  • Sun Microsystems 4000 - page 1

    901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Sun Enterprise ™ 4000 System Centerplane Upgrade Guide 100 MHz Gigaplane Upgrade for the Sun Enterprise 4000 System Part No. 805-7186-10 January 1999, Revision A Sun Microsystems, Inc. Send comments about this document to: docfeedback@sun.com ...

  • Sun Microsystems 4000 - page 2

    Please Recycle Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road • Palo Alto, CA 94303 USA. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means w ...

  • Sun Microsystems 4000 - page 3

    iii Contents Preface vii Using UNIX Commands vii Typographic Conventions viii Shell Prompts viii Related Documentation ix Sun Documentation on the Web ix Sun Welcomes Your Comments ix 1. System Upgrade Procedure 1 Powering Off the System 1 Removing the Boards and Assemblies 2 Removing the Outer Panels 5 Replacing the Centerplane 8 Replacing the Out ...

  • Sun Microsystems 4000 - page 4

    iv Sun Enterprise 4000 System Centerplane Upgrade Guide • January 1999 ...

  • Sun Microsystems 4000 - page 5

    v Figur es FIGURE 1 Keyswitch in Standby Position 2 FIGURE 2 AC Power Switch—Rear View 2 FIGURE 3 SCSI Tray 3 FIGURE 4 Keyswitch Assembly 4 FIGURE 5 Fan Tray Assembly—System Rear 5 FIGURE 6 Outer Panels—Sun Enterprise 4000 System 7 FIGURE 7 Orientation of Empty System Chassis 8 FIGURE 8 Front and Rear of the System Chassis 9 FIGURE 9 Centerpl ...

  • Sun Microsystems 4000 - page 6

    vi Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 ...

  • Sun Microsystems 4000 - page 7

    vii Pr eface The Sun Enterprise 4000 System Centerplane Upgrade Guide provides procedur es for the 100 MHz gigaplane upgrade for Sun Enterprise™ 4000 systems. As part of this upgrade, the CD-ROM drive and clock board are replaced, and the f lash PROM updated. These instructions are designed to be performed only by an experienced service provider ...

  • Sun Microsystems 4000 - page 8

    viii Sun Enterprise 4000 System Centerplane Upgrade Guide • January 1999 T ypographic Conventions Shell Pr ompts T ABLE P-1 T ypographic Conventions T ypeface Meaning Examples AaBbCc123 The names of commands, files, and directories; on-scr een computer output Edit your .login file. Use ls -a to list all files. % You have mail . AaBbCc123 What you ...

  • Sun Microsystems 4000 - page 9

    ix Related Documentation Sun Documentation on the W eb The docs.sun.com sm web site enables you to access Sun technical documentation on the W eb. Y ou can browse the docs.sun.com archive or sear ch for a specific book title or subject at: http://docs.sun.com Sun W elcomes Y our Comments W e are interested in improving our documentation and welcome ...

  • Sun Microsystems 4000 - page 10

    x Sun Enterprise 4000 System Centerplane Upgrade Guide • January 1999 ...

  • Sun Microsystems 4000 - page 11

    1 System Upgrade Pr ocedur e This chapter gives detailed instructions for upgrading your Sun Enterprise 4000 system. The upgrade procedure includes: ■ Powering off the system—page 1 ■ Removing all Boards and Assemblies—page 2 ■ Removing the Outer Panels—page 5 ■ Replacing the Centerplane—page 5 ■ Replacing the Outer Panels ■ Rep ...

  • Sun Microsystems 4000 - page 12

    2 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 c. T erminal 3. T urn the front panel keyswitch counterclockwise to the Standby position. FIGURE 1 Keyswitch in Standby Position 4. T urn the AC power switch to of f. FIGURE 2 AC Power Switch—Rear V iew Removing the Boar ds and Assemblies Caution – Use a grounding wrist st ...

  • Sun Microsystems 4000 - page 13

    System Upgrade Procedure 3 1. Disconnect all cables from the boards. Squeeze the locking tabs on the sides of the connector body , or loosen any retaining screws (if pr ovided), and pull the connectors out. Note – Label all cables for reconnection. 2. W ith wrist strap on, insert a screwdriver in the notch at the top of the SCSI tray to pull out ...

  • Sun Microsystems 4000 - page 14

    4 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 FIGURE 4 Keyswitch Assembly 5. Remove all the boards and power supplies from the rear of the system and place them on a padded ESD mat. Refer to your system manual for the detailed procedure. Note – Label each board with its r espective slot number , so that each board can b ...

  • Sun Microsystems 4000 - page 15

    System Upgrade Procedure 5 FIGURE 5 Fan T ray Assembly—System Rear 7. Disconnect any remaining cables from the system. Note – Label all cables for reconnection. Removing the Outer Panels 1. Ensure that all cables have been disconnected and that the keyswitch is in the standby position with the key removed. 2. Remove the upper bezel: a. Press th ...

  • Sun Microsystems 4000 - page 16

    6 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 b. Pull the bottom of the panel away from the side, then lift the panel off the chassis. 4. Remove the top panel: a. Remove the square inserts from the corners of the top panel. Press the small dot to tilt the insert up, then lift it off. b. Lift the front corners of the top p ...

  • Sun Microsystems 4000 - page 17

    System Upgrade Procedure 7 FIGURE 6 Outer Panels—Sun Enterprise 4000 System 6. Remove the lower bezel: a. W ith the chassis still upside down, use a f lat-bladed screwdriver to lift the left side of the lower bezel approximately 1/8 of an inch (3 mm). b. Slide the bezel 1/4 of an inch (6 mm) to the left and lift it off the chassis. Key Descriptio ...

  • Sun Microsystems 4000 - page 18

    8 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 7. Place the empty system chassis front side down ( FIGURE 7 ). FIGURE 7 Orientation of Empty System Chassis Replacing the Centerplane The system chassis is in two sections consisting of a front chassis and a rear chassis. The centerplane is located between the two sections of ...

  • Sun Microsystems 4000 - page 19

    System Upgrade Procedure 9 FIGURE 8 Front and Rear of the System Chassis Rear chassis F ront chassis ...

  • Sun Microsystems 4000 - page 20

    10 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 3. Remove the 20 screws that hold the centerplane to the front chassis ( FIGURE 9 ). FIGURE 9 Centerplane Replacement Detail Caution – Use a grounding wrist strap to pr event static damage. 4. W ith a wrist strap on, lift the centerplane out and set it aside. Note – Remem ...

  • Sun Microsystems 4000 - page 21

    System Upgrade Procedure 11 Replacing the Outer Panels 1. Place the system front side down as shown in FIGURE 7 . 2. Replace the lower bezel: a. Align the bezel 1/4 of an inch (6 mm) to the left of the system chassis to engage the tabs. b. Slide it to the right until it locks into position. 3. Replace the bottom panel. Set the panel about an inch b ...

  • Sun Microsystems 4000 - page 22

    12 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 Replacing the Boar ds and Assemblies Caution – Use a grounding wrist strap to pr event static damage. 1. Replace all the boards and power supplies in the front of the system. Note – Insert boards component side down in the front of the system. Refer to your system manual ...

  • Sun Microsystems 4000 - page 23

    System Upgrade Procedure 13 Replacing the Clock Boar d The clock board is located at the top rear of the system, below the peripheral power supply . After replacing the clock board, update the system f lash PROM as shown in “Updating the System Flash PROM” on page 14. Note – The TOD/NVRAM chip must be removed fr om the old clock board and ins ...

  • Sun Microsystems 4000 - page 24

    14 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 4. W ith a wrist strap attached, gently pull the TOD/NVRAM chip from the clock board. 5. Align the TOD/NVRAM chip removed from the original clock board with the connector on the upgrade clock board so that pin 1 on the chip is aligned with pin 1 on the board. ■ A small cres ...

  • Sun Microsystems 4000 - page 25

    System Upgrade Procedure 15 Caution – Some combinations of old and new PROM versions are incompatible, and flash pr ogramming may cause default NVRAM values to overwrite customized NVRAM variables. Be sure to r ecord the custom and default values displayed so that you can restor e them afterward if necessary . 1. Through your web browser , go to ...

  • Sun Microsystems 4000 - page 26

    16 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 2. W ith a wrist strap on, insert a screwdriver in the notch at the top of the SCSI tray to pull out the tray and separate it from the rear slip connectors. FIGURE 11 Removing the SCSI T ray 3. Remove the seven screws on top of the SCSI tray to lift off the tray cover and acc ...

  • Sun Microsystems 4000 - page 27

    System Upgrade Procedure 17 b. T ighten the three captive screws to secure the CD-ROM drive to the SCSI tray . 6. Replace the tray cover with the seven screws removed in Step 3. 7. Place the SCSI tray into the system and tighten the three captive screws securing it to the enclosure ( FIGURE 1 1 ). Powering On the System Note – Refer to Chapter 12 ...

  • Sun Microsystems 4000 - page 28

    18 Sun Enterpr ise 4000 System Centerplane Upgrade Guide • January 1999 ...

Manufacturer Sun Microsystems Category Network Router

Documents that we receive from a manufacturer of a Sun Microsystems 4000 can be divided into several groups. They are, among others:
- Sun Microsystems technical drawings
- 4000 manuals
- Sun Microsystems product data sheets
- information booklets
- or energy labels Sun Microsystems 4000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sun Microsystems 4000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sun Microsystems 4000, service manual, brief instructions and user manuals Sun Microsystems 4000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sun Microsystems 4000.

A complete manual for the device Sun Microsystems 4000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sun Microsystems 4000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sun Microsystems 4000.

A complete Sun Microsystems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sun Microsystems 4000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sun Microsystems 4000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sun Microsystems 4000, that we can find in the current document
3. Tips how to use the basic functions of the device Sun Microsystems 4000 - which should help us in our first steps of using Sun Microsystems 4000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sun Microsystems 4000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sun Microsystems 4000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sun Microsystems 4000?

Use the form below

If you did not solve your problem by using a manual Sun Microsystems 4000, ask a question using the form below. If a user had a similar problem with Sun Microsystems 4000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)