Manual Friedrich CP06F10

29 pages 1.88 mb
Download

Go to site of 29

Summary
  • Friedrich CP06F10 - page 1

    Room Air Conditioner Service and P ar ts Man ual CP 06 - CP 08 S vc P ar ts 2010 ( 05 / 10) C P 06F1 0 CP08F1 0 0 F Power Mode Timer 0 n / 0ff Fan Speed Temp Cool Money Saver ® Fan Only Dry hr Auto Swing 115Volts ...

  • Friedrich CP06F10 - page 2

    Air Conditioner Ser vice Man ual T ABLE OF CONTENTS Safety Precautions ............................................................................................................................... ...........3 Dimensions ............................................................................................................................... ...

  • Friedrich CP06F10 - page 3

    Ser vice Man ual 3 Saf ety Precautions Safety Precautions T o pre vent injury to the user or other people and proper ty damage, the f ollowing instructions must be f ollow ed. Incorrect operation due to ignoring instr uctions will cause harm or damage. The seriousness is classified b y the f ollowing indications. Meanings of symbols used in this ma ...

  • Friedrich CP06F10 - page 4

    4 Room Air Conditioner Saf ety Precautions Plug in the power plug properl y . • Otherwise , it will cause electric shock or fire. Do not operate or stop the unit b y inserting or pulling out the power plug. • It will cause electric shock or fire. Do not damage or use an unspecified power cor d. • It will cause electric shock or fire. Do not u ...

  • Friedrich CP06F10 - page 5

    Ser vice Man ual 5 Saf ety Precautions CAUTION • • • • • If water enters the pr oduct, turn off the the power s witch of the main body of appliance. Contact service center after taking the power - plug out from the soc ket. • It will cause electric shock or f ailure of machine. Do not clean the air conditioner with water . • W ater ma ...

  • Friedrich CP06F10 - page 6

    6 Room Air Conditioner Dimensions Dimensions Outside Dimensions This symbol alerts you to the risk of electric shoc k. This symbol alerts you to hazar ds that could cause harm to the air conditioner . This symbol indicates special notes. NOTICE Symbols Used in this Manual 353(13 7 / 8 ") 470(18 1 / 2 ") 525(20 11 / 16 ") ...

  • Friedrich CP06F10 - page 7

    1Ø, 115, 60Hz * * ) B W ( 7 6 * ) B D ( 80 ) 。 ( R O O D N I F 。 F ) ( R O O D T U O 345g(12.2 oz) Ø7 .0, 2ROW 14 STA CKS Ø5 .0, 2ROW 16STA CKS TU RBO FAN PROPELLER TY PE FAN WITH SLINGER RING 3/3 6 POLES REMOTE CONTROLLER THERMISTOR HORIZONTAL LO UVER (UP & DOWN), VER TICAL LOUVER (RIGHT &LEFT) SLIDE IN-OUT CH AS SIS R O T C E T O R ...

  • Friedrich CP06F10 - page 8

    Ai r Pu r i f i e r Pow er Temp Mod e Ti me r A Sw i n g Fan Spe ed 1 2 4 3 5 Auto Swing 6 0 F P ower Mode Timer 0n / 0f f Fa n Speed T emp Cool Money Saver ® Fan Only Dry hr Auto Swing 1 3 2 4 6 5 7 6. A UT O SWING This button can automatically control the air flo w direction. 7 T o receive the signal from remote controller. dry operation. (dehum ...

  • Friedrich CP06F10 - page 9

    Disassembly Disassembl y Mechanical Parts — Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord. 1. FRONT GRILLE 1. Open the lnlet grille upward or downward. 2. Remove the screw which fastens the front grille. 3. Pull the front grille from the right side. 4. Remove the front grille. 5. Re-install the component ...

  • Friedrich CP06F10 - page 10

    1 0 Room Air Conditioner Disassembly Air Handling P ar ts 1 . AIR GUIDE AND BLO WER 1. Remove the front grille. 2. Remove the cabinet. 3. Remove the control box. 4. Remove the 3 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the evaporator. 7. Move the evaporator forward and pulling it upward slightly. (See ...

  • Friedrich CP06F10 - page 11

    Se r vice Ma n ual 1 1 Electrical P ar ts 1. Remove the cabinet. 2. Remove the evaporator. 3. Remove the orifice. 4. Remove the blower. 5. Remove the fan. 6. Remove the control box cover and housing of the motor in the control box. 7. Remove the 2 screws which fasten the motor from th e moun t motor . (Se e Figur e 7 ) 8. Remove the motor. 9. Re-in ...

  • Friedrich CP06F10 - page 12

    3. CA P A CI T OR 1 2 Room Air Conditioner 1. Remove the control box. 2. Remove the screw which fasten control panel from control box. 3. Remove the screw which located in the front. 4. Open the bottom side of control box. 5. Remove the screw and the clamp which fastens the capacitor. 6. Disconnect all the leads of capacitor terminals. 7. Re-instal ...

  • Friedrich CP06F10 - page 13

    13 Room Air Conditioner Disassembly — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM . Leave the valve in place after se ...

  • Friedrich CP06F10 - page 14

    Se r vice Ma n ual 14 Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SID ...

  • Friedrich CP06F10 - page 15

    Schematic Diagr am Cir cuit Diagram LOCATION NO. 1 2 3 4 5 6 7 8 Q'TY PER SET 1 1 1 1 1 1 1 1 DESCRIPTION POWER CORD ASSEMBLY FAN MOTOR COMPRESSOR DISPLAY P.W.B ASSEMBLY MAIN P.W.B ASSEMBLY THERMISTOR CAPACITOR OWERLOAD PROTECTOR (SMPS) 250V/T2A (250V/T3.15A) MEZ62420707 WH (BL) 15 Room Air Conditioner ...

  • Friedrich CP06F10 - page 16

    Electr onic Control De vice Schematic Diagram Se r vice Ma n ua l 16 ...

  • Friedrich CP06F10 - page 17

    T roubleshooting Guide T r oubleshooting Guide Piping System Figure 1 6 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle. MOTOR COMPRESSOR OIL (LIQUID REFRIGERANT) CAPILLARY T ...

  • Friedrich CP06F10 - page 18

    T roubleshooting Guide T roub leshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but poor cooling. Ineffective Cooling ...

  • Friedrich CP06F10 - page 19

    T roubleshooting Guide Fails to Start Improper thermistor setting Loose terminal connection Improper wiring Check of power source. Drop of power voltage. Capacitor check. Replacement. Check of control panel setting. Compressor fails only to start. Defect of compressor capacitor. Replacement of compressor (Motor damaged). Irregular motor insulation ...

  • Friedrich CP06F10 - page 20

    T roubleshooting Guide ELECTRIC P AR TS TR OUBLESHOO TING GUIDE: P ossible T rouble 1 • The unit does not operate. Is the Trans input power AC 115V? Is the Trans output power about AC 14V? Is shorted the Trans. output? Is output Voltage of IC01D DC 12V? Is output Voltage of IC02D DC 5V? Is the voltage No.18 of Micom DC 5V? Exchange Main P.W.B Ass ...

  • Friedrich CP06F10 - page 21

    T roubleshooting Guide Is Temp. setting set lower than Room Temp.-0.5 ° C? Is the voltage No.10 of IC01M 0V? • Exchange IC01M. • Set the Temp. setting to lower Temp. • Wait 3 Minutes Is the Unit for 3 minutes delay? • Exchange MAIN P.W.B Ass'y. Is the voltage N0.7 of IC01M DC 5V? • Check the RY-COMP. • Check the wiring Diagram. NO ...

  • Friedrich CP06F10 - page 22

    T roubleshooting Guide Is the voltage of Battery about over 2.3V? • Exchange Receiver Ass'y. Is the connection of CN-DISP1 all right? Is the voltage No.16 of CN-DISP1 on Main P.W.B Ass'y DC 5V? • Exchange the battery. • Check the P.W.B pattern. • Connect connector to CN-DISP1 exactly. NO NO NO YES YES YES P ossible T rouble 5 • ...

  • Friedrich CP06F10 - page 23

    T roubleshooting Guide ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V Y D E M E R E S U A C T N I A L P M O C Fan motor will not run. No power Check voltage at outlet. Correct if none. Wire disconnected or Connect wire. Refer to wiring diagram for connection loose terminal identification. Repair or r ...

  • Friedrich CP06F10 - page 24

    T roubleshooting Guide Y D E M E R E S U A C T N I A L P M O C , g n i s s i m y l l a i t r a p r o , e c n a l a b f o t u o , d e k c a r c f I n a F . e s i o n r o t o m n a F replace it. , g n i s s i m y l l a i t r a p r o , e c n a l a b f o t u o , d e k c a r c f I r e w o l B replace it. Loose set screw Tighten it. Worn bearings If knoc ...

  • Friedrich CP06F10 - page 25

    COMPLAINT CAUSE REMEDY Compressor cycles on Voltage Check the voltage. See the limits on the overload. preceding page. If voltage is not within these limits, call an electrician. Overload Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.) Compressor cycles on Fan m ...

  • Friedrich CP06F10 - page 26

    Exploded Vie w Exploded Vie w 249950 268711-1 264110 238310 237200 268711-2 135500 146812 W0CZZ 359011 731273 267110 135303 749740 352380 152302 148000 130910 34681 1 349600 W48602 149980 359012 349480 147581 135312 130410 567502 550140 349001 147582 567480 552113 Se r vice Ma n ua l 26 ...

  • Friedrich CP06F10 - page 27

    LocNo DESCRIPT ION CP06F10 130410 Base Ass embly,Single 67302912 130910 Cabinet Assem bly ,Single 67303714 135303 Grille,Inlet 67306114 135312 Grille As sembly,Front(Indoor) 67306017 135500 Cover 67400148 146812 Motor,AC 67300902 147581 Louver,Horizontal 67306208 147582 Louver,Vertical 67306264 148000 Supporter 67303901 149980 Shroud 67303108 15230 ...

  • Friedrich CP06F10 - page 28

    Replacement Parts list LocNo DESCRIPTIO N CP08F10 130410 Base Ass e mbly ,Single 67302917 130910 Cabinet Assem bly ,Single 67303714 135303 Grille,Inlet 67306114 135312 Grille Ass embly,Front(Indoor) 67306017 135500 Cover 67400148 146812 Motor,AC 67300902 147581 Louver,Horizontal 67306208 147582 Louver,Vertical 67306264 148000 Supporter 67303901 149 ...

  • Friedrich CP06F10 - page 29

    Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com Use F actor y Cer tified P ar ts... CP 06 - CP 08 S vc P ar ts 2010 ( 05 / 10) ...

Manufacturer Friedrich Category Air Conditioner

Documents that we receive from a manufacturer of a Friedrich CP06F10 can be divided into several groups. They are, among others:
- Friedrich technical drawings
- CP06F10 manuals
- Friedrich product data sheets
- information booklets
- or energy labels Friedrich CP06F10
All of them are important, but the most important information from the point of view of use of the device are in the user manual Friedrich CP06F10.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Friedrich CP06F10, service manual, brief instructions and user manuals Friedrich CP06F10. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Friedrich CP06F10.

Similar manuals

A complete manual for the device Friedrich CP06F10, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Friedrich CP06F10 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Friedrich CP06F10.

A complete Friedrich manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Friedrich CP06F10 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Friedrich CP06F10, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Friedrich CP06F10, that we can find in the current document
3. Tips how to use the basic functions of the device Friedrich CP06F10 - which should help us in our first steps of using Friedrich CP06F10
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Friedrich CP06F10
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Friedrich CP06F10 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Friedrich CP06F10?

Use the form below

If you did not solve your problem by using a manual Friedrich CP06F10, ask a question using the form below. If a user had a similar problem with Friedrich CP06F10 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)