    ST ANDBY GENERA T OR O WNER'S MANU AL This manual should remain with the unit. A ne w standar d of reliability Serial Number QT 2.4L 45kW Model: 005261-0 —  CAUTION  — ONL Y QU ALIFIED ELECTRICIANS OR CONTRA CT ORS SHOULD A TTEMPT INST ALLA TION! Cover043 Re v . 0 02/06 Part No. 0G0201 ...

  • Grandstream Networks 005261-0 - page 2

    Standby Generator Sets T able of Contents SECTION P AGE SAFETY RULES ................................................ 1-1 INTRODUCTION ..................................................... 1-3 Read this Manual Thoroughly ................................... 1-3 Operation and Maintenance ...................................... 1-3 How to Obtain Servic ...

  • Grandstream Networks 005261-0 - page 3

    1-1 I NTRODUCTION Thank you for purchasing this model of the Stationary Emergency Generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written. However , the manufacturer reserves the right to change, alter or otherwise impro ...

  • Grandstream Networks 005261-0 - page 4

    Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reli- ably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental ru ...

  • Grandstream Networks 005261-0 - page 5

    • Before performing any maintenance on the gen- erator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and ...

  • Grandstream Networks 005261-0 - page 6

    I DENTI F ICA TION R EC ORD D A T A LA BE L  Every generator set has a DA T A LABEL that contains important information pertinent to the generator . The data label, which can be found attached to the gen- erator’s lower connection box, lists the unit ’s serial number and its rated voltage, amps, wattage capac- ity , phase, frequency , rpm, p ...

  • Grandstream Networks 005261-0 - page 7

    E QUIPM ENT DE SCRI PTION This equipment is a revolving field, alternating cur - rent Stationary Emergency Generator . It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units. See the Specifications section for exact num- bers ...

  • Grandstream Networks 005261-0 - page 8

    ENGI N E P RO TE CTIVE DEVICE S The Stationary Emergency Generator may be required to operate for long periods of time without an opera- tor on hand to monitor such engine conditions as coolant temperature, oil pressure or rpm. F or that reason, the engine has several devices designed to protect it against potentially damaging conditions by automat ...

  • Grandstream Networks 005261-0 - page 9

    F U EL SY STEM FUE L RE QUIRE MEN T S  The Stationary Emergency Generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system The Manual Drawing Listing that is affixed to the unit includes the “Identification Code,” which may be used to identify the type of fuel system insta ...

  • Grandstream Networks 005261-0 - page 10

    SP ECIF ICA TIONS GEN ERA T OR T ype ............................................................................. Synchronous Rotor Insulation ................................................................... Class H Stator Insulation .................................................................. Class H T otal Har monic Distor tion ........ ...

  • Grandstream Networks 005261-0 - page 11

    COLD WEA THER KIT F or cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes: • Battery W armer • 4” Junction Box with hardware • 6 qt. pack 5W -30 synthetic oil (engine) R EC ON F IGU R I NG TH E F U EL SY STEM NOTE: All models are configured for natural gas or LP vapor from the factory . T o reconf ...

  • Grandstream Networks 005261-0 - page 12

    AL TER NA T OR A C LEAD C ONN ECTIONS See “V oltage Codes”. This Stationary Emergency Generator may be rated at any one of three voltages, either single -phase or three -phase. The electrical wires in the unit ’s A C connection (lower) panel should be installed according to the number of leads and the voltage/phase required for the applicatio ...

  • Grandstream Networks 005261-0 - page 13

    I NST ALL A TION Refer to the separate “Installation Guide QT Product Line” supplied with the unit. P R EP ARA TION B EFOR E S T ART -U P The instructions in this section assume that the Stationary Emergency Generator has been properly installed, serviced, tested, adjusted and otherwise prepared for use by a competent, qualified installa- tion ...

  • Grandstream Networks 005261-0 - page 14

    • Battery charger connection to 120 V AC. • Communication wires connected between transfer switch and generator (HTS only). • Unit secured to pad. S T ART -U P CH ECKLIS T  Before working on the Stationary Emergency Generator , ensur e the following: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 120V AC supply to the batt ...

  • Grandstream Networks 005261-0 - page 15

    S T A TIONAR Y EM ERGENCY GEN ER A T OR C ONTROL AN D OP ER A TION Refer to the appropriate control panel operator’s manual for this unit. OP ER A TI NG U N IT WITH MAN U AL TR ANSF ER SWIT CH If the Stationary Emergency Generator was installed in conjunction with a transfer switch capable of man- ual operation only , the following procedure appl ...

  • Grandstream Networks 005261-0 - page 16

    MAI NTENANCE P ER FOR M ED B Y AUTHOR IZED SERVICE F A CILITI ES  Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 15A fuse has been removed from the con- trol box. • The 120V AC supply to the battery charger is switched OFF . EVER Y TH R EE MONTHS 1. Check battery condit ...

  • Grandstream Networks 005261-0 - page 17

    Figure 10.1 - Oil Dipstick and Oil Fill Cap Oil Fill Cap Oil Dipstick B A TTE R Y FL UID Check battery electrolyte fluid based on the Maintenance Schedule. Fluid should cover separa- tors in all battery cells. If fluid level is low , add dis - tilled water to cover tops of separators. DO NOT USE T AP W A TER IN BA TTERY . ENGI NE COOL ANT Check coo ...

  • Grandstream Networks 005261-0 - page 18

    CHANGI NG ENGIN E OI L Refer to maintenance performed by authorized service facilities for engine oil and filter change frequencies. Drain the oil while the engine is still warm from run- ning . This means warm up the engine, shut it down and drain immediately as follows: 1. Remove OIL DRAIN HOSE from its retaining clip. 2. Loosen and remove OIL DR ...

  • Grandstream Networks 005261-0 - page 19

    M ISCELLAN EOUS MAINTENANCE CLEAN ING TH E GEN ER A T OR Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance. P eriodically clean generator exterior surfaces. A soft brush may be used to loosen caked on dirt. Use a vacuum system or dr ...

  • Grandstream Networks 005261-0 - page 20

    SERVICE SCHEDULE 22 KW - 150 K W GASEOUS ST A TIONARY EMERGENCY GENERA TOR The following is a recommended maintenance schedule for Gaseous Stationar y Emergency Generator sets from 22kW to 150 kW in size. The established inter vals in the schedule are the maximum recommended when the unit is used in an average ser vice application. They will need t ...

  • Grandstream Networks 005261-0 - page 21

    Maintenance Level 1 Level 2 Level 3 Level 4 Level 5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp. to be done Comp. Required Comp. to be done Comp. to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- Bi- (Date- monthly/ Initials) Break-in Initials) annually/ Initials) Annually/ Ini ...

  • Grandstream Networks 005261-0 - page 22

    Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp. to be done Comp. Required Comp. to be done Comp. to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- Bi- (Date- monthly/ Initials) Break-in Initials) annually/ Initials) Annually/ Init ...

  • Grandstream Networks 005261-0 - page 23

    Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp. to be done Comp. Required Comp. to be done Comp. to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- Bi- (Date- monthly/ Initials) Break-in Initials) annually/ Initials) Annually/ Init ...

  • Grandstream Networks 005261-0 - page 24

    TROU B LESHOO TING GU I DE P ROB LEM CAUSE C OR R ECTION Engine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse. 2. Loose or corroded or defectiv e 2. Tighten, clean or replace batter y cables. batter y cables as necessary . 3. Defectiv e star ter contactor . 3. Replace contactor.* 4. Defectiv e star ter motor . 4. Replace star ter motor .* 5. ...

  • Grandstream Networks 005261-0 - page 25

    Stationary Emergency Generator Notes ...

  • Grandstream Networks 005261-0 - page 26

    ...

  • Grandstream Networks 005261-0 - page 27

    1 0F3 13 7 1 P AN C B C ONN B OX 2 0F 3 1 8 8 1 S TAND R H C ONTR OL 3 0F 3 1 8 9 1 S TAND LH C ONTR OL 4 0 2 3 4 8 4 N 1 BU S H IN G S N A P S B-2 .5 -3 1 5 0 F6 3 6 6 B 1 X FM R D UA L 1 2 0 V /1 6 V (F OR 1 2 0 / 2 4 0 V & 2 7 7 /4 80 V U N ITS) 0 F6 36 6 A 1 XFM R D UA L 1 0 4 V /1 6V (F OR 1 2 0 / 2 0 8 V UN I TS ) 6 04 3 1 8 0 2 WASHE R F ...

  • Grandstream Networks 005261-0 - page 28

    ...

  • Grandstream Networks 005261-0 - page 29

    5) UL CIRCU IT BRE AKER (Q J - 2P) A 0F8137 1 COVER QJ 2P FRM CB C 0E 7994 - CB 0225A 240V 2P S QJ2 2 D 0F8136 1 COVER QJ 2P CB DISH E 036261 4 RIVET POP .125 X .275 SS F 022473 2 WASHE R FLAT 1/ 4-M6 ZI NC G 022097 2 W ASHER LO CK M6- 1/4 H 022127 2 NUT HEX 1/ 4-20 STEEL J 0F8139 1 INSUL CB 2P Q J K 0C2454 9 SCREW THF M6-1 X 16 N WA Z/JS L 022237 ...

  • Grandstream Networks 005261-0 - page 30

    ...

  • Grandstream Networks 005261-0 - page 31

    1 0F9677 1 ROTOR-2 390-45KD1 CPL 0G0056 1 R OTOR-2390- 35KD1 CPL 0G0959 1 R OTOR-2390- 45KD1 CPL (G 2) 0G1155 1 R OTOR-2390- 35KD1 CPL (G 2) 0G1931 1 R OTOR 25KW 3PH DIREC T 390 1800 0G2101 1 R OTOR 25KW 1PH DIREC T 390 1800 0G3734 1 R TR-2390-60K D2 CPL 0G6562 1 R TR 390 35A D1 CPL 0G6564 1 R TR 390 35K D1 CPL 2 0F9664 1 STATOR-3 90 45K 2P 1P H DI ...

  • Grandstream Networks 005261-0 - page 32

    ...

  • Grandstream Networks 005261-0 - page 33

    COMP O N ENTS IN CLUDE D IN 0F9696 E 1 0F1823 A 1 ENCL HSB CONT ROL PANEL 2 0F3078 1 COV ER CONTR OL PANEL 3 0F2606 1 HIN GE CONT INUOUS H-PANEL 4 036261 6 RIVET POP .12 5 X .275 SS 5 043181 4 SCREW PHM M3-0.5 X 10MM 6 05277 7 7 WASHER FLAT M 3 7 0 F 871 0B 1 ASSY PCB C P L2 CTRLR 3600 RPM 8 0F126 2 4 HO LD ER, FU SE WICK MAN N 178. 615 0 9 0F12 63 ...

  • Grandstream Networks 005261-0 - page 34

    ...

  • Grandstream Networks 005261-0 - page 35

    1 0F9517 1 WELDMENT FRAME 2.4L C2 2 052860 4 NUT FL ANGED HEX M1 2-1.75 3 052251 5 DAMPENE R VIBRATION 40 BLUE 4 052257 5 SPACER .49 X .62 X 1 .87 PWDR/ZNC 5 052252 5 DAMPENE R VIBRATION 6 052259 5 WASHE R FLAT M12 7 052891 5 SCREW HHC M12-1.75 X 8 0 G8.8 8 0536210410 1 ASSY WIRE 14.00" 9 042909 1 SCREW HHC M8-1.25 X 30 G8.8 10 04741 1 1 SCREW ...

  • Grandstream Networks 005261-0 - page 36

    ...

  • Grandstream Networks 005261-0 - page 37

    1 0F3408 B 1 BATTERY T RAY C1 CPL 2 0F 3 4 11 1 STRAP BA T TE RY RET AI NM E NT 3 0255 07 REF WAS HER S HAKE P ROOF EX T 7/1 6 S TL 4 0522 12 REF SCRE W HH C M 10-1. 25 X 25 G 8.8 5 0465 26 REF WASHE R L OCK M1 0 6 0221 31 REF WAS HER FLAT 3/ 8-M 10 Z INC 7 05 033 1A REF BATTE RY P OST COVE R RED + 8 0503 31 REF BATT ERY P OST COV ER BLA CK - 9 038 ...

  • Grandstream Networks 005261-0 - page 38

    ...

  • Grandstream Networks 005261-0 - page 39

    1 0G01 58 1 EN GINE 2.4L G 1 2 02213 1 3 WAS HE R FLA T 3/ 8-M1 0 Z INC 3 0F 95 85 1 E XHAU ST A DAP TE R 2. 4L M AC H 4 04652 5 3 NUT HEX M 10-1. 25 G 8 Y EL CH R 5 05221 2 1 ( REF) SCREW HH C M 10- 1.25 X 2 5 G8. 8 6 0E9868A 1 (REF) ALTERNATOR D C W/OUT PUL LEY 7 0F3 2 16B 1 (RE F) PU LLEY 11 7 OD DC ALTE RN ATO R 8 0G0 115 1 (REF) BRACKET TE NSI ...

  • Grandstream Networks 005261-0 - page 40

    ...

  • Grandstream Networks 005261-0 - page 41

    1 0 F9529 1 WELDMENT RAD IA T OR SUPPORT 2. 4L 2 0 F2608 1 RADIATOR 59 8 X 568 X 49 C PL RH 3 0F5263 1 V -BE LT 31/6 4" X 57-3/8" 40 4 6 5 2 6 5 W A S H E R L O C K M 1 0 5 0599 81 4 SCRE W HHC M10- 1. 5 X 30 G10 .9 6 0222 2 2 2 SC RE W HH C 5/ 16- 2 4 X 1- 1/ 2 G5 7 0F5050 1 S HIELD RAD IATOR C5 8 042568 8 S CREW HH C M6-1. 0 X 2 0 G8. 8 ...

  • Grandstream Networks 005261-0 - page 42

    ...

  • Grandstream Networks 005261-0 - page 43

    1 0E 6586 1 GASKET BOSCH 32 & 40 2 0E0519A 1 ADAPTER CA RBURETO R W/PVC C ONN 3 0C8127 1 ELEMEN T AIR CLEANE R 4 049815 4 S CREW HHC M5- 0.8 X 16 G8. 8 5 022127 1 NUT HE X 1/4-20 STEE L (1) 6 062974 1 STUD TH 1/4-20 X 4-1 /2 G2 ZNC 7 0G0190 1 P LATE, AI R CLEANER TOP 2.4L 8 037561 1 NUT WI NG 1/4-20 NYLK ( 1) APPLY MEDIU M STRENGT H BLUE TRE AD ...

  • Grandstream Networks 005261-0 - page 44

    ...

  • Grandstream Networks 005261-0 - page 45

    1 0269 1 5 2 NI PP L E CL OS E 3/ 4 X 1. 37 5 2 075580 1 FLANGE FUEL I NLET 3 0F6390B 1 REG ULATOR A SSY 2.4L 4 0392 5 3 2 S CRE W HH C M8- 1. 2 5 X 20 G 8.8 5 0221 45 2 W ASHE R FL AT 5/16- M 8 Z INC 6 02212 9 2 WASH ER L OCK M 8 -5 /1 6 7 0457 71 2 NUT HEX M8- 1.2 5 G8 CLEA R ZIN C 8 0G0180 1 (REF) GASKET- THROTT LE BODY 9 0E8286 1 STREET EL 45 D ...

  • Grandstream Networks 005261-0 - page 46

    ...

  • Grandstream Networks 005261-0 - page 47

    1 0 G0045 (XX) 1 RE AR WRAP C2 CPL 2 0C2454 54 SCREW THF M6-1 X 16 N WA Z/JS 3 0F5849 (XX) 2 DOOR C2 4 087233 2 RIVET POP .1875 X . 450 SS 5 0E3257 4 S CREW TH-FRM M 6 W/CAP S HKPRF W 6 0F5852 (XX) 2 DISCHARGE DUCT LH & RH SIDE C2 7 0F9833 (XX) 2 FRONT COR NERS C 2 8 0F5851 (XX) 1 DISCHARGE CENTER DUCT C2 9 049813 2 NUT HEX M 6 X 1.0 G 8 YEL CH ...

  • Grandstream Networks 005261-0 - page 48

    ...

  • Grandstream Networks 005261-0 - page 49

    1 0F97 94 1 M UFFLER 7" X 9" X 18-1/2" 2" I N/OUT 2 0G01 13 1 E XH AUS T ELB OW 2 1/ 4 O D 2 1/ 2 O D 3 0F99 37 1 BR ACKET M UFFLE R 4 0F28 30 1 M UFFLER B RACKE T STIFFE NER 5 0F29 62 1 M UFFLER STR AP 6 080762 2 BO LT U 3/8 -16 X 2.62 7 0E0170 A 1 EXHAU ST BLANKET 988MM (C2) 8 0C2454 4 SCR EW THF M6 -1 X 16 N WA Z/J S 9 0F9736 ...

  • Grandstream Networks 005261-0 - page 50

    ...

  • Grandstream Networks 005261-0 - page 51

    ...

  • Grandstream Networks 005261-0 - page 52

    ...

  • Grandstream Networks 005261-0 - page 53

    ...

  • Grandstream Networks 005261-0 - page 54

    ...

  • Grandstream Networks 005261-0 - page 55

    ...

  • Grandstream Networks 005261-0 - page 56

    ...

  • Grandstream Networks 005261-0 - page 57

    ...

  • Grandstream Networks 005261-0 - page 58

    ...

  • Grandstream Networks 005261-0 - page 59

    ...

  • Grandstream Networks 005261-0 - page 60

    ...

  • Grandstream Networks 005261-0 - page 61

    ...

  • Grandstream Networks 005261-0 - page 62

    ...

  • Grandstream Networks 005261-0 - page 63

    1.) C2 UNITS A 0F9 832 1 S HIELD CONN BOX C2 0F9832GGS0R 1 SHIELD CO NTROL STA ND C2 B 0C2454 4 SCREW THF M6-1 X 16 N WA Z/JS 2.) C3 UNITS A 0F9 832B 1 SHIELD CO NTROL ST AND C3 0F9832 KGS0R 1 S HIELD CONTROL S TAND C 3 B 0C2454 3 S CREW THF M6-1 X 16 N WA Z/JS 3.) C4 UNITS A 0F9832A 1 S HIELD CO NTROL STA ND C4 B 0C2454 3 S CREW THF M6-1 X 16 N WA ...

  • Grandstream Networks 005261-0 - page 64

    Stationary Emergency Generator W arranty Printed in U.S.A. GENERA C PO WER SYSTEMS ST ANDARD LIMITED W ARRANTY FOR HOME ST ANDBY/LIGHT COMMERCIAL ST A TIONAR Y EMERGENCY PR ODUCT BELO W 50kW For a period of two (2) y ears from the date of sale, Gener ac P ow er Systems, Inc. will, at its option, repair or replace any par t(s) which, upon examina- t ...

Manufacturer Grandstream Networks Category Portable Generator

Documents that we receive from a manufacturer of a Grandstream Networks 005261-0 can be divided into several groups. They are, among others:
- Grandstream Networks technical drawings
- 005261-0 manuals
- Grandstream Networks product data sheets
- information booklets
- or energy labels Grandstream Networks 005261-0
All of them are important, but the most important information from the point of view of use of the device are in the user manual Grandstream Networks 005261-0.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Grandstream Networks 005261-0, service manual, brief instructions and user manuals Grandstream Networks 005261-0. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Grandstream Networks 005261-0.

A complete manual for the device Grandstream Networks 005261-0, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Grandstream Networks 005261-0 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Grandstream Networks 005261-0.

A complete Grandstream Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Grandstream Networks 005261-0 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Grandstream Networks 005261-0, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Grandstream Networks 005261-0, that we can find in the current document
3. Tips how to use the basic functions of the device Grandstream Networks 005261-0 - which should help us in our first steps of using Grandstream Networks 005261-0
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Grandstream Networks 005261-0
5. FAQ - Frequently Asked Questions