Manual York GF8

16 pages 0.56 mb
Download

Go to site of 16

Summary
  • York GF8 - page 1

    035-19992-001 Rev. A (0404) USER’S INFORMA TION, MAINTENANCE AND SER VICE MANU AL MODELS: G8C/ GF8 (Single Stage Multi-P osition) EFFICIENCY RA TING CERTIFIED This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO 9001. The manufacturer recomm ends that the user read all se c- tions o ...

  • York GF8 - page 2

    035-19992-001 Rev. A (0404) 2 Unitary Products Group 7. NEVER … S tore flammable materials of any kind near you r fur- nace. Gasoline, solvents, and ot her volatile liquids should be stored only in approved containers outside your home. These materials vaporiz e easily and are extremely dangerous. 8. NEVER … S tore cleaning materials near your ...

  • York GF8 - page 3

    035-19992-001 Rev. A (0404) Unitary Products Group 3 INSTRUCTIONS FOR EXAMINING THE FUR NACE INST ALLA TION It is the owner ’s responsibility to ensure that an annual inspection of the entire heating portion of the unit is made by a qualified service agency . Examine the furnace as outlined below in steps “1 - 6” before each heating season. U ...

  • York GF8 - page 4

    035-19992-001 Rev. A (0404) 4 Unitary Products Group HOW Y OUR GAS FURNACE WORKS Y our furn ace is a very easy applianc e to take for gra nted. Season after season, it sits there in your home, keeping you warm and comfortable. For this reason, you may never have given much thought to the way your furnace operates. In order to get the safest and mos ...

  • York GF8 - page 5

    035-19992-001 Rev. A (0404) Unitary Products Group 5 If, during the inspection of your fur nace, you find any of the following conditions: • Excessive amounts of dust and lint on components. • Damaged or deteriorated components or surfaces. • Leaks or blockage in the vent pipe passages. • W ater on any surface inside or outside of the furna ...

  • York GF8 - page 6

    035-19992-001 Rev. A (0404) 6 Unitary Products Group T o remove the filter you must do the follow ing: 1. Before proceeding, be sure the area is well ventilated. Follow instruction “T o turn off the appliance”. Check all metal parts and surfaces to be sure they have cooled to room temperature before you begin. 2. Remove the door by removing the ...

  • York GF8 - page 7

    035-19992-001 Rev. A (0404) Unitary Products Group 7 4. Disconnect wires from flame sensor , rollout swit ch and HSI ignitor . Remove ignitor carefully , as it is easily broken. 5. Remove the screws that hold the burner box assembly to the vest panel and remove the assembly . 6. Remove burners from the burner assembly . 7. Rinsing in hot water may ...

  • York GF8 - page 8

    035-19992-001 Rev. A (0404) 8 Unitary Products Group If the flame is not detected within 2 seconds of the gas valve opening, the gas valve is shut off and a retry op eration begins. If the flame is lost for 2 seconds during the 10-second stabilization period , the gas valve is shut off and a retry ope ration begins. During a retry operation, the ve ...

  • York GF8 - page 9

    035-19992-001 Rev. A (0404) Unitary Products Group 9 6 FLASH : This indicates that after the unit was operating, the pressure switch opened 4 times durin g the call for heat. If the ma in blower is in a "Delay on" mode it will complete it, and any sub sequent delay off period. The induced draft motor cont inues to operate until the pressu ...

  • York GF8 - page 10

    035-19992-001 Rev. A (0404) 10 Unitary Products Group SECTION III: REPLACEMENT P ARTS LIST 26 26 6 21 21 13 13 15 15 15 19 20 17 18 21 8 4 4 1 2 7 11 11 26 12 7 29 5 10 9 24 31 27 O F F OFF O N ON 28 22 23 32 33 ITEM DESCRIPTION 1 Casing, T op Cap 2 Heat Exchanger Assembly 3* Gasket, V ent Blower 4B l o w e r , V e n t 5 T ube, Pressur e 6 Switch, ...

  • York GF8 - page 11

    035-19992-001 Rev. A (0404) Unitary Products Group 11 FIELD INST ALLED A CCESSORIES - NON-ELECTRICAL Field Installed Accessories-Non-Electrical Part Number Description Used With 1FB0318 Combustible Floor Sub-Base 50, 7512 1FB0319 7516,10016 1FB0320 10020,125 1BR0312 Bottom Filter Rack 50,7512 1BR0316 7516,10016 1BR0320 10020,125,150 1NP0366 Convers ...

  • York GF8 - page 12

    035-19992-001 Rev. A (0404) 12 Unitary Products Group SECTION IV: WIRING DIAGRAM FIGURE 15: Wiring Diagram ...

  • York GF8 - page 13

    035-19992-001 Rev. A (0404) Unitary Products Group 13 NOTES ...

  • York GF8 - page 14

    035-19992-001 Rev. A (0404) 14 Unitary Products Group NOTES ...

  • York GF8 - page 15

    035-19992-001 Rev. A (0404) Unitary Products Group 15 NOTES ...

  • York GF8 - page 16

    Subject to change without notice. Printed in U.S.A. 035-19992-001 Rev. A (0404) Copyright © by York International Corp. 2004. All rights reserved. Supersedes: 035-15243-005 Re v. B (0902) Unitary 5005 Norman Product s Y ork OK Group Drive 73069 Limited Warranty UPG warrant s this product to be free from defects in facto ry workmanship and mater ia ...

Manufacturer York Category Furnace

Documents that we receive from a manufacturer of a York GF8 can be divided into several groups. They are, among others:
- York technical drawings
- GF8 manuals
- York product data sheets
- information booklets
- or energy labels York GF8
All of them are important, but the most important information from the point of view of use of the device are in the user manual York GF8.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York GF8, service manual, brief instructions and user manuals York GF8. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York GF8.

Similar manuals

A complete manual for the device York GF8, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York GF8 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York GF8.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York GF8 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York GF8, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York GF8, that we can find in the current document
3. Tips how to use the basic functions of the device York GF8 - which should help us in our first steps of using York GF8
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York GF8
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York GF8 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York GF8?

Use the form below

If you did not solve your problem by using a manual York GF8, ask a question using the form below. If a user had a similar problem with York GF8 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)