    Processes OM-402B April 1997 Eff. w/Serial Number KH383240 Gas Tungsten Arc (TIG) W elding Shielded Metal Arc (Stick) W elding Flux Cored Arc W elding Description Engine Driven Welding Generator  With Optional Equipment: Metro 250D V isit our website at www.MillerWelds.com ...

  • Miller Electric Metro 250D - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld ...

  • Miller Electric Metro 250D - page 3

    Descripti on Feat ure s  NEW! W arranty extended to 3 years (engine warranted by engine manufacturer)  V ersatile weld output for DC Stick and DC TIG welding  Stepless amperage control for precise heat selection  Arc force control ensures a forceful arc for tight fit-ups − prevents electrode sticking  Built-in Hot Start circuit for ...

  • Miller Electric Metro 250D - page 4

    ...

  • Miller Electric Metro 250D - page 5

    1 OM-402 1 . Safety Precauti ons − Read Before Using 1.1 Symbol Usage OM-402B -4/97, safety_rom 4/97 Means Warning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.  Marks a special safety message.  Means “Note”; not safety related. This group of symbols means W arning! ...

  • Miller Electric Metro 250D - page 6

    2 OM-402 W elding on closed containers, such as tanks, drums, o r pipes, can cause them to blow up. Sparks c a n fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area i ...

  • Miller Electric Metro 250D - page 7

    3 OM-402 MOVING P ARTS can cause injury .  Keep away from fans, belts, and rotors.  Keep all doors, panels, covers, and guards closed and securely in place.  Stop engine before installing or connecting unit.  Have only qualified people remove guards or covers for maint- enance and troubleshooting as necessary .  T o prevent accidenta ...

  • Miller Electric Metro 250D - page 8

    4 OM-402 H. F . RADIA TION can cause interference.  High-frequency (H.F .) can interfere with radio navigation, safety services, computers, and communications equipment.  Have only qualified persons familiar with electronic equipment perform this installation.  Th e user is responsible for having a qualified electrician prompt- ly correct ...

  • Miller Electric Metro 250D - page 9

    5 OM-402 1 . C onsi gn es de sécurité − l ire a vant u t ilisation 1.1 Signification des symboles OM-402B - 4/97, safety_rom_fre 4/97 Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives.  Identifie un message de sécurité particulier ...

  • Miller Electric Metro 250D - page 10

    6 OM-402 Le soudage ef fectué sur des conteneurs fermés tels que des réservoirs, tambours ou des conduites peut provoquer leur éclatement. Des étincelles peuvent être projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des incendies et des brûlures. Le contact acciden ...

  • Miller Electric Metro 250D - page 11

    7 OM-402 DES ORGANES MOBILES peuvent provoquer des blessures.  Ne pas approcher les mains des ventilateurs, cour- roies et autres pièces en mouvement.  Maintenir fermés et fixement en place les portes, panneaux, recouvrements et dispositifs de protection.  Arrêter le moteur avant d’installer ou brancher l’appareil.  Demander seul ...

  • Miller Electric Metro 250D - page 12

    8 OM-402 LES CHARGES ÉLECTROSTA TIQUES peuvent endommager les circuits imprimés.  Établir l a connexion avec la barrette de terre avant de manipuler des cartes ou des pièces.  Utiliser des pochettes et des boîtes antistatiques pour stocker , déplacer ou expédier des cartes de circuits imprimes. UNE REMORQUE QUI BASCULE peut entraîner ...

  • Miller Electric Metro 250D - page 13

    9 OM-402 2 . Defini tions 2.1 Symbols and Definitions Stop Engine Fast (Run, W eld/Power) Fast/Slow (Run/Idle) Slow (Idle) Start Engine Glow Plug T emperature Fuel Engine Oil 14 Remote 14 Panel/Local On Check Injectors/ Pump Check V alve Clearance Battery (Engine) V V olts A Amperes Stick (SMAW) Arc Force (DIG) TIG (GTA W ) G Engine-Driven, Single- ...

  • Miller Electric Metro 250D - page 14

    10 OM-402 3/96 2.2 General Precautionary Label 1 1.1 1.2 1.3 3 3.1 3.2 3.3 4 4.1 S-176 105-A + 2 2.1 2.2 + 5 + 7 7.1 7.2 2.3 + 6 6.1 6.2 6.3 + = A. W arning! Watch Out! There are possible hazards as shown by the symbols. B. Become trained and read the instructions before working on the machine or welding. 1 Electric shock from welding electrode or ...

  • Miller Electric Metro 250D - page 15

    11 OM-402 2.3 Battery Charging Label 3/96 1 W arning! W atch Out! There are possible hazards as shown by the symbols. 2 Do not smoke and keep matches and flames away from battery . 3 Sparks can cause battery gases to explode. Battery explosion can blind and injure. W ear a face shield. 4 Battery acid can burn skin. Do not spill acid. 5 Read Owner ? ...

  • Miller Electric Metro 250D - page 16

    12 OM-402 2.5 Hot Muffler Label 3/96 1 W arning! W atch Out! There are possible hazards as shown by the symbols. 2 Hot muf fler and exhaust pipes can cause severe burns. Do not touch hot muf fler or pipes. 1 S-176 230 2 2.6 Diesel Fuel Label 3/96 1 W arning! W atch Out! There are possible hazards as shown by the symbols. 2 Engine fuel plus flames o ...

  • Miller Electric Metro 250D - page 17

    13 OM-402 2.7 Falling Equipment Label S-176 104 3/96 1 W arning! W atch Out! There are possible hazards as shown by the symbols. 2 Falling equipment can cause serious injury and damage. 3 Use lifting eye to lift or move unit only . Use proper equipment when lifting. 4 Do not use lifting eye to lift and support unit and trailer or other heavy device ...

  • Miller Electric Metro 250D - page 18

    14 OM-402 2.9 Do Not Use Ether Label 3/96 1 W arning! W atch Out! There are possible hazards as shown by the symbols. 2 Ether will damage engine. Do not use ether as a starting aid. 3 Read Owner ’ s Manual. 4 Use glow plugs for 10 − 25 seconds to aid starting in cold weather . 1 S-176 109 10 − 25 s 2 3 4 2.10 Manufacturer ’ s Rating Label S ...

  • Miller Electric Metro 250D - page 19

    15 OM-402 3 . Specifi cations 3.1 W eld, Power , and Engine Specifications Rated W elding Output Amperage Range Maximum Open-Circuit V oltage DC Auxiliary Power Rating Engine Fuel Capacity A verage Sound Level 280 A, 31 V DC, 60% Duty Cycle 250 A, 30 V DC, 100% Duty Cycle 20 − 280 61 (A verage) Single-Phase, 10 kV A/kW , 42 A, 120/240 V , 60 Hz D ...

  • Miller Electric Metro 250D - page 20

    16 OM-402 3.4 Fuel Consumption SA-180 263-A 3.5 Duty Cycle and Overheating Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating.  Exceeding duty cycle can damage unit and void warranty . duty1 5/95 / SB-180 262 4 Minutes W elding 6 Minutes Resting 100% Duty Cycle At 250 Amperes 6 Minutes W elding 4 Minute ...

  • Miller Electric Metro 250D - page 21

    17 OM-402 3.6 AC Auxiliary Power Curve SA-180 260 The auxiliary power curve shows the auxiliary power in amperes available at the receptacles. 4 . Installation 4.1 Installing W elding Generator install1 1/97 − Ref. ST-800 652 / Ref. ST -800 477-A / ST -158 936-A / S-0854 1 Generator Base 2 Metal V ehicle Frame 3 Equipment Grounding T erminal 4 Gr ...

  • Miller Electric Metro 250D - page 22

    18 OM-402 4.2 Connecting Battery and Installing Exhaust Pipe ST-801 079-A / Ref. ST -175 918-C 7/16, 1/2 in + −  Connect negative ( − ) cable last. T ools Needed:  Stop engine.  Installation of exhaust pipe is optional. 4.3 Engine Prestart Checks Ref. ST-159 219-D Check all fluids daily . Unit must be cold an d o n a l e v e l s u r fa ...

  • Miller Electric Metro 250D - page 23

    19 OM-402 4.4 Connecting to Weld Output T erminals Ref. ST-158 936-D / Ref. ST -175 918-C 1 Positive (+) W eld Output T erminal 2 Negative ( − ) W eld Output T erminal For Direct Current Electrode Positi- ve (DCEP), connect work cable to Negative ( − ) terminal and electrode cable (Stick) or torch cable (TIG) t o Positive (+) terminal. Fo r Dir ...

  • Miller Electric Metro 250D - page 24

    20 OM-402 4.6 Remote 14 Receptacle RC1 Information Ref. S T -158 9 3 Socket* Socket Information A 24 volt ac with respect to socket G. Protected by circuit breaker CB5. B Contact closure to A completes 24 volt ac contactor control circuit. AJ B K I G Circuit common for 24 volt ac circuit. B K I C L NH D M G F C 0 to +10 volts dc output to remote co ...

  • Miller Electric Metro 250D - page 25

    21 OM-402 5 . Op eratin g th e Weld ing Generator 5.1 Front Panel Controls Ref. ST-175 918-C 9  Heavy loading during first 50 hours will damage engine. Keep load less than 225A (weld) or 7 k V A (power) for first 5 0 hours. 1 Engine Control Switch Use switch to operate glow plug (optional − see table), start engine, select speed, and stop engi ...

  • Miller Electric Metro 250D - page 26

    22 OM-402 5.2 Remote Amperage and Contactor Control  W eld output terminals are energized when Output (Contactor) Control switch is On and engine is running. 1 Remote 14 Receptacle RC1 Connect optional remote control to RC1 (see Section 4.6).  Place Engine Control switch in Run position for HF-start TIG welding. Ref. ST-158 936-D / Ref. ST -1 ...

  • Miller Electric Metro 250D - page 27

    23 OM-402 6 . Oper ating Auxiliary Equipment 6.1 Auxiliary Power Receptacles  Place Engine Control switch in Run position to maintain weld/power speed under light auxiliary power loads.  Press button to reset circuit breaker . If a circuit breaker continues to open, contact a Factory Authorized Service Agent. 1 120 V 15 A AC Duplex Receptacle ...

  • Miller Electric Metro 250D - page 28

    24 OM-402 7 . Mainte nance & Troubleshoot ing 7.1 Routine Maintenance Recycle engine fluids.  Stop engine before maintaining.  Se e also Engine Manual and Maintenance Label. Service engine more often if used in severe conditions. 8 h Wipe up spills. Check fluid levels. See Section 4.3. 50 h Clean and tighten weld connections. Clean air fi ...

  • Miller Electric Metro 250D - page 29

    25 OM-402 6-2. Maintenance Label S-157 812-E 20W 30 50 40 API CD-MIL L 2104D, SF/CD, CC/CD 2.4 qt (2.3 L) MILLER 066 702 Deutz 77-175-24 MILLER 066 1 1 3 1 1.8 gal (44.6 l ) 100 Hrs. + 12 V BCI 58 430 A @ 0 ° F (-18 ° C) Deutz 77-656-19 72 ° F (20 ° C) 0.006 in (0.15 mm) Deutz 77-644-39 DIESEL DIN 51 601 BS 2869: A1, A2 ASTM D 975-81: 1-D, 2-D ...

  • Miller Electric Metro 250D - page 30

    26 OM-402 7.3 Changing Engine Oil and Oil Filter Ref. ST-159 219-D / Ref. ST -159 215-E / Ref. ST -175 918-C / Ref. S-0842 T ools Needed:  Stop engine. See engine manual for oil/filter change procedure. Drain oil while engine is warm. 1 Oil Fill Caps (Use Either Cap) 2 Oil Drain V alve  Close oil drain valve and cap before adding oil and runn ...

  • Miller Electric Metro 250D - page 31

    27 OM-402 7.4 Changing Fuel Filters  Stop engine and let cool. 1 Secondary Fuel Filter Remove filter . Apply thin film of oil to gasket on new filter . Install filter . 2 Primary Fuel Filter 3 Fuel Line Remove filter . Inspect all fuel lines and replace if cracked or worn. Install new filter and clamps. Wipe up any spilled fuel. Start engine, an ...

  • Miller Electric Metro 250D - page 32

    28 OM-402 7.6 Adjusting Engine Speed After tuning engine, check engine speeds with a tachometer (see table for no load speeds). If necessary , adjust speeds as follows: Start engine and run until warm. Idle Speed Adjustment T urn Engine Control switch to Run/ Idle position. 1 Idle Speed Lock Nut 2 Idle Speed Screw Loosen nut. Turn screw until engin ...

  • Miller Electric Metro 250D - page 33

    29 OM-402 7.7 Overload Protection  Stop engine. If checking fuse, disconnect battery negative ( − ) cable.  Press button to reset circuit breaker . If fuse or breaker continues to open, contact Factory Authorized Service Agent. W eld And Auxiliary Power Circuits 1 Fuse F2 F2 protects battery excitation circuit. If F 2 opens, weld and auxil- ...

  • Miller Electric Metro 250D - page 34

    30 OM-402 7.8 Servicing Optional Spark Arrestor ST-801 154-B / Ref. ST -175 918-C  Stop engine and let cool. 1 Spark Arrestor 2 Cleanout Plug Remove plug and remove any dirt covering cleanout hole. 3 Exhaust Pipe Start engine and run at idle speed to blow out cleanout hole. If nothing blows out of hole, briefly cover end of exhaust pipe with fir ...

  • Miller Electric Metro 250D - page 35

    31 OM-402 T rouble Remedy Erratic weld output. Clean and tighten weld output connections inside and outside unit. Use dry , properly-stored electrodes. Remove excessive coils from weld cables. Be sure connection to work piece is clean and tight. Have Factory Authorized Service Agent check brushes, slip rings, main rectifier , integrated rectifier S ...

  • Miller Electric Metro 250D - page 36

    32 OM-402 T rouble Remedy Engine cranks but does not start. Check fuel level (see Section 4.3). Reset circuit breaker CB6 (see Section 7.7). If equipped with glow plug (optional), reset circuit breaker CB9 (see Section 7.7). Check Engine Control switch S1, and replace if necessary . Check low oil pressure shutdown switch S2, and replace if necessar ...

  • Miller Electric Metro 250D - page 37

    33 OM-402 Notes ...

  • Miller Electric Metro 250D - page 38

    34 OM-402 8 . Electrical Diagram 8.1 Circuit Diagram for Welding Generator ...

  • Miller Electric Metro 250D - page 39

    35 OM-402 SC-181 758 ...

  • Miller Electric Metro 250D - page 40

    36 OM-402 9. Run-In Pr ocedur e 9.1 W etstacking runin2 12/96  Heavy loading during first 5 0 hours will damage engine. Keep load less than 225A (weld) or 7 kV A (power) for first 5 0 hours.  Do not idle engine longer than necessary . Piston rings seat faster if engine runs at weld/ power rpm, and the welding generator is kept loaded during r ...

  • Miller Electric Metro 250D - page 41

    37 OM-402 9.2 Run-In Procedure Using Load Bank S-0683  Stop engine.  Do not touch hot exhaust pipe, engine parts, or load bank/grid.  Keep exhaust and pipe away from flammables. 1 Load Bank T urn all load bank switches Of f. If needed, connect load bank to 1 15 volts ac wall receptacle or genera- tor auxiliary power receptacle. 2 Welding G ...

  • Miller Electric Metro 250D - page 42

    38 OM-402 9.3 Run-In Procedure Using Resistance Grid S-0684  Stop engine.  Do not touch hot exhaust pipe, engine parts, or load bank/ grid.  Keep exhaust and pipe away from flammables. 1 Resistance Grid Use grid sized for generator rated output. Turn Off grid. 2 Welding Generator Set Amperage control at min. 3 W eld Cables Connect grid to ...

  • Miller Electric Metro 250D - page 43

    39 OM-402 10 . Auxiliary Power Guidelines 10.1 Selecting Equipment aux_pwr 12/96 − Ref. ST-159 730 / ST -800 577 1 Auxiliary Power Receptacles − Neutral Bonded T o Frame 2 3-Prong Plug From Case Grounded Equipment 3 2-Prong Plug From Double Insulated Equipment OR 2 Be sure equipment has this symbol and/or wording. 3 1 10.2 Grounding Generator t ...

  • Miller Electric Metro 250D - page 44

    40 OM-402 10.3 Grounding When Supplying Building Systems ST-800 576-B 1 Equipment Grounding T erminal 2 Grounding Cable Use #10 AWG or larger insulated copper wire. 3 Ground Device  Ground generator to system earth ground if supplying power to a premises (home, shop, farm) wiring system. GND/PE 1 2 Us e ground device as stated in electrical code ...

  • Miller Electric Metro 250D - page 45

    41 OM-402 10.5 Approximate Power Requirements for Industrial Motors Industrial Motors Rating Sta rtin g W atts Running W atts Split Phase 1/8 HP 800 300 1/6 HP 1225 500 1/4 HP 1600 600 1/3 HP 2100 700 1/2 HP 3175 875 Capacitor Start-Induction Run 1/3 HP 2020 720 1/2 HP 3075 975 3/4 HP 4500 1400 1 HP 6100 1600 1-1/2 HP 8200 2200 2 HP 10550 2850 3 HP ...

  • Miller Electric Metro 250D - page 46

    42 OM-402 10.7 Approximate Power Requirements for Contractor Equipment Contractor Rating Starting W atts Running W atts Hand Drill 1/4 in 350 350 3/8 in 400 400 1/2 in 600 600 Circular Saw 6-1/2 in 500 500 7-1/4 in 900 900 8-1/4 in 1400 1400 T able Saw 9 in 4500 1500 10 in 6300 1800 Band Saw 14 in 2500 1 100 Bench Grinder 6 in 1720 720 8 in 3900 14 ...

  • Miller Electric Metro 250D - page 47

    43 OM-402 10.8 Power Required to Start Motor S-0624 1 Motor Start Code 2 Running Amperage 3 Motor HP 4 Motor V oltage T o find starting amperage: Step 1: Find code and use table to find kV A/HP . If code is not listed, multiply running amperage by six to find starting amperage. Step 2 : Find Motor HP and V olts. Step 3: Determine starting amper- ag ...

  • Miller Electric Metro 250D - page 48

    44 OM-402 10.10 T ypical Connections to Supply Standby Power S-0405-A 1 Power Company Service Meter 2 Main and Branch Overcurrent Protection 3 Double-Pole, Double-Throw T ransfer Switch Obtain and install correct switch. Switch rating must be same as or greater than the branch overcurrent protection. 4 Circuit Breakers or Fused Disconnect Switch Ob ...

  • Miller Electric Metro 250D - page 49

    45 OM-402 10.1 1 Selecting Extension Cord (Use Shortest Cord Possible) Cord Lengths for 120 V olt Loads  If unit does not have GFCI receptacles, use GFCI-protected extension cord. Maximum Allowable Cord Length in ft (m) for Conductor Size (A WG)* Current (Amperes) Load (W atts) 4 6 8 10 12 14 5 600 350 (106) 225 (68) 137 (42) 100 (30) 7 840 400 ...

  • Miller Electric Metro 250D - page 50

    46 OM-402 1 1. P a r t s L i s t 1 1.1 Main Assembly 1 2 3 4 5 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 84 85 86 87 88 89 90 91 92 93 96 94 6 7 Fig 1 1 -2 Fig 1 1 -4 95 83  Hardware is common and not available unless listed. ...

  • Miller Electric Metro 250D - page 51

    47 OM-402 30 ST-801 488-A 31 32 33 34 35 36 37 38 39 40 43 45 47 48 49 50 51 52 53 54 56 Fig 1 1 -3 57 58 59 60 62 63 65 66 67 68 69 70 71 72 73 74 75 76 77 78 80 79 81 61 82 42 64 55 41 44 46 ...

  • Miller Electric Metro 250D - page 52

    48 OM-402 1 1.1 (Continued) Description Part No. Dia. Mkgs. Item No. Quantity 1 +163 828 P ANEL, side LH 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 164 507 P ANEL, side LH rear 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Metro 250D - page 53

    49 OM-402 1 1.1 (Continued) Description Part No. Dia. Mkgs. Item No. Quantity 41 173 931 PIPE, exhaust elbow 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 167 313 LA TCH, elastic draw 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Metro 250D - page 54

    50 OM-402 1 1.1 (Continued) Description Part No. Dia. Mkgs. Item No. Quantity 88 162 515 RECTIFIER, si diode (consisting of) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C1,3 048 420 CAP ACITOR, cer disc .01uf 1000VDC 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Metro 250D - page 55

    51 OM-402 1 1.2 (Continued) ST-801 515-A 1 2 3 4 5 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28  Hardware is common and not available unless listed. Description Part No. Dia. Mkgs. Item No. Quantity 13 CB5 083 432 CIRCUIT BREAKER, man reset 1P 10A 250V AC 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ...

  • Miller Electric Metro 250D - page 56

    52 OM-402 1 1.3 Generator (Fig 1 1.1 Item 56) 1 ST-801 289A 2 4 5 3 6 7 8 9 10 11 16 15 14 13 12  Hardware is common and not available unless listed. Description Part No. Item No. Quantity 1 166 770 STUD, stl .375-16 x 19.750 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 160 943 ...

  • Miller Electric Metro 250D - page 57

    53 OM-402 ST-801 288 1 2 3 4 4 5 6 7 8 9 10 11 12 13 8 14 15 16 1 1.4 Control Box w/Components (Fig 1 1.1 Item 86)  Hardware is common and not available unless listed. Description Part No. Dia. Mkgs. Item No. Quantity 1 D1,5 135 184 DIODE BOARD 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Metro 250D - page 58

    54 OM-402 Notes ...

  • Miller Electric Metro 250D - page 59

    Notes ...

  • Miller Electric Metro 250D - page 60

    56 OM-402 Notes ...

  • Miller Electric Metro 250D - page 61

    Notes ...

  • Miller Electric Metro 250D - page 62

    58 OM-303 12 . Options and Accessories 12.1 Metro 250D WELD METERS − DC AMP & VOL T (#042 947 Field ) Machine is prewired for easy installation of field kit. ST ARTING AID KITS (#043 139 Field ) Improve starting in cold weather by adding air intake manifold glow plug. Machine is prewired. SP ARK ARRESTOR (#042 915) May be mandatory in some ar ...

  • Miller Electric Metro 250D - page 63

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise o ...

  • Miller Electric Metro 250D - page 64

    PRINTED IN USA  2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Compa ny 1635 West S pencer Street Applet on, WI 54914 USA International He adquarte rs − US A USA Phone: 920-735-4505 Auto-At t ended USA & Canada F A X: 9 20-735-4134 Int ernati onal F AX: 9 20-735-4125 European Headqua rters − United ...

Manufacturer Miller Electric Category Welding System

Documents that we receive from a manufacturer of a Miller Electric Metro 250D can be divided into several groups. They are, among others:
- Miller Electric technical drawings
- Metro 250D manuals
- Miller Electric product data sheets
- information booklets
- or energy labels Miller Electric Metro 250D
All of them are important, but the most important information from the point of view of use of the device are in the user manual Miller Electric Metro 250D.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Miller Electric Metro 250D, service manual, brief instructions and user manuals Miller Electric Metro 250D. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Miller Electric Metro 250D.

A complete manual for the device Miller Electric Metro 250D, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Miller Electric Metro 250D by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Miller Electric Metro 250D.

A complete Miller Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Miller Electric Metro 250D - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Miller Electric Metro 250D, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Miller Electric Metro 250D, that we can find in the current document
3. Tips how to use the basic functions of the device Miller Electric Metro 250D - which should help us in our first steps of using Miller Electric Metro 250D
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Miller Electric Metro 250D
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Miller Electric Metro 250D in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Miller Electric Metro 250D?

Use the form below

If you did not solve your problem by using a manual Miller Electric Metro 250D, ask a question using the form below. If a user had a similar problem with Miller Electric Metro 250D it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)