Manual Interquartz ID201

27 pages Not applicable
Download

Go to site of 27

Summary
  • Interquartz ID201 - page 1

    Doorphone – ID 201 Doorphone – ID 202 Doorphone – ID 204 User manual INTERQUARTZ ...

  • Interquartz ID201 - page 2

    Conten ts 1 BASIC DESCRIPTION ......... .......... ......... ......... .......... ......... .......... ......... ......... ... 3 1.1 F EATURES ......... .......... ......... ......... .......... ......... ......... .......... ......... .......... ........ 3 1.2 S LI M D OOR P HONE MODEL S ......... .......... ......... ......... .......... ........ ...

  • Interquartz ID201 - page 3

    8 DRILLING MAST ER BOARD ..... ......... .......... ......... ......... .......... ......... .......... . 27 1 Basic descript ion 1.1 Features  Very slim module for surfac e mounting o nly. S upplied in 1, 2 or 4 button variants.  Voice comm unication powered fr om analogue telephon e line only.  Pulse and tone (DT MF) dial  Two 16 digi ...

  • Interquartz ID201 - page 4

    1.2 DoorPhone models Three versions are available : ID 201 -1 butt on ID 202 - 2 bu ttons ID 204 - 4 buttons 2 Installation This com pact unit is fixed by 2 scre ws to the wall. 2.1 Opening, wiring, wall mounting and settings 2.1.1 Name card pane l 1. Every unit is supplied wi th a special key w hich is used to release t he n am e car ds on the fro ...

  • Interquartz ID201 - page 5

    2.1.2 Uncover cont rol eleme nts 4. Push the aluminium s peaker grille down (see figure – 4). 2.1.3 Wiring and wall mounti ng 5. Use the wall mounting template at the end of the manual to m ark the position for the scr ew holes an d cable connection o n the mounting surf ace. Drill th e holes. 6. Feed t he ca ble (an alogue line, power sup ply, l ...

  • Interquartz ID201 - page 6

    (central) and " NC " means contact normally c losed. T he relay contact is isolated fr om the other c ircuits on th e boar d. For t he v ariants of lock connection see th e picture belo w. W iring of standard and magnetic (in verse) lock 7. A special U SB ca ble en ables the doorphone to b e co nnected to a PC for progra mm ing of individ ...

  • Interquartz ID201 - page 7

    The PCB heating has two m ajor benefits. Firstl y, it warm s the board during winter tim e (temperatures under -20 C, most circuits have warrant y operation down to - 20 C) and secondly it helps to protect the PCB ag ainst humidity when ins talled outs ide. 2.1.5 Voice level 10. Voice communic ation – the trimmer position is factor y and should b ...

  • Interquartz ID201 - page 8

    2.2 Location of ID Doorphone components All mounting, control and setting elem ents are located under the speak er front aluminium grille. . PC connec tor SlimDoorPhone fixing screw hole Service switch Loudspeaker MIC-setting of microphone volume TRH – setting of microphone activation level SPK- setting of speaker volum e Heating activation 12V = ...

  • Interquartz ID201 - page 9

    2.3 Changing name cards Name car d panel (2.1.1on page 4) h as spaces to insert printed nam e cards. Insert nam e cards from top (s ee picture). Cards c an easily be printed with pictures as well as text using the included software. The card outline is marked for easy cutting . 2.4 Final closing of ID Doorphone 2.4.1 Covering con trol elemen ts 1. ...

  • Interquartz ID201 - page 10

    3 Doorphon e Services 3.1 Signalling Overview The unit s ignals acoustic c onditions tha t m ay occur du ring operat ion. You can listen to the sig nalling sam ples in the ID Manag er program. Condition Tones Tone frequenc y Pick up line – ▄ – ■ – ▀ – 425-850-1275 Hang up line – ▀ – ■ – ▄ 1275-850-425 Confirm command –? ...

  • Interquartz ID201 - page 11

    from the second group ( p arameter 2 ). The next pr ess of the same button again selects the num ber from the firs t group, etc..…… If the button is pressed af ter the line has been opened (but before the call is ans wered), the unit will hang up for the per iod given by paramet er 54, lift up the line and dia l the other group number. The rela ...

  • Interquartz ID201 - page 12

    4 Parameter progra mming 4.1 Programming from a telephone by DT MF 4.1.1 Entering progra mming mode The SlimDoorPhone ma y be set to programm ing mode in two w ays: 1. by passw ord – d ial the unit‘s num ber (eit her extension number, if connected to a PBX or telephone number, if co nnected to a PSTN line) . T he unit wi ll ans wer ( you will h ...

  • Interquartz ID201 - page 13

    Note 1 . i f you wish to maintain the connection in programming mode (i.e. ex tend the 34 seconds pe riod) then it is necessary to o ccasionally press a key (e.g. * , # or 7). The unit will respond with an error tone but the connection will be kept alive. Note 2. The # si gn is not used in the values for parameters 32 ,33 an d 34, and can be used t ...

  • Interquartz ID201 - page 14

    5 Parameter descr iption 5.1 Direct Dialling – Memories Parameter Value Description Default Exam.1 Exam.2 1 t nn… No. nn under button t - - - t – Button num ber (memor y) [1-4] nn – te lephone number up to 16 di gits to be stor ed. Refer to the table for ot her choices. The num ber stored in param eter 1 is the n umber f or the first group ...

  • Interquartz ID201 - page 15

    Parameter Value Description Default Exam .1 Exam.2 32 hhhhhh External access code in DAY + NIGHT mode - 1212 1324 33 hhhhhh External access code in DAY mode - 2211 2211 34 hhhhhh External access code in NIGHT mode - 1122 1122 hhhhhh – password for rela y closing fr om buttons [2 to 6 dig its] The 3 passwords are controlled b y D ay/Night; the com ...

  • Interquartz ID201 - page 16

    Parameter Value Description Default Exam .1 Exam.2 38 cc Internal access code 2 impulses 66 66 66 cc – comm and from phone to rel ay closing [2 digits] – 2 impulses Parameter Value Description Default Exam.1 Exam.2 39 hhhhhh External access code in DAY + NIGHT mode for 2 impulses 66 66 66 hhhhhh – password for rela y closing from buttons [2 t ...

  • Interquartz ID201 - page 17

    Parameter Value Description Default Exam.1 Exam.2 44 xxxx Password 0000 0000 0000 xxxx – s ervice password for entry to programm ing Parameter Value Description Default Exam.1 Exam.2 45 dd DAY MODE switching 11 11 11 46 nn NIGHT MODE switching 10 10 10 dd – command for D A Y MODE switching [ 2 digits] nn – command for NIGHT MODE switching [2 ...

  • Interquartz ID201 - page 18

    Parameter Value Description Def ault Exam.1 Exam.2 53 w time between button presses 2 2 2 w – m ax. time [sec ] between button presses [range 1-9] - re lay clo sing – if time bet ween t wo next press es is bigger than w time, the code is n ot evaluated corr ectly. - dialling – if the bu tton pressed is the firs t password number for switch cl ...

  • Interquartz ID201 - page 19

    Parameter Value Description Def ault Exam.1 Exam.2 57 t DTMF tone duration (ms) 5 (100ms ) 5 (100ms ) 5 (100ms ) 58 m Space duration between DTMF tones (ms) 5 (100ms ) 5 (100ms ) 5 (100ms ) 59 f Recall duration (ms) 1 (100ms ) 1 (100ms ) 1 (100ms ) 50 p Pause duration (ms) 8 (800ms ) 8 (800ms ) 8 (800ms ) t – DT MF tone duration is det ermined b ...

  • Interquartz ID201 - page 20

    Parameter Value Description Def ault Exam.1 Exam.2 5*2 y Frequency of tone detection 4 4 4 y – s etting range frequency of tone detection from telephone line, value is in next table: y frequency rang e y frequency rang e 1 200-350Hz 7 500-650Hz 2 250-400Hz 8 550-700Hz 3 300-450Hz 9 600-750Hz 4 350-500Hz 0 650-800Hz 5 400-550Hz * 700-850Hz 6 450-6 ...

  • Interquartz ID201 - page 21

    Parameter Value Description Def ault Exam.1 Exam.2 81 Deletes all numbers in group 1 (Day mode) 82 Deletes all numbers in group 2 (Night mode) 83 Default setting only for parameters 3x only 3.. 84 Default setting only for parameters 4x only 4.. 85 Default setting only for parameters 5x only 5.. The parameters 81 an d 82 will delete all numbers stor ...

  • Interquartz ID201 - page 22

    Parametr Value Descript ion Default Exam.1 Exam.2 6 z Acoustic signalling 3 and 9 3 and 9 3 and 9 In default the un it produces acoustic signals. It can occas ionally cause a problem of incorrect detection of tones b y PBX. By changing param eter „ z“ you can s witc h off this acoustic s ignalization. T he values are: z=0 – all signalling is ...

  • Interquartz ID201 - page 23

    36 ss Relay closing time 05 02 05 37 pp Time between 2 impulses 05 05 05 38 cc Internal access code 2 impulses 66 66 66 39 hhh hhh External access code in DAY + NIGHT mode for 2 impulses - - - 41 v Dialling type 0 0 0 42 z Prolong call * * * 43 bb End call 55 55 55 44 x xxx Password 0000 0000 0000 45 dd DAY MODE switching 11 11 11 46 nn NIGHT MODE ...

  • Interquartz ID201 - page 24

    6 * t Delay of line connection (Siemens PBX) 1 1 1 6 z Acoustic signalling 3 and 9 3 an d 9 3 and 9 8# # Default setting executes 8# 1 Setting per exam. 1 executes 8# 2 Setting per exam. 2 executes 81 Deletes all numbers in group 1 (Day mode) 82 Deletes all numbers in group 2 (Night mode) 83 Default setting only for parameters 3x only 3.. 84 Defaul ...

  • Interquartz ID201 - page 25

    switches and heat ing Max. consum ption of lighting through and heat ing 300mA 12V Max. voltage of s witch contac t 48V at I < 1A Max. current of switch contact 2A at U < 30 V Operational tem perature - 20 to + 50° C 6.2 Mechanical dimensions Dimensions W xHxD 104m m x 153mm x 16mm W eight 360g Unit material elox aluminium profile Name car d ...

  • Interquartz ID201 - page 26

    Relay closing time [sec] 36 2 Time between 2 impulses [sec] 37 2 Internal access code 2 impulses 38 2 External access code 2 impulses Day+Night 39 6 Dialling type 1 / 0 41 1 Prolong call *  / # 42 1 End call 43 2 Password 44 4 DAY MODE switching 45 2 NIGHT MODE switching 46 2 Dialling mode 1 / 0 47 1 No. of rings before pick-up 51 1 Maximum call ...

  • Interquartz ID201 - page 27

    8 Drilling master bo ard ...

Manufacturer Interquartz Category Intercom system

Documents that we receive from a manufacturer of a Interquartz ID201 can be divided into several groups. They are, among others:
- Interquartz technical drawings
- ID201 manuals
- Interquartz product data sheets
- information booklets
- or energy labels Interquartz ID201
All of them are important, but the most important information from the point of view of use of the device are in the user manual Interquartz ID201.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Interquartz ID201, service manual, brief instructions and user manuals Interquartz ID201. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Interquartz ID201.

Similar manuals

A complete manual for the device Interquartz ID201, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Interquartz ID201 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Interquartz ID201.

A complete Interquartz manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Interquartz ID201 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Interquartz ID201, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Interquartz ID201, that we can find in the current document
3. Tips how to use the basic functions of the device Interquartz ID201 - which should help us in our first steps of using Interquartz ID201
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Interquartz ID201
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Interquartz ID201 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Interquartz ID201?

Use the form below

If you did not solve your problem by using a manual Interquartz ID201, ask a question using the form below. If a user had a similar problem with Interquartz ID201 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)