    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 1of 36 Operating Instructions Single Conveying Units Compressed Air Venturi Type SSV-05 SSV-05R SSV-052R Bulletin No.: CV6-600 Part No.: 882.00243.00 Technical Service: Service Department Telephone: (800) 423-3183 Edition: 12/05 ...

  • Sterling SSV-05R - page 2

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 2 of 36 The manufacturer retains all rights to change th e information in these operating instructions at any time without notice. We assume no liability for any errors or direct or indirect damage resulting in context with these operating instructions. Copying, translation or ...

  • Sterling SSV-05R - page 3

    Please note that our address and phone i nformation has changed. Please reference this page for updat ed contact information. These manuals are obsolet e and are provided only for their technical information , data and capacities. Portions of these manuals detailing procedures or precautions in the operation, inspection, main tenanc e and repair of ...

  • Sterling SSV-05R - page 4

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 3 of 36 Table of Contents CHAPTER 1: SAFETY INSTRUCTIONS.. . . . . . . . . . . . . . . . . . 4 1.1. Warnings and Symbols ................................................................................................. 5 1.2. Explanations and Information ...................... ...

  • Sterling SSV-05R - page 5

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 4 of 36 Chapter 1: Safety Instructions » These safety instructions apply to anyone near the equipment operation. Please inform everyone near the operating equipment about the direct and indirect hazards associated with the equipment. These operating instructions are to be use ...

  • Sterling SSV-05R - page 6

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 5 of 36 1-1 Warnings and Symbols The following warnings and symbols are used in these operating instructions. » This symbol indicates that a technical term is explained at this point. This symbol indicates DANGER! Death or serious injury is possible if the corresponding instr ...

  • Sterling SSV-05R - page 7

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 6 of 36 1-2 Explanations and Information Various terms and designations are used frequently in these operating instructions to ensure clarity. Therefore, please note that the terms used in the text are defined as follows: • Equipment Equipment can mean an individual unit, a ...

  • Sterling SSV-05R - page 8

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 7of 36 1-3 For Your Safety How to Use This Manual • Please read this manual carefully before initial operation. Understandin g the instructions and equipment will help to avoid injuries as well as damage to equipment. If you have questions, contact the manufacturer. • The ...

  • Sterling SSV-05R - page 9

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 8 of 36 • Check all lines, hoses, and coupling pieces regularly for leakage and damage. Any errors must be eliminated immediately. • The unit may only be used if all corresponding components have been properly connected and are in accordance with relevant regulations. • ...

  • Sterling SSV-05R - page 10

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 9 of 36 1-4 Unit Safety • The unit may ONLY be used for conveying cylindrical plastic granules and regrind on injection molding machines. • NEVER change the settings unless you are able to foresee the consequences. • Use ONLY original manufacturer parts. • Follow a reg ...

  • Sterling SSV-05R - page 11

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 10of 36 Chapter 2: Inst allation » These installation instructions are intended for people with skills in electrical and mechanical areas due to their training, experience and received instructions. Personnel using these installation instruction s must be educated about regul ...

  • Sterling SSV-05R - page 12

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 11 of 36 2-1 General Information Unpack all parts of the single conveyor unit and make sure that every thing is available: • conveyor hopper with level sensor (1) • control and maintenance unit (2) • one venturi assembly (3)  • one section of vinyl flexible hose (4) ...

  • Sterling SSV-05R - page 13

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 12 of 36 2-2 Installing the Conveyor Hopper The single conveyor unit is insensitive to shocks and can be installed d irectly on the processing machine. Make sure that all connections are tight so that the conveying performance is not impaired. The conveyor hopper is equipped w ...

  • Sterling SSV-05R - page 14

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 13 of 36 2-3 Installing the Control and Maintenance Unit Install the control and maintenance unit at a freely accessible site. Check the length of the connection cable and the length of t he supplied hoses to the venturi assemblies. During installation, check the length of the ...

  • Sterling SSV-05R - page 15

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 14 of 36 2-4 Connecting the Comp ressed Air Supply Before connecting the compressed air supply, check the following:  Check compressed air piping for correct installation and assembly.  Check the fittings, length and quality of the hose connections for agreement with req ...

  • Sterling SSV-05R - page 16

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 15 of 36 2-5 Electrical Connection The operating voltage is 110 V, AC, PE, 50/60 Hz. Special voltages available by request. The connected load is approximately 15 W. The connection is made using a mains connector. A separate protection of the socket is not necessary.  Conne ...

  • Sterling SSV-05R - page 17

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 16of 36 Chapter 3: Functional Description  3-1 Method of Functioning The single conveyor unit works according to the Venturi Principle. An external compressed air supply is needed. A venturi meter (A) is integrated in the venturi assembly. The venturi meter aspirates the ma ...

  • Sterling SSV-05R - page 18

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 17 of 36 3-2 Control and Maintenance Unit A. The unit is switched ON and OFF at the control and maintenance unit. B. At the regulator, the operating pressure is adjusted. A water separator is integrated. C. Regularly inspect the compressed air filter to make sure that it is cl ...

  • Sterling SSV-05R - page 19

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 18of 36 This chapter is intended for t he operating personnel of the equipment. General knowledge of operating c onveyor units is required. The functional description must be read and understood. Make sure that in each ca se the operating personnel are sufficiently informed. C ...

  • Sterling SSV-05R - page 20

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 19 of 36 4-3 Basic Setting of the Filling Level in the Conveyor Hopper The filling level in the conveyor hopper is mainly determined by the level sensor. Figure 6: Conveyor Hopper Filling Level Too Low 1. Using a screwdriver, turn the adjustment screw of the level sensor (A) ? ...

  • Sterling SSV-05R - page 21

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 20 of 36 Fine Adjustment of the Filli ng Level in the Conveyor Hopper During operation, use a screwdriver to carefully turn the adjustment screw (A) of the level sensor until the desired filling level is reached. If the filling level in the conveyor hop per cannot be lowered f ...

  • Sterling SSV-05R - page 22

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 21of 36 Chapter 5: Maintenance This chapter is intended for persons with skills in electrical and mechanical areas due to their training and experience. Personnel using the information in this chapter m ust be educated about accident prevention, operating conditions, and safet ...

  • Sterling SSV-05R - page 23

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 22 of 36 5-1 Maintenance Intervals Check the setting of the pressure regulator. Empty the water separator. Daily: Check danger signs on the unit for legibility and completeness. Clean the cartridge filter and screen (depending on accumulation of dust). Blow out the filter from ...

  • Sterling SSV-05R - page 24

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 23 of 36 5-2 Cleaning/Replacing the Filter Cartridge Switch the unit OFF . Disconnect the main electrical plug. Fi g ure 8: XS V -05/R Fi g ure 7: XS V -05 ...

  • Sterling SSV-05R - page 25

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 24 of 36 Disassembly 1. Remove the filter cartridge (A). 2. Blow out the filter cartridge (A) from the inside out using compressed air or replace the filter. 3. Open the toggle-type fastener (B) and fold the hopper lid upward (C). 4. Check the screen (D) within the lid for mat ...

  • Sterling SSV-05R - page 26

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 25 of 36 5-4 Troubleshooting PROBLEM REMEDY (See Test Steps Below) The unit is not conveying and is not active. A, B, G, H The unit is not conveying; the compressed air valve is switched when the device is switched on. C, F The unit is not conveying; the compressed air is flow ...

  • Sterling SSV-05R - page 27

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 26 of 36 -Notes- ...

  • Sterling SSV-05R - page 28

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 27of 36 Chapter 6: T echnical Dat a Maximum througput: 330 lbs/h (149.7 kg/hr) Weight: Approx. 6.61 lbs. (3 kg) Operating voltage: 110 V, AC, PE, 50/60 Hz (standard) Special voltage on request Connected load: Approx. 15 W Total noise level: < 75 dB (A) Compressed air supply ...

  • Sterling SSV-05R - page 29

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 28 of 36 6-1 Dimension Sheet XSV-05 ...

  • Sterling SSV-05R - page 30

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 29 of 36 XSV-05/R Dimensions and data are not binding. All dimensions are in mm (in. ). All data are subject to change. 1.25” OD ...

  • Sterling SSV-05R - page 31

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 30 of 36 XSV-05/2R s Dimensions and data are not binding. All dimensions are in mm (in. ). All data are subject to change. 1.25” OD ...

  • Sterling SSV-05R - page 32

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 31 of 36 6-2 Spare Parts Lists XSV-05 ...

  • Sterling SSV-05R - page 33

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 32 of 36 . XSV-05R ...

  • Sterling SSV-05R - page 34

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 33 of 36 XSV-05/2R ...

  • Sterling SSV-05R - page 35

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 34 of 36 Spare Parts List (See figures on previous pages for parts location) Position ID Number Designation 1 CT98171 Filter cartridge 2 CT 18491 Screen (XSV-05 only) 2 CT 29252 Screen (XSV-05R or XSV-05/2R) 3 CT 31160 Lid gasket (XSV-05 only) 3 CT 34161 Lid gasket (XSV-05R or ...

  • Sterling SSV-05R - page 36

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 35 of 36 6-3 Quick Start Guide –XSV Venturi Loader Unpack all parts. Check for the following: • Conveying hopper with level sensor • Control and maintenance unit • Venturi assembly • Vinyl flexible hose • Compressed air hose • Operating instructions • Mount the ...

  • Sterling SSV-05R - page 37

    XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 36 of 36 6-4 Technical Assistance Parts Department Call toll-free 7am–5pm CST [ 800 ] 423- 3183 or call [ 630 ] 595-1060, Fax [630] 475-700 5 The ACS Customer Service Group w ill provide your compa ny with genuine OEM quality parts manufactured to engi neering design specifi ...

Manufacturer Sterling Category Air Compressor

Documents that we receive from a manufacturer of a Sterling SSV-05R can be divided into several groups. They are, among others:
- Sterling technical drawings
- SSV-05R manuals
- Sterling product data sheets
- information booklets
- or energy labels Sterling SSV-05R
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sterling SSV-05R.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sterling SSV-05R, service manual, brief instructions and user manuals Sterling SSV-05R. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sterling SSV-05R.

Similar manuals

A complete manual for the device Sterling SSV-05R, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sterling SSV-05R by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sterling SSV-05R.

A complete Sterling manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sterling SSV-05R - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sterling SSV-05R, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sterling SSV-05R, that we can find in the current document
3. Tips how to use the basic functions of the device Sterling SSV-05R - which should help us in our first steps of using Sterling SSV-05R
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sterling SSV-05R
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sterling SSV-05R in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sterling SSV-05R?

Use the form below

If you did not solve your problem by using a manual Sterling SSV-05R, ask a question using the form below. If a user had a similar problem with Sterling SSV-05R it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)