    Operating Manual Internal GPIB Interface for XHR/XFR Series Programmable DC Power Supplies GPIB-XHR GPIB-XFR GPIB-XFR3 ...

  • Xantrex XHR, XFR, XFR3 - page 2

    ...

  • Xantrex XHR, XFR, XFR3 - page 3

    Operating Manual for Internal GPIB Interface for XHR 1000 Watt Series, XFR 1200 Watt Series and XFR 2800 Watt Series Programmable DC Power Supplies ...

  • Xantrex XHR, XFR, XFR3 - page 4

    ii Operating Manual for GPIB for XHR/XFR Series Power Supply Limited W arranty What does this warranty cover and how long do es it last? This Limited W arranty is pro vided by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your GPIB Interfac e Card . This warranty lasts for a W arranty Period of 5 year ...

  • Xantrex XHR, XFR, XFR3 - page 5

    Release 3.1 iii Direct returns may be performed accordi ng to the Xantrex Return Material Authorization Policy describ ed in your pr oduct manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantre x or check our website to see if your product can be repaired at one of these facilities. In any warrant ...

  • Xantrex XHR, XFR, XFR3 - page 6

    iv Operating Manual for GPIB for XHR/XFR Series Power Supply Disclaimer Product THIS LIMITED W ARRANTY IS THE SOLE AND EXCLUSIVE W ARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YO UR XANTREX PRODUCT AND IS, WHERE PERMIT TED BY LA W , IN LIEU OF ALL OTHER W ARRANT IES, CONDITIONS, GUARANTEES, REPRESENT A TIONS, OBLI GA TIONS AND LIABILITIES, EXPRES ...

  • Xantrex XHR, XFR, XFR3 - page 7

    Release 3.1 v Information WITHOUT LIMITING THE GENERA LITY OF THE FOREGOING, UNLESS SPECIFICALL Y AGREED T O BY IT IN WRI TING, XANTREX a. MAKES NO W ARRANTY AS TO THE ACCU RACY , SUFFICIENCY OR SUIT ABILITY OF ANY TECHNICAL OR O THER INFORMA TION PROVIDED IN MANUALS OR O THER DOCUMENT A TION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT ; AND b. A ...

  • Xantrex XHR, XFR, XFR3 - page 8

    vi Operating Manual for GPIB for XHR/XFR Ser ies Power Supply Power Supply Safety W arnings, Cautions, and Notes W arnings, cautions, and notes are defined and formatted in this manual as shown below . W ARNING—High Ener gy and High V olt age Exercise caution when using and calibrating a power supply . High energy levels can be stored at the outp ...

  • Xantrex XHR, XFR, XFR3 - page 9

    Release 3.1 vii About This Manual This technical manual is for the internal GPIB interface, a microprocessor-controlled option card for XHR Series and XFR Series DC output power supplies. T his manual provides you with descriptions and specifi cations, user options, and configuration instructions, in addition to a co mmand set which enables you to ...

  • Xantrex XHR, XFR, XFR3 - page 10

    About This Manu al viii Operating Manual for GPIB for XHR/XFR Series Power Supply ...

  • Xantrex XHR, XFR, XFR3 - page 11

    Release 3.1 ix Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Section 1. Features and Specificati ons Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Features and Functions . . . . . ...

  • Xantrex XHR, XFR, XFR3 - page 12

    Content s x Operating Manual for GPIB for XHR/XFR Series Power Supply Command Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Accumulated Status, Status, and Fault R egisters . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Error Codes . . . . . . . . . . . . . . . . . . . . . . ...

  • Xantrex XHR, XFR, XFR3 - page 13

    Release 3.1 11 Section 1. Features and S pecifications Description The internal GPIB interface card allows you to operate your power supply from a computer controller via the IEEE-488 commun ications bus. See Figure 1.1, “Sample Configuration using GPIB Interface”. The GPIB interface allows co mplete remote programmin g of your po wer supply , ...

  • Xantrex XHR, XFR, XFR3 - page 14

    Features and Specifications Features and Functions 12 Operating Manual for GPIB for XHR/XFR Series Power Supply Features and Functions Features • 16-bit programming and read back of voltage an d current • Programmable soft limits for voltage and current • Programmable over volta ge protection with reset • Easy-to-use, self-docum enting comm ...

  • Xantrex XHR, XFR, XFR3 - page 15

    Features and Specifications Specifications Release 3.1 13 Specifications The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice. Ta b l e 1 . 1 S pecifications for XFR 1200 W Series Supply wi th GPIB Interface Inst alled (7.5 V to 40 V) Models 7.5-140 12-1 ...

  • Xantrex XHR, XFR, XFR3 - page 16

    Features and Specifications Specifications 14 Operating Manual for GPIB for XHR/XFR Series Power Supply Ta b l e 1 . 2 S pec ifications for XFR 1 200 W Series Supply wi th GPIB Interface Inst alled (60 V to 600 V) Models 60-20 100-12 150-8 300-4 600-2 Program Resolution V oltage Current OVP 9.2mV 2.8mA 9.2mV 15.4mV 1.68mA 15.4mV 23.1mV 1.12mA 23.1m ...

  • Xantrex XHR, XFR, XFR3 - page 17

    Features and Specifications Specifications Release 3.1 15 Ta b l e 1 . 3 S pecifications for XFR 2800 W Series Supply with GPIB Interface In stalled (7.5 V to 40 V) Models 7.5-300 12-220 20-130 33-85 40-70 Program Resolution V oltage Current OVP 1.16mV 42.0m A 1.16mV 1.8mV 30.8mA 1.8mV 3.08mV 18.2mA 3.08mV 5.1mV 13.0mA 5.1mV 6.2mV 9.8mA 6.2mV Progr ...

  • Xantrex XHR, XFR, XFR3 - page 18

    Features and Specifications Specifications 16 Operating Manual for GPIB for XHR/XFR Series Power Supply Ta b l e 1 . 4 S pec ifications for XFR 2 800 W Series Supply wi th GPIB Interface Inst alled (60 V to 600 V) Models 60-46 100-28 150-18 300-9 600-4 Program Resolution V oltage Current OVP 9.2mV 6.44mA 9.2mV 15.4mV 3.92mA 15.4mV 23.1mV 2.52mA 23. ...

  • Xantrex XHR, XFR, XFR3 - page 19

    Features and Specifications Specifications Release 3.1 17 T a ble 1.5 S pecifications for XHR 1000 W Series Supply with GPIB Interface Installed (7.5 V to 60 V) Models 7.5-130 20-50 33-33 40-25 60-18 Program Resolution V oltage Current OVP 1.16mV 42.0m A 1.16mV 1.8mV 30.8mA 1.8mV 3.08mV 18.2mA 3.08mV 6.2mV 9.8mA 6.2mV 9.2mV 6.44mA 9.2mV Program Acc ...

  • Xantrex XHR, XFR, XFR3 - page 20

    Features and Specifications Specifications 18 Operating Manual for GPIB for XHR/XFR Series Power Supply T a ble 1.6 S pec ifications for XHR 1000 W Series Supply with GPIB Interface Installed (100 V to 600 V) Models 100-10 150-7 300-3.5 600-1.7 Program Resolution V oltage Current OVP 15.4mV 3.92mA 15.4mV 23.1mV 2.52mA 23.1mV 46.2mV 1.26mA 46.2mV 92 ...

  • Xantrex XHR, XFR, XFR3 - page 21

    Release 3.1 19 Section 2. Inst allation and Configuration Introduction T o use this product, you must have the following equ ipment: • a compatible model of DC output power su pply • IEEE-488 connector and cable • computer with an IEEE-488 interface • Computer-based communications software package W e usually install the GPIB interfa ce in ...

  • Xantrex XHR, XFR, XFR3 - page 22

    Inst allation and Configuration Initial Inspection 20 Operating Manual for GPIB for XHR/XFR Series Power Supply Figure 2.1 Power Supply Fron t Panel with GPIB Interfa ce Installed ( 1200 W att Power Supp ly Shown) ! CAUTION Use proper static control techniques to av oid dama ge to static-sensitive compo nents on the printed circuit board. Address L ...

  • Xantrex XHR, XFR, XFR3 - page 23

    Inst allation and Configuration Initial Inspectio n Release 3.1 21 Figure 2.2 GPIB Interf ace Subplate (Located on Power Supply Rear Pane l) ! CAUTION Use proper static control techniques to av oid dama ge to static-sensitive compo nents on the printed circuit board Error LED (ERR) Indicates tha t a programming error has occurred. Clear with the er ...

  • Xantrex XHR, XFR, XFR3 - page 24

    Inst allation and Configuration Initial Inspection 22 Operating Manual for GPIB for XHR/XFR Series Power Supply Figure 2.3 GPIB Interface PCB JUMPER SELECTION J65 Local OVP control selection [closed] [default]. See page 28. [open] Front Panel OVP Control. J93 User TTL shutdown (S/D) selection [1-2] User TTL S/D line active low . See page 31. [2-3] ...

  • Xantrex XHR, XFR, XFR3 - page 25

    Inst allation and Configuration Basic Setup Procedure Release 3.1 23 Basic Setup Procedure This procedure can be used as a quick reference for those familiar with the configuration requirements for the GPIB interface as installed in the DC power supply . For those who want mo re information, each step refers to more detailed procedures located in s ...

  • Xantrex XHR, XFR, XFR3 - page 26

    Inst allation and Configuration IEEE-488 Primary Address Selection 24 Operating Manual for GPIB for XHR/XFR Series Power Supply IEEE-488 Primary Address Selection 1. Assign a primary address to each power su pply: Choose a number between 0 and 30 which is unique to your IEEE-48 8 bus, that is, different from other device addresses on the same bus. ...

  • Xantrex XHR, XFR, XFR3 - page 27

    Inst allation and Configuration Power On Service Request (PON SRQ) Release 3.1 25 Power On Service Request (PON SRQ) The Power ON Service Request (SRQ) switch is located on the GP IB subplate rear panel S1 switch. Enabling the SRQ switch caus es the power supply to send a service request to the computer cont roller wh en the power supply is turned ...

  • Xantrex XHR, XFR, XFR3 - page 28

    Inst allation and Configuration Remote/Local Operation 26 Operating Manual for GPIB for XHR/XFR Series Power Supply If the rear panel PON REM switch is set to 1, the power supply will power up in local mode. Power supply co ntrol is at the front panel. During an operating session, you can toggle between local mode and remote mode by using the front ...

  • Xantrex XHR, XFR, XFR3 - page 29

    Inst allation and Configuration Remote/Local Operation Release 3.1 27 While in remote mode, you can change to local mode operation by pressing the front panel LOCAL b utton, by sending t he GPIB G TL (Go to L ocal) command, or by negating the GPIB REN (Remot e Enab le) line. Y ou can disable the LOCAL button by enabling the GPIB Local Lockout (LLO) ...

  • Xantrex XHR, XFR, XFR3 - page 30

    Inst allation and Configuration IEEE-488 Controller Connection 28 Operating Manual for GPIB for XHR/XFR Series Power Supply Note : T o disa ble Local Lockout, use the IB IC ibsre0 command in this example. IEEE-488 Controller Connection Use an approved IEEE-488 connector and cable when connecting the power supply’ s GPIB interface to your IEEE-488 ...

  • Xantrex XHR, XFR, XFR3 - page 31

    Inst allation and Configuration Internal PCB Jumper Selections Release 3.1 29 Control Mode Selection” shows a table of jumper settings and OVP programming selection. Refer to “Basic Setup Procedure” on page 23 for the positions of the jumpers on the GPIB PCB. T a ble 2.6 OVP Control Mode Selection TTL Shut down Y ou can us e the Shutdown func ...

  • Xantrex XHR, XFR, XFR3 - page 32

    Inst allation and Configuration User Signals 30 Operating Manual for GPIB for XHR/XFR Series Power Supply User Signals Connector J7 User Signals Auxiliary connector J7, loca ted on the GPIB interface r ear panel, pr ovides several signals to increase your operating cont rol of the supply . These signals are dependen t on the ope rator's design ...

  • Xantrex XHR, XFR, XFR3 - page 33

    Inst allation and Configuration User Signals Release 3.1 31 Figure 2.5 J7 User Signal Conn ector Circuit Block Diagram J7 Cable Connection Use a standard 8-position telephone jack and data cable to connect to J7. Add a ferrite block to reduce radiated emission . The one inch square ferrite block with built-in housing clip is pack aged and shipped w ...

  • Xantrex XHR, XFR, XFR3 - page 34

    Inst allation and Configuration User Signals 32 Operating Manual for GPIB for XHR/XFR Series Power Supply Figure 2.6 J7 User Cab le with Fer rite Block J7 User Cable Ferrite Block T o User Custom Interface T o J7 Connector ...

  • Xantrex XHR, XFR, XFR3 - page 35

    Release 3.1 33 Section 3. Operation Introduction This section covers GPIB interface progra mming, st arting with IEEE-488 functions, continuing with an extensive set of de vice-dep endent commands, and, finally , providing error codes, and status and fault register information. GPIB Operation A GPIB interface controller card enables yo u to control ...

  • Xantrex XHR, XFR, XFR3 - page 36

    Operation GPIB Operation 34 Operating Manual for GPIB for XHR/XFR Series Power Supply Ta b l e 3 . 1 IEEE-488.1 Interface F unctions Implemented Multiline Control Functions The GPIB interface a nd the computer cont roller implement the Acceptor Handshake, Source Handshake, Listener , and T alker fu nctions. No user actio n is required. The unit&apo ...

  • Xantrex XHR, XFR, XFR3 - page 37

    Operation GPIB Operation Release 3.1 35 Device T rigger Device T rigger will implement t he most recently programmed values whether the unit is in local or remote co ntrol. If the power supply is in local mode, the new values will be implemented when it is switched from local to remote control. Device T rigger is typically used to synchronize the o ...

  • Xantrex XHR, XFR, XFR3 - page 38

    Operation GPIB Operation 36 Operating Manual for GPIB for XHR/XFR Series Power Supply Service Request Service request is a uniline message asserted by the power supply at power on and for fault conditions. T en (10) power supply conditions are defined as faults: CV , CC, OV , OTP , SD, FOLD, ERR, ACF , OPF , and SNSP . See “Accumulated S tatus, S ...

  • Xantrex XHR, XFR, XFR3 - page 39

    Operation Command Syntax Release 3.1 37 Command Synt ax Manual Conventions The manual uses these conven tions when displayi ng command information. These characters are not part of the command but are used to denote parameters used with the comma nd. Command Format and Parameters The device-dependent language for the GPIB Interface consists of comm ...

  • Xantrex XHR, XFR, XFR3 - page 40

    Operation Command Syntax 38 Operating Manual for GPIB for XHR/XFR Series Power Supply • Use commas between parameters in th ose commands with more than one parameter , and between mnemonic para meters as in the MASK and UNMASK commands. Only one comma is allowed and it may be preceded or followed by any number of spaces. Example: MASK CV , OV , F ...

  • Xantrex XHR, XFR, XFR3 - page 41

    Operation Command Syntax Release 3.1 39 Command Strings If you send more than one command line, separate the commands with a semicolon. The semicolon may be preceded or followed by spaces. Example: Command T erminators T erminators indicate the end of a command string and tell the power supply to execute the command. The termina tion character is L ...

  • Xantrex XHR, XFR, XFR3 - page 42

    Operation Command Summary 40 Operating Manual for GPIB for XHR/XFR Series Power Supply Command Summary Use these commands to control the opera tion of the supply . They are listed here in order of function such as PROGRAMMING , QUER Y , CALIBRA TION, and ST A TUS commands. See “Command Refe rence” on page 43 for more detailed information about ...

  • Xantrex XHR, XFR, XFR3 - page 43

    Operation Command Summary Release 3.1 41 T a ble 3.6 Query Commands Command Description AUXA? Asks for the state of the set value for the AUXA command AUXB? Asks for the state of the set value for the AUXB command CMODE? Asks for the power supply’s calibration mode st atus. DL Y? Asks for the programmable time delay setting before the supply repo ...

  • Xantrex XHR, XFR, XFR3 - page 44

    Operation Command Summary 42 Operating Manual for GPIB for XHR/XFR Series Power Supply T a ble 3.7 Calibration Commands T a ble 3.8 S tatus Commands Command Description CMODE Places the supply into calibration mode. IDA T A Calculates the slope and intercept for current programming. IHI Sets the current output to the hig h calibration point. ILO Se ...

  • Xantrex XHR, XFR, XFR3 - page 45

    Operation Command Reference Release 3.1 43 Command Reference T a ble 3.9 Command Refe rence Command Description ASTS? Asks for the supply’s accumulate d status register . The accumulated status register stores any bit that was entered in the status register since the accumulated status query command (ASTS?) was last used, regard less of whether t ...

  • Xantrex XHR, XFR, XFR3 - page 46

    Operation Command Reference 44 Operating Manual for GPIB for XHR/XFR Series Power Supply Command Description DL Y <seconds> Sets a programmable time delay employed by the supply before reporting fault conditions. The power supply uses the time delay after receiving a new output voltage or current setting via VSET or ISET , or after receiving ...

  • Xantrex XHR, XFR, XFR3 - page 47

    Operation Command Reference Release 3.1 45 Command Description FOLD? Asks for the supply’s present foldback setting. Response: FOLD <mode> where mode is: 0 (OFF) or 1 (CV or Const ant V oltage mode) or 2 (CC or Const ant Current mode) HOLD <1/ON>,<0/OFF> Enables or disables voltage/current setting hold mode for the supply . When ...

  • Xantrex XHR, XFR, XFR3 - page 48

    Operation Command Reference 46 Operating Manual for GPIB for XHR/XFR Series Power Supply Command Description IRDA T <Ilo>,<Ihi> Calculates and records the slope and of fset for readback volt age using IRLO and IRHI data. Set CMODE ON before using this command. See also the calibration procedures in Section 4. <Ilo> and <Ihi> ...

  • Xantrex XHR, XFR, XFR3 - page 49

    Operation Command Reference Release 3.1 47 Command Description OVCAL Causes the master controller to perform automatic calibration of the supply’s over volt age protection circuitry . Set CMODE O N before using this command. Ensure jumper J65 on the GPIB Interface PCB is connected for remote operation. OVSET <voltage> Sets the supply’ s o ...

  • Xantrex XHR, XFR, XFR3 - page 50

    Operation Command Reference 48 Operating Manual for GPIB for XHR/XFR Series Power Supply Command Description TRG Implements programmed volt age and current settings which had been in hold mode. The supply operates with previous values until the TRG (trigger) command is sent. UNMASK <mnemonics> Enables you to select the s upply operating condi ...

  • Xantrex XHR, XFR, XFR3 - page 51

    Operation Command Reference Release 3.1 49 Command Description VMAX <voltage> Sets an upper sof t limit on the supply’s programmed output volt age. If the soft limit is exceeded, or if the sof t limit value is lower than the present output voltage setting, the supply will ignore the command, turn on the ERR LED, and set the ERR bit in the a ...

  • Xantrex XHR, XFR, XFR3 - page 52

    Operation Accumulated Status, S tatus, and Fault Registers 50 Operating Manual for GPIB for XHR/XFR Series Power Supply Accumulated S t atus, S t atus, and Fault Registers The GPIB option card uses three separate registe rs which are always active. They are the accumulated status, status, and fault registers. Y ou can use the status commands shown ...

  • Xantrex XHR, XFR, XFR3 - page 53

    Operation Error Codes Release 3.1 51 Error Codes If the ERR flag in the accumulated status or fault registers has been activated, an ERR? query will return an error number which corresponds to an event described in the following table. The ERR? query will a lso clear the ERR bit in the register . T a ble 3.1 1 Error Codes ERROR # E RROR IDENTIFICA ...

  • Xantrex XHR, XFR, XFR3 - page 54

    Operation T roubleshooting 52 Operating Manual for GPIB for XHR/XFR Series Power Supply T roubleshooting Diagnostic LEDs This section describes the diagnostic LEDs found on the GPIB interface. Computer Operating Prope rly (COP) LEDs The GPIB interface provides three diagnostic LEDs, locate d at CR167, CR166, and CR89 on its PCB. Refer to Figure 2.3 ...

  • Xantrex XHR, XFR, XFR3 - page 55

    Release 3.1 53 Section 4. Calibration Introduction Y ou can calibrate the GPIB interface by adjusting the signal levels on the interface card so that they correspond to the expected signal levels on the power supply's main assembly . Y ou may need to recalibrate the in terface if you replace parts either on the interface board or on the main p ...

  • Xantrex XHR, XFR, XFR3 - page 56

    Calibration V oltage Mod e Calibration 54 Operating Manual for GPIB for XHR/XFR Series Power Supply V olt age Mode Calibration V oltage Calibration Setup 1. Disconnect the load from the power su pply which is to be calibrated. 2. Connect a voltmeter across the po wer supply’ s output terminals. Figure 4.1 V oltage Calibration Setup V oltage Progr ...

  • Xantrex XHR, XFR, XFR3 - page 57

    Calibration V oltage Mode Calibration Release 3.1 55 3. Send command VRLO; IRLO to the power supply . W ait for the supply to settle. Measure and record the output shown on the external voltmet er . Send VRLO again. 4. Send VRHI; IRHI to the supply . W ait for the supply to settle. Measure and record the output voltage shown on the external voltmet ...

  • Xantrex XHR, XFR, XFR3 - page 58

    Calibration Current Mode Calibration 56 Operating Manual for GPIB for XHR/XFR Series Power Supply Current Mode Calibration Current Calibration Setup 1. Disconnect the load from the po wer supply to be calibrated. 2. Connect a shunt across the supply's output terminals. 3. Connect a voltmeter across the shunt. Figure 4.2 Current Calibration Set ...

  • Xantrex XHR, XFR, XFR3 - page 59

    Calibration Current Mode Calibration Release 3.1 57 Current Readback Calibration Procedure 1. Connect the curre nt shunt and voltmeter to the power supply as shown in Figure 4.2. 2. Activate calibration mode by sendi ng command CMODE ON or CMODE 1 to the power supply . 3. Send command IRLO; V RLO to the power supply . W ait for the supply to settle ...

  • Xantrex XHR, XFR, XFR3 - page 60

    Calibration Over V oltage Protection (OVP) Calibration 58 Operating Manual for GPIB for XHR/XFR Series Power Supply Over V oltage Protection (OVP) Calibration W e recommend that you perform OVP ca libration every six mon ths. Connecting a digital voltmeter as in “V oltage Calibration Setu p” is optional. 1. Disconnect all loads from the power s ...

  • Xantrex XHR, XFR, XFR3 - page 61

    ...

  • Xantrex XHR, XFR, XFR3 - page 62

    Xantrex Technology Inc. 8999 Nelson W ay Burnaby , British Columbia Canada V5A 4B 5 604 422 85 95 T el 604 421 30 56 F a x 800 667 8422 T oll Free North America prg.info@xantrex.com www .xantre x.com TM-GPRF-01XN PRINTED IN CANADA ...

Manufacturer Xantrex Category Portable Generator

Documents that we receive from a manufacturer of a Xantrex XHR, XFR, XFR3 can be divided into several groups. They are, among others:
- Xantrex technical drawings
- XHR, XFR, XFR3 manuals
- Xantrex product data sheets
- information booklets
- or energy labels Xantrex XHR, XFR, XFR3
All of them are important, but the most important information from the point of view of use of the device are in the user manual Xantrex XHR, XFR, XFR3.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Xantrex XHR, XFR, XFR3, service manual, brief instructions and user manuals Xantrex XHR, XFR, XFR3. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Xantrex XHR, XFR, XFR3.

A complete manual for the device Xantrex XHR, XFR, XFR3, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Xantrex XHR, XFR, XFR3 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Xantrex XHR, XFR, XFR3.

A complete Xantrex manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Xantrex XHR, XFR, XFR3 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Xantrex XHR, XFR, XFR3, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Xantrex XHR, XFR, XFR3, that we can find in the current document
3. Tips how to use the basic functions of the device Xantrex XHR, XFR, XFR3 - which should help us in our first steps of using Xantrex XHR, XFR, XFR3
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Xantrex XHR, XFR, XFR3
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Xantrex XHR, XFR, XFR3 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Xantrex XHR, XFR, XFR3?

Use the form below

If you did not solve your problem by using a manual Xantrex XHR, XFR, XFR3, ask a question using the form below. If a user had a similar problem with Xantrex XHR, XFR, XFR3 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)