    Dell™ PowerConnect™ 6224/ 6224F/6224P/6248/6248P PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Date: May 2010 System Firmwar e Version 3.2.0.6 Information in th is document is subject to change w ithout notice. © 2003 – 2010 Dell Inc. All rights reserved. Reproduction in any manner whatsoever wit hout the wr itten perm ission of Del ...

  • Dell 6248P - page 2

    i i System Firmware V ersi on 3. 2.0 .6 Table of Contents Introduction 1 Global Support 1 Firmware Specifi cations 1 Hardware Suppor ted 2 Added Functiona lity in this Rele ase 3 Changed Functio nality in this Release 11 Deprecated Commands and Parameters 15 Issues Resol ved 17 CLI Reference Manual Updates 21 User’s Gui de Updates 24 Known Issues ...

  • Dell 6248P - page 3

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 1 Introduction This document provides specific informa tion for the Dell PowerConnect 6200 Ser ies switches, firmware v ersion 3.2.0.6. It is recommended that this release note be thoroughly re viewed prior to installing or upgrading of t his product. Glob ...

  • Dell 6248P - page 4

    2 System Firmware V ersi on 3. 2.0.6 Firmware Image Name Version No. Release Date PC6200v3.2.0.6.stk 3.2.0.6 May 2010 Version Numbering C onvention Version number Description 6200 Series 3 2 0 6 Four part version number  Denotes the build number.  Denotes an ad hoc release of the product software.  Denotes a scheduled maintenance release o ...

  • Dell 6248P - page 5

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 3 Added Functionality in this Release ¾ Non-Stop F orwarding This feature creates an optio n to allo w the forwardi ng plane o f stack units to c ontinue to f orward packets while the control and manage ment planes restart as a re sult of a power failure, ...

  • Dell 6248P - page 6

    4 System Firmware V ersi on 3. 2.0.6 ¾ Serviceability Tracing Commands Debug comm ands provi ded to enable t racing of vari ous protoc ols. ¾ Faster Initialization for Stacking Failo ver Fast Reinitialization invo lves improvement in: • Detection of M anagement U nit Failure • Building Card M a nage r Dat a base • Application of saved confi ...

  • Dell 6248P - page 7

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 5 ¾ MLD Snooping (RFC2710) In IPv4, Lay er 2 switches ca n use IGMP S nooping to li mit the fl ooding of m ulticast traffic by dynamicall y configuring Layer 2 interfaces so that multicast traffic is forwarded to only those in terfaces associated with IP ...

  • Dell 6248P - page 8

    6 System Firmware V ersi on 3. 2.0.6 ¾ RADIUS Enhancem ents • The maxim um number of RADIUS servers supported has i ncreased from three to 32. • RADIUS servers with the sam e name can be use d as Backups (RADIUS Authentication and Accounting server s) • Simultaneous Transactions to Multiple RADIUS Servers • RADIUS Accounting – Allows a c ...

  • Dell 6248P - page 9

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 7 ¾ Ping/Traceroute Enhancem ents New ping opt ions have bee n added to all ow the user t o specify the number and size o f echo requests a nd the interval between echo requests. A ping can now be initiated via SNMP using the MIB defined in RFC 2925. New ...

  • Dell 6248P - page 10

    8 System Firmware V ersi on 3. 2.0.6 ¾ Granular OSPF v2/v3 Tra ps Configure which of the OSPF traps the OSPF Router should generate by enab ling or disabling the trap condition. If a trap condition is enabled and the condition is detected, the OSPF router will send the trap to all trap receivers. ¾ auto-cost reference bandwi dth and bandwidth Com ...

  • Dell 6248P - page 11

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 9 ¾ Configure d Tunnels M TU To comply with RFC 4213, Basic Transition Mech anis ms for IPv6 Hosts and Routers, the IPv6 MTU on configured IPv6 over IPv4 tunnels was changed from 1480 bytes to 128 0 bytes. ¾ IPv6 6 to 4 Auto Tun nel s The 6 to 4 tunnels ...

  • Dell 6248P - page 12

    1 0 System Firmware Version 3. 2.0.6 ¾ IPv6 Mana gement Enha ncements Provides the following: • Dual IPv4/IP v 6 ope ration over the net wo rk po rt • Static assignm ent of IPv6 add resses and gateways f or the service/ network ports • Ability to ping an IPv6 link-local ad dress over the serv ice/n etwork port • SNMP traps and que ries via ...

  • Dell 6248P - page 13

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 11 Changed Functionality in this Release ¾ Spanning Tree U pdate – 802.1Q -2005 Spanning Tree now supports IEEE802 .1Q-2005. Th is version of the IEEE Multiple Sp ann ing Tree Protocol corrects problems associated with the previou s versio n, provides f ...

  • Dell 6248P - page 14

    1 2 System Firmware Version 3. 2.0.6 ¾ ip route Comm and Changed The syntax of the ip route command has changed. The metric keywor d is no longer accepted as it had no effect. The new synta x is: ip route ip addr subnetmask | prefix-length nextHopRtr [ preference ] ¾ distance ospf Comma nd Changed The distance ospf comm and has been change d (for ...

  • Dell 6248P - page 15

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 13 ¾ Trap Configuration In previous versions of the software, configuration of the flags for controllin g traps was scattered about in a number of plac es. snmp-server enable tr aps is now a common c ommand for configur ing al l trap flags. The legacy com ...

  • Dell 6248P - page 16

    1 4 System Firmware Version 3. 2.0.6 ¾ ACL Changes The following changes apply to ingress and egress ACLs: o Maximum of 100 ACLs o Maximum rules per ACL are 127 Note: Altho ug h th e max imu m nu mb e r o f ACL s is 100 , an d t h e max imu m nu mb er o f ru les per AC L is 1 2 7, the system cannot support 100 ACLs t hat each has 127 r ules. Note: ...

  • Dell 6248P - page 17

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 15 Deprecated Commands and Parameters The following CLI commands have been deprecated since the 2.x release. Title Description bridge address Interface Configuration mode Rationale: The following par ameters have been depr ecate d: • delete-on-reset • ...

  • Dell 6248P - page 18

    1 6 System Firmware Version 3. 2.0.6 Title Description ip osp f Interface Configuration mode Rationale: The ip ospf command has been deprecate d. This functionality has been replaced by the ip ospf area command. ip ospf are aid Interface Configuration mode Rationale: The ip ospf areaid command has been de precat ed. This functionality has been re p ...

  • Dell 6248P - page 19

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 17 Issues Resolved The following is a list of issues resolved in the current firm ware release. Description User Impact Resolution Unable to configure IPv6 host (4001::2) as an SNMP trap receiver on the DUT. User is not aware that the only IPv4 address is ...

  • Dell 6248P - page 20

    1 8 System Firmware Version 3. 2.0.6 Description User Impact Resolution Bridge multicast forbidden forward-unregistered caus es L3 Multicast to fail. Flooding in ingress VLAN. Modified the L3 interaction code of snooping to notify the driver when snooping is enabled. When snooping is disabled, the curr ent operational state of snooping i s also sen ...

  • Dell 6248P - page 21

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 19 Description User Impact Resolution Cannot enter Daylight Saving Time from Web interface. In summer time configuration page, in recursive mode, clock zone field is not accepting valid range. In summer time configuration page, in recursive mode, added app ...

  • Dell 6248P - page 22

    2 0 System Firmware Version 3. 2.0.6 Description User Impact Resolution Changing Radius Timeout from Web interface inadvertently changes Priority to same value. Changing the Timeout Duration field on the RADIUS Server Configuration web page would also change the Priority field to the same value. Correct the API to properl y set the RADIUS priority. ...

  • Dell 6248P - page 23

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 21 CLI Reference Manual Updates Non-Stop Forwarding Title Description nsf no nsf Use this command to enable non-stop forwarding. The “no” form o f the command will disable NSF. Default: Non-stop forwarding is enabled b y default. show nsf Use this comm ...

  • Dell 6248P - page 24

    2 2 System Firmware Version 3. 2.0.6 Title Description show ip ospf neighb or This command has been enhanced to list the per neighbor graceful restart status described in the RFC 4750 MIB. Possible values for Restart H elper Status are as follows: • Helping – This router is acting as a helpful neighbor to this neighbor. • Not Helping – This ...

  • Dell 6248P - page 25

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 23 RADIUS A ccounting Serv ers Title Description radius-server host acct The switches do not support creating accounting server names with the same name although the CLI Reference Manual and User Guide state that it is supported. Default: Not applicable Sp ...

  • Dell 6248P - page 26

    2 4 System Firmware Version 3. 2.0.6 Link Dependenc y Commands Title Description link-dependenc y group [ actio n { up | down } ] Use the action command to control the operational state of the group based on the dependent links state. • up — Causes the group members to change their operational state to be opposite that of the dependent link. ? ...

  • Dell 6248P - page 27

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 25 Known Issues Summary User Impact Workaround Non-configuration file getting loaded to startup-config through HTTP. When the switch reboots and attempts to read an invalid start-up configuratio n file, it will give up and create a default startup configur ...

  • Dell 6248P - page 28

    2 6 System Firmware Version 3. 2.0.6 Summary User Impact Workaround Bridge multicast address is shown as MAC Address format in show running- config buffer when it is configured in IP format. If a user configures the bridge multicast address as an IP address format in VLAN interface mode, it is displayed in the sho w running-config command in M A C ...

  • Dell 6248P - page 29

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 27 Summary User Impact Workaround ISDP updates are not including Voice VLAN Reply TLV whe n Voice VLAN ID on interface is changed. Upon changing configur ation immediat el y after getting the VLAN assigned, DUT stops advertising Voice VLAN repl y T LV in i ...

  • Dell 6248P - page 30

    2 8 System Firmware Version 3. 2.0.6 Known Restrictions and Limitations Layer 2 802.1AB (LLDP) Description User Impact LLDP-MED location and inven t ory transmit TLVs have no effect. The switch does not support configur ing this data so enabling these T LVs has no effect. QoS Description User Impact Traffic permitted by an outbound ACL on one port ...

  • Dell 6248P - page 31

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 29 LACP Description User Impact LAGs Supported Number of LAGs supported: • Up to 18 Dynamic LAGs • 48 Static LAGs Limitations (stack of 12) • Long Timeouts With a minimal CPU load, it takes approximat el y 1.5 minutes with 16 dynamic LAGs and 15 MSTP ...

  • Dell 6248P - page 32

    3 0 System Firmware Version 3. 2.0.6 ICMP Description User Impact IPv4 Fragmentation support The switch is not fr agmenting the datagram and forwards even when the IP MTU of the forwarding Interface is set to a lo wer value (than the datagram size). This is a hardware limitation and is working as designed. T he HW does not allow the IP MTU to be co ...

  • Dell 6248P - page 33

    PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 31 Management CLI Description User Impact radius-server mode commands do not have a "no" form. None of the commands i n radius-server mode support a "no" form except for the msgauth command. To reset values to the default, delete the se ...

  • Dell 6248P - page 34

    3 2 System Firmware Version 3. 2.0.6 Cable Diagnostics Description User Impact Cable Length Diagnostic sh o ws result as 'Unknown' for a port to which Network is connected. Problem is intermittent and only observabl e whe n con necte d to a D-Link DES1008. File Management Description User Impact Error displayed on conso le while applying ...

Manufacturer Dell Category Switch

Documents that we receive from a manufacturer of a Dell 6248P can be divided into several groups. They are, among others:
- Dell technical drawings
- 6248P manuals
- Dell product data sheets
- information booklets
- or energy labels Dell 6248P
All of them are important, but the most important information from the point of view of use of the device are in the user manual Dell 6248P.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Dell 6248P, service manual, brief instructions and user manuals Dell 6248P. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Dell 6248P.

Similar manuals

A complete manual for the device Dell 6248P, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Dell 6248P by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Dell 6248P.

A complete Dell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Dell 6248P - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Dell 6248P, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Dell 6248P, that we can find in the current document
3. Tips how to use the basic functions of the device Dell 6248P - which should help us in our first steps of using Dell 6248P
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Dell 6248P
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Dell 6248P in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Dell 6248P?

Use the form below

If you did not solve your problem by using a manual Dell 6248P, ask a question using the form below. If a user had a similar problem with Dell 6248P it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)