Manual Omron 705CP-II

24 pages 0.39 mb
Download

Go to site of 24

Summary
  • Omron 705CP-II - page 1

    Instruction manual page 1 Gebrauchsanweisung Seite 23 Gebruiksaanwijzing pagina 45 Mode demploi page 67 Istruzioni per luso pagina 89 Instrucciones de uso pagina 1 1 1 Automatic Blood Pressure Monitor & Printer The World Hypertension League recommends regular blood pressure monitoring with clinically validated devices. 705CP-II IM-HEM-759 ...

  • Omron 705CP-II - page 2

    705CP-II English Dear Customer Contents Blood pressure monitor Important instructions to help you obtain meaningful readings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Y our blood pressure monitor: the benefits . . . . . . . . . . . 3 Battery installation / replacement . . . . . . . . . . . . . . . . . . . . 4 How to set ti ...

  • Omron 705CP-II - page 3

    2 705CP-II English The World Hypertension League recommends regular blood pressure monitoring by doctors and patients with clinically validated devices Regular blood pressure monitoring is essential for the prevention, the control and the management of hypertension. It also helps to support the doctors' work. The World Hypertension League is a ...

  • Omron 705CP-II - page 4

    3 705CP-II English ON/OFF (O/I) button ST ART ( ) button OMRON 705CP-II is a compact, fully automatic blood pressure monitor , operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly . It contains an intel ligent “fuzzy logic” system for controlled inflation, known as “Intellisense”. This ...

  • Omron 705CP-II - page 5

    4 705CP-II English Battery installation / replacement  Slide the battery cover off in the direction of the arrow .  Install or replace 4 “LR6” batteries so the + (positive) and – (negative) polarities match the polarities of the battery compartment as indicated.  Replace the battery cover . NOTES : If the Low Battery Indicator ( ) ap ...

  • Omron 705CP-II - page 6

    5 705CP-II English How to set time and date  Install the batteries and press the ON/OFF button. The display will show 0:00  Press and hold the SET button. The year digits (2002) will flash.  Press the ADJUST button to advance the digit(s) one at a time. If you hold down the ADJUST button, the digits will advance rapidly .  Press SETb ...

  • Omron 705CP-II - page 7

    6 705CP-II English How to apply the cuf f (when wrapping on your left arm) • Y ou can wrap the cuff either on your right or left arm.  Insert air tube to air jack (on the left side of the divice). The cuf f must be airless.  Remove tight-fitting clothing from your upper arm.  Sit in a chair with your feet flat on the floor and place your ...

  • Omron 705CP-II - page 8

    7 705CP-II English  Pull the cuff so that the top and bottom edges are tightened evenly around your arm.  When the cuff is positioned correctly , close the velcro fastener FIRML Y .  Make certain the cuff fits snugly around your arm. The cuff should make good contact with your skin. Y ou should be able to fit your index finger between the ...

  • Omron 705CP-II - page 9

    8 705CP-II English How to take a reading  Press the (O/I) button. a) All display symbols appear for approximately one second. b) When the monitor becomes ready to measure, the ( ) symbol appears on the display .  Press the (ST ART ) button and remain still. As the cuff begins to inflate, the monitor automatically determines your ideal inflati ...

  • Omron 705CP-II - page 10

    9 705CP-II English START Continue to press button  When the measurement is complete, the cuff completely deflates and your blood pressure and pulse rate are displayed. NOTE : The monitor automatically stores blood pressure and pulse rate into the memory . • When 28 sets of readings are stored in memory , the oldest set will be deleted to store ...

  • Omron 705CP-II - page 11

    10 705CP-II English How to use the memory function This monitor has a memory capable of storing 28 sets of readings. Every time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. • T urn on the monitor by pressing the (O/I) button. • Press the ( ) button to recall stored readings while the ( ) symbol i ...

  • Omron 705CP-II - page 12

    11 705CP-II English • Before measuring, stretch your back and sit up straight, breath normally 5-6 times, relax your shoulders, arms and entire body . • Slightly bend and support your elbow (e.g. on a table). • Do not move, talk or touch the device during measurement. • Stress influences your blood pressure, so try to relax before taking a ...

  • Omron 705CP-II - page 13

    12 705CP-II English Failure, causes and rectification Failure and their possible causes Incorrect measurement is indicated by 1. A correct reading could not be obtained because measurement was disturbed by movement of the body . 2. The cuff is not fitted correctly . 3. Y our clothing has constricted your blood flow . 4. There is still air in the cu ...

  • Omron 705CP-II - page 14

    13 705CP-II English Maintenance and storage • For cleaning the monitor only use a soft, lightly moistened cloth. Do not use petroleum spirits, thinners or similar solvents ! • Stains on the cuff can be carefully removed using a moist cloth and soapy water . Do not wash the cuff or make it wet ! • Keep your blood pressure monitor in the storag ...

  • Omron 705CP-II - page 15

    14 705CP-II English T echnical data This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Direc tive). This blood pressure monitor is designed according to the European standard EN1060, Non-invasive sphygmo- manometers Part 1: General requirements and Part 3: Supple mentary requirements for electromechani - cal blood pres ...

  • Omron 705CP-II - page 16

    15 705CP-II English OMRON spare parts Calibration The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. It is generally recommended to have the monitor inspected every two years to ensure correct functioning and accuracy . Please consult your authorised dealer or the OMRON Customer Service at ...

  • Omron 705CP-II - page 17

    16 705CP-II English Some useful information about blood pressure What is Blood Pressure ? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the hearts cycle. The highest pressure in the cycle is called the SYST OLIC BLOOD PRESSURE; the ...

  • Omron 705CP-II - page 18

    17 705CP-II English What Causes High Blood Pressure ? Blood pressure is only classed as high if it doesnt go down when you rest. Permanently raised blood pressure can be caused by several factors such as hardening of the arteries, smoking or drinking too much alcohol. It can also be caused by cholesterol, a type of fat, building up inside your b ...

  • Omron 705CP-II - page 19

    18 705CP-II English Introduction The OMRON printer can be conected to OMRON blood pressure monitors with IT functions. Description Paper Feed Print Graph Print All Data Print Current Data/Stop Printing Printer Cover Printer Cable Plug Power/Operation Light Battery installation / replacement  Slide the battery cover off in the direction of the ar ...

  • Omron 705CP-II - page 20

    19 705CP-II English How to connect the printer unit  Remove printer cable plug from the printer unit.  Connect printer cable plug cord to the main unit. The circle on the cable plug should face up.  Open printer cover in the direction indicated by the arrow symbol and remove paper roll from the main unit.  Peel of the glued edge of the ...

  • Omron 705CP-II - page 21

    20 705CP-II English OMRON IT blood pressure monitors have the ability to print all the readings stored in memory . NOTE : • Make sure printer-unit is connected to main unit (see How to Connect Printer-Unit) • Do not use printer-unit without loading printer paper (see How to Load Printer Paper). Improper use will decrease operation life cycle of ...

  • Omron 705CP-II - page 22

    21 705CP-II English • Month(s) The month or months will be printed. Example: If the blood pressure reading was stored between months March-June, then the printout will indicate “3-6”. • Date Only the days date (1-31) will be printed. Example: If the blood pressure reading was stored on June 1st, then the printout will indicate 1 under th ...

  • Omron 705CP-II - page 23

    22 705CP-II English T roubleshooting Error Indicator Cause Correction Printer cable plug is not connected properly or damaged Connect correctly reference p.10 Contact your OMRON distributor . T ake paper jammed from the printer and install again Purchase new printer paper Batteries are worn No readings stored Printer paper is not installed correctl ...

  • Omron 705CP-II - page 24

    OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com OMRON (DALIAN) CO., LTD. Dalian, CHINA OMRON HEALTHCARE UK LTD. Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.K. OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH John ...

Manufacturer Omron Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Omron 705CP-II can be divided into several groups. They are, among others:
- Omron technical drawings
- 705CP-II manuals
- Omron product data sheets
- information booklets
- or energy labels Omron 705CP-II
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron 705CP-II.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron 705CP-II, service manual, brief instructions and user manuals Omron 705CP-II. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron 705CP-II.

Similar manuals

A complete manual for the device Omron 705CP-II, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron 705CP-II by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron 705CP-II.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron 705CP-II - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron 705CP-II, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron 705CP-II, that we can find in the current document
3. Tips how to use the basic functions of the device Omron 705CP-II - which should help us in our first steps of using Omron 705CP-II
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron 705CP-II
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron 705CP-II in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron 705CP-II?

Use the form below

If you did not solve your problem by using a manual Omron 705CP-II, ask a question using the form below. If a user had a similar problem with Omron 705CP-II it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)