  • Sterling SSP 5 - page 1

    Op er ating In struc tions Con veyor Hop per SSP 5 5 2 6 - 3 M S Ster ling Ma te rial Pro cess ing ...

  • Sterling SSP 5 - page 2

    Tech ni cal ser vice: Ser vice de part ment Tele phone: (800) 423-3183 Edi tion: 04/01 5 2 6 - 3 M S SSP 5 2 Ster ling Ma te rial Pro cess ing 5200 West Clinton Ave. Mil wau kee, WI 53223 Tele phone: (414) 354-0970 Fax: (414) 354-6421 These op er at ing in struc tions are for:* (* Plea se fill in per so nal ly) Se ri al num ber: Built in: Date of d ...

  • Sterling SSP 5 - page 3

    Ster ling Ma te rial Pro cess ing re tains all rights to change the in for ma tion in these op er at ing in struc t ions at any time with out no tice. We as sume no li a bil ity for any er rors or di rect or in di rect dam age re sult ing in con - text with these op er at ing in struc t ions. Copying, trans la tion or pub li ca tion in any form ex ...

  • Sterling SSP 5 - page 4

    Please note that our address and phone information has changed. Please reference this page for updat ed contact information. These manuals are obsolet e and are provided only for their technical information , data and capacities. Portions of t hese manuals detail ing procedures or precautions in the operation, inspection, main tenance and repair of ...

  • Sterling SSP 5 - page 5

    Ta ble o f con tents 1. Safety in struc tions ............................................6 1.1. Warn ings and sym bols ..................................7 1.2. Ex pla na tions and in for ma t ion .............................8 1.3. For your safety ........................................9 1.4. For the safety of the equip ment ..................... ...

  • Sterling SSP 5 - page 6

    6. Tech ni cal data ............................................... 30 7. Spare parts list .............................................. 32 8. Ac ces sories ................................................. 35 o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

  • Sterling SSP 5 - page 7

    1. Safety in struc tions » These safety in struc tions ap ply to all per sons within the range of ac tion of the equip ment. Please in form all per sons within the range of ac tion of the equip - ment of the di rect and in di rect haz ards con nected with the equip ment. These op er at ing in struc tions are to be used by all per sons as - signed ...

  • Sterling SSP 5 - page 8

    1.1. Warn ings and sym bols The fol low ing warn ings and sym bols are used in these op er at ing in struc tions: » This sym bol in di cates dan ger to life! Fa tal or se ri ous in jury is pos si ble if the cor re spond ing in struc tions, reg u la tions or warn - ings are not ob served. L This sym bol in di cates that se ri ous in jury is pos si ...

  • Sterling SSP 5 - page 9

    1.2. Ex pla na tions and in for ma tion Var i ous terms and des ig na tions are used fre quently in these op er at ing in struc - tions to en sure clar ity. There fore please note that the term s used in the text stand for the cor re spond ing ex pla na tions listed be low. · Equip ment “Equip ment” can mean an in di vid ual unit, a ma chine o ...

  • Sterling SSP 5 - page 10

    1.3. For your safety · It is ab so lutely nec es sary that you ob serve the op er at ing in struc tions for the cor - re spond ing con vey ing sys tem. · The de vice is in tended ex clu sively for con vey ing plas tic gran ules and regrind. Any other us age is not per mit ted. · This de vice is not suit able for pro cess ing foods. · Be fore be ...

  • Sterling SSP 5 - page 11

    2. In stal la tion in struc tions » These in stal la tion in struc tions are in tended for per sons with skills in elec tri cal and me chan i cal ar eas due to their train ing, ex - pe ri ence and re ceived in struc t ions. Per son nel us ing these in stal la tion in struc tions must be in - structed in the reg u la tions for the pre ven tion of a ...

  • Sterling SSP 5 - page 12

    In stall the equip ment such that all parts ar e eas ily ac ces si - ble; this fa cil i tates main te nance and re pair work. 2.1. Trans port For trans port, only the ap pro pri ate lift ing gear should be used (e. g. fork lift or work shop crane). » Ob serve the car ry ing ca pac ity of the lift ing gear. Ob serve the safety in struc tions for th ...

  • Sterling SSP 5 - page 13

    2.2. Set-up The ar range ment of the hop per load ers may v ary de pend ing on the type of de - vice to be con veyed on and the ma te rial used. Fas ten ing onto fixed ma chine throats is pro vided by means of strap re tain ers. How ever, ad di tional sup port of the hop per loader is nec es sary if t he de vices are not suf fi ciently ca pa ble of ...

  • Sterling SSP 5 - page 14

    2.3. Com pressed-air sup ply For op er at ing the con trol valves and the clean ing unit, a com pressed-air sup ply is nec es sary. L Depressurize com pressed-air sup ply lines which must be opened. F Com pressed air must be dewater ed, dustfree and oilfree. In stall a main te nance unit if re quired. Ad just pres sure to a m ax. value of 6 bar (87 ...

  • Sterling SSP 5 - page 15

    2.4. Elec tri cal con nec tion » The elec tri cal con nec tion may only be car ried out by trained per - son nel. Other per sons are not per mit ted to carry out t he elec tri cal con - nec tion. The rules of the lo cal elec tric ity board m ust be ob served. Be fore be gin ning the elec tri cal con nec tion, mak e sure that the mains volt age and ...

  • Sterling SSP 5 - page 16

    3. Func tional de scrip t ion » This func tional de scrip tion is in tended for all op er at ing per son - nel of the equip ment. Pre req ui site for this func tional de scrip tion is gen eral knowl edge of con vey ing units. En sure in each case that the op er at ing per son nel are suf fi - ciently in formed. 5 2 6 - 3 M S SSP 5 Func tional de s ...

  • Sterling SSP 5 - page 17

    3.1. Gen eral The con veyor hop per is used for the au to matic con vey ance of freely flow ing plas - tic gran ules, regrind and pow der. The hop per can only func tion in con nec tion with a multi-st a tion vac uum con vey ing sys tem . The con veyor hop per func tions ac cord ing to the prin ci ple of suc tion con vey ance. A high-per for mance ...

  • Sterling SSP 5 - page 18

    3.2. Con trol ler SSP The set ting for the con vey ing time and the line clear time are made v ia the keys (A1: “change-over” key, A2: “ ar row key”) on the fr ont of the con trol sys tem. The val ues which have been set will be dis played on the dis play (B). The val ues which have been set are main tained af ter t he ma chine has been shu ...

  • Sterling SSP 5 - page 19

    4. Putting into op er a tion » This chap ter is in tended for op er at ing per son nel. Pre req ui site for this chap ter is gen eral knowl edge of the op er a - tion of con vey ing units. Also pre req ui site for this chap ter is t hat the func tional de scrip - tion has been read and un der stood. En sure in each case that the op er at ing per s ...

  • Sterling SSP 5 - page 20

    4.1. Set ting the con trol l er SSP & It is only pos si ble to set the pulse du ra tion / tim e in ter val when the unit is not con vey ing any ma te rial. Set ting the pulse du ra tion Press the “ar row key” . & The pulse du ra tion (= du ra tion of a clean ing pulse) which was last se lected ap pears in the dis play. 0.5, 1.0 or 1.5 s ...

  • Sterling SSP 5 - page 21

    4.2. Alarm Mes sages dis played on the con trol ler SSP If a dis tur bance oc curs in the unit , an alarm mes sage will be is sued. & An “E” ap pears in the dis play and an er ror num ber. “E2" If the con trol sys tem be comes too hot dur ing op er a tion >70°C (158°F) the “E2" alarm mes sage is dis played and the unit is ...

  • Sterling SSP 5 - page 22

    5. Main te nance » This chap ter is in tended for per sons with skills in elec tri cal and me chan i cal ar eas due to their train ing, ex pe ri ence and re ceived in struc tions. Per son nel us ing the in struc tions in this chap ter m ust be in - structed of the reg u la tions for the pre ven tion of ac ci dents, t he op er at ing con di tions a ...

  • Sterling SSP 5 - page 23

    L Dis con nect the equip ment from mains sup ply be fore start ing main te nance pro ce dures to en sure that it can not be switched on un in ten tion ally. Depressurize all com pressed air pip ing of the equip ment be - fore start ing main te nance work. F Please ob serve the main te nance in ter vals. Be fore start ing main te nance work, clean t ...

  • Sterling SSP 5 - page 24

    5.1. Main te nance in ter val s Daily: check warn ing signs on equip ment for good leg i bil ity and com plete ness. Weekly: check the main te nance unit check the op er at ing pres sure in the fac tory ductwork sys tem (max. 6 bar sys tem overpressure) Monthly: check the sealings on the fil ter car tridges (ac cord ing to the ac cu mu la tion of d ...

  • Sterling SSP 5 - page 25

    5.2. Re placing the nonreturn valve seal ing ring » Stop the con vey ing pro ce dure. Switch off the hop per by means of the on/off switch on the con - nec tion hous ing. Switch off the con vey ing con trol by m eans of the main switch. Dis con nect the unit from mains sup ply. Depressurize all sys tem sec tions of t he equip ment. Open the ten si ...

  • Sterling SSP 5 - page 26

    5.3. Re placing the out let f lap seal ing ring » Stop the con vey ing pro ce dure. Switch off the hop per by means of the on/off switch on the con - nec tion hous ing. Switch off the con vey ing con trol by m eans of the main switch. Dis con nect the unit from mains sup ply. Depressurize all sys tem sec tions of t he equip ment. Re move the ten s ...

  • Sterling SSP 5 - page 27

    5.3.1. Ad just the flap sw itch Re move the con nect ing plug “flap switch” from the con nec tion hous ing of the hop per. Con nect an ohm me ter t o PINS 2 and 3 of the con nect ing plug “flap switch”. Re lease the nuts (A) of the flap switch (B) un til the sup port can be dis placed. Open the out let flap (C) so far t hat the front tip of ...

  • Sterling SSP 5 - page 28

    5.4. Cleaning the hop per loader » Stop the con vey ing pro ce dure. Switch off the hop per by means of the on/off switch on the con - nec tion hous ing. Switch off the con vey ing con trol by m eans of the main switch. Dis con nect the unit from mains sup ply. Depressurize all sys tem sec tions of t he equip ment. Open the ten sion ring (A). Re m ...

  • Sterling SSP 5 - page 29

    5.5. Cleaning/re plac ing the f il ter car tridges of the clean ing unit » Stop the con vey ing pro ce dure. Switch off the hop per by means of the on/off switch on the con - nec tion hous ing. Switch off the con vey ing con trol by m eans of the main switch. Dis con nect the unit from mains sup ply. Depressurize all sys tem sec tions of t he equi ...

  • Sterling SSP 5 - page 30

    Re moval Open the ten sion ring (A). Re move the hop per loader lid. Re move the clean ing unit. Re lease clamp ing de vices of the fil ter car - tridges. Re move the fil ter car tridges from the in ter - me di ate plat form . Clean the fil ter car tridges f rom the in side out by means of com pressed air or re - place the fil ter car tridges by ne ...

  • Sterling SSP 5 - page 31

    6. Tech ni cal data Ba sic Ver sion • Con veying hop per made of stain less steel • In te grated high per for mance fil ter • Au to matic fil ter clean ing • In te grated con trol ler for clean ing Per for mance • Hop per loader ca pac ity SSP 5: approx. 5 l (0.28 cf.) with ex ten sion mod ule: max. 15 l (0.53 cf.) • Typ i cal con vey i ...

  • Sterling SSP 5 - page 32

    Di men sion Sheet 5 2 6 - 3 M S SSP 5 Tech ni cal data 31 Di men sions and data wit hout ob li ga ti on. Di men sions in mm (in.). Spec i fi ca tions may be sub ject to al te ra tions. ...

  • Sterling SSP 5 - page 33

    7. Spare parts list » This parts list is only for the use of tr ained per son nel only. All other per sons are not per mit ted to re pair or to c hange the equip ment. 5 2 6 - 3 M S SSP 5 Spare parts list 32 ...

  • Sterling SSP 5 - page 34

    5 2 6 - 3 M S SSP 5 Spare parts list 33 ...

  • Sterling SSP 5 - page 35

    Pos. Or der no. Des ig na tion 1 26487 Pneu matic valve 2 85460 Vent valve 85462 Com pressed-air con tainer 97556 So le noid valve 3 86851 Ten sion ring 4 98754 Sealing (1 m) 5 83081 Con tro l ler SSP ( 24 V) 6 83379 Fil ter car tridge, s hort ver sion (4x) 7 85533 Ten sion ring 8 28420 Sealing 9 85610 Sealing ring 10 35796 Fil ter sup port 26299 F ...

  • Sterling SSP 5 - page 36

    8. Ac ces sories o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 2 6 - 3 M S SSP 5 Ac ces sories 35 ...

Manufacturer Sterling Category Marine Battery

Documents that we receive from a manufacturer of a Sterling SSP 5 can be divided into several groups. They are, among others:
- Sterling technical drawings
- SSP 5 manuals
- Sterling product data sheets
- information booklets
- or energy labels Sterling SSP 5
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sterling SSP 5.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sterling SSP 5, service manual, brief instructions and user manuals Sterling SSP 5. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sterling SSP 5.

Similar manuals

A complete manual for the device Sterling SSP 5, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sterling SSP 5 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sterling SSP 5.

A complete Sterling manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sterling SSP 5 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sterling SSP 5, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sterling SSP 5, that we can find in the current document
3. Tips how to use the basic functions of the device Sterling SSP 5 - which should help us in our first steps of using Sterling SSP 5
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sterling SSP 5
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sterling SSP 5 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sterling SSP 5?

Use the form below

If you did not solve your problem by using a manual Sterling SSP 5, ask a question using the form below. If a user had a similar problem with Sterling SSP 5 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)