Manual Bradford White 50T65F

28 pages 1.55 mb
Download

Go to site of 28

Summary
  • Bradford White 50T65F - page 1

    The Bradford White Flammable V apor Ignition Resistant W ater Heater SER VICE MANU AL T roub leshooting Guide and Instr uction f or Ser vice (T o be perf or med ONL Y b y qualified ser vice providers) MI30T*F(BN,CX) MI30S*F(BN, CX) MI303T*F(BN,CX) MI40T*F(BN,CX) MI403S*F(BN,CX) MI404T*F(BN,CX) MI503*F(BN,CX) MI50L*F(BN,CX) MI504S*F(BN,CX) MI60T*F(B ...

  • Bradford White 50T65F - page 2

    3 Table of Contents Page Service Procedure Introducti o n 3 --- T rouble shooting Ch art 4 - - - In ner Door Gasket Removal, Inspection, Replacement and Install ation T hermocouple Testing and Replaceme nt P ilot Assembly Inspection Cleaning and Replacement 10 RG-III Piezo Igniter and Electrode Testing 11 RG-IV Combination Thermostat/Gas Valve Test ...

  • Bradford White 50T65F - page 3

    4 INTRODUCTION The Bradf ord White DEFENDER Safety System ® The Bradford White DEFENDER Safety System ® w as designed to resist the ignition of flammable v apors that can occur outside of the water heater . Use and installation are nearly identical to pre vious versions of atmosphericall y f ired and vented w ater heaters. A number of e xclusiv e ...

  • Bradford White 50T65F - page 4

    5 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Pilot Will Not Light 1. No incoming gas or too low gas pressure. 2. Gas control knob set to wrong position. 3. Pilot light button not being fully depressed when attempting to light pilot. 4. Pilot orifice or pilot tube is obstructed or kinked. 5 . Pilot electrode not sparking to pilot. 6 . Piezo igniter no ...

  • Bradford White 50T65F - page 5

    6 Inner Door R emov al Procedure Step 1. Rotate knob of the c ombination thermostat/gas valve to the “O F F” p osition. Step 2. Remove outer jacket b urner a c cess door Step 3. Inner Door Removal. a) Disco nne ct resettable thermal switch wire l eads (l eading from comb i nat ion t hermostat/g as valve). b) Remove (2) 1/4" hex drive screw ...

  • Bradford White 50T65F - page 6

    7 Installat ion of Inner Door With Gasket. WARNING Stripped fastener connections may allow for seal breach of inner door. A seal breach may result in a fire or explosion causing property damage, personal injury or death. Do not over tighten screws in steps 8, 10 and 11. If a fastener connection is stripped, contact the manufacturer listed on the wa ...

  • Bradford White 50T65F - page 7

    8 S tep 10. Firmly place r ight s ide inner door flange a gainst the left side inner door fl ange and se cure with two ¼” drive s crews from step 3 c. DO NOT OVER TIGHTEN SCREWS . S tep 11. A lign r ight side inner do or to comb ustion cham ber and verify the fastener holes of the combustion cha mber are a lig ned with the r ight side inner doo ...

  • Bradford White 50T65F - page 8

    9 Step 1. C losed circuit t esting is the pref erred method for t esting t hermocoup le. Fol low in g the lightin g instruc tion label on the heate r, p roceed to light th e pi lot and a l low to oper ate f or three minue ts. If the pilot will not stay lit, hold the pilot button ( located on t he c ombi nation therm ost at/gas valve) down durin g t ...

  • Bradford White 50T65F - page 9

    10 THERM OCOUPLE REPLACEMENT Step 1. Turn off gas supply to water heate r. Rot ate knob of c ombination therm ostat/gas valve to “O FF” position. Step 2. R emo ve outer jacket door. Step 3. R emo ve right side of inner door per SERVICE PROCEDURE RG-I, steps 3a through 3c. Step 4 Disconnect thermocouple f rom co mbina tion th ermostat/gas valve ...

  • Bradford White 50T65F - page 10

    11 PILOT/ELECTRODE ASSEMBLY I NSPECTION, CLEA NING AND R EPLACEMENT S tep 1. Turn off gas sup ply to wa ter h eat er. Rotate knob of combination thermostat/gas valve to “O F F” position. Step 2. Remove outer jacket door. S tep 3. Remove r ight side of inner door per SERVICE PROCEDURE RG-I , steps 3a thro ugh 3c. Step 4 Disco nne ct thermocouple ...

  • Bradford White 50T65F - page 11

    12 PIEZO IGNITER, ELECT RODE TESTING AND REP LACEMENT Wi th the pilot not in opera tion ( no pilot fl ame) you can check t he Piezo and e lect rode ci r cuit by v iew ing pilot thru the sight glass locat ed on the i nner do or and ob servi ng the spark a ction. S tep 1. R emove outer jack et door. Step 2. R epeatedly depr ess t he P iezo igniter wh ...

  • Bradford White 50T65F - page 12

    13 The combination thermostat/gas valve is a n on repairable devi ce. If tr ouble sho otin g has de termin ed a probl em with the combina tion t her mostat/gas valve, it must be r eplaced. If the burner and/or pilot do not function, service checks for gas pressu re, thermoco uple output, magnet assembly and ECO are to be performed. If these check O ...

  • Bradford White 50T65F - page 13

    14 Se e SERVICE P ROCED URE RG-II THE RMOCOUPLE TESTING MAGNET ASSEMBLY TESTING (Whi te Rodgers Control) Step 1. Following the light ing i nstru ction l abel on t he h eat er, p roceed to light the pilot and allow to operate for three minuets. If the pilot will not stay lit, hol d the pilot button (lo cat ed on the c ombination thermosta t/gas v al ...

  • Bradford White 50T65F - page 14

    15 COMBI NATION THE RMOSTAT/GAS VALVE REPLACEMENT Step 1. Rotate knob of the comb i nati on t hermostat/ gas valve to the “OFF” p osition. Step 2. Turn off gas supply to water heater. Step 3. Disconne ct gas s upply line from combina tion t hermostat/ gas valve. Step 4. Turn off water supply and drain water heater completely. Step 5. Remove out ...

  • Bradford White 50T65F - page 15

    16 Step 7. Removal of combination thermostat/gas valve. a) Disconnect main burner feed line (¾” wrench), pilot tube (7/16" wrench) and thermocouple (3/8" wrench) from combination thermostat/gas valve & remove burner from combustion chamber. NOTE: Feed line nut for natural gas control uses right hand threads, LP control uses left ha ...

  • Bradford White 50T65F - page 16

    17 Step 9. Reinstallation of inner door assembly. (cont.) b) Clean an y gasket residue or other debris from comb ustion cha mber surface before installing the inner door/gasket assembly. c) Position thermocouple, pilot tube and Pie zo wi re a gain st left side inn er door flange g asket. DO NOT ROUTE THROUGH RADIUSED CHANNEL WITH FEED LINE. Be s ur ...

  • Bradford White 50T65F - page 17

    18 S tep 1. With ma in burn er in o perati on, rem ove right side inner door p er s erv ice p rocedu re I, s teps 3b & 3c. Be sure to maintain wire connection to reset table th er mal s witch for this a djustm ent proce dure. Step 2. To ad just for proper burning, loosen the air sh utte r n ut, r ota te the s hutter to clos e the opening in the ...

  • Bradford White 50T65F - page 18

    19 Step 3. Fully inspect inner gasket pe r S ERVICE PROCED URE R G-I, s tep 4. Replace g asket if r equi red f ollowing SERVICE PROCEDURE I, steps 5 & 6. Step 4. Be ce rtain t hat thermo couple, pilot tube and piezo wire are routed by inner door flange as shown and Reinstall inner door per SERVICE P ROCEDURE R G-I, s tep 1 0 and 11. Step 5. Obs ...

  • Bradford White 50T65F - page 19

    20 S tep 5. D isconn ect ( unscr ew) M ain burner (stamped steel “B” burner) from m ain burner orifi ce or on cast ir on burners (“C” burner), loosen air shutter & disconnect ( unscrew) feedline from b urner. Step 6. Remove main b urner orifi ce f rom feed line (½” wrench on steel b urner, 3/8 " wrench on cast iron). Inspe ct an ...

  • Bradford White 50T65F - page 20

    21 Step 1. Remove outer jacket door. Step 2. Disconnect wire leads fro m r esetta ble thermal s witch. Step 3. Using a m ultimeter capa ble of meas uring continuity (Ohms), pl ace one probe of m eter on one of the brass con nec tion tabs of the resettab le thermal switch, a nd the re maini ng p robe on the other connection tab. Step 4. If continuit ...

  • Bradford White 50T65F - page 21

    22 RESETTABLE THERMAL SWITCH REPLACEMENT S tep 1. Rotate k nob of combination thermostat gas valve to the off position. S tep 2. Remove outer jacket door. Step 3. D isconne ct wire l eads from resetta ble thermal switch. S tep 4. Remove resettable th erm al swi tch from inner door (Phillips screw driver) Step 5. Pla ce new resettable thermal switc ...

  • Bradford White 50T65F - page 22

    23 Step 1. R otate knob of c ombination thermostat gas valve to the off position. Step 2. R emove outer jacket door. S tep 3. Remove inner door per S ERVI CE PROCEDURE RG -I, step 3a through 3e. Step 4. Disconnect main b urn er feed line (¾ wrench), pilot tube (7/16 wre nch) a nd t hermocoup le (3/8) wrench from com bination thermostat gas valve a ...

  • Bradford White 50T65F - page 23

    24 S tep 1. Rotate knob o f combina tion ther mostat/ gas valve to “OFF” position. S tep 2. Turn off cold water supply to heater. Connect ho se to dra in spigot of w ater h eater a nd route to an open drain. Open a nearby hot water faucet to vent he ater f or drainin g. Open drain sp igot of hot water h eat er and a l low heater to drain to a p ...

  • Bradford White 50T65F - page 24

    25 S tep 1. Turn off wa ter sup ply to water h eat er. Ro ta te knob of c ombinat ion t hermostat/ga s valve to “OFF” position. S tep 2. Turn off cold water supply to heater. Connect ho se to dra in spigot of w ater h eater a nd route to an open drain. Open a nearby hot water faucet to vent he ater f or drainin g. Open drain sp igot of hot wate ...

  • Bradford White 50T65F - page 25

    26 1 Draf t Hood 2 Hot Water Outlet/Anode 3 Cold Water Inlet Tube 4 Flue Baffle 5 T&P Relief Valve 6 Thermostat 7 Piezo Igniter 8 Brass Drain Valve 9 Screw-#8-18 x 3/4 Hex Washer Head 10 Screw-#10-12 x 3/4 Hex Washer Head 11 Left S ide Inner Door with Gasket 12 Complete Right Si de Inner Door 14 Resetta ble Thermal Switch 15 Screw #6-20 x 3/8 P ...

  • Bradford White 50T65F - page 26

    NOTES ...

  • Bradford White 50T65F - page 27

    NOTES ...

  • Bradford White 50T65F - page 28

    Application & Sizing/ 800-523-2931 Fax/ 215-641-1612 Email parts@bradfordwhite.com techserv@bradfordwhite.com www .bradfordwhite.com www .bradfordwhitecanada.com ...

Manufacturer Bradford White Category Water Heater

Documents that we receive from a manufacturer of a Bradford White 50T65F can be divided into several groups. They are, among others:
- Bradford White technical drawings
- 50T65F manuals
- Bradford White product data sheets
- information booklets
- or energy labels Bradford White 50T65F
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bradford White 50T65F.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bradford White 50T65F, service manual, brief instructions and user manuals Bradford White 50T65F. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bradford White 50T65F.

A complete manual for the device Bradford White 50T65F, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bradford White 50T65F by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bradford White 50T65F.

A complete Bradford White manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bradford White 50T65F - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bradford White 50T65F, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bradford White 50T65F, that we can find in the current document
3. Tips how to use the basic functions of the device Bradford White 50T65F - which should help us in our first steps of using Bradford White 50T65F
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bradford White 50T65F
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bradford White 50T65F in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bradford White 50T65F?

Use the form below

If you did not solve your problem by using a manual Bradford White 50T65F, ask a question using the form below. If a user had a similar problem with Bradford White 50T65F it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)