Manual Windsor E50 10070090

26 pages 0.51 mb
Download

Go to site of 26

Summary
  • Windsor E50 10070090 - page 1

    Read these instructions bef ore operating the machine MOD EL: E50 10070090 86038250 02/12/07 PRV NO. 98635 V CARPET EXTRACTOR Operating Instru ctions (ENG ) ...

  • Windsor E50 10070090 - page 2

    MACHINE DATA LOG/OVERVIEW ENSIGN 86038250 02/12/07 2 For the name and address of your dealer contact: Windsor Industries YOUR DEALER Name: ____________________ __________________________ __________________________ __________________________ Address: __________________ __________________________ __________________________ _________________________ P ...

  • Windsor E50 10070090 - page 3

    TABLE OF CONTENTS ENSIGN 86038250 02/12/07 3 Machine Data Log/Overview. ........................ 1 Table of Contents .......................................... 2 HOW TO USE THIS MANUAL How to use this Manual. ................................ 1-1 SAFETY Important Safety Instructions ........................ 2-1 Hazard Intensity Level. .............. ...

  • Windsor E50 10070090 - page 4

    HOW TO USE THIS MANUAL ENSIGN 86038250 02/12/07 1-1 This manual contains the f ollowin g sections: - HOW TO USE THIS MANUAL - SAFETY - OPERATIONS - MAINTENANCE - PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts. Parts may be ordered from authori zed Windsor dealers. When ...

  • Windsor E50 10070090 - page 5

    SAFETY INSTRUCTIONS ENSIGN 86038250 02/12/07 2-1 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Connect to a properly ground ...

  • Windsor E50 10070090 - page 6

    HAZARD INTENSITY LEVEL ENSIGN 86038250 02/12/07 2-2 The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard in tensity identified by signal words - WARNI NG and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: WA ...

  • Windsor E50 10070090 - page 7

    SAFETY LABEL LOCATION ENSIGN 86038250 02/12/07 2-3 NOTE: These drawings indicate the lo cation of safety labels on the machine. If at any tim e the labels become illegible, promptly replace them. LABEL WARNING 86242230 PRV NO. 500009 ...

  • Windsor E50 10070090 - page 8

    GROUNDING INSTRUCTIONS ENSIGN 86038250 02/12/07 2-4 THIS PRODUCT IS FOR C OMMERCIAL USE ONLY. ELECTRICAL: In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause s ...

  • Windsor E50 10070090 - page 9

    TECHNICAL SPECIFICATIONS ENSIGN 86038250 02/12/07 3-1 ITEM MEASURE Electrical 115 Volt, 60hz Vacuum Motor Single 3 stage Solution Pump 50 psi Solution Capacity 7 gal (26 L) Recovery Capacity 6 gal (22 L) Weight - Empty 50 lbs (110 kg) Weight –Full Solution 105 lbs (230 kg) Height 35 inches (88.90 cm) Height – (Handle Folded Down) 28.5 inches (7 ...

  • Windsor E50 10070090 - page 10

    CONTROLS ENSIGN 86038250 02/12/07 3-2 1. Vacuum Switch 2. Pump Switch ON OFF OFF ON VAC PUMP 1 2 ...

  • Windsor E50 10070090 - page 11

    MACHINE OPERATION ENSIGN 86038250 02/12/07 3-3 GENERAL INFORMATION As the carpet is being cleaned, check to see if there is foam building up in the recovery bucket. Add a little defoaming compound to the recovery tank but never to the solution tank. For infrequent use or long periods of storage , flush the system with a neutralizing solution of 1 q ...

  • Windsor E50 10070090 - page 12

    MAINTENANCE ENSIGN 86038250 02/12/07 4-1 Unplug power cord(s) before servicing or makin g an y repairs . DAILY MAINTENANCE 1. Flush the entire syst em, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water. 2. Vacuum out the solution tank. 3. Rinse tank with fr esh water. Periodically inspect the recovery t ank and decontam ...

  • Windsor E50 10070090 - page 13

    MAINTENANCE ENSIGN 86038250 02/12/07 4-2 Only qualified maintenance personnel are to perform the following repairs . VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Locate the vacuum motor wires and disconnect at the connector. 4. Remove the vacuum motor. 5. Reverse process to install vacuum motor. ...

  • Windsor E50 10070090 - page 14

    MAINTENANCE ENSIGN 86038250 02/12/07 4-3 Only qualified maintenance personnel are to perform the following repairs . SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove solution hoses from fittings in pump. 4. Remove the screws that fasten the pump to the frame. 5. Reverse process to install ...

  • Windsor E50 10070090 - page 15

    TROUBLESHOOTING ENSIGN 86038250 02/12/07 4-4 PROBLEM CAUSE SOLUTION Dead electrical circuit Check building circuit breaker or fuse box. Loss of Power Faulty power cord Replace Equipment not grounding Follow grounding instructions exa ctly Receptacle not grounded Contact an electri cian to check buil ding’s wiring Electrical shock Internal wiring ...

  • Windsor E50 10070090 - page 16

    PUMP GROUP ENSIGN 86038250 02/12/07 5-1 1 2 3 5 6 7 8 2 3 4 ...

  • Windsor E50 10070090 - page 17

    PUMP GROUP ENSIGN 86038250 02/12/07 5-2 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86280840 39049 1 HOSE, 3/8” RUBBER X 11’ 2 86233150 20042 2 CLAMP, 3/8 HOSE (D-SL OT) 3 86001550 4004 3 2 HOSEBARB, 3/8 MPT X 3/8 90 ° 4 86018050 65216 1 PUMP ASM, 115V 3ST SENSEI 5 86199960 110-22 4 GROMMET 6 GAL. PORT 6 86010630 87013 2 WASH ...

  • Windsor E50 10070090 - page 18

    RECOVERY TANK GROUP ENSIGN 86038250 02/12/07 5-3 3 4 5 6 9 10 11 12 14 16 17 18 20 21 22 23 24 13 15 26 15 1 27 7 8 19 2 32 25 28 29 30 31 ...

  • Windsor E50 10070090 - page 19

    RECOVERY TANK GROUP ENSIGN 86038250 02/12/07 5-4 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86227230 04094 1 ADPTR, 1.5FS X 1.5FS PVC “U” 2 86033210 34408 1 FLOAT SHUT-OFF TUBE W/ADPTR 3 86002620 260-64A 1 ACCESS COVER CLEAR 6” W/ RIM 4 86275800 70546 6 SCR, 8 X 3/4 PFHT/S BLK ZINC 5 86033350 38299 1 HANDLE, DK GRY 6 861993 ...

  • Windsor E50 10070090 - page 20

    SOLUTION TANK GROUP ENSIGN 86038250 02/12/07 5-5 * * PARTS INSIDE TANK CONNECT TO PUMP ASM 4 5 7 8 6 6 1 2 9 10 41 6 11 12 6 14 13 15 18 19 22 20 21 17 16 23 24 28 29 30 18 31 32 33 34 35 38 37 39 39 40 36 3 26 27 25 23 42 43 ...

  • Windsor E50 10070090 - page 21

    SOLUTION TANK GROUP ENSIGN 86038250 02/12/07 5-6 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86005580 56012 1 NIPPLE, 1/4FPT QD 2 86090230 87015 1 WASHER, 9/16 ID X 1.06 OD SS 3 86014060 86014060 1 TANK, SOLUTION SENSEI BLK 4 86199640 030-16 1 ELBOW, 1/4 NPT STREET LONG 90D 5 86197550 40014 1 HOSEBARB, 1/4MPT X 3/8 BRASS DL 6 8623 ...

  • Windsor E50 10070090 - page 22

    VACUUM MOTOR GROUP ENSIGN 86038250 02/12/07 5-7 3 1 2 4 5 ...

  • Windsor E50 10070090 - page 23

    VACUUM MOTOR GROUP ENSIGN 86038250 02/12/07 5-8 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86201950 065-24E 3 VAC SPACER 3 1/8 2 86010630 87013 3 WASHER, 1/4 ID X 5/8 OD SS 3 86273970 70062 3 SCR, 1/4-20 X 4 HHCS GR5 PLTD 4 86258420 53130 1 VAC MOTOR, 120V 5.7 3ST W/O TB * - 86135320 140687 - BRUSH SET,120V VAC WINDSOR * SERVICE ...

  • Windsor E50 10070090 - page 24

    WIRING DIAGRAM ENSIGN 86038250 02/12/07 5-9 ...

  • Windsor E50 10070090 - page 25

    SUGGESTED SPARE PARTS ENSIGN 86038250 02/12/07 5-10 PART NO. PRV NO. DESCRIPTION SERIAL NO. FROM NOTES: 86003680 34380 FLOAT SHUT OFF 86002620 260-64A ACCESS COVER CLEAR 6” W/RIM 86161470 11-800444 ELBOW, 1.5 FS X FS 45D PVC 86256960 72142 SWITCH SPST 15A EURO ROCKER 86202160 320-05 VELCRO STRAPS 86003720 35011 GASKET, 3/8T 5.7 VAC FAN SEAL 86200 ...

  • Windsor E50 10070090 - page 26

    NOTES ENSIGN 86038250 02/12/07 5-11 ...

Manufacturer Windsor Category Carpet Cleaner

Documents that we receive from a manufacturer of a Windsor E50 10070090 can be divided into several groups. They are, among others:
- Windsor technical drawings
- E50 10070090 manuals
- Windsor product data sheets
- information booklets
- or energy labels Windsor E50 10070090
All of them are important, but the most important information from the point of view of use of the device are in the user manual Windsor E50 10070090.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Windsor E50 10070090, service manual, brief instructions and user manuals Windsor E50 10070090. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Windsor E50 10070090.

Similar manuals

A complete manual for the device Windsor E50 10070090, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Windsor E50 10070090 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Windsor E50 10070090.

A complete Windsor manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Windsor E50 10070090 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Windsor E50 10070090, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Windsor E50 10070090, that we can find in the current document
3. Tips how to use the basic functions of the device Windsor E50 10070090 - which should help us in our first steps of using Windsor E50 10070090
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Windsor E50 10070090
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Windsor E50 10070090 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Windsor E50 10070090?

Use the form below

If you did not solve your problem by using a manual Windsor E50 10070090, ask a question using the form below. If a user had a similar problem with Windsor E50 10070090 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)