Manual Minuteman UPS MCP 10001

20 pages 0.22 mb
Download

Go to site of 20

Summary
  • Minuteman UPS MCP 10001 - page 1

    Continuous Power Series User ’ s Manual MCP 6001 MCP 10001 ...

  • Minuteman UPS MCP 10001 - page 2

    TABLE OF CONTENTS 1. INTRODUCTION 1 1.1 Explanation of symbols 1 1.2 System description 1 1.3 Product specification 2 Electrical specifications 2 Operating environment 2 Mechanical specification 2 1.4 Switches and displays 3 1.5 Safety 4 1.6 Communication port 6 1.7 RS232 interface 6 2. INST ALLA TION AND OPERA TION 6 2.1 Unpacking and inspection 6 ...

  • Minuteman UPS MCP 10001 - page 3

    1. INTRODUCTION 1.1 EXPLANA TION OF SYMBOLS Some or all of the following symbols may be used in this manual or may appear on your unit. Please take a moment to familiarize yourself with these symbols and their associated meanings. Page 1 1.2 SYSTEM DESCRIPTION The MCP SERIES UPS is an advanced True On-Line sinewave Uninterruptible Power Supply (UPS ...

  • Minuteman UPS MCP 10001 - page 4

    Page 2 Power Rating Model No. Freq. (Hz) Input Output V oltage V oltage Current Current 6KV A 4.2KW MCP 6001 50/60 170-276 VA C 50/60 170-276 VA C 120, 120/120, 208, 120/208, 240, 120/240V 120, 120/120, 208, 120/208, 240, 120/240V 10KV A 7KW MCP10001 56A 50, 25/25, 28.8, 25/28.8, 25, 25/25A 83.3, 41.7/41.7, 48.1, 41.7/48.1, 41.7, 41.7/41.7A 33A 1.3 ...

  • Minuteman UPS MCP 10001 - page 5

    MCP 6001 Front View MCP 10001 Front View MCP Control Panel MCP 10001 Rear View MCP 6001 Rear View Page 3 1.4 SWITCHES AND DISPLA YS ◆ ON/OFF switches: Push the “ ON “ button until the alarm sounds to turn on UPS. Push “ OFF “ button until the alarm sounds to turn off UPS. ◆ LINE LED: This light is on when the incoming AC line is normal. ...

  • Minuteman UPS MCP 10001 - page 6

    IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS! Page 4 W ARNING: CHANGES OR MODIFICA TIONS TO THIS UNIT NOT EXPRESSL Y APPROVED BY THE P ARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER’S AUTHORITY TO OPERA TE THE EQUIPMENT . 1.5 Safety IMPORT ANT SAFETY INSTRUCTIONS This manual contains important instructions for MCP SERIES series th ...

  • Minuteman UPS MCP 10001 - page 7

    Page 5 Model Number Battery V oltage 240 VDC MCP6001 MCP10001 CAUTIONS: The UPS contains voltages which are potentially hazardous. All repairs should be performed by qualified service person- nel. The UPS has its own internal energy source (battery). The output may be ‘hot” even when the UPS is not connected to the AC supply . The voltage the i ...

  • Minuteman UPS MCP 10001 - page 8

    Page 6 1.6 COMMUNICA TION PORT The UPS provides an RS232 serial port to communicate with a host computer . The host computer can monitor the UP S through this RS232 communication port. The data format of RS232 is as follows: Baud Rate : 2400 bps Data Length : 8 bits Ending Code : 1 bit Parity Bit : none 1.7 RS-232 IINTERF ACE The following is the p ...

  • Minuteman UPS MCP 10001 - page 9

    Page 7 2.3 WIRING DESCRIPTION The wiring method for the MCP SERIES is shown in Figure A. Figure A - Wiring Diagram for MCP 6001, & MCP10001 REAR VIEW Wiring Instructions: 1. Utility panel circuit breaker required is 35A or larger 2. Utility wire guage must be 8 guage or larger . 3. Connect utility per drawing. 4. Connect output load connections ...

  • Minuteman UPS MCP 10001 - page 10

    OUTPUT VOL T AGE CONFIGURA TIONS Page 8 OUTPUT CONFI GURA T I ON #1 = 1 20 VAC L1 L2 L3 L4 N G 1 2 0 V A C OUTPUT CONFIGURAT I ON #2 = 120 VAC / 120 VAC L1 L2 L3 L4 N G 1 2 0 V A C 1 2 0 V A C OUTPUT CONFIGURA TI ON #3 = 208 VAC L1 L2 L3 L4 N G 2 0 8 V A C OUTPUT CONFIGURA TI ON #4 = 120 VA C / 208 VAC L1 L2 L3 L4 N G 1 2 0 V A C 1 2 0 V A C 2 0 8 ...

  • Minuteman UPS MCP 10001 - page 11

    ◆ When using an isolation tranasformer , ensure that the load is balanced. ◆ When using #6 AWG wire 2 in. are required for wire bending space opposite the terminals. 1 1/2 in. for #8 AWG. 3 in. for #3 AWG and #4 AWG. 3 1/2 in. for #2 AWG. ◆ For 6KV A output configuration #1, #2, #3, #4, #5, #6, and #7 use #6 A WG, 75ºC copper wire. For 10KV ...

  • Minuteman UPS MCP 10001 - page 12

    3. TROUBLESHOOTING The TROUBLESHOOTING CHART covers most of the difficulties you may encounter under normal working conditions. OBT AINING SERVICE If the UPS requires service; 1. Use the TROUBLESHOOTING CHART to eliminate obvious causes. 2. V erify that no circuit breakers are tripped. A tripped circuit breaker is the most common problem. 3. Call y ...

  • Minuteman UPS MCP 10001 - page 13

    1. ST ART-UP 1. T urn on Input breaker and the Battery breaker (10KV A) on the rear panel after checking the power wiring. The cooling fans should be rotating and the control panel should show the display as below . Page A1 APPLICA TION NOTES Figure 1.1-1 Bypass Mode (Load LED display depends of load level) 2. Then press the “ | ” button. After ...

  • Minuteman UPS MCP 10001 - page 14

    Page A2 3. DISPLA YS AND ALARMS 1. Load level and battery capacity is represented by 5 LEDs on the upper half of control panel (the 6th LED means F AUL T). (A). When the UPS is in the On-Line mode, the 5 LEDs represent load level. They denote 0%~35%, 35%~55%, 55%~75%, 75%~95% and 95%~105% (from buttom to top) of maximum load capacity . If the load ...

  • Minuteman UPS MCP 10001 - page 15

    Page A3 4. An alarm sounds continuously during an over-temperature condition. Figure 3.4-1 Line Mode Figure 3.4-2 Battery Mode 5. Display and alarm for overload. The alarm will sound once every 0.5 seconds during an overload condition. While in inverter mode, the alarm can be silenced by pressing the “OFF” button. In the Battery T est mode, the ...

  • Minuteman UPS MCP 10001 - page 16

    Page A4 7. Alarm for abnormal input voltage. A ) During Start-up, the Line LED will flash if the input voltage drops below 185V or above 261V . Pressing the “ | ” button will not switch the UPS from Bypass Mode to Inverter Mode. (B) During operation, the UPS will switch from Inverter Mode to Battery Mode if the input voltage drops below 170V or ...

  • Minuteman UPS MCP 10001 - page 17

    Page A5 LIMITED PRODUCT W ARRANTY Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of two years from the date of original purchase by the end user . For equipment sites within the United States and Canada, this warranty cove ...

  • Minuteman UPS MCP 10001 - page 18

    Page A6 DECLARA TION OF CONFORMITY Application of Council Directive(s): 89/336/EEC, 7/23/EEC Standard(s) to which Conformity is Declared: EN50091-2, EN50091-1_ Manufacturer’s Name: Para Systems, Inc. (MINUTEMAN UPS)_ Manufacturer’s Address: 1455 LeMay Drive Carrollton, T exas 75007 USA T ype of Equipment: Uninterruptible Power Supplies (UPS) Mo ...

  • Minuteman UPS MCP 10001 - page 19

    Notes: ...

  • Minuteman UPS MCP 10001 - page 20

    Para Systems, Inc. 1455 LeMay Dr . Carrollton, TX 75007 Phone: (972) 446-7363 Fax: (972) 446-901 1 Internet: www .minutemanups.com UPS Sizing: sizemyups.com P/N 34000139 Rev: 1 ...

Manufacturer Minuteman UPS Category Power Supply

Documents that we receive from a manufacturer of a Minuteman UPS MCP 10001 can be divided into several groups. They are, among others:
- Minuteman UPS technical drawings
- MCP 10001 manuals
- Minuteman UPS product data sheets
- information booklets
- or energy labels Minuteman UPS MCP 10001
All of them are important, but the most important information from the point of view of use of the device are in the user manual Minuteman UPS MCP 10001.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Minuteman UPS MCP 10001, service manual, brief instructions and user manuals Minuteman UPS MCP 10001. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Minuteman UPS MCP 10001.

A complete manual for the device Minuteman UPS MCP 10001, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Minuteman UPS MCP 10001 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Minuteman UPS MCP 10001.

A complete Minuteman UPS manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Minuteman UPS MCP 10001 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Minuteman UPS MCP 10001, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Minuteman UPS MCP 10001, that we can find in the current document
3. Tips how to use the basic functions of the device Minuteman UPS MCP 10001 - which should help us in our first steps of using Minuteman UPS MCP 10001
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Minuteman UPS MCP 10001
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Minuteman UPS MCP 10001 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Minuteman UPS MCP 10001?

Use the form below

If you did not solve your problem by using a manual Minuteman UPS MCP 10001, ask a question using the form below. If a user had a similar problem with Minuteman UPS MCP 10001 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)