Manual Omron M6 Comfort

36 pages 0.67 mb
Download

Go to site of 36

Summary
  • Omron M6 Comfort - page 1

    IM-HEM-7321-E-01-08/2013 English Français Deutsch Italiano Español Nederlands Ɋɭ ɫɫɤɢɣ Türkçe 2298869-1A Automatic Blood Pressure Monitor Model M6 Comfort Instruction Manual ...

  • Omron M6 Comfort - page 2

    1 2 b c d b a J N O ...

  • Omron M6 Comfort - page 3

    P S R Q T Z W V X Y AA A M N D F E J G K H L AF AE AD H AB O H G I B C U H AC ...

  • Omron M6 Comfort - page 4

    Vérifier les composants suivants ! Prüfen Sie folgende T eile des Lieferumfangs! Controllare i componenti indicati di seguito! $úD÷ÕGDNLELOHúHQOHULNRQWUROHGLQ ¡Compruebe los siguientes componentes! Controleer de volgende onderdelen! ɉɪɨɜɟɪɶ ɬɟɫɥɟɞɭɸɳɢɟ ɤɨ ɦɩɨɧɟɧɬɵ ! English Français Deutsch Ita lia ...

  • Omron M6 Comfort - page 5

    Contents Thank you for purchasing the OMRON M6 Comfort Automatic Blood Pressure Monitor . The OMRON M6 Comfort is a compact, fully automatic blood pressure monitor , operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly . For comfortable controlled inflation without the need of pressure pre-sett ...

  • Omron M6 Comfort - page 6

    1 EN Import ant Safety Info rmation Warnin g: Indi cat e s a p ot ent ial ly ha za rd ous s it u a t i on whi ch , if n ot av o ide d , c o uld res u lt in de at h o r seri ous in jury . (General Usage) Consult your physician before using the device in pregnancy including pre-eclampsia, or if diagnosed with arrhythmia or arteriosclerosis. Do not us ...

  • Omron M6 Comfort - page 7

    2 Impor tant Safety Informatio n If there are any abnormalities during the measurement, remove the arm cuff. Do not use this device on i nfants or persons who cannot express their intentions. Do not inflate the arm cuff more than necessary . Do not use the device for any purpose other t han measuring blood pressure. Use only the approved arm cuff f ...

  • Omron M6 Comfort - page 8

    3 Impor tant Safety Informatio n EN (Battery Usage) Do not insert the batteries with their pol arities incorrectly aligned. Use only 4 “AA” alkaline or manganese batteries with this devi ce. Do not use other types of batteries. Do not use new and used bat teries together . Remove the batteries if the device will not be used for three months or ...

  • Omron M6 Comfort - page 9

    4 1. Know Y our Device Monitor Display Cuff wrap guide lamp Memory butt on Weekly average button ST ART/ST OP butto n Up/Down buttons USE R ID se le c tio n sw it ch Date/T ime setting button Blood pressure colou r indicator Air jack Battery compartment AC adapter jack (for optional AC adapter) Arm cuff Arm cuff (Arm ci rcumference 22-42cm) Air plu ...

  • Omron M6 Comfort - page 10

    5 1. Know Your De vice EN Display Symbols Irregular Heartbea t Symbol ( ) When the monit or detects an irregular rh ythm two or more times during t he measurement, t he irregular heartbeat s ymbol ( ) will appear on the display with the measurement values. An irregular heartbeat rhy thm is defined as a rhythm that is 25% less or 25% more than the a ...

  • Omron M6 Comfort - page 11

    6 1. Know Your De vice Blood Pressure Colour Indicator If your systolic or diastolic pressure is above the standard range (135 mmHg for the systolic blood pr essure and/or 85 mmHg for t he diastolic blood pres sure), the blood pressure colour indicator will light in “orange” when the measurem ent result is displayed . If they are within the s t ...

  • Omron M6 Comfort - page 12

    7 EN 2. Prep aration 2.1 Battery Inst allation 1. Remove the battery cover . 2. Insert 4 “AA” batteries as indicated in the battery comp artment. 3. Replace the battery cover . Not es: • When the low battery sy mbol ( ) appears on the display , turn the monito r off, then replace all batteries at the same time. Long life alkali ne batteries a ...

  • Omron M6 Comfort - page 13

    8 2. Prep aratio n 2.2 Setting the Date and T i me Set th e m o n itor to the co rrec t d a te a nd tim e b e fore t akin g a m e asure me nt for th e first time. 1. Press the Date/T ime setting ( ) button . The year flashes o n the Date/Time displ ay . 2. Push or button to change the year . Push b utton to confirm the year and then the mo nth fla ...

  • Omron M6 Comfort - page 14

    9 EN 3. Using the Device 3.1 Appl ying th e Arm Cuff Remo ve tight- fitting c lothing o r tight r olled up sleeve f rom your l eft upper arm. Do no t place th e arm cu ff over thick c lothes. 1. Insert the air plug in to th e a ir jac k securely . 2. Apply the arm cuff to your left upper arm. The bo ttom ed ge of the ar m cuff should be 1 to 2 cm a ...

  • Omron M6 Comfort - page 15

    10 3. Using the Device 3.2 How to Sit Correctly T o take a meas urement , you need to be rel axed and c omfortably seated, u nder comfor table room t emperature. Avoid bathin g, drink ing alco hol or c affeine, smok ing, exerci sing or eating 30 minutes before taking a meas urement. • Sit on a chair with your f eet flat on the f loor . • Sit up ...

  • Omron M6 Comfort - page 16

    11 3. Using the Device EN 3.3 T aking a Measurement Not es: • T o cancel a measureme nt , press the ST ART /ST OP bu tton t o release th e air in th e arm cuf f. • Remain still while t a king a m easurem ent . The moni tor is design ed to take measurem ents and store the meas urement va lues in the m emory for 2 people u sing USER ID 1 and US E ...

  • Omron M6 Comfort - page 17

    12 3. Using the Device 3. Remove the arm cuff. 4. Press the ST ART/STOP but ton to turn the monitor off. The m onitor au tomatical ly stores the me asurement r esult i n its memory . It will automat ically turn off after 2 minut es. Note: W ait 2-3 minutes before taking another measurement. W aiting between measurements allows the arteries to retur ...

  • Omron M6 Comfort - page 18

    13 3. Using the Device EN 3.4 Using the Memo ry Function The m onitor au tomatical ly stores the resul ts up to 100 se ts for each user (1 an d 2). It can als o calc ulate an averag e value base d on the las t 3 m easurem ent valu es taken within 10 minu tes . Not es: • If there are only 2 measurement values in the memory for that period, the ave ...

  • Omron M6 Comfort - page 19

    14 3. Using the Device T o V iew the Ave rage V a lue 1. Select your US ER ID (1 or 2). 2. Press and hold the button for mo re than 3 seconds. Not es: • If the previous measurement was taken without setting the date and t ime, the average value is not calculated. • If there are no measurement values stored in the memory , the screen to the righ ...

  • Omron M6 Comfort - page 20

    15 3. Using the Device EN T o V iew the W eekly Average V alue The m onitor c alculate s and dis plays weekly a verages for the m easurem ents taken in the m orning and e vening wi thin 8 wee ks for e ach user . Note: The week begins Sunday at 2 :00. 1. Select your US ER ID (1 or 2). 2. Press the button. The m ornin g averag e for “T HIS WEE K” ...

  • Omron M6 Comfort - page 21

    16 3. Using the Device Note: If there are no measurement values stored in the memor y , th e screen to the r ight is displayed. Morning W eekly A verage This is the av erage for the measurements taken during t he morning (4:00 - 1 1:59) between Sun day and Saturday . An average f or each day is calculated for up to t hree measurements taken within ...

  • Omron M6 Comfort - page 22

    17 3. Using the Device EN T o Delete All the V alues S tored in Memory The val ues stor ed in the m emor y are delete d by U SER ID. 1. Select your US ER ID (1 or 2). 2. Press the Memory button, while the memory symbol ( ) appears. 3. Whil e holding the button down, press the ST ART/STOP button for more than 3 se conds. Note: Y ou cannot partially ...

  • Omron M6 Comfort - page 23

    18 4. Error Messages and T roub leshooting 4.1 Error Mess ages Display Cause Solution Irregular heartbeats are detected. Remove the arm cuff. W ait 2-3 minutes and then t ake another measureme nt. Repeat the steps in section 3.3. I f this error continues to appear , contact your physician. Movement durin g measurement. Carefully read and repeat the ...

  • Omron M6 Comfort - page 24

    19 4. Error Message s and Troubleshoo ting EN Air plug is disconnected. Inse rt the air plug securely . Refer to section 3.1. Arm cuff is applied too loos ely . Apply the arm cuff tighter . Refer to section 3.1. Air is leaking from the arm cuff . Replace the arm cuff wit h a new one. Refer to section 5.3. Movement during measurement and the arm cuf ...

  • Omron M6 Comfort - page 25

    20 4. Error Message s and Troubleshoo ting 4.2 T roubles hooting Proble m Cause S olutio n The measurement resu lt is extremely high (or low). Arm cuff is applied t oo loosely . Apply the arm cuff tighter . Refer to section 3.1 . Movement or talking during measurement. Rem ain still and do not talk during measurement. Refer to section 3.3 . Clothin ...

  • Omron M6 Comfort - page 26

    21 4. Error Message s and Troubleshoo ting EN Nothing happens when you pres s the buttons. The batteries are empty . Replace the batteries with new ones. Refer to section 2.1 . The batteries have been inserted incorrectly . Insert t he batt eries with t he correc t (+/-) polarity . Refer to section 2.1 . Other problems. • Press the S T ART/STOP b ...

  • Omron M6 Comfort - page 27

    22 5. Maintenance and S torage 5.1 Maintenance T o protec t your dev ice fro m damage, p lease obs erve th e followi ng: • S t ore the de vice and the c omponents in a clean, safe location. • Do not use any abr asive or volatile cle aners. • Do not wash the device and any components or immerse them in water . • Do not use petrol, thinners o ...

  • Omron M6 Comfort - page 28

    23 5. Mai ntenance and Stor age EN 5.2 St or a g e Keep th e device in its s torage c ase when n ot in use. 1. Unplug the air plug fr om the air jack. 2. Gently fold the air tube into the arm cuff. Note: Do not bend or crease the air tube excess ively . 3. Place the moni tor and the arm cuff in the storage case. Do no t store th e devic e in the fo ...

  • Omron M6 Comfort - page 29

    24 5. Mai ntenance and Stor age 5.3 Optional Medical Accessories (withi n the sc ope of EC Medical De vice Direct ive 93/42/E EC) Arm c uff Arm cir cumferenc e 22-42 c m AC a d a pter Intelli Cuf f L-991 1730-8 (Model: HEM-F L31) Adapter S-9515336-9 Adapter UK-9983666-5 ...

  • Omron M6 Comfort - page 30

    25 5. Mai ntenance and Stor age EN Using the Optional AC A dapter 1. Insert the AC ada pter plug into the AC adapter jack on the rear side of the monitor . 2. Plug the AC adapter into an electrical outlet. T o disc onnect the AC ada pter , unplu g the AC adapter f rom the el ectric al outlet first and then remo ve the AC a dapter pl ug from th e mo ...

  • Omron M6 Comfort - page 31

    26 6. S pecifications Prod uct des cript ion Automatic B lood Pre ssure Mon itor Model OM RON M6 Comfort (HEM-7321-E) Display LCD digi tal dis play Meas ure ment me th od Oscillometric method Meas ure ment ra ng e Pre ssure: 0 to 299 mm Hg Pulse: 40 to 180 be ats / min. Accuracy Pressure: ± 3m m H g Pulse: ± 5% of display r eading Inflatio n Fuzz ...

  • Omron M6 Comfort - page 32

    27 6. Sp ecificat ions EN Not es: • These s pecifications are subject t o change without not ice. • In the clinical validation st udy , the 5t h phase was used on 85 subject s for determination of diastolic blood pressure. • This device has not been validated f or use on pregnant patients. • This device fulfil s the p rovision s of E C dire ...

  • Omron M6 Comfort - page 33

    28 6. Sp ecificat ions Import ant informa tion regarding Ele ctro Magneti c Compati bility (EMC) With the increased number of electronic dev ices such as PC’s and mobile (cellular) t elephones, medical devic es in use may be suscep tible to electromagnetic interference from ot her devices. Electrom agnetic interference may result in incorrect ope ...

  • Omron M6 Comfort - page 34

    29 EN 7. Wa r r a n t y Thank you for buying an OMRON product. This product is constructed of high quality materials and great care has been taken in its manufacturing. It is designed to give you every satisfaction, prov ided that it is properly operated and maintained as described in the instruction manual. This product is guaranteed by O MRON for ...

  • Omron M6 Comfort - page 35

    30 8. Som e Useful Inform a tio n a bout Bloo d Press ure What is Blood Pressure? Blood pres sure i s a meas ure of the force of blood flowing against the wall s of the a rteries . Arterial blood pr essure is constantly changi ng durin g the cour se of the heart’s cycle. The hig hest pre ssure in t he cycle i s calle d the Systoli c Blood Pressur ...

  • Omron M6 Comfort - page 36

    Manufacturer EU-representative OMRON HEAL THCARE EUROPE B.V . Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www .omron-healthcare.com Production facility Üretim T esisi Site de production Produktionsstätte Stabilimento di produzione Planta de producción Productiefaciliteit ɉɪɨɢɡɜɨɞ ɫɬɜɟɧɧɨɟɩɨɞɪɚɡɞɟɥɟɧɢɟ OMRON HE ...

Manufacturer Omron Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Omron M6 Comfort can be divided into several groups. They are, among others:
- Omron technical drawings
- M6 Comfort manuals
- Omron product data sheets
- information booklets
- or energy labels Omron M6 Comfort
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron M6 Comfort.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron M6 Comfort, service manual, brief instructions and user manuals Omron M6 Comfort. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron M6 Comfort.

A complete manual for the device Omron M6 Comfort, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron M6 Comfort by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron M6 Comfort.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron M6 Comfort - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron M6 Comfort, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron M6 Comfort, that we can find in the current document
3. Tips how to use the basic functions of the device Omron M6 Comfort - which should help us in our first steps of using Omron M6 Comfort
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron M6 Comfort
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron M6 Comfort in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron M6 Comfort?

Use the form below

If you did not solve your problem by using a manual Omron M6 Comfort, ask a question using the form below. If a user had a similar problem with Omron M6 Comfort it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)