  • Graco 308652Y - page 1

    Husky t 205 Air–Operated Diaphragm Pumps 100 psi (0.7 MPa, 7 bar) Maximum Incoming Air Pressure 100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure Part No. D120 XX Polypropylene Pump with Air–Operated Motor Part No. D1 10 XX and DM10 XX Acetal Pump with Air–Operated Motor Part No. D150 XX and DM50 XX PVDF Pump with Air–Operated Motor P ...

  • Graco 308652Y - page 2

    2 308652 Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco 308652Y - page 3

    3 308652 HAZARDOUS FLUIDS Improper handling of hazardous fluids or inhaling toxic vapors can cause extremely serious injury or death from splashing in the eyes, ingestion, or bodily contamination. Observe all the following precautions when you handle hazardous or potentially hazardous fluids. D Know what fluid you are pumping and its specific hazar ...

  • Graco 308652Y - page 4

    4 308652 Installation Tightening Threaded Fasteners Before First Use Before using the pump for the first time, check and retorque all external fasteners. See T orque Se- quence , page 18. After the first day of operation, retorque the fasteners. Although pump use varies, a general guideline is to retorque fasteners every two months. Use a compatibl ...

  • Graco 308652Y - page 5

    5 308652 Installation Air Exhaust V entilation W ARNING TOXIC FLUID HAZARD Read the USING HAZARDOUS FLUIDS and FIRE AND EXPLOSION HAZARD sections on page 3 before you operate this pump. Be sure the system is properly ventilated for your type of installation. Y ou must vent the exhaust to a safe place, away from people, animals or food handling area ...

  • Graco 308652Y - page 6

    6 308652 Installation Air Lines W ARNING Bleed-T ype Master Air V alve and Fluid Drain V alve A bleed-type master air valve and a fluid drain valve are required on your system. The bleed-type master air valve relieves air trapped between itself and the pump. T rapped air can cause the pump to cycle unexpectedly , which could result in serious bodil ...

  • Graco 308652Y - page 7

    7 308652 Installation Fig. 4 KEY A Husky 205 pump B Bleed-type master air valve (required for pump) C Air line(s) E Master air valve (for accessories) F Air line filter G Muf fler H Pump air regulator J Fluid drain valve (required on fluid outlet side of pump) L Fluid suction line N Fluid supply hose T Bung adapter U 4-way solenoid Y Ground wire (r ...

  • Graco 308652Y - page 8

    8 308652 Operation Pressure Relief Procedure W ARNING T o reduce the risk of serious injury , including splashing fluid in the eyes or on the skin, follow this procedure whenever you are instructed to relieve pressure, when you shut off the pump, and before you check, adjust, clean, move, or repair any system equipment. 1. Shut off air and reserve ...

  • Graco 308652Y - page 9

    9 308652 Maintenance Lubrication The air valve is lubricated at the factory and designed to operate without additional lubrication. If added lubrication is desired, every 500 hours of operation (or monthly), remove the hose from the pump air inlet and add two drops of machine oil to the air inlet. CAUTION Do not over-lubricate the pump. Excess oil ...

  • Graco 308652Y - page 10

    10 308652 T roubleshooting Relieve the pressure before you check or service the equipment. Check all possible problems and causes before you disassemble the pump. W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Internal Air V alve-Operated and Rem ...

  • Graco 308652Y - page 11

    11 308652 T roubleshooting Internal Air V alve-Operated Pumps Only PROBLEM CAUSE SOLUTION The pump will not cycle, or it cycles once and stops. The air valve is stuck or dirty . Not enough air pressure supplied. Disassemble and clean or repair the air valve. See page 12. Use filtered air . Increase air pressure supply . Do not exceed maximum input ...

  • Graco 308652Y - page 12

    12 308652 Service Service Kits Service Kits may be ordered separately . T o repair the air valve, order Part No. 238853. Parts included in the Air V alve Service Kit are marked with an asterisk in the Parts Drawing on page 17, for example (3*). For fluid section repair section parts, see the Service Kit Matrix on page 15. Parts included in the Flui ...

  • Graco 308652Y - page 13

    Fig. 6 50 30 57 8 06180D 58 58 51 1 10 11 9 12 13 13 308652 Service Replacing Diaphragms Replace the diaphragms as follows. See Fig. 6 and Fig 7. 1. Relieve the pressure , and disconnect the air line from the pump. W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Proce ...

  • Graco 308652Y - page 14

    14 308652 Service Replacing Check V alves Replace each pair of check valves as follows. See Fig. 7. 1. Relieve the pressure , and disconnect the air line from the pump. W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 2. Remove the eight screws (58 ...

  • Graco 308652Y - page 15

    15 308652 Parts Matrix Husky 205 Polypropylene, Acetal*, and PVDF Pumps The Model Number of your pump is marked on the pump’s serial plate. T o determine the Model Number of your pump from the following matrix, select the six digits that describe your pump, working from left to right. The first digit is always D , designating Husky diaphragm pump ...

  • Graco 308652Y - page 16

    16 308652 Parts Air Motor Section (matrix column 2) Digit Ref. No. Part N o. Description Qty . 1 1 240898 HOUSING, center , assembly (includes 12, 13, and 57) 1 2 191 157 CARRIAGE, valve 1 3 1 13869 SEAL, u-cup 2 4 194533 V AL VE BLOCK (for pump with air -operated air motor) 1 5 191 160 GASKET , molded 1 6 1 15056 O-RING, packing 2 8 191021 PIN, ac ...

  • Graco 308652Y - page 17

    Used on acetal models only . 3 T orque to 40–45 in-lb (4.5–5.0 N S m). See T orque Sequence on page 18 4 Not assembled. These plugs are supplied to plug the two ports in the manifold that are not used. 9 5 T orque to 20 in-lb (2.2 N S m). 4 21 { 20 1 * H} 2 1 8 9 { 50 11 12 { 7 10 50 51 51 52 54 55 30 30 57 57 { 58 1 15 58 53 9 * H} 3 * } 6 * } ...

  • Graco 308652Y - page 18

    18 308652 T orque Sequence For proper installation, always follow torque sequence whenever you are instructed to torque screws. 1. V alve Cover T orque bolts to 40–45 in–lb (4.5–5.0 N S m) 2. Left/Right Fluid Cover T orque bolts to 42–47 in–lb (4.7–5.3 N S m) 3. Manifold to Center Section T orque bolts to 42–47 in–lb (4.7–5.3 N S ...

  • Graco 308652Y - page 19

    19 308652 T echnical Data Maximum fluid working pressure 100 psi . . . . . . . . . . . . . (0.7 MPa, 7 bar) Maximum/minimum air pressure 100 psi/20psi . . . . . . (0.7 MPa, 7 bar)/(0.14 MPa, 1.4 bar) Maximum fluid flow 5.0 gpm (18.9 lpm) . . . . . . . . . . . . . Maximum pump speed 320(dry) cycles per minute . . . . 250(wet) cycles per minute V olu ...

  • Graco 308652Y - page 20

    20 308652 Dimensions and Mounting Hole Layout 6.0 in. 152.4 mm 3.7 in. 94 mm Four 0.281 in. 7.137 mm diameter holes 6.8 in. 173 mm Four 0.175 in. x .85 in. deep 4.445 mm x 21.59 mm deep diameter holes 2.5 in. 63.5 mm 3.0 in. 76.2 mm Four 0.230 in. (5.8 mm) diameter holes ti10913a ti10914a 5.4 in. 137 mm ...

  • Graco 308652Y - page 21

    21 308652 Performance Charts Husky 205 Flui d Outlet Pressure FLUID FLOW --gpm (lpm) T est Conditions: Pump tested in water with inlet submerged. T o find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (gpm/lpm) and operating air pressure (psi/MPa/bar): 1. Locate fluid flow rate along bottom of chart. 2. Follow vertical line up to int ...

  • Graco 308652Y - page 22

    22 308652 Performance Charts FLUID FLOW --gpm (lpm) T est Conditions: Pump tested in water with inlet submerged. AIR CONSUMPTION––scfm (cubic meters/min) T o find Pump Air Consumption (scfm or m # /min) at a specific fluid flow (gpm/lpm) and air pressure (psi/MPa/bar): 1. Locate fluid flow rate along bottom of chart. 2. Read ve rtical line up t ...

  • Graco 308652Y - page 23

    23 308652 Notes ...

  • Graco 308652Y - page 24

    24 308652 Graco W arranties Graco Standard Husky Pump W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a per ...

Manufacturer Graco Category Water Pump

Documents that we receive from a manufacturer of a Graco 308652Y can be divided into several groups. They are, among others:
- Graco technical drawings
- 308652Y manuals
- Graco product data sheets
- information booklets
- or energy labels Graco 308652Y
All of them are important, but the most important information from the point of view of use of the device are in the user manual Graco 308652Y.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Graco 308652Y, service manual, brief instructions and user manuals Graco 308652Y. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Graco 308652Y.

Similar manuals

A complete manual for the device Graco 308652Y, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Graco 308652Y by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Graco 308652Y.

A complete Graco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Graco 308652Y - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Graco 308652Y, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Graco 308652Y, that we can find in the current document
3. Tips how to use the basic functions of the device Graco 308652Y - which should help us in our first steps of using Graco 308652Y
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Graco 308652Y
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Graco 308652Y in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Graco 308652Y?

Use the form below

If you did not solve your problem by using a manual Graco 308652Y, ask a question using the form below. If a user had a similar problem with Graco 308652Y it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)