    0956 Encore Co v er 2/01 Homeowner ’ s Installation and Operating Manual Do Not Discard This Manual: Retain for Future Use 30003842 2/08 Rev . 1 SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAIN- T AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. F AILURE T ...

  • Vermont Casting 2550CE - page 2

    2 Encore W oodbur ning Stove 30003842 Congratulations on your choice of a V ermont Castings Encore. With this purchase you have made a commitment to make the hearth a place of warmth, beauty , and comfort in your home. At CFM Corporation, we share that joy and appreciation for the hearth. Y ou may be assured that your cast-iron V ermont Castings st ...

  • Vermont Casting 2550CE - page 3

    3 Encore W oodbur ning Stove 30003842 Specifications 51 mm (2") 640 mm (25  ") T op exit flue collar height 685 mm (27”) 660 mm (25  ") 470 mm (18  ") 190 mm (7  ") 685 mm (27") 570 mm (22  ") 390 mm (15  ") 130 mm (5") 75 mm (2  ") 5 ...

  • Vermont Casting 2550CE - page 4

    4 Encore W oodbur ning Stove 30003842 SAFETY NOTICE: IF YOUR ENCORE IS NOT PROP- ERL Y INST ALLED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. CONT ACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC- TIONS AND INST ALLA TION INSPECTION REQUIRE- MENTS IN YOUR AREA. Before you begin an installation, ...

  • Vermont Casting 2550CE - page 5

    5 Encore W oodbur ning Stove 30003842 What Kind of Chimney to Use Y ou must connect the Encore to a code-approved masonry chimney with a flue liner , to a relined masonry chimney that meets local codes, or to a prefabricated metal chimney . (Fig. 3) The chimney and chimney con- nector must be in good condition and kept clean. ST241 chimney type ...

  • Vermont Casting 2550CE - page 6

    6 Encore W oodbur ning Stove 30003842 Flue Pipes with a spigot and socket joint should be fitted with the socket facing upwards, to contain con- densates and moisture within the flue. Joints should be made gas tight using proprietary jointing accessories, or , where appropriate, by packing joint with noncombus- tible rope and fire cement. Double ...

  • Vermont Casting 2550CE - page 7

    7 Encore W oodbur ning Stove 30003842 ST492 Defiant freestanding installation 1 1/00 Chimney Elbow Slip Pipe Standard Connector Oval to Round Adapter Flue Collar Thimble Flue Liner Flue ST492 Fig. 5 Chimney connection in a freestanding masonry instal- lation. Securing the Single-wall Connector to a Masonry Chimney Both freestanding masonry chimneys ...

  • Vermont Casting 2550CE - page 8

    8 Encore W oodbur ning Stove 30003842 • The fireplace damper must be sealed to prevent room air from escaping up the flue. However , it must be possible to re-open the damper to inspect or clean the chimney . * Check These Clear- ances ST244 Plymouth fplc over mantel 12/99 * * Chimney Connector Shields Mantel Seal this off ST244 Fig. 7 In this ...

  • Vermont Casting 2550CE - page 9

    9 Encore W oodbur ning Stove 30003842 Floor Protection for Fireplace Installations Do not assume that your fireplace hearth is completely noncombustible. Many fireplace hearths do not meet the “completely noncombustible” requirement because the brick or concrete in front of the fireplace opening is supported by heavy wood framing. (Fig. 1 1) ...

  • Vermont Casting 2550CE - page 10

    10 Encore W oodbur ning Stove 30003842 ance requirements must be strictly observed. In addition, furnishings and other combustible materials must be kept away from the stove as well. In general, a distance of 1219 mm (48”) must be maintained between the stove and moveable combustible items such as dry- ing clothes, furniture, newspapers, firewoo ...

  • Vermont Casting 2550CE - page 11

    1 1 Encore W oodbur ning Stove 30003842    D at least 3 x D Elevation Without Shield Elevation With Shield at least 3 x D at least 1.5 x D at least 1.5 x D Plan Without Shield Plan With Shield Air space of at least 12 mm between noncombustible shield and combusti ...

  • Vermont Casting 2550CE - page 12

    12 Encore W oodbur ning Stove 30003842 Set Up Y our Stove Cast iron stoves are heavy , and it will take two to four people to move your Encore into position. Wipe the protective coating of oil from the griddle with a clean dry rag or a paper towel. Install the handle on the griddle. First, place the griddle upside down at the edge of a flat surfac ...

  • Vermont Casting 2550CE - page 13

    13 Encore W oodbur ning Stove 30003842 ST540 Assembly handle 1 1/00 ST540 Fig. 18 Assemble the front door handle. Operation The Encore Controls T wo controls regulate the performance of the Encore: a primary air control supplies oxygen for the fire, and a damper directs air flow within the stove to activate and deactivate the catalytic combustor ...

  • Vermont Casting 2550CE - page 14

    14 Encore W oodbur ning Stove 30003842 The damper is closed when the handle points forward . Smoke from the fire is directed through the catalytic combustion system where it can be further burned for greater efficiency , before passing up the chimney . When closing the damper , be sure to pull firmly enough to snap it into the locked position. S ...

  • Vermont Casting 2550CE - page 15

    15 Encore W oodbur ning Stove 30003842 ST523 Intrepid temp readings 1 1/00 ST523 Fig. 24 T ake temperature readings with the thermometer located in the middle of the griddle. Store wood under cover to keep it dry . The longer it is stored, the better heating and fireviewing performance you will enjoy . Even for short-term storage, however , keep w ...

  • Vermont Casting 2550CE - page 16

    16 Encore W oodbur ning Stove 30003842 High-Efficiency Wood Burning with Catalytic Combustion An Encore leaves the factory with the combustor in- stalled. In the United States, it is against the law to operate this wood heater in a manner inconsistent with operating instructions in this manual, or if the catalytic combustor is deactivated or remov ...

  • Vermont Casting 2550CE - page 17

    17 Encore W oodbur ning Stove 30003842 Never use gasoline-type lantern fuel, kerosene, char- coal lighter fluid, or similar liquids to start or “freshen up” a fire. Keep all such liquids well away from the Encore while it is in use. 3. Light the newspaper and close the door . Gradually build up the fire by adding a few 76-127mm (3-5”) di - ...

  • Vermont Casting 2550CE - page 18

    18 Encore W oodbur ning Stove 30003842 fresh fuel (smaller pieces first), close the door and damper , and reset the primary air thermostat for the desired heat output. CAUTION: The Encore will be hot while in opera- tion. Keep children, clothing and furniture away . Contact may cause skin burns. • Remove the ash pan, making sure to keep it level ...

  • Vermont Casting 2550CE - page 19

    19 Encore W oodbur ning Stove 30003842 Draft Management A stove is part of a system, which includes the chimney , the operator , the fuel, and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the system works well. Wood stove or insert operation depends on natural (unfor ...

  • Vermont Casting 2550CE - page 20

    20 Encore W oodbur ning Stove 30003842 Creosote Creosote is a by-product of slow wood-burning. It’s an organic tar that can condense in the flue if it’s dense in the smoke, and slow-moving, and cools off to less than 143° C (290° F). Condensed creosote is volatile, and can generate chimney fires if it gets hot enough. All the features that ...

  • Vermont Casting 2550CE - page 21

    21 Encore W oodbur ning Stove 30003842 Maintenance Below you will find important information on general care, inspection and maintenance of your V ermont Castings stove. Should it become necessary , use only replacement parts recommended by your authorized dealer . Keep Y our Stove Looking New and Working Its Best Let the fire in the stove go out ...

  • Vermont Casting 2550CE - page 22

    22 Encore W oodbur ning Stove 30003842 3. Replace the doors on the stove. Remove the griddle so you can reach in through the opening to posi- tion the manifold. Move the door manifold as high as possible without actually touching the upper air manifold, and as far toward the center of the stove as possible without hitting the door manifold on the o ...

  • Vermont Casting 2550CE - page 23

    23 Encore W oodbur ning Stove 30003842 • Then, open the stove damper and once again check the smoke leaving the chimney . Significantly more smoke should be seen when the stove damper is open and exhaust does not pass through the combus- tor . Be careful not to confuse smoke with steam from wet wood, however . Steam dissipates in the air quickly ...

  • Vermont Casting 2550CE - page 24

    24 Encore W oodbur ning Stove 30003842 10. Clean the chimney and chimney connector . Operate the stove in your typical manner for two weeks, inspecting the chimney and the chimney connector frequently during this period. If creosote is not building up as fast, it is likely the performance change was caused by fly ash deposits on the catalytic elem ...

  • Vermont Casting 2550CE - page 25

    25 Encore W oodbur ning Stove 30003842 If you need to change a gasket, first obtain an appropri- ate replacement from your V ermont Castings’ Autho- rized Dealer . W ait until the fire is out and the stove has cooled. Be sure to follow the standard safety procedure for working with dusty materials: Wear safety goggles and a dust mask. The proce ...

  • Vermont Casting 2550CE - page 26

    26 Encore W oodbur ning Stove 30003842 If you do experience a chimney fire, act promptly to: • Close the damper and thermostat lever . • Get everyone out of the house. • Call the Fire Department. Y ou should inspect the system every two weeks during the heating season as part of a regular maintenance schedule. T o inspect the chimney , let t ...

  • Vermont Casting 2550CE - page 27

    27 Encore W oodbur ning Stove 30003842 Appendix: Catalytic Combustor In any chemical reaction, including the combustion process, there are certain conditions which must be met before the reaction can take place. For example, a reaction may require a certain temperature, or a certain concentration of the reactants (the combustion gases and oxygen), ...

  • Vermont Casting 2550CE - page 28

    28 Encore W oodbur ning Stove 30003842 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 1 2 3 6 5 10 9 7 4 1 1 1 14 15 16 17 18 21 23 21 25 27 28 30 31 33 34 35 36 37 38 39 40 41 42 43 44 45 61 62 70 71 50 51 52 53 54 55 56a 57 58 59 60 ...

  • Vermont Casting 2550CE - page 29

    29 Encore W oodbur ning Stove 30003842 1. Included in #5008649 upper fireback assembly . 2. Not interchangeable, due to a heat-reflective coating on the room side of the panels. 3. Included in #0004345 ceramic handle assembly . Encore W oodburning Stove Model 2550CE (continued) Item Description Part Number Item Description Part Number 15. Right G ...

  • Vermont Casting 2550CE - page 30

    30 Encore W oodbur ning Stove 30003842 Shell Enamel Parts - Encore Enamel Color T op Left Side Right Side Front Ashlip Single Leg Classic 1308618 1308623 1308619 1308635 1307406 1307427 Biscuit 30003007 30003006 30003005 30003004 30003002 30003003 Bordeaux 2328618 2328623 2328619 2328635 2377406 2327427 Chestnut Brown 30003019 30003018 30003017 300 ...

  • Vermont Casting 2550CE - page 31

    31 Encore W oodbur ning Stove 30003842 W arranty Limited 3 Y ear W arranty CFM Corporation warrants that this woodburning stove will be free of defects in material and workmanship for a period of three years from the date you receive it, except that the catalyst, thermostat assembly , handles, glass door panels, cement, and gasketing shall be warra ...

  • Vermont Casting 2550CE - page 32

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation ...

Manufacturer Vermont Casting Category Stove

Documents that we receive from a manufacturer of a Vermont Casting 2550CE can be divided into several groups. They are, among others:
- Vermont Casting technical drawings
- 2550CE manuals
- Vermont Casting product data sheets
- information booklets
- or energy labels Vermont Casting 2550CE
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vermont Casting 2550CE.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vermont Casting 2550CE, service manual, brief instructions and user manuals Vermont Casting 2550CE. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vermont Casting 2550CE.

A complete manual for the device Vermont Casting 2550CE, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vermont Casting 2550CE by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vermont Casting 2550CE.

A complete Vermont Casting manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vermont Casting 2550CE - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vermont Casting 2550CE, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vermont Casting 2550CE, that we can find in the current document
3. Tips how to use the basic functions of the device Vermont Casting 2550CE - which should help us in our first steps of using Vermont Casting 2550CE
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vermont Casting 2550CE
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vermont Casting 2550CE in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vermont Casting 2550CE?

Use the form below

If you did not solve your problem by using a manual Vermont Casting 2550CE, ask a question using the form below. If a user had a similar problem with Vermont Casting 2550CE it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)