  • Raypak XFYRE 300 - page 1

    up to 99% Efficiency! Can be vented with PVC MBTU Models 300 • 400 • 500 • 700 • 850 CSA V erified lead Content Less Than .25% Pb Ultra Low Emissions ...

  • Raypak XFYRE 300 - page 2

    2 Up to 99% part load! X treme Outdoor Performance XFyr e T Condensing Modulating Boiler - The Green Choice Raypak’ s new XFyre T is a natural extension of our successful XTherm T modulating vertical boiler line (1,1.5, 2 Million BTUH) . Raypak offers new features not found in other mod-con style boilers and combines these desirable features into ...

  • Raypak XFYRE 300 - page 3

    3 1. W ater Inlet As low as 50°F entering. All copper and brass factory installed vertical plumbing connections . Vertical plumbing allows boilers to be installed side by side or in tight places if need be . Male NPT connections . 2. W ater Outlet All copper and brass factory installed vertical plumb - ing connections . Male NPT connections . 3. L ...

  • Raypak XFYRE 300 - page 4

    4 1. Flue Outlet Category IV - PVC, CPVC and Stainless steel certified. T he XFyre ships PVC ready , no extras to purchase! 2. High V oltage W iring Box 120VA C main incoming power connections . Boiler pump wiring and DHW pump wiring. Alarm power out. 3. Gas Inlet T he XFyre will operate at 100% full rate with gas pres - sures as low as 4.0”w .c. ...

  • Raypak XFYRE 300 - page 5

    5 X tremely Small Footprint Ratings shown are for elev ations up to 10,000 feet. F or installations at elevations above 2,000 feet, der ate may apply , please consult the factory for additional instructions . F ront 24” 24” Rear 24” 24” Right 0” 0” Left 0” 0” T op 12” 24” Floor 0” --- V ent 1” --- C e r t i f i e d M i n i m ...

  • Raypak XFYRE 300 - page 6

    6 X tremely Easy to Wire 300 28 17 19 8 14 5 14 5 40 36 28 16 400 38 18 25 7 19 4 19 4 40 47 29 16 500 47 16 31 7 24 4 24 4 40 56 23 17 700 66 30 44 13 33 7 33 7 40 70 34 19 850 80 40 53 17 40 9 40 9 40 80 40 20 XFyre Model 20°F GPM D T 40°F 30°F Minimum Flow* Rates Of Flow And Pressure Drops 300 1711 1140 855 684 570 489 428 380 342 400 2275 15 ...

  • Raypak XFYRE 300 - page 7

    7 Boiler Contr ol and On-Boar d Diagnostic Center Raypak’ s XFyre comes equipped with a microprocessor control center that displays its information on a 2x20 character LCD display in plain English. All set-up and programming is done at this interface . Control monitors boiler system status including safeties , ignition faults and also stores up t ...

  • Raypak XFYRE 300 - page 8

    ASME Section IV , National Board Registered, 160 PSI • H Stamp v v Heat Exchanger T ubes • 316L Stainless Steel v v Stainless Steel • CSA V erified AB-1953 CA low lead compliant v v Pressure Relief V alve • 60 PSI V v (loose) • 125 PSI v V • 30, 45, 75, 150 PSI V V T emperature & Pressure Gauge (Loose) v v Pump • 120V , Single-Pha ...

Manufacturer Raypak Category Boiler

Documents that we receive from a manufacturer of a Raypak XFYRE 300 can be divided into several groups. They are, among others:
- Raypak technical drawings
- XFYRE 300 manuals
- Raypak product data sheets
- information booklets
- or energy labels Raypak XFYRE 300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Raypak XFYRE 300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Raypak XFYRE 300, service manual, brief instructions and user manuals Raypak XFYRE 300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Raypak XFYRE 300.

Similar manuals

A complete manual for the device Raypak XFYRE 300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Raypak XFYRE 300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Raypak XFYRE 300.

A complete Raypak manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Raypak XFYRE 300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Raypak XFYRE 300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Raypak XFYRE 300, that we can find in the current document
3. Tips how to use the basic functions of the device Raypak XFYRE 300 - which should help us in our first steps of using Raypak XFYRE 300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Raypak XFYRE 300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Raypak XFYRE 300 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Raypak XFYRE 300?

Use the form below

If you did not solve your problem by using a manual Raypak XFYRE 300, ask a question using the form below. If a user had a similar problem with Raypak XFYRE 300 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)