Manual Friedrich SV12A10

27 pages 1.01 mb
Download

Go to site of 27

Summary
  • Friedrich SV12A10 - page 1

    Room Air Conditioner Ser vice and P ar ts Man ual Slider Casement SV08 / SV10 / SV12 (01/03) 115V olts • SV08A10 • SV10A10 • SV12A10 High Cool Med Fan Off Mode Temperature Med Cool Low Cool Low Fan Cooler Warmer ...

  • Friedrich SV12A10 - page 2

    —2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ................................2 1.2 INSULATION RESISTANCE TEST .................2 1.3 SPECIFICATIONS ...........................................3 1.4 FEATURES......................................................4 1.5 CONTROL LOCATIONS .................................4 2. DISASSEMBL Y INSTR UCTIONS 2.1 ...

  • Friedrich SV12A10 - page 3

    —3— POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (BTU/W . h) INDOOR (°C) OUTDOOR (°C) REFRIGERANT (R-22) CHARGE EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP. CONTROL AIR DIRECTION CONTROL CONSTRUCTION PROTECTOR COMPRESSOR FAN MOTOR POWER CORD DRAIN SYS ...

  • Friedrich SV12A10 - page 4

    —4— 1.4 FEA TURES • Designed for COOLING ONLY. • Powerful and whispering cooling. • Simple installation and service. • Low air-intake, top cooled-air discharge. 1.5 CONTR OL LOCA TIONS 1.5.1 COOLING ONL Y MODEL • VENTILATION The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When a fr ...

  • Friedrich SV12A10 - page 5

    — 5 — 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the inlet grille downward and remove the air filter. 2. Remove the screws which fasten the front grille.(See Figure 1) 3. Pull the front grille from the right side. 4. Remove the front grille.(There are 4 hooks.) 5. Re-install the components by referring to the removal procedure, above. 2. ...

  • Friedrich SV12A10 - page 6

    — 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE AND TURBO F AN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the control box. (Refer to section 2.1.3) 4. Remove the 4 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the upper air guide. (See F ...

  • Friedrich SV12A10 - page 7

    — 7 — 2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the shroud. (See Figure 8) 3. Re-install the components by referring to the removal procedure, above. 2.3 ELECTRICAL P AR TS 2.3.1 O VERLO AD PRO TECT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the nut which fastens the terminal cover. 3. Remove the termi ...

  • Friedrich SV12A10 - page 8

    — 8 — 2.3.3 CAP A CIT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the screw and the clamp which fastens the capacitor. 3. Disconnect all the leads of capacitor terminals. 4. Re-install the components by referring to the removal procedure, above. (See Figure 11) 2.3.4 PO WER CORD 1. Remove the cabinet. (Refer to section 2.1.2) 2 ...

  • Friedrich SV12A10 - page 9

    — 9 — 2.3.7 MO T OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the turbo fan. (Refer to section 2.2.1) 3. Remove the fan. (Refer to section 2.2.2) 4. Remove the 4 screws which fasten the motor from the Motor Mount. (See Figure 15) 5. Remove the motor. 6. Re-install the components by referring to the removal procedure, above.(See ...

  • Friedrich SV12A10 - page 10

    — 10 — — Replacement of the refrigerant. 1. When replacing the refrigerant, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM . Leave the valve in place after servicing the system. 2. After discharging ...

  • Friedrich SV12A10 - page 11

    — 11 — Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SIDE) SEE INSETS BELOW MAN ...

  • Friedrich SV12A10 - page 12

    — 12 — 3. INST ALLA TION 3.1 HO W T O INST ALL THE UNIT 1. To avoid vibration and noise, make sure the unit is installed securely and firmly. 2. Install the unit where the sunlight does not shine directly on the unit. If the unit receives direct sunlight, build an awning to shade the cabinet. 3. There should be no obstacle, like a fence, within ...

  • Friedrich SV12A10 - page 13

    — 13 — 3.4 WINDO W REQUIREMENTS 1. These instructions are for a horizontal sliding or a casement window. 2. The electrical outlet must be within reach of the power cord. For installation in a casement window, the window frame assembly and the side of the building must be adequate to support the weight of the air conditioner. 3.5 INST ALLA TION ...

  • Friedrich SV12A10 - page 14

    —14— 1. Loosely attach the support bracket to the bottom of bracket using bolts, washers, and nuts. Attach the leveling bolt and nut. (See Figure 22) 2. Remove protective backing from window track seal and apply seal to window track. (See Figure 23) 3. Measure and lightly mark a line 8-1/4 inches from window jamb. Center the support bracket ass ...

  • Friedrich SV12A10 - page 15

    — 15 — 8. Slide curtain into curtain frame. Slide curtain frame assembly into side guides of the air conditioner cabinet. Make sure curtain is firmly enclosed on all sides by the frame. (See Figure 27) 9. Cut side guide seal into 2 equal lengths. Remove protective backing and apply it to the rear side of cabinet side guides, starting just below ...

  • Friedrich SV12A10 - page 16

    — 16 — 4. TR OUBLESHOO TING GUIDE 4.1 OUTSIDE DIMENSIONS 368(14 1 / 2 ) 521(20 1 / 2 ) 607(23 3 / 5 ) CAPILLARY TUBE COMPRESSOR TURBO F AN EV APORA TOR COIL CONDENSER COIL FA N MOTOR 4.2 PIPING SYSTEM Following is a brief description of the important components and their functions in the refrigeration system. Refer to Fig. 31 to follow the refr ...

  • Friedrich SV12A10 - page 17

    — 17 — 4.3 TR OUBLESHOO TING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but poor cooling. Ineffective Cooling Check ou ...

  • Friedrich SV12A10 - page 18

    — 18 — Fails to Start Check circuit break er and fuse. Gas leakage of f eeler bulb of ther mostat Check of control s witch. F an only fails to start. Improper wiring. Def ect of f an motor capacitor . Irregular motor resistance ( ). Irregular motor insulation ( ). Replacement of f an motor . T ests nor mal but f ails to star t. Replacement of c ...

  • Friedrich SV12A10 - page 19

    — 19 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective. Connect wire. Refer to wiring diagram for terminal identification. R ...

  • Friedrich SV12A10 - page 20

    — 20 — COMPLAINT CAUSE REMEDY Check the position of knob If not at the coldest setting, advance the knob to this setting and restart unit. Check continuity of the thermostat. Replace thermostat if circuit is open. Check the capacitor. Replace if not within ±10% of manufacturers rating. Replace if shorted, open, or damaged. Check the compressor ...

  • Friedrich SV12A10 - page 21

    5. SCHEMA TIC DIA GRAM 5.1 CIRCUIT DIA GRAM ■ MODEL : SV10A10 / SV12A10 — 21 — SV10A10 SV12A10 PART NO. 1 POWER CORD 6411A20011N 6411A20011P 1 S 2 ROTARY SWITCH 2H00598E 1 S 3 FAN MOTOR 4681A20069C 1 S 4 CAPACITOR 6120AR2194P 0CZZA20001N 1 S 5 THERMOSTAT 2H01109Q 1 S 6 COMPRESSOR 2520UKAC2GA 2520UKGC2DA 1S LOCATION NO. DESCRIPTION RE- MARKS Q ...

  • Friedrich SV12A10 - page 22

    — 22 — 5.2 CIRCUIT DIA GRAM ■ MODEL : SV08A10 SV08A10 PART NO. 1 POWER CORD 6411A20011L 1 S 2 ROTARY SWITCH 2H00598E 1 S 3 FAN MOTOR 4681A20069A 1 S 4 CAPACITOR 6120AR2359H 1 S 5 THERMOSTAT 2H01109M 1 S 6 COMPRESSOR 2520UAGC2AA 1S LOCATION NO. DESCRIPTION RE- MARKS Q'TY PER SET S: Service Parts N: Non Service Parts ...

  • Friedrich SV12A10 - page 23

    6. EXPLODED VIEW — 23 — 554030 148000 352390 349001 349600 346811 354210 152312 147581 145200 147582-2 135312 147582-1 135301 264110 269310 266003 249950 130910 359011 130410 552111 352113 352380 149980 W0CZZ 567502 554160 550140 349480 135303 359012 352115 35211A 149410 H i g h C o o l M e d F a n O f f M o d e M e d C o o l L o w C o o l L o ...

  • Friedrich SV12A10 - page 24

    — 24 — 7. REPLA CEMENT P AR TS LIST ■ MODEL : SV08A10, SV10A10, SV12A10 P/No SV08A10 SV10A10 SV12A10 130410 BASE ASSY, SINGLE 3041A20033J 3041A20033N R 130910 CABINET ASSY, SINGLE 3091A20014A R 135303 GRILLE INLET 3530A20056A R 135312 GRILLE ASSY, FRONT 3531A20123A R 147581 VANE, HORIZONTAL 4758A20032A R 147582 VANE, VERTICAL 4758A20017A / 47 ...

  • Friedrich SV12A10 - page 25

    — 25 — MEMO ...

  • Friedrich SV12A10 - page 26

    — 26 — MEMO ...

  • Friedrich SV12A10 - page 27

    Printed in the U.S.A Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.: 3828A20190G SV08 / SV10 / SV12 (01/03) Use F actor y Cer tified P ar ts... ...

Manufacturer Friedrich Category Air Conditioner

Documents that we receive from a manufacturer of a Friedrich SV12A10 can be divided into several groups. They are, among others:
- Friedrich technical drawings
- SV12A10 manuals
- Friedrich product data sheets
- information booklets
- or energy labels Friedrich SV12A10
All of them are important, but the most important information from the point of view of use of the device are in the user manual Friedrich SV12A10.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Friedrich SV12A10, service manual, brief instructions and user manuals Friedrich SV12A10. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Friedrich SV12A10.

Similar manuals

A complete manual for the device Friedrich SV12A10, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Friedrich SV12A10 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Friedrich SV12A10.

A complete Friedrich manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Friedrich SV12A10 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Friedrich SV12A10, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Friedrich SV12A10, that we can find in the current document
3. Tips how to use the basic functions of the device Friedrich SV12A10 - which should help us in our first steps of using Friedrich SV12A10
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Friedrich SV12A10
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Friedrich SV12A10 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Friedrich SV12A10?

Use the form below

If you did not solve your problem by using a manual Friedrich SV12A10, ask a question using the form below. If a user had a similar problem with Friedrich SV12A10 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)