Manual Anton/Bauer DIONIC 90

20 pages 2.38 mb
Download

Go to site of 20

Summary
  • Anton/Bauer DIONIC 90 - page 1

    ® BATTERY SYSTEM DIONIC ® 90 lithium ion Digital Battery OWNER’S MANUAL ...

  • Anton/Bauer DIONIC 90 - page 2

    TABLE OF CONT ENTS IMPORTANT READ AND UNDERSTAND T HIS MANUAL BEFORE OPER ATION .................................................................... 1 INTRODUCTION .............................................................................. 2 FEATURES ...................................................................................... 3 CHARGIN ...

  • Anton/Bauer DIONIC 90 - page 3

    1 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION The InterActive 2000 Dionic 90 battery lithium ion chemistry delivers a higher power to weight ratio than NiCd & NiMH. However, all lithium ion batteries have more sensitive char ging and discharging param eters and require longer charge times (2-5 hours). See charging section page 5 ...

  • Anton/Bauer DIONIC 90 - page 4

    2 INTRODUCTION The development of this new DIONIC 90 battery sy stem has been made possible through the incorporation of the pioneering InterActive technology of the Anton/Bauer Digital system with the very latest lithium ion cell formulations. Each DIONIC 90 battery features an on-board “fuel computer” to monitor ener gy put into a nd taken ou ...

  • Anton/Bauer DIONIC 90 - page 5

    3 FEATURES 1. Microprocessor Fu el Computer - Accurately monitors the energy in the battery with programs that take into account battery age, self discharge, charge/discharge rate, operating conditions and previously experienced charge/discharge cycles. The DIONIC 90 battery constantly “learns” its precise state of charge and rem aining capacit ...

  • Anton/Bauer DIONIC 90 - page 6

    4 CHARGING DIONIC 90 BATTERIES • DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY CHARGER OTHER THAN THE ANT ON/BAUER InterActive 2000 OR T SERIES CHARGERS SPECIFIED IN THIS MANUAL. • Allow the battery to reach a steady green (LifeS aver ® ) mode before using for the first time. Please read the in dividu al charger Owner’s Manual to be come ac ...

  • Anton/Bauer DIONIC 90 - page 7

    5 NOMINAL CHARGE TIMES FOR DIONIC 90 Charge Le v el LED Indicators 90% Flashing Green 100% Steady Green Dual 2722 (2 batteries simultaneously) 2hrs. 3hrs. InterActive 2000 Pow erCharger (Quad/Dual – 2702/2701/2700) (Quad/Dual – 2401/2400) 2 hrs. 3 hrs. T2 (2 batteries simultaneously) 2hrs. 3hrs. Tandem 70 2hrs. 3hrs. Twin (2 batteries simultane ...

  • Anton/Bauer DIONIC 90 - page 8

    6 The DIONIC 90 features an all NEW “RealTime” LCD display providing on-the-fly remaining run time estimates in 15 minute increm ents as well as simultaneously providing remaining capacity information using the traditional “Fuel Gauge” approach. No s pecial adapters or s et up is required. RealTime automatically calculates the load and disp ...

  • Anton/Bauer DIONIC 90 - page 9

    7 -The large numbers 1, 2 or 3 indicate remaining hours under current load (only one number will display at any one time) -The pie chart numbers ( 15, 30, 45, or 60) indicate remaining minutes under current load. - The InterActive Segment indicates a FULLY CHARGED battery verified by charger communication -Top BAR: Indicates 75%-96% - 2 nd BAR: Ind ...

  • Anton/Bauer DIONIC 90 - page 10

    8 If the SIDE BARS (only) flash AND other icons are lit and not flashing, this indicates the battery has requested to be fully charged and discharged in order to update its “learned capacity”. This “learning” should typically occur during normal equipment operation. However, if the battery has not been fully charged and discharged for some ...

  • Anton/Bauer DIONIC 90 - page 11

    9 RealTime Display Indications • When the DIONIC battery is being charged remaining runtime is not displaye d. • Rem aining run time is calculated using the present available battery capacity and a constantly updated accurate measurement of the present load on the battery. • If no load is detected, or if the battery is removed from the charge ...

  • Anton/Bauer DIONIC 90 - page 12

    10 • W hen the battery is completely discharged the LCD will flash the 15 minute icon and the ‘RES’ bar until the battery is returned to a charger. • If the protection electronics detect a low battery voltage condition (any one cell reaches roughly 2.5Vdc or approximately 10V battery voltage), the LCD sidebars will flash until the battery i ...

  • Anton/Bauer DIONIC 90 - page 13

    11 OPERATING GUIDELINES 1. Keep batteries cool or at room temp eratures whenever poss ible. Sustained elevated temperatures are the primary reason for premature failure of lithium ion batteries: a. Charging - Charge batteries at room temperature. In warm climates keep chargers in air conditioned rooms for best performance. b. On assignment - Do not ...

  • Anton/Bauer DIONIC 90 - page 14

    12 4. Low voltage batteries can also be caused by allowing batteries to remain off the charger for extended periods causing the LCD display to be blank, indicating that the electronic circuitry has removed all load from the battery cells – including the display. In the case that the battery is in a low voltage condition the battery should be retu ...

  • Anton/Bauer DIONIC 90 - page 15

    13 SERVICE In the event a DIONIC 90 battery fails to deliver acceptable performance, it must be returned to the Anton/Bauer. No ot her facility is qualified and equipped to service the InterActive 2000 DIONIC 90 ba tteries and calibrate the electronic components and sensors. Any attempt by the user or any other unauthorized persons to service this ...

  • Anton/Bauer DIONIC 90 - page 16

    14 PRECAUTIONS 1. Do not expose this battery to high temperatures (above 50°C/120°F). This includes storage in direct sunlight , in cars in hot weather, or in close proximi ty to heating devices. This may cause electrolyte leak age, impaired p erformance and shorten ing of battery s ervice life. 2. When not u sing the b attery for prolonged perio ...

  • Anton/Bauer DIONIC 90 - page 17

    15 DIONIC 90 BATTERY SPECIFICATIONS OUTPUT VOLTA GE 14.4v Nominal 12.4 ~ 16.8v Operating CA PA CITY (CELL CA PA CITY) 90 WH Nominal (6.3 AH Rated) FUSE Internal 8amp RECOMMENDED OPERA TION 15 - 50 watts 1 (MAXIMUM DISCHARGE RATE) (90 watts) 2 TYPICA L RUN-TIME @ 20w - 4 ½ hrs. @ 25w - 3 ½ hrs. @ 40w - 2 ¼ hrs. WEIGHT 1.7 lbs SIZE 5 1/4 x 3 1/2 x ...

  • Anton/Bauer DIONIC 90 - page 18

    16 LIMITED WARRANTY This w arranty for the ba ttery product specif ied in this doc ume nt (“ Product”) is g iven by A nton/Bauer , Inc. (“Anton/Baue r”), 14 Progres s Driv e, Shelton, Conne cticut 06484. I f y ou (the purchas er of the Product f rom A nton/Bauer , or the person for whom the Product wa s purchas ed, if it wa s a gi ft) ha ve ...

  • Anton/Bauer DIONIC 90 - page 19

    17 Dangerous Goods Regulations 49C FR Parts 100-185, Air Transport Association (IATA) and the International Civil Aviation Organization (ICAO) regulations a pply to all lithium ion battery transport. Air Transportation Declaration Anton/Bauer, Inc. declares that the Dionic 90 lith ium ion b attery pack contains equivalent lithium c onte nt (ELC) in ...

  • Anton/Bauer DIONIC 90 - page 20

    7595-0243 Rev M The power behind the best cameras capturing the best im ages in the world. sm The following are trademarks of Anton/Bauer, Inc.: ACS, ADM, All Chem, Anton/Bauer, Anton/Bauer logo and parallelogram design, Automatique, Egripz, Elightz, Elipz, Essentialz, DataTap, Dionic, Gold Mount, Hy TRON, Im pac, InterActive and design, Life Saver ...

Manufacturer Anton/Bauer Category Camcorder Accessories

Documents that we receive from a manufacturer of a Anton/Bauer DIONIC 90 can be divided into several groups. They are, among others:
- Anton/Bauer technical drawings
- DIONIC 90 manuals
- Anton/Bauer product data sheets
- information booklets
- or energy labels Anton/Bauer DIONIC 90
All of them are important, but the most important information from the point of view of use of the device are in the user manual Anton/Bauer DIONIC 90.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Anton/Bauer DIONIC 90, service manual, brief instructions and user manuals Anton/Bauer DIONIC 90. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Anton/Bauer DIONIC 90.

A complete manual for the device Anton/Bauer DIONIC 90, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Anton/Bauer DIONIC 90 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Anton/Bauer DIONIC 90.

A complete Anton/Bauer manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Anton/Bauer DIONIC 90 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Anton/Bauer DIONIC 90, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Anton/Bauer DIONIC 90, that we can find in the current document
3. Tips how to use the basic functions of the device Anton/Bauer DIONIC 90 - which should help us in our first steps of using Anton/Bauer DIONIC 90
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Anton/Bauer DIONIC 90
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Anton/Bauer DIONIC 90 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Anton/Bauer DIONIC 90?

Use the form below

If you did not solve your problem by using a manual Anton/Bauer DIONIC 90, ask a question using the form below. If a user had a similar problem with Anton/Bauer DIONIC 90 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)