  • Heat Controller SMA 12 - page 1

    Heat Controller , Inc. • 1900 Wellworth A ve. • Jackson, MI 49203 • (517)787-2100 • www .heatcontroller .com INST ALLA TION INSTR UCTIONS SMA/SMH 09/12 V ersion C Single Zone Ductless Mini-Split System A/C and Heat Pump ...

  • Heat Controller SMA 12 - page 2

    SMA/SMH 09/12 INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 1 Installation Manual for Single Zone Ductless Mini-Split • For correct installation, read this manual before starting the installation. Please save this manual in a safe place. • Only trained and qualied service personnel should install, repair or service air conditioning equ ...

  • Heat Controller SMA 12 - page 3

    Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 09/12 2 Part No. Name of Part Quantity 1 Installation Plate 1 2 Mounting Screw A (ST3.9x25-C-H) 8 3 Anchor 8 4 Refrigerant Pipe Liquid side o 1/4" Gas Side o 3/8" (<12,000 Btu/h) o 1/2" (≥12,000 Btu/h) 5 Remote Controller 1 6 Seal* 1 7 Drain Elbow* 1 Installation Parts ...

  • Heat Controller SMA 12 - page 4

    SMA/SMH 09/12 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 3 INDOOR UNIT INST ALLA TION 1. Mounting Installation Plate and Creating a W all Opening Installation Plate and measurements (inches): 2. Creating a wall opening 1. Attach the installation plate Clearance: Clearance: Clearance: Clearance: Clearance: Clearance: A. B. C. A. B. ...

  • Heat Controller SMA 12 - page 5

    Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 09/12 4 2. Line Set and Condensate Drain Line B. When extending the drain hose, insulate appropriately . 1. Condenstate Drain 2. Line Set • Connect the indoor unit rst, then the outdoor unit. Bend and arrange the piping carefully . • Do not allow the piping to loosen from the indoo ...

  • Heat Controller SMA 12 - page 6

    SMA/SMH 09/12 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 5 3. Indoor Unit Installation Place the upper lip at the back of the indoor unit onto the up - per hook of the installation plate. Move the indoor unit from side to side to see that is is secured onto the hook of the installation plate. Push the lower part of the indoor unit up to t ...

  • Heat Controller SMA 12 - page 7

    Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 09/12 6 5. Connecting Cables A. Indoor/outdoor connections should be 18 AWG or heavier , SJOW cord. Check the rating plate for minimum circuit to select wire size. B. Open the panel, remove the electrical box cover by loosening the screw for (for <12000Btu/h models). Remove the panel a ...

  • Heat Controller SMA 12 - page 8

    SMA/SMH 09/12 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 7 6. Piping and W rapping A. For the left-hand and right-hand piping, remove the rear plate bushing from the left side of the rear plate. B. Wind the line set, drain hose and wiring with tape se - curely and evenly . Consult local and national electrical codes for proper routing and ...

  • Heat Controller SMA 12 - page 9

    Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 09/12 8 OUTDOOR UNIT INST ALLA TION 1. Outdoor Installation Precaution • Install the outdoor unit on a rigid base to prevent noise and vibration. • Locate the air outlet direction where the discharged air is not blocked. Ensure there are no obstacles blocking the unit’s air ow . ...

  • Heat Controller SMA 12 - page 10

    SMA/SMH 09/12 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 9 1. Flaring 2. Tightening Connection 3. Refrigerant Piping Connection .04 A. B. A. B. Excessive torque can break the are nut. Ensure the proper torque is adhered to in the chart below . Hand tighten the are nut and then tighten it with a spanner and torque wrench as shown. ...

  • Heat Controller SMA 12 - page 11

    Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 09/12 10 4. Wiring Connection • • • • • • • Use a dedicated circuit. Use HACR break sized per unit’s rating plate. Size wires according to minimum circuit ampacity shown on the unit’s rating plate. • Be sure to comply with local and national electri - cal codes while r ...

  • Heat Controller SMA 12 - page 12

    SMA/SMH 09/12 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 1 1 AIR PURGE AND TEST OPERA TION 1. Air Purge where L=Length • Open the valve stem until it hits against the stop. Do not try to open it further . • Securely tighten the valve stem cap with a spanner or wrench. • T orque the valve properly: Gas pipe side (0.38"): 23.5 N- ...

  • Heat Controller SMA 12 - page 13

    2. Gas Leak Check 3. T est Operation soapy water . Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 09/12 12 Make sure connections do not leak with leak detector or soapy water . A. Lo packed valve B. Hi packed valve C. End of indoor unit connection D. End of indoor unit connection T est the unit’s operation after completing gas leak ...

  • Heat Controller SMA 12 - page 14

    04/2009 08/2010 ...

Manufacturer Heat Controller Category Heat Pump

Documents that we receive from a manufacturer of a Heat Controller SMA 12 can be divided into several groups. They are, among others:
- Heat Controller technical drawings
- SMA 12 manuals
- Heat Controller product data sheets
- information booklets
- or energy labels Heat Controller SMA 12
All of them are important, but the most important information from the point of view of use of the device are in the user manual Heat Controller SMA 12.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Heat Controller SMA 12, service manual, brief instructions and user manuals Heat Controller SMA 12. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Heat Controller SMA 12.

A complete manual for the device Heat Controller SMA 12, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Heat Controller SMA 12 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Heat Controller SMA 12.

A complete Heat Controller manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Heat Controller SMA 12 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Heat Controller SMA 12, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Heat Controller SMA 12, that we can find in the current document
3. Tips how to use the basic functions of the device Heat Controller SMA 12 - which should help us in our first steps of using Heat Controller SMA 12
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Heat Controller SMA 12
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Heat Controller SMA 12 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Heat Controller SMA 12?

Use the form below

If you did not solve your problem by using a manual Heat Controller SMA 12, ask a question using the form below. If a user had a similar problem with Heat Controller SMA 12 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)