  • Omega HH501AK - page 2

    OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com Servicing Nor th America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com omeg ...

  • Omega HH501AK - page 3

    1 The symbol on the instrument indicates that the operator must refer to an explanation in this manual. WARNING To avoid electrical shock, do not use this instrument when working voltages at the measurement surface over 24V AC or DC. WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. CAUTION Repeated sharp fle ...

  • Omega HH501AK - page 4

    SPECIFICATIONS ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable. Measurement Range: -200°C to 1372°C, -328°F to 1999°F Resolution: 0.1°C , 0.1°F (-59.9°C to 199.9°C ,-59.9°F to 199.9°F) 1°C , 1°F on other range Accuracy: Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F) ...

  • Omega HH501AK - page 5

    3 ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Overload: "-OL" is display. Battery: Standard 9V battery. Battery Life: 100 hours typical. Auto pow ...

  • Omega HH501AK - page 6

    OPERATING INSTRUCTIONS Power Switch The key turns the thermometer on or off. In the MIN MAX record mode can not power off, must leave MIN MAX record mode then power off. °C °F Selecting the Temperature Scale Readings is displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the tempera ...

  • Omega HH501AK - page 7

    MIN MAX record Mode Press MIN MAX key to enter the MIN MAX Recording mode, (displays the Maximum reading, Minimum reading, "MAX-MIN" reading and Average reading stored in record mode). In the this mode the automatic power-off feature is disabled and key and all function key are disabled.The beeper emits a tone when a new minimum or maximu ...

  • Omega HH501AK - page 8

    REL Relative mode (only Main display) Pressing REL key to enter the Relative mode, zero the display, and store the displayed Reading as a reference value and annunciator REL is displayed. Press REL key again to exit the relative mode. The relative value can also be entered by the user. (See "SET mode" later in this manual.) When the desir ...

  • Omega HH501AK - page 9

    7 12 (Press ENTER key can escape Lo Limit value set mode), _ = = =.= is displayed (the ".=" is displayed when you set up the fourth number), Lo Limit value is entered via overlay numbers, when you want to get negative values push (- 0) key for end of numbers, then press overlay ENTER key, stored the Lo Limit value and exit set mode. 3. In ...

  • Omega HH501AK - page 10

    8 OPERATOR MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. The " " appears on the LCD display when replacement is needed. To replace the battery, remove the two sc ...

  • Omega HH501AK - page 11

    1 HH501(A,B) K / HH501(A,B) J / HH501(A, B)T / HH501( A,B)E HH508BR/HH508/HH509/ HH509R CA LIBRA TION PROCEDURE Note: The following calibration procedure s hould perform only by qualified technicians who have access to the items as fol lowing. Equipment: The class of calibrator ha d better 10 times g reater than the mea sured meter. 1. Set the jump ...

  • Omega HH501AK - page 12

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC . warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month gr ace period to the nor mal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customer ...

  • Omega HH501AK - page 13

    M-2815/0799 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE þ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies þ Wire: Thermocouple, RTD & Thermistor þ Calibrators & Ice Point References þ Recorders, Controllers & Process Monitors þ Infrared Pyromet ...

Manufacturer Omega Category Thermometer

Documents that we receive from a manufacturer of a Omega HH501AK can be divided into several groups. They are, among others:
- Omega technical drawings
- HH501AK manuals
- Omega product data sheets
- information booklets
- or energy labels Omega HH501AK
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega HH501AK.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega HH501AK, service manual, brief instructions and user manuals Omega HH501AK. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega HH501AK.

Similar manuals

A complete manual for the device Omega HH501AK, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega HH501AK by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega HH501AK.

A complete Omega manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega HH501AK - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega HH501AK, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega HH501AK, that we can find in the current document
3. Tips how to use the basic functions of the device Omega HH501AK - which should help us in our first steps of using Omega HH501AK
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega HH501AK
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega HH501AK in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega HH501AK?

Use the form below

If you did not solve your problem by using a manual Omega HH501AK, ask a question using the form below. If a user had a similar problem with Omega HH501AK it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)