Manual Extron electronic RCP 2000

27 pages 4.91 mb
Download

Go to site of 27

Summary
  • Extron electronic RCP 2000 - page 1

    © 2008 Extron Electronics. All rights reserved. Ex tron US A - We st Headquar te rs + 80 0.6 33 .9 876 Inside U SA / Ca nada O nly +1 .7 1 4.4 91 .1 50 0 +1 .7 1 4.4 91 .1 51 7 FA X Ex tron US A - Eas t + 80 0.6 33 .9 876 Inside U S A / C anad a O nly +1 .9 19 .8 63 .1 79 4 +1 .9 19 .8 63 .1 79 7 FA X Ex tron Europ e + 800 .3 98 7. 66 73 Inside E ...

  • Extron electronic RCP 2000 - page 2

    Pr ecautions This symbol is intended to alert the user of important opera ting and ma intenanc e (servic ing) instr uctions i n the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Rea ...

  • Extron electronic RCP 2000 - page 3

    安全须知 • 中文 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 这个符号警告用户该设备机壳内有暴 露的危险电压,有触电危险。 注意 阅读说明书 • 用户使用该设备前必须阅读并理 解所有安全和使用说明。 保存说明书 • 用户应保存安全说明 ...

  • Extron electronic RCP 2000 - page 4

    RCP 2000 with ISS 506 Support • Quick Start Guide Quick Start Guide — RCP 2000 with ISS 506 Support QS-1 Step 1 T urn the equipment of f and disconnect it from the power source. Make sure that the ISS 506 and all attached devices ar e turned off and, if applicable, disconnected from the power sour ce. Step 2 Set the RCP 2000 on a table, podium, ...

  • Extron electronic RCP 2000 - page 5

    i RCP 2000 with ISS 506 Support • T able of Contents i RCP 2000 with ISS 506 Support • Quick Start Guide Quick Start Guide — RCP 2000 with ISS 506 Support, cont’d QS-2 Step 4 Complete the procedur e for installing the ISS 506. (Refer to the ISS 506 User ’ s Manual for installation procedures.) Step 5 Attach power cords to the ISS 506, the ...

  • Extron electronic RCP 2000 - page 6

    ii RCP 2000 with ISS 506 Support • T able of Contents T able of Contents, cont’d RCP 2000 with ISS 506 Support Sizing an iage .................................................................... 3-17 Resizing in PIP ode ...........................................................3-17 Centering an iage ................................... ...

  • Extron electronic RCP 2000 - page 7

    RCP 2000 with ISS 506 Support • Introduction Intr oduction RCP 2000 with ISS 506 Support • Introduction 1-2 1-3 About this Manual This manual contains information about the Extron RCP 2000 Remote Control Panel with ISS 506 Support, and describes how to connect and operate it. About the RCP 2000 with ISS 506 Support The Extron RCP 2000 remote co ...

  • Extron electronic RCP 2000 - page 8

    RCP 2000 with ISS 506 Support • Introduction Introduction, cont’d 1-4 RCP 2000 with ISS 506 Support 2 Chapter T wo Installation Installation Overview Back Panel Features and Connections Making an RCP Communication Cable ...

  • Extron electronic RCP 2000 - page 9

    RCP 2000 with ISS 506 Support • Installation Installation RCP 2000 with ISS 506 Support • Installation 2-2 2-3 Installation Overview Follow these steps to set up and install the RCP 2000 with ISS 506 support: 1 T urn all of the equipment of f. Make sure that the ISS 506 and all attached devices are turned of f and, if applicable, disconnected f ...

  • Extron electronic RCP 2000 - page 10

    RCP 2000 with ISS 506 Support • Installation Installation, cont’d 2-4 RCP 2000 with ISS 506 Support • Installation 2-5 Ethernet link The RCP 2000 can also communicate with the ISS 506 via an Ethernet link, using the RJ-45 connectors on the RCP and the ISS. The RJ-45 connector is illustrated at right. The RCP 2000 can be connected to the ISS e ...

  • Extron electronic RCP 2000 - page 11

    RCP 2000 with ISS 506 Support • Installation Installation, cont’d 2-6 RCP 2000 with ISS 506 Support 3 Chapter 3 Operation T op Panel Controls Setting Up IP Communication Setting Up RS-232 Communication Setting the Display Mode Using a Cut T ransition Sub-effects Using the Picture Controls Resetting ...

  • Extron electronic RCP 2000 - page 12

    RCP 2000 with ISS 506 Support • Operation Operation RCP 2000 with ISS 506 Support • Operation 3-2 3-3 T op Panel Controls The top panel contains the buttons, knobs, and the T -handle that are used to set up and contr ol the RCP 2000 with the ISS 506. FREEZE BL AC K 1 2 3 4 5 6 7 8 CONT BRIGHT H DIMMER V COLOR TINT WIPE DISSO LV E TA KE FREEZE B ...

  • Extron electronic RCP 2000 - page 13

    RCP 2000 with ISS 506 Support • Operation Operation, cont’d 3-4 RCP 2000 with ISS 506 Support • Operation 3-5 e T ransmit and Receive LEDs — These LEDs icker whenever Ethernet or RS-232 data to or from the ISS 506 is being transmitted or received by the RCP 2000. f Adjust knob — Allows adjustment of menu selections. See “Setting the ...

  • Extron electronic RCP 2000 - page 14

    RCP 2000 with ISS 506 Support • Operation Operation, cont’d 3-6 RCP 2000 with ISS 506 Support • Operation 3-7 2 3 4 5 6 7 8 CUT CONT BRIGHT H V COLOR TINT WIPE DISSOL VE T AKE 2 3 4 5 6 7 8 PROGRAM ADJUST PICTURE CONTROLS PREVIEW ION LOGO 1 /BLACK LOGO 2 /BLACK LOGO 1 /BLACK LOGO 2 /BLACK SIZE CENTER DET AIL AU TO IMAGE Press and hold all fou ...

  • Extron electronic RCP 2000 - page 15

    RCP 2000 with ISS 506 Support • Operation Operation, cont’d 3-8 RCP 2000 with ISS 506 Support • Operation 3-9 3 . Press Cut two times, until the switcher IP address is displayed in the LCD window . The Color/T int button ashes. 4 . Set the switcher ’s IP addr ess to 000.000.000.000 as follows: a . Press one of the pictur e control button ...

  • Extron electronic RCP 2000 - page 16

    RCP 2000 with ISS 506 Support • Operation Operation, cont’d 3-10 RCP 2000 with ISS 506 Support • Operation 3-11 T o enter wipe mode, 1 . Press and hold the W ipe button. 2 . While holding down the W ipe button, repeatedly pr ess the Dissolve button until “W ipe” is displayed on the LCD screen (see the example at right). 3 . If necessary , ...

  • Extron electronic RCP 2000 - page 17

    RCP 2000 with ISS 506 Support • Operation Operation, cont’d 3-12 RCP 2000 with ISS 506 Support • Operation 3-13 3 . If necessary , select a preview input. 4 . T o execute a switch with the dissolve ef fect, press the T ake button, which blinks while the transition is in progr ess. -or- Slide the T -bar up or down to control the dissolve durat ...

  • Extron electronic RCP 2000 - page 18

    RCP 2000 with ISS 506 Support • Operation Operation, cont’d 3-14 RCP 2000 with ISS 506 Support • Operation 3-15 • In from the top and bottom edges to the center of the screen — Soft Center In (#06) or Hard Center In (#18) • Out from the center to the top and bottom edges of the screen — Soft Center Out (#07) or Hard Center Out (#19) C ...

  • Extron electronic RCP 2000 - page 19

    RCP 2000 with ISS 506 Support • Operation Operation, cont’d 3-16 RCP 2000 with ISS 506 Support • Operation 3-17 4 . Release the W ipe button and, while the button remains lit, rotate the Adjust knob to set the amount of seconds that the sub-effect will appear on the scr een. Y ou can set the duration of the PIP sub-ef fect in increments of te ...

  • Extron electronic RCP 2000 - page 20

    RCP 2000 with ISS 506 Support • Operation Operation, cont’d 3-18 RCP 2000 with ISS 506 Support 4 Chapter 4 Ether net Contr ol Establishing a Connection Logging On and Viewing System Status Using the Configuration Screens Managing Files 3 . Rotate the H and V Adjust knobs to move the window or the image up and down (V knob) or left and right (H ...

  • Extron electronic RCP 2000 - page 21

    RCP 2000 with ISS 506 Support • Ethernet Control Ether net Contr ol RCP 2000 with ISS 506 Support • Ethernet Control 4-2 4-3 RCP 2000 System Status screen 4 . When nished viewing, click Log Off in the upper -right corner of the screen to exit the system. Using the Configuration Screens When the Conguration tab is selected, two Congura ...

  • Extron electronic RCP 2000 - page 22

    RCP 2000 with ISS 506 Support • Ethernet Control Ethernet Control, cont’d 4-4 RCP 2000 with ISS 506 Support • Ethernet Control 4-5 RCP 2000 System Settings screen Entering IP and date/time settings T o change system settings, 1 . Select the Conguration tab. 2 . If the System Settings screen is not displayed, click System Settings on the si ...

  • Extron electronic RCP 2000 - page 23

    RCP 2000 with ISS 506 Support • Ethernet Control Ethernet Control, cont’d 4-6 RCP 2000 with ISS 506 Support • Ethernet Control 4-7 Updating the firmware Also available on the Conguration tab is the Firmware Upgrade screen. This scr een lets you check and, if necessary , update the rmware for the RCP unit. N When you upload a version of ...

  • Extron electronic RCP 2000 - page 24

    RCP 2000 with ISS 506 Support • Ethernet Control Ethernet Control, cont’d 4-8 RCP 2000 with ISS 506 Support • Ethernet Control 4-9 File Management screen 2 . Click the Browse button. On the Choose File window , browse to locate the le that you want to upload, and open it. The le name and the path to it are displayed in the le name ? ...

  • Extron electronic RCP 2000 - page 25

    RCP 2000 with ISS 506 Support • Ethernet Control Ethernet Control, cont’d 4-10 RCP 2000 with ISS 506 Support A Appendix A Specifications and Part Numbers Specifications Part Numbers ...

  • Extron electronic RCP 2000 - page 26

    RCP 2000 with ISS 506 Support • Specications and Part Nubers S p e c i fi c a t i on s and P a r t Numbers RCP 2000 with ISS 506 Support • Specications and Part Nubers A-2 A-3 Specifications — RCP 2000 with ISS 506 Support Control/Remote — Contr ol Panel Serial control port ......................... RS-232, 9-pin female D conn ...

  • Extron electronic RCP 2000 - page 27

    RCP 2000 with ISS 506 Support • Specications and Part Nubers Sp ecifi cati ons and Par t Numbers, cont ’d A-4 ...

Manufacturer Extron electronic Category Universal Remote

Documents that we receive from a manufacturer of a Extron electronic RCP 2000 can be divided into several groups. They are, among others:
- Extron electronic technical drawings
- RCP 2000 manuals
- Extron electronic product data sheets
- information booklets
- or energy labels Extron electronic RCP 2000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Extron electronic RCP 2000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Extron electronic RCP 2000, service manual, brief instructions and user manuals Extron electronic RCP 2000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Extron electronic RCP 2000.

A complete manual for the device Extron electronic RCP 2000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Extron electronic RCP 2000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Extron electronic RCP 2000.

A complete Extron electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Extron electronic RCP 2000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Extron electronic RCP 2000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Extron electronic RCP 2000, that we can find in the current document
3. Tips how to use the basic functions of the device Extron electronic RCP 2000 - which should help us in our first steps of using Extron electronic RCP 2000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Extron electronic RCP 2000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Extron electronic RCP 2000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Extron electronic RCP 2000?

Use the form below

If you did not solve your problem by using a manual Extron electronic RCP 2000, ask a question using the form below. If a user had a similar problem with Extron electronic RCP 2000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)