Manual Uni-T UT362

30 pages Not applicable
Download

Go to site of 30

Summary
  • Uni-T UT362 - page 1

    1 UT361/UT362 OPERA TING MANUAL T able of Contents Title Page Overview Unpacking Inspection Rules For Safety Operation The Anemoscope Structure Display Symbols Setting Up The Anemoscopes Using The Anemoscopes Measuring Wind Speed Computer Connectivity (For UT362 only) Maintenance T echnical Specification 2 3 4 7 8 14 16 21 23 24 27 ...

  • Uni-T UT362 - page 2

    2 UT361/UT362 OPERA TING MANUAL Overview Model UT361 and UT362 are an anemoscopes with high accurate sensitive resistance (NTC) as testing point. For fan axis, it uses a high durable ruby shaft in order to provide the accurate and stable measurement. It also comes with 8 digits chip to conduct the digital mode and double display (VEL + T emperature ...

  • Uni-T UT362 - page 3

    3 UT361/UT362 OPERA TING MANUAL Item 1 2 3 4 Description English Operating Manual USB Interface Cable (UT362) only Software (UT362) only 9 V Battery Software Qty 1 piece 1 piece 1 piece 1 piece W arning T o avoid electric shock or personal injury , read the "Rules for Safe Operation" carefully before using the Anemoscope. Unpacking Inspec ...

  • Uni-T UT362 - page 4

    4 UT361/UT362 OPERA TING MANUAL In the event you find any missing or damage, please contact your dealer immediately . In this manual, a W arning identifies conditions and actions that pose hazards to the user , or may damage the anemoscopes or the equipment under test. A Note identifies the information that user should pay attention to. Rules For S ...

  • Uni-T UT362 - page 5

    5 UT361/UT362 OPERA TING MANUAL T o avoid possible electric shock or personal injury and to avoid possible damage to the anemoscopes or to the equipment under test, adhere to the following rules Do not use your hand to touch the fan and / or the measurement of wind count and temperature portion Replace the battery as soon as the battery indicator a ...

  • Uni-T UT362 - page 6

    6 UT361/UT362 OPERA TING MANUAL Use the specific authorized replacement part if you need to repair the anemoscopes Do not use the anemoscopes if the opening the housing cover Note the battery " + " and " - "pole when battery insert. Followings are the condition which cause anemoscopes damages. Please carefully use it to avoid an ...

  • Uni-T UT362 - page 7

    UT361/UT362 OPERA TING MANUAL The Anemoscope Structure (see figure 1) Fan Wind Speed Indicator Handle Secondary Display Primary Display Power Button Operational Button Main Unit 1 2 3 4 5 7 6 8 Figure 1 7 ...

  • Uni-T UT362 - page 8

    8 UT361/UT362 OPERA TING MANUAL Display Symbols (see figure 2) Figure 2 ...

  • Uni-T UT362 - page 9

    9 UT361/UT362 OPERA TING MANUAL Functional Signs Below table indicated for information about the functional sign operations. Number 1 2 3 4 5 6 7 8 9 Sign MAX MIN A VE READ REC NO. USB VEL Meaning Display of Maximum Reading Display of Minimum Reading Data Hold is on Display of Average Reading Display of Data Storage Measurement Reading Display of D ...

  • Uni-T UT362 - page 10

    10 UT361/UT362 OPERA TING MANUAL Number 10 1 1 12 13 14 15 16 17 18 Meaning Secondary Data Display Primary Data Display Wind Speed Unit - Foot Per Minute Wind Speed Unit - Meter Per Second Fahrenheit T emperature Signal / Centigrade T emperature Signal Cubic Feet Per Second Cubic Meter Per Minute Knots Per Hour Miles Per Hour Sign ft/min m/s / CFM ...

  • Uni-T UT362 - page 11

    1 1 UT361/UT362 OPERA TING MANUAL Display Symbols (see figure 3) Figure 3 Function Key Description Power on / Power off Button Button 1 - This button function key switch is for wind speed measurement and wind count measurement. During wind speed measurement, press "UNIT" button m/s ft/min KNOTS Km/h MPH and vice versa. During wind count m ...

  • Uni-T UT362 - page 12

    UT361/UT362 OPERA TING MANUAL 12 Button 5 - Display the data download to USB port (For UT362 only) Description Button 2 - Press this button to choose In wind speed measurement: maximum reading, minimum reading and the instant measuring unit exchange In wind count measurement: maximum reading, minimum reading, average reading, 2/3V maximum value and ...

  • Uni-T UT362 - page 13

    13 UT361/UT362 OPERA TING MANUAL Function Key Description Button 7 - Press this button to activate the REC feature. Press and Hold this button to access data reading from database Button 8 - Press this button to erase the data records before power on. The data reduction shows on the database as well Button 9 - It is a functional menu button. Press ...

  • Uni-T UT362 - page 14

    14 UT361/UT362 OPERA TING MANUAL Setup up the Anemoscopes Press and hold button 9 (menu) to select feature setup. Press next button to go next feature sub-menu. A. USB setup Press button 8 from USBO USB1. Then set up is as the opening default B. Auto Switch Down Press button 8 from AP00 AP01 and store in after power off. The default keep it and nee ...

  • Uni-T UT362 - page 15

    15 UT361/UT362 OPERA TING MANUAL This default keep it and no need to reset when power on. D. Master Reset LCD shows the DEF with flash. Y ou can reset your anemoscopes to the factory settings. Press button 2 of to the factory settings for USBO, APO1, 60S data clearing. Press button 9 (menu) to cancel the factory setting. Then enter wind speed measu ...

  • Uni-T UT362 - page 16

    16 UT361/UT362 OPERA TING MANUAL Using the Anemoscopes Power On: Press "Power " button for a while to switch the anemoscopes on Wind Speed and Wind Count Feature Switch: Press VEL / FLOW button. VEL (wind speed) to FLOW (wind count) Data Hold: Press " Hold " button to data capture, then press again to cancel the data capture fea ...

  • Uni-T UT362 - page 17

    17 UT361/UT362 OPERA TING MANUAL Wind pipe input area: 1) Correct input the wind pipe area before wind count measurement 2) Set default area is one square meter after the entering wind count measurement. 3) Select the approiate wind count-measuring unit. The press " Sample " button to enter area input. LCD shows KEYIN blank on the top. 4) ...

  • Uni-T UT362 - page 18

    18 UT361/UT362 OPERA TING MANUAL Enter 1, ENTET Mean 1 LCD display " 1.000 " Enter 0, 0, 0, 1 Mean 0001 LCD display " 1.000 " Enter ., 0, 0, 1 Mean . 001 LCD display " 0.001 " ... ... ... In one area, it will probably to have a different input methods but finally it has one display: Data Input Range: 0.000~9999 T emper ...

  • Uni-T UT362 - page 19

    19 UT361/UT362 OPERA TING MANUAL Data Storage Functions: 1) LCD display " No Data " if no data storage 2) LCD display " T ime " if database is full and cannot store any data in the current time. 3) Manual data storage: press button 7 to display the automatic data storage in LCD, also LCD displays REC and around 0.5 seconds to di ...

  • Uni-T UT362 - page 20

    20 UT361/UT362 OPERA TING MANUAL 5) Record Clearing Method 1: Press and hold button 8 until LCD appear CLR when power on. Method 2: Resume to factory setting (see function setting stuff) Press and hold button 7 to view the data records of wind speed measurement and wind count measurement.It automatically display last data record. LCD will be displa ...

  • Uni-T UT362 - page 21

    Screw Wind Figure 4 Measuring For Wind Speed (Wind Count) (see figure 4) Note: before use, the wind speed is over 10m/s under 1 - 2 minutes duration. T o carry out anemoscopes, follow the following procedure: 1. Press on " Power " button until the anemoscopes on 2. Press VEC / FLOW (figure 4) to conduct function switch. LCD shows either & ...

  • Uni-T UT362 - page 22

    22 UT361/UT362 OPERA TING MANUAL 4. Use figure 4 to conduct wind speed measurement , it shows wind flow direction, but bear in mind W arning do not use it in opposite. A screw can fix on it. (Note: UNI-T will not provide this screw to the customer , the customer need to buy it separately) 5. W ait for 2 seconds to obtain a more precise reading duri ...

  • Uni-T UT362 - page 23

    23 UT361/UT362 OPERA TING MANUAL Computer Connectivity (For UT362 only)(see figure 5) When use the anemoscopes model UT362 need to connect USB cable with the computer Connect the USB interface cable, the anemoscope and the computer as reference to the figure 5 Figure 5 White Computer ...

  • Uni-T UT362 - page 24

    24 UT361/UT362 OPERA TING MANUAL Maintenance A. Replacing The Battery T o avoid false reading, which could read to possible electronic shock or personal injury , replace the battery as soon as the battery indicator " " appears. T o replace the battery 1) T urn the anemoscope off and remove all the connections from the input terminals 2) T ...

  • Uni-T UT362 - page 25

    25 UT361/UT362 OPERA TING MANUAL 5) Rejoin the case bottom and the battery compartment and reinstall the screw . B. Cleaning Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. C. Service And Repairing This anemoscope is an auto calibration. Do not attempt to repair or service your anemoscope unless yo ...

  • Uni-T UT362 - page 26

    26 UT361/UT362 OPERA TING MANUAL 2) T ake out the battery when it is not using for a long time. 3) Do not use or store the Meter in a place of humidity , high temperature, explosive, inflammable and strong magnetic field. Environmental Requirements Operating T emperature Range: 0 ~50 ( 32 ~ 122 ) Relative Humidity: 0 ~75%, no condensation Storage T ...

  • Uni-T UT362 - page 27

    27 UT361/UT362 OPERA TING MANUAL Range 2~10 m/s 10~30 m/s UT362 (3%+0.5) (3%+0.8) UT361 (3%+0.5) (3%+0.8) Accuracy T echnical Specification Wind Speed Measurement ...

  • Uni-T UT362 - page 28

    28 UT361/UT362 OPERA TING MANUAL T emperature Measurement T emperature Main Unit T emperature Sensor T emperature Range 0 ~40 32 ~ 104 0 ~40 32 ~ 104 UT362 3 4 3 4 UT361 3 4 3 4 Accuracy ** END ** ...

  • Uni-T UT362 - page 29

    29 UT361/UT362 OPERA TING MANUAL This operating manual is subject to change without notice. ...

  • Uni-T UT362 - page 30

    30 UT361/UT362 OPERA TING MANUAL ...

Manufacturer Uni-T Category Anemometer

Documents that we receive from a manufacturer of a Uni-T UT362 can be divided into several groups. They are, among others:
- Uni-T technical drawings
- UT362 manuals
- Uni-T product data sheets
- information booklets
- or energy labels Uni-T UT362
All of them are important, but the most important information from the point of view of use of the device are in the user manual Uni-T UT362.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Uni-T UT362, service manual, brief instructions and user manuals Uni-T UT362. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Uni-T UT362.

Similar manuals

A complete manual for the device Uni-T UT362, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Uni-T UT362 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Uni-T UT362.

A complete Uni-T manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Uni-T UT362 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Uni-T UT362, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Uni-T UT362, that we can find in the current document
3. Tips how to use the basic functions of the device Uni-T UT362 - which should help us in our first steps of using Uni-T UT362
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Uni-T UT362
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Uni-T UT362 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Uni-T UT362?

Use the form below

If you did not solve your problem by using a manual Uni-T UT362, ask a question using the form below. If a user had a similar problem with Uni-T UT362 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (1)

carlos maidana

si una consulta tenemos 4 anemometro Uni-T UT362 y queremos el registro de la medicion en la computadora, si puede hacer el favor de explicar el procedimiento. gracias.