  • Hisense Group KFR 25GWE - page 1

    - KFR 33GWE - KFR 33GWE Hisense Corporation INSTR UCTION INSTR UCTION MANU AL MANU AL - KFR 28GWE - KFR 28GWE - KFR 25GWE - KFR 25GWE SPLIT TYPE AIR CONDITIONER SPLIT TYPE AIR CONDITIONER - KFR 2101GWE - KFR 2101GWE - KFR 3201GWE - KFR 3201GWE ...

  • Hisense Group KFR 25GWE - page 2

    RZA-0-1000-862-SM-D Compact Size This model is smaller than its predecessors and yet offers the same capabilities. Microprocessor Controlled Operation The interior compartment of the remote control unit contains several features to facilitate automatic operation, clearly displayed for easy use. Simple One-touch Wireless Remote Control The remote co ...

  • Hisense Group KFR 25GWE - page 3

        Contents 1 Page Alert symbol Caution statements Composition of the air conditioner Operation guide Care and cleaning Tips for energy saving Troubleshooting Schematic diagram Pardon not to inform you if the contents of the manual changes. 1 2 3 8 16 18 18 19 W ARNING CAUTION      Alert Symbols The symbol refers to a hazard or an unsa ...

  • Hisense Group KFR 25GWE - page 4

        Caution Statements W ARNING W ARNING W ARNING CAUTION 2 1.Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button. 2.Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed. 3.Do not let the children play with the air conditi ...

  • Hisense Group KFR 25GWE - page 5

    Air intake grille INDOOR UNIT Air outlet Remote control unit Drain hose Refrigerant tubes OUTDOOR UNIT Air outlet     Composition of the Air Conditioner 3 1.Diagram of Structure This air conditioner consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote control unit. NOTE Air Intake Air Outlet Remo ...

  • Hisense Group KFR 25GWE - page 6

    INDOOR UNIT OPERATING lamp TIMER lamp POWER lamp POWER TIMER OPERATING HIGH POWER lamp REMOTE CONTROL receiver ON/OFF button 4 2.Introduction of the Indoor ControI Unit IMPORTANT : Avoid using radio equipment such as mobile phone near (within 1m) the indoor unit. Some radio equipment may cause maIfunction of the unit. If the troubIe happens, dis- c ...

  • Hisense Group KFR 25GWE - page 7

    Displayed when one-hour OFF timer is enable Displayed when setting timer Displayed when setting temperature Displayed when transmitting data Displayed when temperature is shown Displayed when temperature setting is at the upper or lower allowable limits Displayed when Night Setback is running Displayed when main unit sensor is in use Symbols 1小 ...

  • Hisense Group KFR 25GWE - page 8

    关 预约 1HR HIGH POWER ON/OFF TEMP ON OFF AUTO 1 小时 x C 1HOUR 1HOUR FLAP ON OFF SET CANCEL A/C SENSOR BAT TERY F AN SPEED MODE SENSOR A/C SENSOR button Transmitter Battery compartment (pull off the cover to expose the batteries.) (Cover closed) SET TEMP HOUR HOUR AUTO AUTO ACL SLEEP TEMP . setting button ON/OFF button MODE selector ...

  • Hisense Group KFR 25GWE - page 9

    :The air conditioner starts at the set time. The air conditioner stops at the set time. or :The air conditioner makes the room warm. :The air conditioner reduces the humidity in the room. direction to one of the six possible positions manually, or to select the The airflow direction can be set manually.(six positions) :The flap moves up and down au ...

  • Hisense Group KFR 25GWE - page 10

        Operation Guide B ACL button 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction m arked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. ● or when the remote control unit cannot ...

  • Hisense Group KFR 25GWE - page 11

    Operation with the Remote Control Unit(continued) C 1HR ON/OFF TEMP HIGH POWER FLAP ON OFF SET CANCEL SLEEP A/C SENSOR ACL BATTER Y FA N SPEED MODE STEP 3 STEP 2 STEP 5 AUTO AUTO STEP 4 STEP 1 NOTE Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is in the ON position. If the automati ...

  • Hisense Group KFR 25GWE - page 12

    Adjusting the Fan Speed AUTO AUTO A. Automatic Simply set the FAN SPEED selector to the position. A microcomputer in the air conditioner automatically controls the fan speed when the mode is selected. When the air co nditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is detected by the microcomp ...

  • Hisense Group KFR 25GWE - page 13

    Adjusting the Airflow Direction The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. 2. Vertical 1. Horizontal ! CAUTION When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way ...

  • Hisense Group KFR 25GWE - page 14

    Night Setback / Simultaneous Use Energy Saving C 1HR ON/OFF TEMP HIGH POWER FLAP ON OFF SET CANCEL SLEEP A/C SENSOR ACL BATTER Y FA N SPEED MODE AUTO AUTO ● Night Setback Mode Night Setback Mode is used for saving energy. Press the SLEEP button in operation. The mark appears in the display. T o release the night setback function, press the SLEEPb ...

  • Hisense Group KFR 25GWE - page 15

    ON HOUR HOUR Using the 12-Hour ON and OFF Timer C 1HR ON/OFF TEMP HIGH POWER FLAP ON OFF SET SLEEP A/C SENSOR ACL BATTER Y FA N SPEED MODE STEP 2 STEP 3 STEP 1 1.TIMER ON mode (Example) After the length of time set for TIMER ON elapses, the unit begins operating. The display depicted at left indicates that the air conditioner will begin operati ...

  • Hisense Group KFR 25GWE - page 16

    Using the 1-Hour OFF Timer 14 C 1HR ON/OFF TEMP HIGH POWER FLAP ON OFF SET SLEEP A/C SENSOR ACL BATTER Y FA N SPEED MODE AUTO AUTO 1HOUR 1HOUR This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. The indicator in the display indicates that this function is oper ...

  • Hisense Group KFR 25GWE - page 17

    15 Special Remarks Heating ( ) Operation Heating performance Defrosting POWER lamp ● Because this air conditioner heats a room by drawing on the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner , use another he ...

  • Hisense Group KFR 25GWE - page 18

    Operation without the Remote Control Unit INDOOR UNIT     Care and Cleaning NOTE If you have lost the remote control unit or it has trouble, follow the steps below. 1.When the air conditioner is not running If you want to turn on the air conditioner, pressing the ON/OFF button once. 2.When the air conditioner is running If you want to turn of ...

  • Hisense Group KFR 25GWE - page 19

    Care and Cleaning (continued) Anti-Mold Filter How to remove the anti-mold filter The anti-mode filter behind the air intake grille should be checked and cleaned at least once every three weeks. 1.Grasp both ends of the air intake grille and pull it out and up. 2.Push the anti-mold filter up slightly, and then pull it down. Air intake grille Anti-m ...

  • Hisense Group KFR 25GWE - page 20

        Tips for Energy Saving Do not ● Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. Let sunlight directly into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer time to cool the room. ● Do ● Al ...

  • Hisense Group KFR 25GWE - page 21

        Schematic Diagram 2. Refrigerant Flow Diagram KFR-33GWE AC,230V/50Hz 1220W/1260W 3300W/3550W 。 8m/80 15m 3 450m /h R22/1.30kg 1. Main specifications of the product Type Power source Power consumption of input (cooling/heating) Power (cooling/heating) Air flow (high) Refrigeration dose/consumption Maximum remote control range/ angle rang ...

  • Hisense Group KFR 25GWE - page 22

    1 2 3 4 5 S R C TO INDOOR TERMINAL COMP FAN MOTOR RV YLW/GRN BLK RED RED BLK WHT BLU BLU WHT GRY CAP A YLW/GRN YLW/GRN BRN CAPA PNK 4 WAY V ALUE ASSY 4. Electric Wiring Diagram Outdoor FAN MOTOR 1 2 3 4 5 1 2 3 4 5 123 12 12 12 12 1~8 1~8 135 135 123 1 2 1 2 1 2 1 2 ROOM COIL SU COM CM FM VA FLAP FM PULSE IN SW PRY SEC 0 1 2 3 4 5 ...

  • Hisense Group KFR 25GWE - page 23

    P ACKING LIST NO. NAME AMOUNT PACKING LOCA TION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. OUTDOOR UNIT POWER CABLE DRAINAGE ELBOW * AIR FRESH FIL TER INDOOR UNIT INSTRUCTION MANUAL INSTALLA TION MANUAL REMOTE CONTROL UNIT BA TTERY NAIL SPECIAL BOLT SPECIAL W ARRANTY CARD COVER 1 1 1 1 1 1 1 1 2 6 6 1 1 OUTDOOR OUTDOOR OUTDOOR OUTDOOR INDOOR INDOOR ...

Manufacturer Hisense Group Category Air Conditioner

Documents that we receive from a manufacturer of a Hisense Group KFR 25GWE can be divided into several groups. They are, among others:
- Hisense Group technical drawings
- KFR 25GWE manuals
- Hisense Group product data sheets
- information booklets
- or energy labels Hisense Group KFR 25GWE
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hisense Group KFR 25GWE.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hisense Group KFR 25GWE, service manual, brief instructions and user manuals Hisense Group KFR 25GWE. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hisense Group KFR 25GWE.

A complete manual for the device Hisense Group KFR 25GWE, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hisense Group KFR 25GWE by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hisense Group KFR 25GWE.

A complete Hisense Group manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hisense Group KFR 25GWE - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hisense Group KFR 25GWE, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hisense Group KFR 25GWE, that we can find in the current document
3. Tips how to use the basic functions of the device Hisense Group KFR 25GWE - which should help us in our first steps of using Hisense Group KFR 25GWE
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hisense Group KFR 25GWE
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hisense Group KFR 25GWE in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hisense Group KFR 25GWE?

Use the form below

If you did not solve your problem by using a manual Hisense Group KFR 25GWE, ask a question using the form below. If a user had a similar problem with Hisense Group KFR 25GWE it is likely that he will want to share the way to solve it.

Copy the text from the picture