Manual Pelco TXB-AD

32 pages 0.51 mb
Download

Go to site of 32

Summary
  • Pelco TXB-AD - page 1

    INST ALLA TION/OPERA TION TXB-AD T ranslator Board C1492M-I (8/05) ...

  • Pelco TXB-AD - page 2

    2 C1492M-I (8/05) Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Important Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description . . . . . . . ...

  • Pelco TXB-AD - page 3

    C1492M-I (8/05) 3 Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE Thi ...

  • Pelco TXB-AD - page 4

    4 C1492M-I (8/05) Important Notice All companies make changes and improvements in their products on a regular basis. Because this product is interfacing with equipment not manufactured by Pelco, the possibility exists that the interface protocols have changed or are in a different confi guration from earlier tested units; therefore, an incompatibi ...

  • Pelco TXB-AD - page 5

    C1492M-I (8/05) 5 Description The TXB-AD translator board allows American Dynamics controllers to communicate with Pelco’ s Esprit ® , ExSite ™ , and Spectra ® systems. Once installed the Spectra dome, ExSite, or Esprit system receives Manchester code commands from the American Dynamics controller and converts the commands into Pelco’ s D p ...

  • Pelco TXB-AD - page 6

    6 C1492M-I (8/05) Esprit Integrated Positioning System Installation The following items are supplied: 1 TXB-AD translator board (printed circuit board) 1 4-40 screw with lock washer (for Spectra II ® Series only) 1 6-32 screw with lock washer (for Spectra III ™ Series only) TXB-AD T RANSLATOR BOARD INSTALLATION AND SETTINGS 1. T urn off the powe ...

  • Pelco TXB-AD - page 7

    C1492M-I (8/05) 7 2. Set the J1 jumper on the TXB-AD to the proper termination setting. The TXB-AD is shipped from the factory with the J1 jumper in the terminated position. To unterminate the unit remove the cover from the J1 jumper and then place the cover over one pin for storage. Refer to Figure 2 and Figure 3. Figure 2. TXB-AD T ranslator Boar ...

  • Pelco TXB-AD - page 8

    8 C1492M-I (8/05) 4. Install the TXB-AD translator by inserting the 16-pin connector located on the back of the TXB-AD board into the mating connector on the Esprit system’s board. Refer to Figure 1 and Figure 2. 5. Reinstall the nut and washer on the standoff to secure the translator board. ESPRIT SYSTEM SETTINGS AND CONNECTIONS 1. V erify that ...

  • Pelco TXB-AD - page 9

    C1492M-I (8/05) 9 Figure 5. How to Install Cover 4. Remove the pan and tilt from the base of the Esprit System. Check the control wiring inside the base of the unit. NOTE: T o wire the connector for the controller, refer to the manual supplied with the American Dynamics controller . 5. Reinstall the pan and tilt onto the base of the unit. Apply pow ...

  • Pelco TXB-AD - page 10

    10 C1492M-I (8/05) Spectra Dome Installation The following items are supplied: 1 TXB-AD translator board (printed circuit board) 1 4-40 screw with lock washer (for Spectra II Series only) 1 6-32 screw with lock washer (for Spectra III Series only) TXB-AD T RANSLATOR BOARD INSTALLATION AND SETTINGS 1. T urn off the power to the dome system. Remove t ...

  • Pelco TXB-AD - page 11

    C1492M-I (8/05) 11 Figure 7. Receiver Location 3. Set DIP switches on the TXB-AD. Refer to Figure 6 and T able A. 4. Install the TXB-AD board. Refer to Figure 8 and Figure 9 and do the following: a. Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open. b. Remove the shorting plug from the 16-pi ...

  • Pelco TXB-AD - page 12

    12 C1492M-I (8/05) Figure 8. Spectra Dome System, Interconnect Door Figure 9. Spectra Dome System, Circuit Board 1 2 3 4 5 6 7 AUX2 GND GND TX+ TX- RX+ RX- VIDEO ALARMS GND AUX1 AUX2 TX+ TX- GND RX+ RX- VIDEO RELAYS 16-PIN CONNECTOR ...

  • Pelco TXB-AD - page 13

    C1492M-I (8/05) 13 SPECTRA SYSTEM SETTINGS AND CONNECTIONS 1. Check the wiring to the controller. NOTE: T o wire the connector for the controller, refer to the manual supplied with the American Dynamics controller . 2. Close the interconnect door . 3. V erify that all SW1 (Spectra II) or SW3 (Spectra III) switches on the dome drive are set to the O ...

  • Pelco TXB-AD - page 14

    14 C1492M-I (8/05) ExSite Explosionproof System Installation The following items are supplied: 1 TXB-AD translator board 1 4-40 screw with lock washer (for Spectra II Series only) 1 6-32 screw with lock washer (for Spectra III Series only) TXB-AD T RANSLATOR BOARD INSTALLATION AND SETTINGS 1. T urn off the power to the ExSite system. 2. Remove the ...

  • Pelco TXB-AD - page 15

    C1492M-I (8/05) 15 3. Set the J1 jumper on the TXB-AD to the proper termination setting. The TXB-AD is shipped from the factory with the J1 jumper in the terminated position. To unterminate the unit, remove the cover from the J1 jumper and then place the cover over one pin for storage. Refer to Figure 13 and Figure 14. Figure 13. TXB-AD T ranslator ...

  • Pelco TXB-AD - page 16

    16 C1492M-I (8/05) 4. Install the TXB-AD board on the power module. Refer to Figure 15 and do the following: a. Remove the shorting plug from the 16-pin connector on the ExSite system’s circuit board. NOTE: Do not discard the 16-pin shorting plug. Save the plug in case the system ever is converted back to a coax video system or a Pelco-controlled ...

  • Pelco TXB-AD - page 17

    C1492M-I (8/05) 17 EXSITE EXPLOSIONPROOF SYSTEM SETTINGS 1. Check wiring to controller . 2. V erify that all SW3 switches on the ExSite system are set to the OFF position. For American Dynamics controllers with only 32 presets: Set SW3-1 to the ON position. Refer to Figure 13 for switch location. 3. Set the address for the ExSite system. Refer to T ...

  • Pelco TXB-AD - page 18

    18 C1492M-I (8/05) Operation Activate preset 70 to access the camera menus. See below for information on how the translator performs. This shows how the AD keyboard relates to the Pelco translator . AD Keyboard Function Unit Action Pelco Function Spectra III/ExSite Special Function Pan, tilt, zoom, focus, and iris functions Moves unit accordingly P ...

  • Pelco TXB-AD - page 19

    C1492M-I (8/05) 19 48 call shot Sets focus speed 3 Lens focus speed 3 49 call shot Moves unit to home position Home position 50 call shot T urns turbo mode OFF N/A 51 call shot T urns turbo mode ON* N/A 52 call shot N/A N/A 53 call shot N/A N/A 54 call shot Activates auxiliary 4 Sets auxiliary 4 55 call shot Activates auxiliary 5 Sets auxiliary 5 5 ...

  • Pelco TXB-AD - page 20

    20 C1492M-I (8/05) * When turbo mode is turned ON, the last speed (full right or left on the joystick) activates turbo action. ** Must be enabled in Spectra menu. 45 set shot Sets start point of 2nd half- length pattern Start point for pattern 3 46 set shot N/A N/A 47 set shot N/A N/A 48 set shot N/A N/A 49 set shot Sets zero pan Sets zero pan 50 s ...

  • Pelco TXB-AD - page 21

    C1492M-I (8/05) 21 T roubleshooting Symptom Ensure Check/Perform Unit does not respond properly to controller . Make sure your controller is trying to communicate with the unit and not another camera. – Are the pins on the translator board inserted properly into the mother board? (If not, damage to the translator may occur .) – Is it set to the ...

  • Pelco TXB-AD - page 22

    22 C1492M-I (8/05) Appendix T able A. TXB-AD DIP Switch Settings Switch Position Result 1 OFF ON Spectra III/ExSite setting Spectra II/Esprit setting 2 OFF ON Speeds will match AD Ultra Dome Speeds will match older (before revision 2.00) TXB-AD versions 3 OFF ON T urbo mode enabled on power-up T urbo mode disabled on power-up 4 OFF ON Normal TXB-AD ...

  • Pelco TXB-AD - page 23

    C1492M-I (8/05) 23 T able B. American Dynamics Camera Assignments Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Group 7 Group 8 Address 16 5 129 193 257 321 385 449 1 26 6 130 194 258 322 386 450 2 36 7 131 195 259 323 387 451 3 46 8 132 196 260 324 388 452 4 56 9 133 197 261 325 389 453 5 67 0 134 198 262 326 390 454 6 77 1 135 199 263 327 391 4 ...

  • Pelco TXB-AD - page 24

    24 C1492M-I (8/05) 42 106 170 234 298 362 426 490 42 43 107 171 235 299 363 427 491 43 44 108 172 236 300 364 428 492 44 45 109 173 237 301 365 429 493 45 46 110 174 238 302 366 430 494 46 47 111 175 239 303 367 431 495 47 48 112 176 240 304 368 432 496 48 49 113 177 241 305 369 433 497 49 50 114 178 242 306 370 434 498 50 51 115 179 243 307 371 43 ...

  • Pelco TXB-AD - page 25

    C1492M-I (8/05) 25 T able B. American Dynamics Camera Assignments (Continued) Group 9 Group 10 Group 11 Group 12 Group 13 Group 14 Group 15 Group 16 Address 513 577 641 705 769 833 897 961 1 514 578 642 706 770 834 898 962 2 515 579 643 707 771 835 899 963 3 516 580 644 708 772 836 900 964 4 517 581 645 709 773 837 901 965 5 518 582 646 710 774 838 ...

  • Pelco TXB-AD - page 26

    26 C1492M-I (8/05) The chart in T able B shows how to address ExSite/Esprit positioning systems and Spectra domes when using an AD controller . Each of the 16 AD groups has its own communication line that controls 64 devices; hence, each group on the chart contains 64 dome addresses. To use the chart: 1. Find the desired camera number. For example, ...

  • Pelco TXB-AD - page 27

    C1492M-I (8/05) 27 T able C. Switch Settings for SW2 Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 1O N OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3O N O N OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5O N OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7O N O NO N OFF OFF O ...

  • Pelco TXB-AD - page 28

    28 C1492M-I (8/05) 41 ON OFF OFF ON OFF ON OFF OFF 42 OFF ON OFF ON OFF ON OFF OFF 43 ON ON OFF ON OFF ON OFF OFF 44 OFF OFF ON ON OFF ON OFF OFF 45 ON OFF ON ON OFF ON OFF OFF 46 OFF ON ON ON OFF ON OFF OFF 47 ON ON ON ON OFF ON OFF OFF 48 OFF OFF OFF OFF ON ON OFF OFF 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OF ...

  • Pelco TXB-AD - page 29

    C1492M-I (8/05) 29 T able D. Switch Settings for SW1 Receiver Address Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 1O N OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3O N O N OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5O N OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7O N O NO N OFF OFF O ...

  • Pelco TXB-AD - page 30

    30 C1492M-I (8/05) 41 ON OFF OFF ON OFF ON OFF OFF 42 OFF ON OFF ON OFF ON OFF OFF 43 ON ON OFF ON OFF ON OFF OFF 44 OFF OFF ON ON OFF ON OFF OFF 45 ON OFF ON ON OFF ON OFF OFF 46 OFF ON ON ON OFF ON OFF OFF 47 ON ON ON ON OFF ON OFF OFF 48 OFF OFF OFF OFF ON ON OFF OFF 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OF ...

  • Pelco TXB-AD - page 31

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products and the following fixed camera model ...

  • Pelco TXB-AD - page 32

    United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 ...

Manufacturer Pelco Category Home Security System

Documents that we receive from a manufacturer of a Pelco TXB-AD can be divided into several groups. They are, among others:
- Pelco technical drawings
- TXB-AD manuals
- Pelco product data sheets
- information booklets
- or energy labels Pelco TXB-AD
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pelco TXB-AD.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pelco TXB-AD, service manual, brief instructions and user manuals Pelco TXB-AD. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pelco TXB-AD.

Similar manuals

A complete manual for the device Pelco TXB-AD, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pelco TXB-AD by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pelco TXB-AD.

A complete Pelco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pelco TXB-AD - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pelco TXB-AD, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pelco TXB-AD, that we can find in the current document
3. Tips how to use the basic functions of the device Pelco TXB-AD - which should help us in our first steps of using Pelco TXB-AD
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pelco TXB-AD
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pelco TXB-AD in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pelco TXB-AD?

Use the form below

If you did not solve your problem by using a manual Pelco TXB-AD, ask a question using the form below. If a user had a similar problem with Pelco TXB-AD it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)