Manual Aquacal 100

60 pages 1.73 mb
Download

Go to site of 60

Summary
  • Aquacal 100 - page 1

    1 1/7/04 A TTENTION INST ALLER: T HIS D OCUMENT IS P URCHASER ’ S P ROPER TY AND IS TO REMAIN WITH THE H EA T P UMP O WNER Pool and Spa Heat Pump Owner ’ s Manual and Installation Guide PN: L TP0051 6/1/05 &7 and Models: 100, 120, & 155 Additional Labels: APS Fox Smart South Beach T r opez HEA TING ONL Y and HEA TING - COOLING ...

  • Aquacal 100 - page 2

    2 1-800-786-7751 NOTES ___________________________________________________________________________________ __________________________________________________________________________________ ___________________________________________________________________________________ ____________________________________________________________________________ ...

  • Aquacal 100 - page 3

    3 TABLE OF CONTENTS WELCOME TO THE TEAM ---------------------------------------------- 5 IMPOR T ANT FEA TURES OF YOUR NEW HEA T PUMP ------------------ 6 HOW A HEA T PUMP WORKS ------------------------------------------ 7 SAFETY INFORMA TION ------------------------------------------------ 8 QUICK ST AR T & STOP ------------------------------- ...

  • Aquacal 100 - page 4

    4 TABLE OF CONTENTS (CONTINUED) MAINTENANCE AND GENERAL OPERA TION...CONTINUED: Heating Ti ps -------------------------------------------------------- 21 - Heating in Cooler W eather -------------------------------------- 21 Pool/Spa Blankets ----------------------------------------------- 21 Pool & Spa Combination Heating --------------------- ...

  • Aquacal 100 - page 5

    5 W elcome eam T to the Dear Owner: C ongratulations on your wise decision to make an AquaCal heat pump part of your home. Since 1981, AquaCal has maintained the worldwide lead in the manufacture of swimming pool & spa heat pumps. Y our new heat pump is not only a great investment, but also the most cost effective method available for heating p ...

  • Aquacal 100 - page 6

    6 Corrosion-Proof Cabinet The cabinet, being made from resilient, UV-Protected ABS material, can never rust, fade or corrode. Y ou can expect the cabinet to retain a like-new appear ance with only an occasional wash down and—if so desired—a quick waxing. PLEASE READ FUR THER T O BECOME F AMILIAR WITH ALL THE FEA TURES, THE SAFE OPERA TION, AND ...

  • Aquacal 100 - page 7

    7 HOW A HEA T PUMP WORKS T HE FOLLOWING EXPLANA TION IS PROVIDED TO HELP YOU IN UNDERST ANDING WHA T TO EXPECT FROM YOUR HEA T PUMP … A Heat Pump Does Not Make Heat… Heat pumps are so extraordinarily efficient because they do not need to produce heat in order to warm pool or spa water . Rather , heat pumps simply transfer heat from the outside ...

  • Aquacal 100 - page 8

    8 Used and maintained properly , your heat pump will provide year-upon- year of safe and economical service. However , as with any mechanical or electrical device, to get the most from your heat pump–while insuring personal safety for you and others–certain operational and maintenance factors must be observed. Likewise, excepting a few minor ow ...

  • Aquacal 100 - page 9

    9 Refrigerant Circuit Service Only by Qualified, EP A Certified T echnician Notice: Heater NOT Rep airable by Owner W ater Chemistry Safety Improper water chemistry can present a serious health hazard. T o avoid possible hazards, maintain Pool/S pa water per standards detailed later in this manual.. Failure to heed the following may result in perma ...

  • Aquacal 100 - page 10

    10 HEA TING- QUICK ST ART & ST OP Getting Started (Quick-Start & Stop Continued Next Page) 1. V erify Electrical Power is Present at Heater: A . Ensure that the unit has electrical power connected; the heater controller display should be illuminated; B. If the display is blank, be certain the electrical breaker , and heater disconnect, are ...

  • Aquacal 100 - page 11

    11 N OTE : T HE HEA T CONTROLLER INCORPORA TES AN ANTI - SHORT CYCLE TIME DELA Y . S HOULD OPERA TION BE INTERRUPTED , REST ART WILL BE DELA YED BY APPROXIMA TEL Y 4- MINUTES . HEA TING-QUICK ST ART & ST OP (continued): (End...Quick-Start & Stop) 6. T o Stop the Heat Pump: A . Select: OFF via the MODE selector . This method of shut down pre ...

  • Aquacal 100 - page 12

    12 HEA TER CONTROLS Control Buttons, Indicator Light s, & Display ( AS INDICA TED BY CIRCLED N UMBERS ) Control Panel Layout (A PPEARANCE V ARIES BY M ODEL ) 1 ) POOL / SPA SELECTOR – Selects either pool or spa thermostat. 2 ) COOLING INDICATOR LIGHT – Indicates unit is cooling. (Note: This light and associated text will not be present on h ...

  • Aquacal 100 - page 13

    13 T HE FOLLOWING CODES WILL BE DISPLA YED AS PA R T OF THE NORMAL OPERA TION OF THE HEA TER : Operational & Programming Codes FLO ..... No W ater Flow Detected. This code appears whenever the circulating pump is off, or when the heater is not receiving correct water flow . OFF ..... System is Off. This code appears whenever heater has been tur ...

  • Aquacal 100 - page 14

    14 HEA TER CONTROLS...continued S t art Up & Setting Operating Controls Owner-Level Programming Instructions (Complete) Covered within this section are features and settings typically accessed first by the installer , and then remaining accessible by the end user (owner) . These features reside at the Level-1 access point within the microproces ...

  • Aquacal 100 - page 15

    15 4 . Selecting Pool/Spa Thermostat Settings: A . Depress the [POOL/SP A] key to toggle between the pool and the spa temperature set points. B. The pool/sp a LED indicator lights, located to the left of the temperature display , will confirm the selected set point. 5. Changing The Pool T emperature Set Point: A . Using the [POOL/SP A] key , select ...

  • Aquacal 100 - page 16

    16 HEA TER CONTROLS...continued S tart Up & Setting Operating Controls (ULC Continued on Next Page) 8. User Lock Code Option [ULC]...continued: A. Selecting UCL Option: 1) Depress either the UP or DOWN ARROW keys; if “LOC” is momentarily displayed flowed by “0”, the ULC feature is enabled. If “0” displays proceed to “6)” of this ...

  • Aquacal 100 - page 17

    17 HEA TER CONTROLS...continued S tart Up & Setting Operating Controls 9. Selecting Call-Flex Pump Options [CFO]: General Information: The Call-Flex option automatically adjusts the run time of the water circulator pump, and heater , based upon changing weather conditions. Without Call-Flex, as weather conditions grow progressively cooler durin ...

  • Aquacal 100 - page 18

    18 MAINTENANCE OPERA TIONAL RECOMMENDA TIONS & The information in this section is written primarily for the Home Owner , but may also apply to servicing dealers or HV AC service centers. This section cont ains information concerning planned maintenance, proper water flow , maintaining proper clearances, as well as other vital information. Pleas ...

  • Aquacal 100 - page 19

    19 • It is important to operate and maintain the filter according to the manufacturer's specifications. As a filter gets dirty , the water flow to the heat pump is reduced. The higher the pressure on the filter gauge, the lower the flow rate. • Similar to a dirty filter , large amounts of debris in the pump basket can reduce water flow . K ...

  • Aquacal 100 - page 20

    20 Maint ain Proper Clearances Around Heater • For maximum efficiency , proper air flow clearances around heater must be maintained. • It is important to keep the area immediately adjacent to the heat pump clear of items such as shrubs and bushes, lawn furniture, chemicals containers, etc. These items can prevent air from circulating fully thro ...

  • Aquacal 100 - page 21

    21 Pool and Sp a Combination Heating... Everything stated for heating a pool applies for heating a spa— only the volume of water being heated is different. All AquaCal heat pumps come equipped with two thermostat s. One thermostat is for the pool and the other is for the spa. Simply position the pool and spa isolation valves as directed by your i ...

  • Aquacal 100 - page 22

    22 Calculating Initial Heating Time The time it takes to initially warm your pool or spa depends on several factors. First, determine how many gallons of water are to be heated. Knowing this, you can then compute the equivalent pounds of water involved, and the BTU's necessary to heat the volume of water to the desired temperature. Next, find ...

  • Aquacal 100 - page 23

    23 Seasonal Use & Shut Down During the Swim Season: • During the swim season, even if the pool or spa is not in use, allow water to flow through the heater . Doing so eliminates the need to reposition valves when you do wish to heat the pool or spa. • During periods when heating or cooling is not desired, leave heater controls in the OFF po ...

  • Aquacal 100 - page 24

    24 1. Disconnect all electrical power to the heater; turn OFF circulating pump. 2. At the two (2) connection unions, disconnect the plumbing to the heater (removal is counter- clockwise). 3. Locate the hand drain plug at lower , front corner of heater . See Figure-3 (position may vary between models). Remove plug. 4. Permit all of the water to drai ...

  • Aquacal 100 - page 25

    25 Planned Maintenance Program Just as you would have yearly service performed on your air-conditioning system, regular inspection and maintenance of your AquaCal heat pump will insure highest operating efficiencies—while also protecting your investment—potentially extending the useful life of your heat pump far beyond the warranty period. Our ...

  • Aquacal 100 - page 26

    26 Heat Pump Fails to Operate... Is the display illuminated? If not, ensure the main breaker (located at the power supply panel) and the disconnect switch (located near the heat pump) are both turned ON. Is the code “FLO” displayed? If so, check to be sure that the circulating pump is operating and the filter is clean. There may also be a valve ...

  • Aquacal 100 - page 27

    27 TROUBLESHOOTING FLOWCHART Heat Pump Fails to Operate I s t he heater operati ng c orrec t ly ? I s t he heat er operat ing c orrec t ly ? I s t he heater operat ing c orrec t l y ? I s t he heat er operat ing c orrec t l y ? T he heater is equipped w it h a f iv e m inut e delay . W ait at leas t f iv e minut es t o allow th e ti me r to r ese t ...

  • Aquacal 100 - page 28

    28 TROUBLESHOOTING FLOWCHART STA RT I s t he ai r being dis c har ged out of t he t op of t he heat er 9-12 degrees c ooler t han t he out s ide air? ST A RT I s t he ai r being dis c harged out of t he t op of t he heat er 9-12 degrees c ooler t han t he out s ide air? I s t he pool pum p t im er s et t o allow ex t ended operat i on of t he heat ...

  • Aquacal 100 - page 29

    29 TROUBLESHOOTING FLOWCHART W ater Coming from Heat Pump ST A R T H as t he "H eating" lamp been illuminated? ST A RT H as t he "Heat ing" lamp been illuminated? S hut off W ater P um p a n d Ca l l Aq u a Ca l f o r A ssistance: 800-786-7751 S hut off W ater P um p a n d Ca l l Aq u a Ca l f o r A ssistance: 80 0-7 86 -77 51 W ...

  • Aquacal 100 - page 30

    30 ...

  • Aquacal 100 - page 31

    31 Models 100, 120, & 155 HEATING ONLY and HEATING - COOLING DEALER-SPECIFIC INFORMA TION FOLLOWS Installation Specifications Controls Configur ation & ...

  • Aquacal 100 - page 32

    32 DEALER-SPECIFIC TABLE of CONTENTS GENERAL SAFETY INFORMA TION ------------------------------------ 34 DA T A PLA TE NOMENCLA TURE ----------------------------------------- 34 HEA TER SPECIFICA TIONS -------------------------------------------- 35 Physical Characteristics (dimensional drawings) ----------------- 35 P erformance, Size, W eight, El ...

  • Aquacal 100 - page 33

    33 INST ALLA TION INSTRUCTIONS (continued): Electrical Requirements ------------------------------------------- 44 General Requirements ------------------------------------------ 44 Code-Specific Requirements ----------------------------------- 44 Connecting External Controllers -------------------------------- 44 Sizing the Electrical Service ---- ...

  • Aquacal 100 - page 34

    34 Notice: Heater NOT Rep airable by Owner Refrigerant Circuit Service Only by Qualified, EP A Certified T echnician 1 2 3456 7 8 9 1 0 1 1 1 2 AT 1 2 0 A R A E W N A CURRENT RELEASED REVISION A - INI TIAL RELEASE BRAND H = HeatW ave OPTI ONS AT= AeroTe mp N-NO NE SB = So ut hBea c h TZ = Tropez CABINET COLOR W - CRÈME B - BLACK CAPACI T Y REFR IG ...

  • Aquacal 100 - page 35

    35 SPECIFICA TIONS Physical Characteristics 100 & 120 M ODELS 155 M ODELS ...

  • Aquacal 100 - page 36

    36 SPECIFICA TIONS -Performance/Size/Weight- -W ater/Electrical Requirement s- 1 0 0 - H e a tin g O n ly M o de ls 100A HDE 100BH DE 10 0DHD T 100HH DT BTU - 80 %RH A i r º F / W ater ºF… 80/80 90,000 90,000 73,000 73,000 CO P 5.8 5.8 5.5 5.5 Volt age/H z/ Phase 2 08- 230/60/1 208-230/60/3 380-415/50/3 200-240/50/1 M i n. Cir cui t Am paci t y ...

  • Aquacal 100 - page 37

    37 SPECIFICA TIONS -Performance/Size/Weight- -W ater/Electrical Requirement s- * All A-V oltage 120 heaters with model numbers ending in “B”, MCA = 33 1 2 0 - H e a tin g O n ly M o d e ls 120A HDE 120BH DE 120DH DT 120HHD T BTU - 8 0%RH Air º F / Wa ter ºF… 80 /80 109 , 000 109,000 95,000 95,000 CO P 5.6 5.6 5. 5 5.5 Volt age/Hz / Pha se 2 ...

  • Aquacal 100 - page 38

    38 SPECIFICA TIONS -Performance/Size/Weight- -W ater/Electrical Requirement s- 155 - He a t i ng On l y M odel s 155AH DE 155BH DE 155DH DT 155G HDE BT U - 80% R H Air ºF / Water ºF… 80/80 127,000 127,000 110, 000 127, 000 C OP 6. 3 6.3 6. 3 6.3 Volt age/Hz / Phase 2 08- 230 / 60/ 1 200-230 / 60/ 3 380-415/50/3 460/ 60/ 3 M in. C ir cui t Am pa ...

  • Aquacal 100 - page 39

    39 Required Inst allation Clearances Code Required Clearances: In addition to the previously stated clearance requirements, follow all applicable local, state, and national requirements relative to spacing from other objects or equipment. Placement of Heater Indoor installations can be problematic, and for that reason are discouraged. However , if ...

  • Aquacal 100 - page 40

    40 Irrigation, Rainwater Runoff, and Landscape Features • Place the heat pump away from direct rain runoff from roofs. If roof slope directs runoff into the heater , a gutter or rain shield will be required on the roof edge above the heat pump. • Relocate or adjust irrigation to avoid water spray directly onto the heat pump. • Do not locate t ...

  • Aquacal 100 - page 41

    41 Plumbing Requirement s Overview When planning plumbing system layout, reference the plumbing schematics within this section as a guide to the sequence of equipment, valves, fittings, etc. The plumbing configurations for typical installations are diagrammed. In operation, it is imperative the heat pump receive water flow within the minimum-maximu ...

  • Aquacal 100 - page 42

    42 Plumbing Schematic–Flow Exceeding 70-GPM Plumbing Requirement s (continued) INST ALLA TION Plumbing Schematics–Flow 20 to 70-GPM T YPICAL P OOL - F LOW LESS THAN 70- GPM P OOL /S PILL O VER S PA - T WO P UMP S YSTEM H EA T P UMP WITH S OLAR P ANELS P OOL /S PILL O VER S PA - O NE P UMP S YSTEM Bypass Check V alve T YPICAL P OOL - F LOW G REA ...

  • Aquacal 100 - page 43

    43 Plumbing Schematics–Flow 20 to 70-GPM (continued) For proper operation and maximum ef ficiency , piping coming from the pump and filter MUST be con- nected to the "IN" port of the heater . Likewise, connect piping returning to the pool/spa to the "OUT" port of the heater . See drawing below . PLUMBI NG CONNECTION D ETAIL Fr ...

  • Aquacal 100 - page 44

    44 General Requirement s • Locate the equipment disconnect means within 3-feet of the heater ’s electrical enclosure, or as close to the heater as possible. Always satisfy applicable codes and standards. • AquaCal heat pumps are designed for copper conductors, only . • In sizing power wiring, be especially aware of up-sizing requirements ne ...

  • Aquacal 100 - page 45

    45 • AquaCal 100, 120, and 155 model heat pumps have two (2) identical data plates affixed: one can be found outside the unit, on right front corner; the second data plate is located behind the front access panel, on the electrical enclosure cover . • Refer to either equipment data plate for unit-specific electrical power supply requirements. ? ...

  • Aquacal 100 - page 46

    46 1. Entering Service Menu: A . T o enter the service menu, Simultaneously depress and hold both the [UP ARROW] and [DOWN ARROW] keys until [CF1] (Celsius / Fahrenheit) code appears. (Note: if “000” displays, the User Lock Code is enabled, and the ULC pass code must be entered before proceeding. See Owner-Level Operating Instructions, page-14: ...

  • Aquacal 100 - page 47

    47 2. Time Delay [dEL]: A . With the [dEL] (4 minute time delay) code message displayed use the [UP] or [DOWN] arrow key to select either “1” to allow the time delay to remain active or “0” to deactivate the time delay . Not pressing depressing any buttons for 15 seconds will allow the controller to save the selection and return to the norm ...

  • Aquacal 100 - page 48

    48 4. W ater Sensor Calibration...continued: C . Follow the steps 1a . through 1d . above to enter the service menu. Once [dEL] is displayed, press the [POOL/SP A] key until the display shows [tSC] (Water T emperature Calibration). Using either the [UP] or [DOWN] arrow keys, calibrate the water temperature sensor by increasing or decreasing the num ...

  • Aquacal 100 - page 49

    49 Controls Configuration & Adjustments... Level-2 Microprocessor Programming...continued: 5. Defrost Sensor Calibration...continued: H . Once the correct temperature value has been selected not pressing depressing any buttons for 15 seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the [P ...

  • Aquacal 100 - page 50

    50 Controls Configuration & Adjustment s... Level-2 Microprocessor Programming...continued: 7. Pool Dead Band Differential...continued: C . Once the desired dead band value has been selected, not pressing depressing any buttons for 15-seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the { ...

  • Aquacal 100 - page 51

    51 Controls Configuration & Adjustments... Microprocessor Factory Default Settings Level –1 and Level-2 Default Settings Menu Cod e Descrip tio n Def ault Value Range Level-1 [CF1 ] C elsius/Fahrenh eit 1 0 / 1 Level-1 [U LC] User L ock Code 0 0 / 1 Lev e l- 1 [ EL C] Ent e r Lo c k Co de 0 00-9 9 Level-1 [CFO] Call / Fl ex 0 0 / 1 / 2 Level- ...

  • Aquacal 100 - page 52

    52 M essage Er ror D escrip tion Possi ble caus e [dPO] D efrost Sensor Open Cut or l oose sen sor wiring [PO] W ater Tempera ture Sensor Open Cut or l oose sen sor wiring [dPC] Defrost Sen sor Shorted Short cir cuit in de frost s ensor wiri ng or de fective sensor. [P C] W ater Tempera ture Sensor Shorted Short cir cuit in w ater te m peratur e se ...

  • Aquacal 100 - page 53

    53 1. Apply electrical power to the heater . 2. Review the available modes by repeatedly pressing the [MODE] key A. Heat-Only Models: The [MODE] key functions should appear as: [OFF] and [HEA]. B. Heat-Cool Models (Icebreakers): The [MODE] key functions should appear as: [OFF], [HEA], [COO], and [AHC]. 3. If the above modes do not display correctly ...

  • Aquacal 100 - page 54

    54 Controls Configuration & Adjustment s... Microprocessor Mode Jumper Positioning...continued: ...

  • Aquacal 100 - page 55

    55 Defrost Systems- Described DEFROST CYCLE (HEA T & COOL UNITS): The microprocessor controller , in conjunction with the defrost sensor , constantly monitors the heater ’s evaporator (air-coil) temperature. Should the controller sense ice or frost has formed on the evaporator , sufficient in amount as to af fect the heater ’s performance, ...

  • Aquacal 100 - page 56

    56 W ater Flow (Pressure) Switch Adjustment Occasionally , plumbing system design features will create a situation whereas the heater will abnormally cycle on the water flow circuit. This situation will be evident if the circulator pump is operating, the filter is clean, and all water valves are set to flow water through the heater– but the error ...

  • Aquacal 100 - page 57

    57 T o Complete the Adjustment Procedure– Either Brand Switch: 1. With electrical power remaining ON to the heater and heater operating, shut off the power to the circulating pump. If the switch has been correctly adjusted, when the water pump stops, the heater will shut of f and the “FLO” code will display . CAUTION: If the heater continues ...

  • Aquacal 100 - page 58

    58 What W e Need to Know When Y ou Call Us If you should need to call AquaCal for service or part s, please have the follow- ing information ready: Model: ________________________________ Serial Number: __________________________ Installation Date: ________________________ Having the above information ready will speed up the service process and all ...

  • Aquacal 100 - page 59

    59 NOTES ___________________________________________________________________________________ __________________________________________________________________________________ ___________________________________________________________________________________ _________________________________________________________________________________ ________ ...

  • Aquacal 100 - page 60

    60 2737 24th St. North St. Petersburg, FL 33713 1-800-786-7751 ...

Manufacturer Aquacal Category Heat Pump

Documents that we receive from a manufacturer of a Aquacal 100 can be divided into several groups. They are, among others:
- Aquacal technical drawings
- 100 manuals
- Aquacal product data sheets
- information booklets
- or energy labels Aquacal 100
All of them are important, but the most important information from the point of view of use of the device are in the user manual Aquacal 100.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Aquacal 100, service manual, brief instructions and user manuals Aquacal 100. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Aquacal 100.

Similar manuals

A complete manual for the device Aquacal 100, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Aquacal 100 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Aquacal 100.

A complete Aquacal manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Aquacal 100 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Aquacal 100, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Aquacal 100, that we can find in the current document
3. Tips how to use the basic functions of the device Aquacal 100 - which should help us in our first steps of using Aquacal 100
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Aquacal 100
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Aquacal 100 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Aquacal 100?

Use the form below

If you did not solve your problem by using a manual Aquacal 100, ask a question using the form below. If a user had a similar problem with Aquacal 100 it is likely that he will want to share the way to solve it.

Copy the text from the picture