  • New Buck Corporation ZCBB - page 1

    New Buck Corporation P.O. Box 69 8000 Hwy. 226 South Spruce Pine, NC 28777 BUCK ST OVE MODEL ZCBB VENTLESS FIREBOX ENCLOSURE FOR GAS-FIRED DECORA TIVE TYPE UNVENTED ROOM HEA TERS FOR USE WITH OPTIONAL WOODEN FLUSH MOUNT MANTEL (FF) AND OPTIONAL WOODEN SURROUND (WS) INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for fu ...

  • New Buck Corporation ZCBB - page 2

    ...

  • New Buck Corporation ZCBB - page 3

    T ABLE OF CONTENTS Safety Information and Warnings ....................................................................................... 3 Installation .................................................................................................................. ......... 5 Firebox and Framing Dimens ions (ZC) (FF) ........................... ...

  • New Buck Corporation ZCBB - page 4

    2 ...

  • New Buck Corporation ZCBB - page 5

    SAFETY INFORMA TION W ARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREF ULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, INSTA LL, OPERATE, OR SERVICE THIS APPLIANCE (FIREBOX ENCLOSURE). Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properl ...

  • New Buck Corporation ZCBB - page 6

    W ARNING DO NOT USE A BLOWER IN SERT, HEAT EXCHANGER INSERT, OR OTHER ACCESSO RY NOT APPROVED FOR USE WITH THIS HEATER. THIS HEATER SHALL NO T BE INSTALLED IN A CONFINED SPACE UNLESS PR OVISIONS ARE MADE FOR ADEQUATE COMBUSTION AND VENTILATION AIR. ”See Page 10, for “Producing Adequate Ventilation”. NOTE: THIS IS A VENTLESS FIREBOX ENCLOSURE ...

  • New Buck Corporation ZCBB - page 7

    INST ALLA TION Your New Buck Ventless Firebox Enclosure may be installed in Residentia l or *After-Market Manufactured Mobile Homes. This appliance may be installed in an *After Market Manufactured Mobile Home, where not prohibited by state or local codes. * (After Market: Completion of sale, not for the purpose of resale from the manufacturer). NO ...

  • New Buck Corporation ZCBB - page 8

    FIREBOX AND FRAMING DIMENSIONS (ZC) & (FF) NOTE: SEE PAGE 10 IF AN OPTIONAL WOODEN FLUSH M OUNT MANTEL FRONT (FF) IS TO BE USED. Figure 2 GAS LINE 33-1/8" 18-15/16" 35-5/8" 36-5/8" 19 3/8" 8 1/16" 10 1/4" 36-5/8" Figure 2 37-5/16" 37-5/16" NOTE: YOUR NEW BUCK CORPORATION VENTL ESS FIREBOX ENCLOS ...

  • New Buck Corporation ZCBB - page 9

    Figure 3 FIREBOX CLEARANCES The firebox may be placed dire ctly on a combustible floor, against a combustible wall at m arked clearances, or on a raised wooden platform. If the firebox is to b e installed on a raised wood en platform, the platform m ust be a continuous level surface. The firebox must be secured in place so it cannot shift positions ...

  • New Buck Corporation ZCBB - page 10

    FINISHING YOUR FIREBOX There is a wide variety of finishing material available for your firebox from formal wall treatments with m arble and mantels, to rustic wood paneling, stone or brick. IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREBOX NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATE RIAL. Non-combustible facing m aterials such as marble, bri ...

  • New Buck Corporation ZCBB - page 11

    MANTEL PROFILES FOR VE NTLESS FIREBOX ENCLOSURE (UNIVERSAL BOX) ZERO CL EARANCE CABINET MUST BE FOLLOWED A 3” 3/4” 3 1/2” 4” B CANOPY STANDOFF COMBUSTIBLE MATERIALS ZCBB MANTEL CLEARANCES MANTEL WIDTH MANTEL HEIGHT (“ A ” inches ) (“ B ” inches above firebox opening) 6.0 14.0 8.0 14.0 10.0 14.0 12.0 16.0 FIGURE 5 9 ...

  • New Buck Corporation ZCBB - page 12

    D DATE REV. BY INSTALLATION INSTRUC TIONS FOR MODEL ZCBB OPTIONAL WOODEN FLUSH MOUNT MANTEL FRONT (FF) (KIT#PAKDMZCBBFF) “NOTE: Follow the framing instructions on page (s) 6 & 7. With the excep tion of the placement of the ZCBB in the framed open ing . The Z CBB must be placed with the front surface of the appliance 1-9/16” out from the fin ...

  • New Buck Corporation ZCBB - page 13

    INSTALLATION I NSTRUCTI ONS FOR MODEL ZCBB OPTIONAL WOODEN SURROUND (WS) (KIT# PAKDMZCBB) CLEARANCES: 1. Sidewall Clearances: Clearances from the side of the firebox opening to any adjacent combustible wall should not be less than 7". See Figure 4 2. Ceiling Clearances: The ceiling height should not be less than 42" from the top of the fi ...

  • New Buck Corporation ZCBB - page 14

    REAR VIEW After assembling the WS you must insert the ZCBB. It is best to insert the ZCBB from the rear of the WS, this gives you more area to hold the ZCBB and re duces the risk of scratc hing the surface of the front area of the base (hea rth) area. Flush and center the ZCBB’s front in the WS. You can attach the ZCBB to the WS with “L” brac ...

  • New Buck Corporation ZCBB - page 15

    This section is used for residential inst allation or mobile home installation. UNCONFINED SPACE: An unconfined space has a minimum air volume of 50 cubic feet for each 1,000 BTU/Hr (4.8m 3 per Kw) input rating of all appliances in the space (Cubic feet equals L ength x Width x Height of space). Include adjoining rooms only if there are doorless pa ...

  • New Buck Corporation ZCBB - page 16

    3. Add the BTU/Hr of all fuel burning appliances in the space. Vent-Free Heater _________________________BTU/Hr. Gas Water Heater* _________________________BTU/Hr. Gas Furnace _________________________BTU/Hr. Vented Gas Heater _________________________BTU/Hr. Gas Fireplace Logs _________________________BTU/Hr. Other Gas Appliance* +________________ ...

  • New Buck Corporation ZCBB - page 17

    VENTILA TION AIR VENTILATION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconf ined sp ace. When venting to an adjo ining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see Options 1 and 2, Figure 6). You can als ...

  • New Buck Corporation ZCBB - page 18

    Figure 7 Ventilation Air From Outdoors W ARNING THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-BURNING APPLIANCES IN YOUR HOME. VENTILA TION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or duc ...

  • New Buck Corporation ZCBB - page 19

    OPTIONAL BLOWER INST ALLA TION The Model ZCBB has an optional MA ZCBB714 blow er kit that can be purchased from your dealer. You will need to follow these steps and the di agram below and the wiring diagram on page 18. NOTE: The receptacle which is provided in the Model ZCBB must be wired into your home (residence) in order to have elec tricity to ...

  • New Buck Corporation ZCBB - page 20

    W ARNING: CHILDREN AND ADULTS SHOU LD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA TURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITI ON. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN IN THE SAME ROOM AS GAS LOGS. W ARNING: CLOTHING OR OTHER FLA MMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THESE GAS LOGS. WIRING DIAGRAM (MA Z ...

  • New Buck Corporation ZCBB - page 21

    REPLACEMENT PARTS 1. PULL SCREEN (2) PER UNIT 2. SCREEN RODS (2) PER UNIT 3. REAR REFRACTORY AND SIDE REFRACTORY 2 PIECES PER UNIT 6. CANOPY 7. DOOR KIT (PART # MAZCBBDOORS) PARTS MAY BE OBTAINED THROUGH YOUR LO CAL NBC DEALER. IN ABSENCE OF A DEALER, PLEASE CONTACT NEW BUCK CORPORATION AT P.O. BOX 69, 8000 HWY 226 SOUTH, SPRUCE PINE, NC 28777. OPT ...

  • New Buck Corporation ZCBB - page 22

    NEW BUCK CORPORA TION We reserve the right to amend th ese specifications at any tim e without notice. The only warranty applicable is our standard wr itten warranty. We offer no other warranty, expressed or implied. LIMITED W ARRANTY VENTLESS FIREBOX ENCLOSURE New Buck warrants this product to be free from defects in materials and com ponents for ...

Manufacturer New Buck Corporation Category Gas Heater

Documents that we receive from a manufacturer of a New Buck Corporation ZCBB can be divided into several groups. They are, among others:
- New Buck Corporation technical drawings
- ZCBB manuals
- New Buck Corporation product data sheets
- information booklets
- or energy labels New Buck Corporation ZCBB
All of them are important, but the most important information from the point of view of use of the device are in the user manual New Buck Corporation ZCBB.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals New Buck Corporation ZCBB, service manual, brief instructions and user manuals New Buck Corporation ZCBB. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product New Buck Corporation ZCBB.

A complete manual for the device New Buck Corporation ZCBB, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use New Buck Corporation ZCBB by users. Manuals are usually written by a technical writer, but in a language understandable to all users of New Buck Corporation ZCBB.

A complete New Buck Corporation manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual New Buck Corporation ZCBB - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the New Buck Corporation ZCBB, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the New Buck Corporation ZCBB, that we can find in the current document
3. Tips how to use the basic functions of the device New Buck Corporation ZCBB - which should help us in our first steps of using New Buck Corporation ZCBB
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with New Buck Corporation ZCBB
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of New Buck Corporation ZCBB in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning New Buck Corporation ZCBB?

Use the form below

If you did not solve your problem by using a manual New Buck Corporation ZCBB, ask a question using the form below. If a user had a similar problem with New Buck Corporation ZCBB it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)