Manual Wells WFGA-60FS

28 pages 2.19 mb
Download

Go to site of 28

Summary
  • Wells WFGA-60FS - page 1

    IMPORT ANT : WE LLS MA NUF ACTURI NG PROPRIET ARY I NFORMA TION. DISSEMINA TION OF THIS INFORM A TION T O ANYONE OTHE R TH AN WELLS AUTH ORIZED SERVICE AGENTS IS STRICT L Y PROHI BITED. TECH NICA L CON TEN T OF THIS MAN UAL IS DE SIGNED FO R US E BY QUALIFI ED PROF ESSION AL T ECHNICI ANS O N L Y . WELLS MANUF ACTURING COMP ANY 2 ERIK CIRC LE, P . ...

  • Wells WFGA-60FS - page 2

    xi SAFETY PROCEDURES Knowledge of proper procedures is essential to the safe operation of electrically energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols are used throughout this manual. DANGER W ARNING - Warning is used to indicate the presence ...

  • Wells WFGA-60FS - page 3

    T ABLE OF CONTENTS GENERAL SPECIFICA TIONS 1 DIMENSIONS Wide 18-3/16”” Deep 38-1/4” High (Basket Raised) 47-7/16” CAP ACITIES Lb. Kg . Cooking Oil (Liquid Shortening Only) 60 27 Chicken (fresh) (S t andard Basket) 30 13 Chicken (frozen) (S tandard Basket) 25 1 1 ELECTRICAL V oltage Requirement 120 V AC / 5 Amp 1 ∅ operation ONL Y GAS Natu ...

  • Wells WFGA-60FS - page 4

    2 1. POWER SWITCH FR YER position turns ON the FRYER and energizes the UPPER ( FR YER / OFF / FIL TER ) CONTROL P ANEL; and, turns OFF the FIL TER PUMP. Burner circuits are energized and regulate to the programmed temperature. OFF position turns OFF the FRYER. FIL TER position energizes the FIL TER PUMP . 2. TIME KEY Used to check and set menu time ...

  • Wells WFGA-60FS - page 5

    3 10. SONALER T Audible alarm to signal end of a cook cycle and other programmed functions. 1 1. LIFT CRADLE Raises and lowers FRY BASKET . 12. FR Y BASKET Sit s on the LIFT CRADLE and holds product to be cooked. Raised and lowered by the LIFT CRADLE. 13. OIL FIL TER RESERVOIR Holds the filter element. Holds oil during filtering cycle. 14. EXHAUST ...

  • Wells WFGA-60FS - page 6

    FRONT VIE W BACK VIEW KE EP THIS AR EA CL EAR 14. EXHA UST GAS FL UE 16. COOLING SLOT 23. DA T A P LA TE LI FT MOTOR ACCESS 23. GAS CONNECTION 22. ELECTRI CAL CONNECTION UPPER CONT ROL P ANEL LOWER CONTROL P A NEL FRONT ACCESS DOOR BURNER A SSEMBLIES GAS V A L VES FRYPOT 4 EQUIPMENT INST ALLA TION AND SET -UP A. INITIAL INST ALLA TION 1. A single W ...

  • Wells WFGA-60FS - page 7

    5 B. ELECTRICAL INST ALLA TION 1. The fryer is equipped with a three-prong grounding plug (NEMA 15-5P) for your protection against shock hazard. The fryer must be plugged directly into a properly grounded three-prong receptacle (NEMA 15-5R). 2 . The installation of this fryer must conform to local codes. In the absence of local codes, the installat ...

  • Wells WFGA-60FS - page 8

    6 C. GAS PLUMBING INST ALLA TION AND SET -UP 1 . The installation of this fryer must conform to local codes. In the absence of local codes, the installation of this fryer must conform with the National Fuel Gas Code (ANSI Z223.1). In Canada, the National Gas Installation Code (CAN/CGAB149.2) is applicable. 2 . The fryer must be isolated from munici ...

  • Wells WFGA-60FS - page 9

    D. NA TURAL GAS / LP GAS (PROP ANE) CONVERSION 1. This fryer is orificed at the factory for natural gas at a pressure of 3.5” of water column. The installed orifice is suit able for use at -280 to 2999 feet (-85 to 914 meters) elevation. It is the responsibility of the installer to inst all the factory recommended orifice and pressure regulator k ...

  • Wells WFGA-60FS - page 10

    8 OPERA TION A. HEA TING INSTRUCTIONS IMPORT ANT : Never press the POWER SWITCH to FR YER unless the frypot is filled with shortening. Check shortening level marker inside the frypot for proper shortening level. NOTE: The fryer is designed to be used with LIQUID SHORTENING only . Lard and solid shortening will solidify in the filter pump, causing p ...

  • Wells WFGA-60FS - page 11

    TROUBLESHOOTING OPERA TIONAL PROBLEMS NOTE: The fryer has two independent burner systems, whose only common components are in the control system (CONTROLLER, TEMPERA TURE PROBE and HI-LIMIT THERMOST A T). T roubleshooting ef forts should isolate a problem to either: an individual burner system; or , to the control system. PROBLEM POSSIBLE CAUSE SOL ...

  • Wells WFGA-60FS - page 12

    10 OIL FIL TERING INSTRUCTIONS DANGER OIL MUST BE FIL TERED WHILE HOT (300ºF AND HIGHER) Contact with hot oil can cause serious injury including death. Always wear protective clothing and insulated gloves when filtering the cooking oil. 1. Refer to the Installation, Operation and Maintenance Manual (p/n 300007) for complete operating instructions ...

  • Wells WFGA-60FS - page 13

    11 TROUBLE SHOOTING - OIL FIL TERING PROBLEMS PROBLEM POSSIBLE CAUSE SOLUTION FIL TER PUMP won’t POWER SWITCH not in Press POWER SWITCH to run FIL TER position FIL TER position PUMP MOT OR OVERLOAD Allow motor to cool, then tripped press red RESET button on back of PUMP MOT OR Defective POWER SWITCH Replace SWITCH PUMP will not pump SUCTION TUBE ...

  • Wells WFGA-60FS - page 14

    12 SER VICING INSTRUCTIONS GAS DISTRIBUTION AND BURNER SYSTEM 8 27 43 44 6 6 14 14 35 35 12 12 97 97 60 60 11 11 92 92 92 92 61 61 42 42 90 90 46 46 93 45 45 62 87 63 63 a a ...

  • Wells WFGA-60FS - page 15

    13 ITEM DESCRIPTION SE R VICE P ART NO. 6 W ASHER, ORIFICE 8 BURNER ASSY , LEFT 500781 1 1 COMBINA TION GAS V AL VE 500784 1 2 TUBE, GAS 500802 1 4 ORIFICE, GAS BURNER NA TURAL GAS, BELOW 3000 FT (2 EA, KIT) 502140 NA TURAL GAS, 3000 - 5999 FT (2 EA, KIT) 502141 NA TURAL GAS, 6000 - 8999 FT (2 EA, KIT) 502142 NA TURAL GAS, ABOVE 9000 FT (2 EA, KIT) ...

  • Wells WFGA-60FS - page 16

    BURNER ASSEMBL Y INSTRUCTIONS A. ORIFICE INST ALLA TION 1. Slide the brass ORIFICE through the ring on the end of the BURNER, threaded end pointing out. 2. Slide the ORIFICE W ASHER over the threads of the ORIFICE. 3. Screw the ORIFICE HOLDER on to the ORIFICE. T ighten the orifice holder so that the compression fitting sits pointing toward the out ...

  • Wells WFGA-60FS - page 17

    E. BURNER INST ALLA TION 1. Insert each BURNER TUBE through its respective mounting plate. 2. CAREFULL Y reach inside the unit, just above the filter pump heat shield, to guide the rear mounting tab of the burner tube into the slot in the rear mounting bracket. 3. Slide the the burner assembly over the front mounting studs, thread on nuts and tight ...

  • Wells WFGA-60FS - page 18

    CRADLE LIFT ASSEMBL Y ITEM DESCRIPTION SE R VICE P ART NO. 1 BEARING , ROLLER .75OD x .25ID (pk6) 500031 2 CRADLE PIVOT ASSEMBL Y 4 ROD, LIFT 5 BASKET , FRYER 22441 3 4 ACTUA TOR, LIFT 69812 7 1 CLAMP , PLASTIC 3/8” DIA. 8 2 YOKE, ROD LIFT 8 3 BASKET CRADLE LIFT ASSEMBL Y 8 4 BUSHING , LIFT ROD 69972 J NUT , ACORN 1/4-20 SS K BOL T , HEX 1/4-20 x ...

  • Wells WFGA-60FS - page 19

    LIFT MOTOR / LIFT ROD ASSEMBL Y INSTRUCTIONS A. LIFT ROD BUSHING 1. The top bushing assembles through the T OP P ANEL and FRAME. The W A VE W ASHER and JAM NUT go BELOW top part of frame. 2. The bottom bushing assembles through the top hole in the FRAME BACK P ANEL. B. LIFT MOTOR 1. Apply volt age to the BLACK and WHITE wires of the motor until the ...

  • Wells WFGA-60FS - page 20

    ITEM DESCRIPTION SE R VICE P ART NO. 9 IGNITION CONTROL, DIRECT SP ARK 500782 10 TRANSFORMER, 120V - 240V 500783 13 P ANEL, UPPER CONTROL 18 CONTROLLER, RED LED's 500830 30 THERMOWELL, HI-LIMIT 50 1 15 8 31 "J" THERMOCOUPLE 50 1 199 32 TRANSFORMER, CONTROLLER 120V - 24V 501201 68 THERMOST A T , HI-LIMIT 502469 79 SWITCH, POWER FR YER ...

  • Wells WFGA-60FS - page 21

    ELECTRICAL COMPONENTS INST ALLA TION INSTRUCTIONS A. HI-LIMIT THERMOST A T 1. Install THERMOWELL in lower threaded hole in frypot. Use hi-temperature pipe thread compound. 2. Insert HI-LIMIT THERMOST A T thermobulb into THERMOWELL. DO NOT use any type of pipe thread compound or tape. Thread the compression fitting into THERMOWELL and tighten finger ...

  • Wells WFGA-60FS - page 22

    ITEM DESCRIPTION SE R VICE P ART NO. 3 3 MOTOR, FIL TER PUMP 501205 3 6 PUMP , FIL TER PUMP 501231 4 7 BRACKET , HEA T SHIELD 5 7 W ASHER, FIBER 5 8 CONDUIT FITTING , 90º 6 7 ADAPTER, I/2" FPT x 15/16M FLARE 6 9 CHECK V AL VE 66692 7 0 SUCTION LINE FITTING 66720 7 3 UNION, 3/8" NPT 7 4 ELBOW , 3/8" NPT 90º 7 5 REDUCER, 1/2" NP ...

  • Wells WFGA-60FS - page 23

    FIL TER PUMP / MOT OR ASSEMBL Y INSTRUCTIONS CAUTION: New style motor is a dual voltage rated unit, and must be field wired to match the electrical service supply voltage. Motor may be shipped wired for either 230V or 125V . V erify the supply volt age and the motor volt age configuration. If necessary , rewire motor , at the terminal block in the ...

  • Wells WFGA-60FS - page 24

    22 WF AE-60FS P ARTS BREAKDOWN (GENERAL REFERENCE ONL Y) ITEM DESCRIPTION 1 BEARING , ROLLER, .75 x .25 2 CRADLE PIVOT ASSY 3 P ANEL, TOP 4 LIFT ROD 5 BASKET , FR YER 6 WASHER, ORIFICE 7 HOUSING , LIFT MOTOR 8 BURNER ASSY , LEFT 9 IGNITION CONTROL 10 TRANSFORMER, IGNITION 1 1 GAS CONTROL V AL VE 12 TUBE, GAS V AL VE 13 CONTROL P ANEL, UPPER 15 FRAM ...

  • Wells WFGA-60FS - page 25

    23 WF AE-60FS P ARTS BREAKDOWN (GENERAL REFERENCE ONL Y) ...

  • Wells WFGA-60FS - page 26

    24 WFGA-60FS WIRING DIAGRAM / SCHEMA TIC ...

  • Wells WFGA-60FS - page 27

    SERVICE P ARTS LIST IMPORT ANT : Use only factory authorized service part s and replacement filters. For a complete listing of service parts for this fryer , consult Service Parts List AS007 . FR YER ACCESSORIES P ART# FLA VOR SA VER OIL FIL TER POWDER (45 pk) 22410 BASKET , FULL SIZE 22441 W AOC-1 MOBILE OIL DISPOSAL CADDY 22470 P ADDLE, STIRRING ...

  • Wells WFGA-60FS - page 28

    WELLS M ANUF ACT URING COMP ANY 2 ERIK CIRCLE, P . O. Box 280 V erdi, N V 8943 9 Servi ce Part s D ep t. (888) 49 2-2782 fax: (888) 492- 2783 w service @ ells bloomfie ld.c om IMPORT ANT : WELLS MANUF A CTURING PROPRIET A RY INFORM A T ION. DISSEMINA TION OF THIS INFORMA TION T O ANYONE OTHER THAN WELLS AUT HORIZE D SERVIC E AG ENTS I S STRIC TL Y ...

Manufacturer Wells Category Fryer

Documents that we receive from a manufacturer of a Wells WFGA-60FS can be divided into several groups. They are, among others:
- Wells technical drawings
- WFGA-60FS manuals
- Wells product data sheets
- information booklets
- or energy labels Wells WFGA-60FS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Wells WFGA-60FS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Wells WFGA-60FS, service manual, brief instructions and user manuals Wells WFGA-60FS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Wells WFGA-60FS.

Similar manuals

A complete manual for the device Wells WFGA-60FS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Wells WFGA-60FS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Wells WFGA-60FS.

A complete Wells manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Wells WFGA-60FS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Wells WFGA-60FS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Wells WFGA-60FS, that we can find in the current document
3. Tips how to use the basic functions of the device Wells WFGA-60FS - which should help us in our first steps of using Wells WFGA-60FS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Wells WFGA-60FS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Wells WFGA-60FS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Wells WFGA-60FS?

Use the form below

If you did not solve your problem by using a manual Wells WFGA-60FS, ask a question using the form below. If a user had a similar problem with Wells WFGA-60FS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)