y Diastolic Blood P ressure Systolic Blood P ressure Memor y Symbol Pulse Displa y Date/Time Display Lo w Batter y Indicator A verage V alue Symbol Hear tbeat Symbol/ Hyper tension Indicator Deflation Symbol Irregular Heartbeat Symbol Mov ement Error Symbol 280239_HEM-7011-E_S.qxd 2/19/08 3:00 PM Page 9 ...

  • Omron INTELLI SENSE HEM-711AC - page 10

    IRREGULAR HEAR TBEA T SYMBOL ( ) When the monitor detects an irre gular rhythm two or more times during the measurement, the Irre gular Heartbeat Symbol ( ) will appear on the display with the measurement v alues. An irre gular heartbeat rhythm is defined as a rhythm that is more than 25% slo wer or 25% faster than the a verage rhythm detected whil ...

  • Omron INTELLI SENSE HEM-711AC - page 11

    11 The American Heart Association recommends the follo wing guideline for upper limit of normal for home blood pressure readings: AHA Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on age and morbidity . The AHA recommends a low ...

  • Omron INTELLI SENSE HEM-711AC - page 12

    HEAR TBEA T SYMBOL/HYPER TENSION INDICA T OR ( ) T AKING A MEASUREMENT The Heartbeat Symbol flashes on the display during the measurement. The Heartbeat Symbol flashes at e v ery heartbeat. When the measurement is complete, the Heartbeat Symbol flashes on the display with your blood pressure and pulse rate if the reading is abo ve 135 for the Systo ...

  • Omron INTELLI SENSE HEM-711AC - page 13

    13 1. Press the ▼ indicator on the battery co ver and slide the co ver of f in the direction of the arro w . 2. Install 4 “ AA” size batteries so the + (positi v e) and - (negati ve) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery co ver . BA T TER Y INST ALLA TION Battery Cov er 280239_HEM-7011 ...

  • Omron INTELLI SENSE HEM-711AC - page 14

    BA TTER Y REPLACEMENT When the Lo w Battery Indicator appears on the display screen turn the monitor of f and remo ve all the batteries. Replace with four ne w batteries at the same time. Longlife alkaline batteries are recommended. CA UTION If battery fluid should get in your e yes, immediately rinse with plenty of clean water . Contact a physicia ...

  • Omron INTELLI SENSE HEM-711AC - page 15

    15 NO TES: • Use only the authorized Omron A C Adapter that came with this monitor . • W e recommend you install the batteries ev en if the A C Adapter is used. If no batteries are installed, you may need to reset the date and time if the A C Adapter is disconnected. The measurement results will not be deleted. CA UTION Use only Omron authorize ...

  • Omron INTELLI SENSE HEM-711AC - page 16

    T O CONNECT THE AC ADAPTER Insert the A C Adapter Plug into the A C Adapter Jack on the back side of the monitor as illustrated. Plug the A C Adapter into a 120V A C outlet (60 cycles). T O DISCONNECT THE AC ADAPTER Hold and pull the Housing to remo ve the A C Adapter from the electrical outlet. Do not remo ve by pulling on the cord. Remo ve the A ...

  • Omron INTELLI SENSE HEM-711AC - page 17

    17 Set the monitor to the current date and time before taking a measurement for the f irst time. If the date and time are not set correctly , the measurement v alues stored in the memory and the a verage v alues may not be correct. The Blood Pressure Monitor automatically stores up to 60 indi vidual measurement v alues with the dates and times. The ...

  • Omron INTELLI SENSE HEM-711AC - page 18

    SET TING THE DA TE AND TIME 2 . SETTING THE YEAR The year can be set between 2006 and 2030. When the display reaches 2030, it will return to 2006. Press the MEMOR Y b utton to adv ance by increments of one year . Press the Date/T ime Setting button to set the current year . The month flashes on the display . NO TE: Press and hold the MEMOR Y b utto ...

  • Omron INTELLI SENSE HEM-711AC - page 19

    19 4. SETTING THE D A Y Press the MEMOR Y b utton to adv ance by increments of one day . Press the Date/T ime Setting button to set the current day . The hour flashes on the display . 5. SETTING THE HOUR The time is set using AM or PM. Press the MEMOR Y b utton to adv ance by increments of one hour . Press the Date/T ime Setting button to set the c ...

  • Omron INTELLI SENSE HEM-711AC - page 20

    RESETTING THE DA TE AND TIME T o adjust the date or time after it has been setup when you first use the unit: Start with the monitor in the of f position. 1. Press and hold the Date/T ime Setting b utton. The year flashes on the display . 2. Follo w the instruction from step 2 on page 18. NO TE : If you need to change the Date and T ime, alw ays ad ...

  • Omron INTELLI SENSE HEM-711AC - page 21

    21 CA UTION Read all of the information in the instruction manual and an y other literature in the box before operating the unit. CA UTION This de vice is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this de vice on infants or persons who cannot e xpress their intentions. APPL YING THE CUFF ON THE ...

  • Omron INTELLI SENSE HEM-711AC - page 22

    3. Apply the cuf f to your left upper arm so the blue arro w is centered on the inside of your arm and aligned with your middle f inger . The air tube runs do wn the inside of your arm. The bottom of the cuf f should be approximately 1/2" abo ve your elbo w . 4. Wrap the cuff f irmly in place around your arm using the closure strip. APPL YING ...

  • Omron INTELLI SENSE HEM-711AC - page 23

    23 APPL YING THE ARM CUFF APPL YING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 4 on page 22. Apply the cuf f to your right upper arm so the blue arro w and the air tube runs along the inside of your elbo w . The bottom of the cuf f should be approximately 1/2'' abo ve your elbo w ...

  • Omron INTELLI SENSE HEM-711AC - page 24

    T AKING A MEASUREMENT 24 The monitor automatically determines your ideal inflation le v el. In rare circumstances when a higher inflation may be necessary , the monitor automatically re-inflates the cuf f up to 30 mmHg higher than the initial inflation and restarts the measurement. CA UTION Operate the de vice only as intended. Do not use the de vi ...

  • Omron INTELLI SENSE HEM-711AC - page 25

    2. Press the ST AR T/ST OP button. All symbols appear on the display . The cuf f starts to inflate automatically . As the cuf f inflates, the monitor automatically determines your ideal inflation le v el. This monitor detects the pulse during inflation. Do not mo ve your arm and remain still until the entire measurement process is completed. NO TE ...

  • Omron INTELLI SENSE HEM-711AC - page 26

    26 T AKING A MEASUREMENT 4. When the measurement is complete, the arm cuff completely deflates. Y our blood pressure and pulse rate are displayed. 5. Press the ST AR T/ST OP button to turn the monitor of f. NO TE : The monitor will automatically turn of f after f i v e minutes. When the measurement is complete, the Heartbeat Symbol flashes on the d ...

  • Omron INTELLI SENSE HEM-711AC - page 27

    27 T AKING A MEASUREMENT SPECIAL CONDITIONS CA UTION Inflating to a higher pressure than necessary may result in bruising where the cuf f is applied. If your systolic pressure is kno wn to be more than 220 mmHg, press and hold the ST AR T/ST OP button until the monitor inflates 30 to 40 mmHg higher than your e xpected systolic pressure. NO TES: • ...

  • Omron INTELLI SENSE HEM-711AC - page 28

    28 The monitor is designed to store the blood pressure and the pulse rate in the memory e v ery time a measurement is completed. The monitor automatically stores up to 60 sets of measurement v alues (blood pressure and pulse rate). When 60 sets of measurement values are stored, the oldest record is deleted to sa ve the most recent v alues. A VERAGI ...

  • Omron INTELLI SENSE HEM-711AC - page 29

    USING THE MEMOR Y FUNCTION 29 2. Press the MEMOR Y b utton to display the most recent set of measurement v alues on the screen. The v alues are displayed from the most recent to the oldest. NO TES: • The date and time are alternately displayed with the measurement v alues. • Press the MEMOR Y b utton to display the next set of v alues. • Pres ...

  • Omron INTELLI SENSE HEM-711AC - page 30

    Car e and Maintenance 30 USING THE MEMOR Y FUNCTION T O DELETE ALL V ALUES STORED IN THE MEMOR Y Y ou cannot partially delete v alues stored in the memory . All v alues will be deleted. 1. First press the MEMOR Y b utton. While holding it do wn, press the ST AR T/ST OP button together for more than 2 seconds. All v alues will be deleted. 2. Press t ...

  • Omron INTELLI SENSE HEM-711AC - page 31

    T o keep your digital b lood pr essur e monitor in the best condition and pr otect the unit fr om dama ge, f ollo w the dir ections listed belo w: K eep the monitor in the storag e case when not in use. Make sure the A C Adapter is placed under the main unit so that is does not damage the display . A v oid kinking or sharply bending the A C Adapter ...

  • Omron INTELLI SENSE HEM-711AC - page 32

    32 C ARE AND MAINTENANCE Remo v e the batteries if the unit will not be used for three months or longer . Al ways replace all the batteries with ne w ones at the same time. Use the unit consistent with the instruction pr o vided in this manual. CA UTION Changes or modif ication not approv ed by Omron Healthcare will v oid the user warranty . Do not ...

  • Omron INTELLI SENSE HEM-711AC - page 33

    SYMBOL CA USE C ORRECTION Cuf f under -inflated. Cuf f not applied correctly . Remo ve the arm cuf f. Read, “T aking a Measurement”. Reapply the arm cuf f and take another measurement. Cuf f o ver -inflated T ake another measurement and remain still until the measurement is complete. Monitor could not detect pulse wa ve. Air plug is not connect ...

  • Omron INTELLI SENSE HEM-711AC - page 34

    34 ERROR INDIC A T ORS AND TROUBLESHOO TING TIPS PROBLEM CA USES AND SOL UTIONS No po wer . No display appears on the unit. Replace all four batteries with ne w ones. Check the battery installation for proper placement of the battery polarities. Measurement v alues appear too high or too lo w . Blood pressure v aries constantly . Man y factors incl ...

  • Omron INTELLI SENSE HEM-711AC - page 35

    FC C ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital de vice, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product ...

  • Omron INTELLI SENSE HEM-711AC - page 36

    36 W ARR ANT Y Y our HEM-711A C IntelliSense ® Automatic Blood Pressure Monitor , excluding the arm cuf f, is warranted to be free from defects in materials and w orkmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor . The arm cuf f is warranted to be free from defect ...

  • Omron INTELLI SENSE HEM-711AC - page 37

    Model: HEM-71 1AC Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release v alve Rapid Air Release: Automatic exhaust v alve Pressure Detection: Capaciti v ...

  • Omron INTELLI SENSE HEM-711AC - page 38

    Manufactured by OMR ON HEAL THCARE Made in China Distrib uted by: OMR ON HEAL THCARE, INC. 1200 Lakeside Dri ve Bannockb urn, Illinois 60015 www .omronhealthcare.com Copyright © 2008 Omron Healthcare, Inc. 280239_HEM-7011-E_S.qxd 2/19/08 3:00 PM Page 38 ...

Manufacturer Omron Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Omron INTELLI SENSE HEM-711AC can be divided into several groups. They are, among others:
- Omron technical drawings
- INTELLI SENSE HEM-711AC manuals
- Omron product data sheets
- information booklets
- or energy labels Omron INTELLI SENSE HEM-711AC
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron INTELLI SENSE HEM-711AC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron INTELLI SENSE HEM-711AC, service manual, brief instructions and user manuals Omron INTELLI SENSE HEM-711AC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron INTELLI SENSE HEM-711AC.

A complete manual for the device Omron INTELLI SENSE HEM-711AC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron INTELLI SENSE HEM-711AC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron INTELLI SENSE HEM-711AC.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron INTELLI SENSE HEM-711AC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron INTELLI SENSE HEM-711AC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron INTELLI SENSE HEM-711AC, that we can find in the current document
3. Tips how to use the basic functions of the device Omron INTELLI SENSE HEM-711AC - which should help us in our first steps of using Omron INTELLI SENSE HEM-711AC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron INTELLI SENSE HEM-711AC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron INTELLI SENSE HEM-711AC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron INTELLI SENSE HEM-711AC?

Use the form below

If you did not solve your problem by using a manual Omron INTELLI SENSE HEM-711AC, ask a question using the form below. If a user had a similar problem with Omron INTELLI SENSE HEM-711AC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)