Manual Bloomfield WVG-136RWT

30 pages 0.93 mb
Download

Go to site of 30

Summary
  • Bloomfield WVG-136RWT - page 1

    PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P . O. Box 280 V erdi, NV 89439 www .wellsbloomfield.com telephone: 775-689-5703 fax: 775-689-5976 OPERA TION MANUAL WV G-136 SERIES GRIDDLE with UNIVERSAL HOOD MODELS: WVG-136 WVG-136R W WVG-136R WT Includes INST ALLA TION USE & CARE IMPORTANT: DO NOT DI SCARD THIS MANU ...

  • Bloomfield WVG-136RWT - page 2

    502 p/n 304986 OpM WVG-136 Ventless Grid dle Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in ma terials and workmanship for a period of one year from the date of original installation or 18 months from the date of shipment from our factor y, whichever comes first, an ...

  • Bloomfield WVG-136RWT - page 3

    WARRANTY ................. .................................... ........... xi SPECIFICATIONS ........... .................................... ........ 1 FEATURES & OPERATING CONTROLS ................... 2 PRECAUTIONS & GENERAL INFO RMATION ........... 6 AGENCY LISTING INFORMATION .. ................. ......... 7 INSTALLATION ..... ........ ...

  • Bloomfield WVG-136RWT - page 4

    FEATURES & OPERATING CONTROLS Fig. 1 Ventilator Section Operating Features & Controls 2 28 28 19 16 23 a15 a1 1 53 56 18 9 8 38 VENTIL AT OR CONT ROL P ANEL see pa ges 4 & 5 GRIDDLE CONTROL P ANEL see page s 4 & 5 18 16 23 WARMER CONTROLS see pa ges 4 & 5 PULL HAN D LE TO ACTI VATE FIRE SU PPRESSION SYSTEM IN CA SE O F FIRE ANSU ...

  • Bloomfield WVG-136RWT - page 5

    ITEM 1. a6. 8. 9. a10. a11. 12. a15. 16. 18. 19. 22. 23. 28. a31. 38. 40. 41. 42. 43. 44. 53. 56. DESCRIPTION NAMEPLATE FIRE SUPPRESSION AGENT TANK (1.5 gal.) ADJUSTABLE (FRONT) LEG RIGID (REAR) CASTER MANUAL PULL STATION FUSIBLE LINKS LOWER REAR ACCESS PANEL DISCHARGE NOZZLE GREASE BAFFLE PRE-FILTER ASSEMBLY HEPA/CHARCOAL FILTER PACK GREASE CUP GR ...

  • Bloomfield WVG-136RWT - page 6

    FEATURES & OPERATING CONTROLS (continued) Fig. 2 Ventilator Section Controls & Indicator Lights Fig. 3 Griddle & Warmer Drawe r Operating Features & Controls 4 502 p/n 304986 OpM WVG-136 Ventless Grid dle GRIDDLE GREASE TROUGH GRIDDLE SURF ACE GREASE DRAWER OPTIONAL ROLL WARMER G.02 G.01 W .06 W .06 W .05 W .07 W .04 W .01 W .09 W . ...

  • Bloomfield WVG-136RWT - page 7

    ITEM V.01 V.02 V.03 V.04* V.05* V.06* G.01 G.02 W.01 W.02 W.03 W.04 W.05 W.06 W.07 W.08 W.09 DESCRIPTION POWER SWITCH POWER ON INDICATOR CHECK FILTERS ALARM INDICATOR REPLACE PREFILTER ALARM INDICATOR REPLACE FILTER PACK ALARM INDICATOR SERVICE REQUIRED ALARM INDICATOR GRIDDLE TEMPERATURE CONTROL INDICATOR LIGHT WARMER TEMPERATURE CONTROL POWER ON ...

  • Bloomfield WVG-136RWT - page 8

    NOTE: Fire suppression system and all associated comp onents must only be serviced by an authorized Ansu l® Distri butor. All setup, charging, repair and/or adjustment of th e fire sup pression system must be performed by an Authorized Ansul® Distributor ONLY . IMPORTANT: If a remote pull station is installed, both rea r casters (9) must be repla ...

  • Bloomfield WVG-136RWT - page 9

    AGENCY LISTING INFORMATION OPERATIONAL NOTES: REPLACE PREFILTER and REPLACE FILTER PACK indicator lights provide a timely warning that a system shut-down is i mminent. The actual time between the indicator li ght comin g on and the loss of cooking appliance power will depend upon the cooking conditions. Anytime a dirty PRE-FILTER is replaced, the s ...

  • Bloomfield WVG-136RWT - page 10

    INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual. WARNING: RISK OF INJURY Installation procedures mu st be performed by a qualified technician with full ...

  • Bloomfield WVG-136RWT - page 11

    SERVICE TECHNICIAN IN STALLATION NOTES An Ansul® technician must charge an d arm the fire suppression system before the ventilator blower will operate. See page 10 . Installation and start up must be performed by an Authorized Installation Company. Installer must complete the WARRANTY REGISTRATION form, and record appliance installation particular ...

  • Bloomfield WVG-136RWT - page 12

    INSTALLATION (continued) FIRE SUPPRESSION SYSTEM INSTALLATION 1. Any REMOTE MANUAL PULL STATION must b e installed by an authorized ANSUL® distributor in accordan ce with the AUTHORITY HAVING JURISDICTION. NOTE: If a REMOTE MANUAL PULL STAT ION is installed, moving the unit for servic ing will cause the Ansul® system to discharge. In this case, t ...

  • Bloomfield WVG-136RWT - page 13

    FILTERS INSTALLATION 1. FILTER PACK: Ships installed in the hood. If the FILTER PACK is not in position, the CHECK FILTERS indicator will light. If the FILTER PACK becomes clogged, the REPLACE FILTER PACK indicator will glow. To install the FILTER PACK: Position the filter pack with the charcoal portion UP. Slide the filt er pack toward the rear of ...

  • Bloomfield WVG-136RWT - page 14

    INSTALLATION (continued) WARNING SLIP / FALL HAZARD SPILLED OIL DO NOT OPERATE UNLESS THE GREASE CUP TROUGH AND GREASE DRAWER ARE INSTALLED. Oil and moisture will drip onto the floor and falls may result. Death or serious injury ma y result from slipping and falling GREASE TROUGH AND GREASE CUP INSTALLATION 1. Install the GREASE TROUGH into the bra ...

  • Bloomfield WVG-136RWT - page 15

    OPERATION CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. VENTILATOR OPERATION 1. Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position and not clogged, the griddle will be energized. The ...

  • Bloomfield WVG-136RWT - page 16

    OPERATION (continued) CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. As manufactured, the steel surface of your Wells griddle has microscopic pores. It is important to fill these pores with oil in order to provide a hard, non-stick cooking surface. Because the microscopic pores in the griddle surface are filled b ...

  • Bloomfield WVG-136RWT - page 17

    OPERATION (continued) CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. NOTE: The chart below is intended as a guide ONLY. Your own experience with this appliance, type of foods and method of operation will enable you to determine the temperature control and air vent settings best suited to your operation. DRAWER WA ...

  • Bloomfield WVG-136RWT - page 18

    OPERATION (continued) 16 ºF ºC LOAD PROCESS 3 2 5 1 4 RWT- CONTROL MOD ULE SET SETPOINT TEMPERATURE Press an arrow key: UP arrow to increase DO WN arrow to decrease Release key when desire d setpoint temperature is displayed. Reading is locked into memory 3 seco n ds after last key stro k e. Minimum setpoint is 140ºF (60ºC) Maximum setpoint is ...

  • Bloomfield WVG-136RWT - page 19

    17 CLEANING INSTRUCTIONS CAUTION: ELECTRIC SHOCK HAZARD Disconnect appliance from electric power before cleaning. CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: DO NOT spill or pour water into controls, control panel, wiring or coil-type hotplate elements. Damag ...

  • Bloomfield WVG-136RWT - page 20

    18 502 p/n 304986 OpM WVG-136 Ventless Grid dle CLEANING INSTRUCTIONS (continued) VENTILATOR WEEKLY CLEANING PREPARATION: Disconnect applian ce fro m electric power Allow to cool before cleaning FREQUENCY: Weekly TOOLS: Warm water and a mild detergent Soft clean cloth or sponge Bristle brush Container for disposal of grease 1. Remove the grease baf ...

  • Bloomfield WVG-136RWT - page 21

    CLEANING INSTRUCTIONS (continued) 19 CAUTION: ELECTRIC SHOCK HAZARD Disconnect appliance from electric power before cleaning. CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: Never allow PRE-FILTER or FILTER PACK to get wet. DO NOT wash either of these two filters ...

  • Bloomfield WVG-136RWT - page 22

    DRAWER WARMER DAILY CLEANING PRECAUTIONS: Turn control knob to OFF. Allow drawers to cool before proceeding. R e m o v e d r a w e r pans and Humitrol racks. FREQUENCY: Minimum -Daily TOOLS: Warm water and mild detergent Clean cloth or sponge 1. R emove drawe rs from warmer : a. Pull warmer drawer out until fully extended. b. Slide finger along lef ...

  • Bloomfield WVG-136RWT - page 23

    MAINTENANCE SCHEDULES USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS , N.F.P.A 17A & N.F.P.A. 96 (current editions). DANGER FIRE HAZARD FAILURE TO PROPERLY CLEAN AND MAINTAIN THIS EQUIPMENT CAN CAUSE A FIRE. AN UNCONTRO LLED FIRE CAN CAUSE SERIOUS INJURY, ...

  • Bloomfield WVG-136RWT - page 24

    22 WELLS BLOOMFIELD, LLC 502 p/n 304986 OpM WVG-136 Ventless Grid dle ...

  • Bloomfield WVG-136RWT - page 25

    23 WELLS BLOOMFIELD, LLC Replace two (2) fire suppression links at cooking appliance: each link is rated @ 212ºF Replace fire damper fusible link: rated @ 280ºF Max interval: 12 months 502 p/n 304986 OpM WVG-136 Ventless Grid dle ...

  • Bloomfield WVG-136RWT - page 26

    24 ANSU L ® ANSUL INCORPORA TED MAR I N ET T E, WI 541 43 - 25 42 MA TERIAL SAFETY D A T A SHEET ANSULEX L ow pH QUICK IDENT IFIER (In Plant C ommon Name) Manufa c turer’s Name: Eme rgenc y T elephone No.: ANSUL INCORP ORAT ED CHEMT REC (800) 424-9 300 or ( 70 3) 527-3 887 Prep ared By: Addres s : On e S tant on S treet, Mari ne t te , WI 5 414 ...

  • Bloomfield WVG-136RWT - page 27

    25 SECTION 5 - HEAL T H HAZ ARDS SECTION 6 - EMERGENCY AND FIRST AID PROC EDURES SECTIO N 7 - SPECIAL PROTECTIO N INFOR M A TION SECTIO N 8 - SPECIAL PRECAUT I ONS AND SPI LL/LEAK PR OCEDURES HAZARDOU S MA TERIAL IDENTIFI CA TION SYSTEM ANSU LEX Low p H (cont inued) Threshol d Limit V alue: Non e Est a bl is he d Routes of Entry: Eye Conta ct: Irri ...

  • Bloomfield WVG-136RWT - page 28

    TROUBLESHOOTING SUGGESTIONS SYMPTOM Ventilator blower won’t run Ventilator blower won’t run - buzzer sounding Ventilator blower runs momentarily, shuts down. CHECK FILTERS light on REPLACE PREFILTER light on. REPLACE FILTER PACK light on SERVICE REQUIRED light on Griddle won’t heat One or more griddle sections not hot enough Roll warmers won? ...

  • Bloomfield WVG-136RWT - page 29

    D E S C R I P T I O N S E R V I C E P A R T N O . PRE-FILTER 22618 PRE-FILTER CAGE 22683 FILTER PACK (HEPA + CHARCOAL) 22619 GREASE BAFFLE 22684 LEG KIT 22649 CASTER KIT 22650 GREASE CUP 22626 SCRAPER, GROOVED GRIDDLE 20651 DRAWER PAN, REPLACEMENT 21488 RACK, HUMITROL 20624 WELLS BULLETIN (ANSUL® PARTS LIST) 303331 NOTE: Ansul® Manual 418087 -05 ...

  • Bloomfield WVG-136RWT - page 30

    Genuine Parts Protect - YOU - All - W ays SER VICE TRAINING - QUALITY SER VICE SER VICE TRAINING - QUALITY SER VICE CUSTOMER SA TISF ACTION CUSTOMER SA TISF ACTION Commercial Food Equipment Service Association Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD ...

Manufacturer Bloomfield Category Griddle

Documents that we receive from a manufacturer of a Bloomfield WVG-136RWT can be divided into several groups. They are, among others:
- Bloomfield technical drawings
- WVG-136RWT manuals
- Bloomfield product data sheets
- information booklets
- or energy labels Bloomfield WVG-136RWT
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bloomfield WVG-136RWT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bloomfield WVG-136RWT, service manual, brief instructions and user manuals Bloomfield WVG-136RWT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bloomfield WVG-136RWT.

Similar manuals

A complete manual for the device Bloomfield WVG-136RWT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bloomfield WVG-136RWT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bloomfield WVG-136RWT.

A complete Bloomfield manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bloomfield WVG-136RWT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bloomfield WVG-136RWT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bloomfield WVG-136RWT, that we can find in the current document
3. Tips how to use the basic functions of the device Bloomfield WVG-136RWT - which should help us in our first steps of using Bloomfield WVG-136RWT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bloomfield WVG-136RWT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bloomfield WVG-136RWT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bloomfield WVG-136RWT?

Use the form below

If you did not solve your problem by using a manual Bloomfield WVG-136RWT, ask a question using the form below. If a user had a similar problem with Bloomfield WVG-136RWT it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)