Manual Friedrich CP18C30

16 pages 0.93 mb
Download

Go to site of 16

Summary
  • Friedrich CP18C30 - page 1

    6 61214 17 (4- 0 6) O p e r a t i n g G u i d e C o m p a c t Pr o g r a m m a b l e R o o m A i r C o n d i t i o n e r w i t h re m o te c o n t r o l C P18C30 Whene ver yo u call to req uest ser vice on your appliance, you w ill need to pro vide you r compl et e mod el numb er and serial number . Y ou can find this informati on on the model and ...

  • Friedrich CP18C30 - page 2

    2 T a b l e o f C o n t e n t s Air C ondit ioner S afet y ...................................................................................................................................................... 2 Inst alla t ion Requirement s ............................................................................................................ ...

  • Friedrich CP18C30 - page 3

    3 3 I n s t a l l a t i o n R e q u i r e m e n t s T o o l s a n d P a rt s Gather the r equired tools and parts befor e starting installation. Read and follow the instructio ns provided with any tools listed here . T o ol s Ne ed ed T hr ou gh -t h e- w al l i ns ta l la t i on : In addition to the tools list ed above, the following tools are nee ...

  • Friedrich CP18C30 - page 4

    4 4 W in do w in st al la ti o n Window op en ing measureme nts : 30"mi n. t o 40" ma x. ( 76.2 c m to 101.6 cm ) op ening wi dt h. 20" mi n. ( 50.8 c m ) op en ing height . T hr ou gh -t h e- wa l l i ns ta l la ti on Th e w all opening measuremen ts should b e: Widt h: 30" (76.2 c m) pl us twi c e t hic kness of wood use d t o ...

  • Friedrich CP18C30 - page 5

    5 5 R ec om men de d gr ou nd in g me th od Th is air cond i tioner mu st b e ground ed. This ai r co nd itio ner is equip p ed with a po we r supp ly c ord havi ng a ground ed 3 pr ong p lug. T o minimize p ossib le s hoc k haza rd , the c ord mu st be p lugged int o a mati ng, grou nded 3 p rong out let , ground ed in accor d anc e with al l lo c ...

  • Friedrich CP18C30 - page 6

    6 6 I n s t a l l a t i o n I n s t r u c t i o n s U n p a c k i n g R em o ve p ac ka gi ng m a te ri al s � Remove and dispose of/ recycle packaging materials. Remove tape and glue r esidue from surfaces befor e tur ning on t he air conditioner . Rub a smal l amount of liquid d ish soap over the adhesive w ith your fingers. Wipe with warm wate ...

  • Friedrich CP18C30 - page 7

    7 7 W i n d o w I n s t a l l a t i o n ( o n s o m e m o d e l s ) NOTES: � Handle air conditioner gently . � Be sure y our air conditioner cabinet does not fall out of the opening during installation or r emoval. � The place wher e the power cord exits the air conditioner should be no mor e than 4 ft (122 cm) from a gr oun ded 3 prong ou tl ...

  • Friedrich CP18C30 - page 8

    8 8 I ns ta l l C ab in et i nt o W in d ow � Handle air conditioner gently . � Be sure y our air conditioner cabinet does not fall out of the opening during installation or r emoval. � The place wher e the power cord exits the air conditioner should be no mor e than 4 ft (122 cm) from a gr oun ded 3 prong ou tlet. � Do not block the louver ...

  • Friedrich CP18C30 - page 9

    9 9 2. Using #10 x ⁷⁄₈ " pan-head Phillips scre ws, attach bracket to cabinet. Repeat for other bracket. 3. T urn the adjustment bolt for each bracket until the bolt touches the wall. 4. T urn the locking nut on adjustment bolt to lock in position. C om pl et e I ns ta l la t io n 1. Insert seal behind the top of the lower window sash an ...

  • Friedrich CP18C30 - page 10

    10 10 � Use 1" (2.5 cm) or thicker lu mber for wood frame. 4. Apply wood pr eservative to the outside exposed surf ace. 5. Insert the fra me in the wall opening. Squar e and level frame. 6. Attach frame secur ely to the wall. I ns ta ll C a bi ne t i nt o W o od F ra me 1. Remove top ch annel and both side channels using a ¹⁄₄ " nu ...

  • Friedrich CP18C30 - page 11

    1 1 11 3. Connect gr een ground wir e to cabinet base with ground screw . Position ground wire pointing straight up. Put excess gr ound wire be tween coil and air conditioner cabinet. 4. Push front panel straight on and then lower it sli ghtly to loc k i t into place. 5. Using 2 - #1 0 x ³⁄₈ " r ound-head s cre ws, a ttach bo ttom front o ...

  • Friedrich CP18C30 - page 12

    12 S t a rt i n g Y o u r A i r C o n d i t i o n e r — D i g i t a l C o n t r o l 1. Pre ss P OW E R to t urn o n ai r co nd it io ner . NOTE : Whe n th e u nit is tu rn ed on, it w ill di sp lay th e previous se tti ngs f or th e Mo d e, F an Spee d and t emp e ra t ure. 2. Choose mode. See “ Mode .” 3. Choose fan sp eed . S ee “ Fa n Sp ...

  • Friedrich CP18C30 - page 13

    13 13 T o o pe ra te a ir c on di ti on er w it h r em ot e co nt r ol NOTE: R emote con t rol may vary in a ppe arance. NOTE : T wo AA A b a tt er ies ( inc lud ed) po w er the remote c o nt rol. R eplac e batte ries a ft er 6 mo nt hs of use, or w hen th e re m ot e c ont rol st arts to l ose po wer . T o t ur n th e ai r c on d it io ne r o n o ...

  • Friedrich CP18C30 - page 14

    14 A i r C o n d i t i o n e r C a r e Y our n e w air c o nd iti oner is desig ned to gi ve you many yea rs o f dep endab le service . Th i s sect io n tells you how t o cl ean and ca re for you r air con d it ioner properl y . Call your lo cal auth orized d ealer for an annual checku p . Re m embe r … th e cos t of t his service c all is your r ...

  • Friedrich CP18C30 - page 15

    15 1 5 A ir c on di ti on e r po we r s up pl y c or d tr ip s ( Re se t b ut to n p op s o ut ) � Disturbances in your e lectrical current can trip (Reset button will pop out) the power supply cord. Press and rele ase RESET (listen for click; Reset button will latch and remain in) to resume operation. � Electrical overloading, o verheating, co ...

  • Friedrich CP18C30 - page 16

    Friedrich A ir Conditioning Company P.O. Box 1540 San Antonio, TX 78295 21 0. 35 7.4 400 ww w.f rie dri ch. co m ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PA R T: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product a ...

Manufacturer Friedrich Category Air Conditioner

Documents that we receive from a manufacturer of a Friedrich CP18C30 can be divided into several groups. They are, among others:
- Friedrich technical drawings
- CP18C30 manuals
- Friedrich product data sheets
- information booklets
- or energy labels Friedrich CP18C30
All of them are important, but the most important information from the point of view of use of the device are in the user manual Friedrich CP18C30.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Friedrich CP18C30, service manual, brief instructions and user manuals Friedrich CP18C30. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Friedrich CP18C30.

Similar manuals

A complete manual for the device Friedrich CP18C30, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Friedrich CP18C30 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Friedrich CP18C30.

A complete Friedrich manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Friedrich CP18C30 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Friedrich CP18C30, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Friedrich CP18C30, that we can find in the current document
3. Tips how to use the basic functions of the device Friedrich CP18C30 - which should help us in our first steps of using Friedrich CP18C30
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Friedrich CP18C30
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Friedrich CP18C30 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Friedrich CP18C30?

Use the form below

If you did not solve your problem by using a manual Friedrich CP18C30, ask a question using the form below. If a user had a similar problem with Friedrich CP18C30 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)