Manual SMC Networks VDSL2

96 pages 2.32 mb
Download

Go to site of 96

Summary
  • SMC Networks VDSL2 - page 1

    T igerAccess ™ EE 6-Band VDSL2 Switch ◆ 16 VDSL Downlink Ports (1 RJ-21 Co nnector) ◆ 2 Gigabit Ethernet Com bination Ports (RJ-45/SFP) ◆ 1 Fast Ethernet Managemen t Port (RJ-45) ◆ Non-blocking switching architecture ◆ Spanning T ree Protocol, RSTP , and M STP ◆ Up to 12 LACP or static 8-port t runks ◆ Layer 2/3/4 C oS support th ro ...

  • SMC Networks VDSL2 - page 2

    ...

  • SMC Networks VDSL2 - page 3

    20 Maso n Irvine, CA 9261 8 Phone: (9 49) 67 9-8000 T igerAccess ™ EE Installation Guide From SM C’ s T iger line of f eature-ri ch workgro up LAN solutions February 2007 Pub. # 14 9100012100H ...

  • SMC Networks VDSL2 - page 4

    Information fu rnished by SMC Netw orks, Inc. (SMC) is belie ved to be ac curate a nd reliab l e . Ho wev er , no respon sibility is assumed by SMC for it s use, nor for an y infring ements o f patents or ot her rights o f third par ties which may res ult fr om i ts use. No lice nse is g rant ed by im plica tion or ot herwi se un der an y pat ent o ...

  • SMC Networks VDSL2 - page 5

    v L IMITED W ARRANTY Limited W ar ranty Statement: SM C Networks, Inc. (“SMC” ) warrant s its pro ducts to b e free from defects in w orkmanship and materials , under nor mal use and ser vice, f or the applicable warranty term . All SMC products car ry a standard 90-day limited warranty from the date of purc hase from SMC or its Authorized R es ...

  • SMC Networks VDSL2 - page 6

    vi WARRA NTIES EXCLUSIV E: IF AN SMC PR ODUCT DOES NOT OPE RATE A S W ARRANTED ABO VE, CUSTOMER’S SOL E REMED Y SHALL BE R EP AIR OR REPLA CEMENT OF THE PRODUCT I N QUES TION , AT SMC’S OPTION . THE FOREGOING W ARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER W ARRANTIES OR CONDITIONS , EXPRESS OR IMPLIED , EITHER IN F ACT OR B ...

  • SMC Networks VDSL2 - page 7

    vii C OMPLIANCES FCC - C lass A This equipment has been tested and found to compl y with the limits for a Clas s A di gital device, pursuant to part 15 of the FCC Rules . Thes e limits are designed to provide r easonable protection against har mful interference when the equipment is operated in a commercial envir onment. This equ ipment generates , ...

  • SMC Networks VDSL2 - page 8

    C OMPLIANCES viii networ k until the probl em has been corrected or un til you are sure that the equ ipment is not malfunctioning . This equipment may not be used on coi n service provided by the telephone company . Connection to party lines is subject to state ta riffs . Industr y Canada - Class A This digital appar atus does not ex ceed the Class ...

  • SMC Networks VDSL2 - page 9

    C OMPLIANCES ix Wa r n i n g : Do not plug a phone jac k connector in th e RJ-45 port. This may damage this device. Attention: Les raccordeurs ne sont pas uti lisés pour le système téléphoniqu e! Safety Compliance W a rn i n g : F i b e r O pt i c P o rt S a f e t y A ve r tissme nt: Ports pour fibres optique s - sécur ité sur le plan opti qu ...

  • SMC Networks VDSL2 - page 10

    C OMPLIANCES x Pow e r C o r d S a fe t y Please re ad the followin g safety inf or mation c arefully be fore ins talling the s witch: Wa r n i n g : Installation and remo val of the unit must be carrie d out by qualified person nel only . • The unit must be connec ted to an earthed (grounded) outle t to comply with internat ional safety s tandar ...

  • SMC Networks VDSL2 - page 11

    C OMPLIANCES xi V euillez lire à fond l'infor mation de la sécurité sui vante av ant d'installer le Switch: A VERTISSEMENT : L’installat ion et la dépose de ce groupe doivent être confiés à un personnel qualifi é. • Ne branchez pas votre apparei l sur une prise s ecteur (alim entation élect rique) lorsqu' il n'y a p ...

  • SMC Networks VDSL2 - page 12

    C OMPLIANCES xii F rance et Pér ou uniqu ement: Ce groupe ne peut pas être alimenté par un disposi tif à impédance à la t erre. Si v os alimentations sont du type impédance à l a terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un transfor mateur d’isolem ent à rapport 1:1, avec un point secondaire ...

  • SMC Networks VDSL2 - page 13

    C OMPLIANCES xiii wenn auch die an d as Gerät angeschlossenen Geräte unter SELV-Bedingungen betrieben werden. W ar nings and Caut ionar y Mes sages Wa r n i n g s (in German) Stromkabel. Dies muss von d e m Land , in dem es benutzt wird geprüft werden: Schweiz Dieser Strom stecker muß die SEV/ASE 1011Best i mmungen einhalten. Europe Das Netzkab ...

  • SMC Networks VDSL2 - page 14

    C OMPLIANCES xiv En vironmental Statem ent The manufacturer of this product e ndeavour s to sustain an en vironmentally-friendly policy throughout the entire production proces s . This is ac hieved thou gh the follow ing means: • Adherence to national legis lation and regulations on environmental production standards . • Conservation of oper at ...

  • SMC Networks VDSL2 - page 15

    xv T ABLE OF C ONTENTS 1 About the TigerAccess EE Switch . . . . . . . . . . . . . . . 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 VDSL Techn ology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Switch Ar chitecture . . . . . . . . . . . . . . . . . ...

  • SMC Networks VDSL2 - page 16

    T ABLE OF C ONTENTS xvi Installing an Op tional SFP Transceiver . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 Connecting to a Power Sour ce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 Connecting to the Cons ole Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 Wiring Map for Serial Cable . . . . . ...

  • SMC Networks VDSL2 - page 17

    T ABLE OF C ONTENTS xvii A PPEN DICES : A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Diagnosing Sw itch Indicator s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Power and C ooling Proble ms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 Installat ion . . . . . . . ...

  • SMC Networks VDSL2 - page 18

    xviii T ABLES Table 1-1 Optiona l SFP Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Table 1-2 Port Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 Table 1-3 System Sta tus LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 Table 3-1 Optiona l SFP Transceivers . ...

  • SMC Networks VDSL2 - page 19

    xix F IGURES Figure 1-1 VDSL Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Figure 1-2 Front and Rear Panel s . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Figure 1-3 Port and System LED s . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 Figure 1-4 Power Supply Sock et . . . . . . . . . . . . . . ...

  • SMC Networks VDSL2 - page 20

    F IGU RES xx ...

  • SMC Networks VDSL2 - page 21

    1-1 C HAPTER 1 A BOUT THE T IGER A CCESS EE S WITCH Overview This Ethernet-ov er-V DSL system c onsists of end-us er CPEs (C ustomer Premise Equipment) conn ected to a VDSL swi tch by s tandard telephone cable . T he V DSL connec tion deliv ers an Ethe rnet data link wh ile simultane ously s uppor ting st andar d tele phone ser vices. T he syste m ...

  • SMC Networks VDSL2 - page 22

    A BOUT THE T IGE R A CCES S EE S WITCH 1-2 The VDSL switc h is typi cally located in a wiring closet or other cen tral location of a multi-dwelling/multi-tenant unit, campus or enterprise. An Internet c onnect ion is p rov ided fro m the IS P to th e custom er’ s buildin g ov er fiber op tic cable, running Ethernet di rectly ov er a 1 Gbps conn e ...

  • SMC Networks VDSL2 - page 23

    O VER VI EW 1-3 VDSL Technology VDSL2 (V er y High Bit-R ate Digital S ubscriber Line) is at t he high-end of all th e DSL tec hnologie s , offering t he be st combi nation of fi ber op tic and copper to pro vide high-spe ed broadb and Internet access . VD SL’ s pri mary application is in providing a bro adband data ser vice to multi-tenant resid ...

  • SMC Networks VDSL2 - page 24

    A BOUT THE T IGE R A CCES S EE S WITCH 1-4 VDSL can deliver high-perform ance online applications, such as high-quality video and other switched multimedia ser vices. This Ether ne t-ov er-VDSL syst em provide s robust pe rfor man ce, with a maximum symmetric data rate of 100 Mbps for ru ns up to 200 meters (656 ft). Th is system is based on adva n ...

  • SMC Networks VDSL2 - page 25

    D ESCRIPTION OF H ARDW AR E 1-5 conne ction (in- band) usin g T elnet, th e on-boar d web age nt, or SNMP-bas ed ne tw ork m anagement softw are. Th e manag ement port pr ovides a d edicate d manag ement channel that operate s outside of the data transpor t network. T his makes it po ssible to re-con figure or tr oubles hoot the switc h o ve r eith ...

  • SMC Networks VDSL2 - page 26

    A BOUT THE T IGE R A CCES S EE S WITCH 1-6 The follo wing figur e sho ws the compon ents o f the VD SL swit ch. Figure 1-2 Front and Rear Panels RJ-21 P orts The RJ -21 port s on the s witch front panel su ppor t 16 twisted -pair connec tions . The “Line” port connec ts to end -user CPE s thro ugh a punc h-down bo x. The “POTS” port connect ...

  • SMC Networks VDSL2 - page 27

    D ESCRIPTION OF H ARDW AR E 1-7 Eac h port als o supp or ts au to-negotiati on of flow con trol, s o th e swit ch can a utomat ically p rev ent po rt buffers from becomin g satur ated. Note: If an SFP tran sceiver (purc h ased sepa rately) is installed in a slot and has a va lid link on the port, th e asso ciated RJ-45 po rt is disa bled. SFP Slots ...

  • SMC Networks VDSL2 - page 28

    A BOUT THE T IGE R A CCES S EE S WITCH 1-8 Consol e Port The cons ole port on the sw itch’ s fron t panel is a DB -9 conn ector that enabl es a conn ection t o a t er mina l for per for ming sw itc h monit oring and config uration functio ns . The ter minal may be a PC or workstatio n r unning ter minal em ulation softw are, or a ter minal config ...

  • SMC Networks VDSL2 - page 29

    D ESCRIPTION OF H ARDW AR E 1-9 Table 1-2 Port Status LEDs LED Condition Status VDSL Ports Link/Act (Port 1-16) On Green Port has a val id link Flash ing Green Flashi ng indicates acti vity on the port Off The link is do wn, or port is disabl ed Uplink Ports Link/Act (Port 17-18) E: RJ-45 O: SF P On Green Port has a val id link Flash ing Green Flas ...

  • SMC Networks VDSL2 - page 30

    A BOUT THE T IGE R A CCES S EE S WITCH 1-10 Power Supply Socket Th ere is a power s ocket on the f ront pane l of the swi tch for a n A C power cord. Figure 1-4 Power Supply So cket Key Features VDSL Features • H igh-spee d Intern et acces s over ex isting p hone li nes • ITU-T G.993.1/G.993.2 VDSL & VDSL2 Standard and G.993.2 Annex.C Compl ...

  • SMC Networks VDSL2 - page 31

    K EY F EAT UR ES 1-11 • Robust operation on severely distorte d lines • Su pports powe r back-off algorithm that per mits a mixed distan ce deploy ment Addition al VDSL2 featu res includ e: • Fast startup for quick initialization • Trellis coding modulation for higher p erformanc e • Seaml ess rat e adapta tion for en ha nced quality in v ...

  • SMC Networks VDSL2 - page 32

    A BOUT THE T IGE R A CCES S EE S WITCH 1-12 Expandabi lity • Supports optional 1000BASE-SX, 1000BASE-LX and 1000BASE-ZX SFP transce i vers System F eatur es • T ranspar ent bridging • A ggrega te switch fa bric bandwi dth of 8 .8 Gbp s • Swi tchin g table w ith a t otal of 8 K en trie s • Store-and-forw ard switching • Wire-sp eed Layer ...

  • SMC Networks VDSL2 - page 33

    2-1 C HAPTER 2 N ETWORK P LANNING Introd uction t o Switc hing A network switch allows s imultaneous transmission of multiple packets via non-cros sbar switching . T his means that it ca n partit ion a netw ork more effici ently th an bridges or r outers . The switc h has, therefo re, b een recogniz ed as one of the most impor tant build ing blocks ...

  • SMC Networks VDSL2 - page 34

    N ETWORK P LANNING 2-2 Th is VDSL switch provides In ter net co nnecti ons of up to 100 Mb ps symmetric, o r an asy mmetric 100 Mbps do wnstream and 50 Mbps upstream ov er 200 meters . Cable dista nces also can run up to 1. 5 k m at lower transmission rates . Installation is extremely e conomical for mul tiple -tenant d wel ling s suc h as apartmen ...

  • SMC Networks VDSL2 - page 35

    A PPL ICAT ION E XAM PLES 2-3 Remote Connections with Fiber Cable Fiber op tic techn olog y allows for long er c abling tha n any o ther med ia type. A 1000BASE-SX MMF Gigabit link can connect to a site up to 550m aw ay , a 1000B ASE-LX (SMF) link up to 10 km, and a 1000B A SE-ZX link up to 70 km. T his allows end -users at two site s to use the sa ...

  • SMC Networks VDSL2 - page 36

    N ETWORK P LANNING 2-4 can be u sed for small netw orks attac hed to a s ingle switc h. Ho weve r , tagg ed VLAN s shou ld be used for larger net wo rks , and all th e VLANs assigned t o the i nter-switc h links. This switch also has a Pri vate VLAN feat ure. This allow s modification of the def ault VLAN to provide po rt-based secur ity and isol a ...

  • SMC Networks VDSL2 - page 37

    A PP LIC ATION N OTES 2-5 Applicati on Notes 1. Full-duplex operation on ly applies to point- to-point access (such as when a switc h is attached to a w orkstation, server or a nother switc h). When the switc h is connecte d to a hub , bot h device s mus t opera te in half-duplex mode. 2. T o intercon nect dis t inct VLANs o r IP subnets , yo u can ...

  • SMC Networks VDSL2 - page 38

    N ETWORK P LANNING 2-6 ...

  • SMC Networks VDSL2 - page 39

    3-1 C HAPTER 3 I NSTALLING THE S WITCH Preparing the Site for VDSL/POTS Connections In multi-tenant buildin gs , ph one lines from the ser vice provider enter the site and ar e ter minated at a location refer red to as the MPOE (Minim um P oint of E ntry). The MPOE is the “d emarcatio n” poin t where the ser vic e pro vider’ s ca bles end and ...

  • SMC Networks VDSL2 - page 40

    I NS TALL I NG THE S WITCH 3-2 Ins talli ng A ddit ional Equ ipm ent The V DSL switch should be installed c lose to the PBX, punch-down blocks, and patch pa nels, usually in th e baseme nt or w iring clo set. Y ou may also want t o install a ra ck for dis tributi on equipme nt (switch es , router s etc .), and extra punch-down blocks or pa tch pane ...

  • SMC Networks VDSL2 - page 41

    I NSTALLING E THER NET C ABLIN G 3-3 •T h e s i t e s h o u l d : - be at the center o f all th e devices yo u want t o link an d near a po wer outlet . - be ou t of dire ct sunlig ht, an d away f rom heat sourc es or are as with a high amount of el ectr omagne tic inte rference. The t emperat ure shoul d be within 0 to 50 °C (32 t o 122 °F) an ...

  • SMC Networks VDSL2 - page 42

    I NS TALL I NG THE S WITCH 3-4 • Protect ion from radio f requency interf erence em issions • Electri cal sur ge suppr ession • Separ ation of el ectrical wires (swit ch related or othe r) and elect romagn etic fi elds fr om data based netw ork wiri ng • Safe co nnecti ons wit h no dam aged cab les, connect o rs o r shield s Figure 3-3 RJ-4 ...

  • SMC Networks VDSL2 - page 43

    M OUNTING 3-5 If possible, retain the carton , including the origin al pac king materials. Use them again to repac k the pro duct in case th ere is a ne ed to return it for repair . Optional Rack-Mounting Equipment If you plan to rack-mou nt the sw itch, be sure to have the fo llowing equipmen t av ailable: • Four moun ting screws for each device ...

  • SMC Networks VDSL2 - page 44

    I NS TALL I NG THE S WITCH 3-6 T o rack-mount devices: 1. Attac h the brac ke ts to the device u sing the screw s pro vided in the Bracket Mounting K it. Figure 3-4 Attaching the Brackets 2. Mount the device in the ra c k, using fo ur rack-mounting s crews (not provided ). Figure 3-5 Installing the Switch in a Rack 100 240V 50 60Hz 1A -- Console 1 ...

  • SMC Networks VDSL2 - page 45

    M OUNTING 3-7 3. If installing a single switch onl y , tur n to Connectin g to a P ower Source on pag e 3-7. 4. If installing multiple swit c hes, mount them in the rack, one below the other, in any or der . Desktop or Shelf Mounting 1. Attach the fou r adhesive feet to the b ottom of the fir st switch. Figure 3-6 Attaching the Adhesive Feet 2. Set ...

  • SMC Networks VDSL2 - page 46

    I NS TALL I NG THE S WITCH 3-8 Installi ng an Optional SFP Transceiver Figure 3-7 Inserting an SFP Transceiver into a Slot Th e switch supp or t the followi ng option al transc eivers: T o in stall an SFP transceiv e r , do the following: 1. Cons ider ne twor k and ca bling r equireme nts to select an appr opriate SFP trans ceiv er type . 2. Insert ...

  • SMC Networks VDSL2 - page 47

    C ONNECTING TO A P OWER S OUR CE 3-9 Note: SFP transceive rs are not pr ovided in the s witch pac kage. Connect ing to a Power Source T o connect a device to a po wer so urce: 1. First ve rify that the external A C pow er supply can provide 100 to 240 V A C, 50-60 Hz, 1 A minimum. 2. Plug t he po wer cable into a grounde d, 3-pin , A C pow er sour ...

  • SMC Networks VDSL2 - page 48

    I NS TALL I NG THE S WITCH 3-10 and wi thout disrupting th e operat ion o f the devi ces att ached to the unit. Connect ing to the Co nsole Po rt Th e RJ-45 serial port on the switch’ s fron t panel is used to conn ect to th e switc h for out-of -band cons ole conf iguration. The on -board configur ation prog ram can be ac cessed from a te r mina ...

  • SMC Networks VDSL2 - page 49

    C ONNECTING TO THE C ONSOLE P ORT 3-11 The serial port’ s co nfiguration requirements are as fo llows: • Default Baud rate—9,600 bps • Cha ract er Size —8 Ch aracte rs •P a r i t y — N o n e •S t o p b i t — O n e • Data bits—8 • Flow co ntrol—non e See “ Conso le P ort Pin A ssig nment s” on p ag e B -9 for more detai ...

  • SMC Networks VDSL2 - page 50

    I NS TALL I NG THE S WITCH 3-12 ...

  • SMC Networks VDSL2 - page 51

    4-1 C HAPTER 4 M AKING N ETWORK C ONNECTI ONS The TigerAccess EE Swi tch is desig ned to connect subscrib er por ts via VDSL lines, and uplink to the ser vic e provider’ s network via twisted-pa ir or fibe r optic ca bling . The uplink ports can be co nnected to netw ork card s in PCs and s er vers , as w ell as to hubs , switches or routers . Th ...

  • SMC Networks VDSL2 - page 52

    M AKIN G N ETWORK C ONNECTIONS 4-2 each end. Typica lly 24 AWG (100 oh m)/0.5 mm wir e provides better performa nce than 26 AWG (10 0 ohm)/0. 5 mm wire . Connecting to the Pu nch-down Blocks The swit ch connects directly to t he PBX and building’ s phon e-line punch-down b lock with RJ -21 connec tors . F ollow the st eps listed below to connec t ...

  • SMC Networks VDSL2 - page 53

    C ONNECTING RJ-21 C ABL ES 4-3 Using Patch Panels F ollow th e steps below to connect a VDSL sw itch to a building’ s phone-l ine syst em using a patch panel: 1. Connect an RJ-21 cable from th e patch panel to th e RJ-21 connector s on th e rear o f the swi tch label ed “VD SL. ” If connect ing to a pre-wired patc h-panel wi th an RJ-21 conne ...

  • SMC Networks VDSL2 - page 54

    M AKIN G N ETWORK C ONNECTIONS 4-4 Connect ing Twi sted-Pai r Devi ces Each device requires an unshielded twisted-pair (UTP) cabl e with RJ-45 connectors at both ends . Use Categor y 5, 5e or 6 cable for 1000B ASE-T connections , Categ ory 5 or better for 100BASE-TX co nnections , and Categor y 3 o r better for 10BA SE-T connect ions . Cabling Guid ...

  • SMC Networks VDSL2 - page 55

    C ONNECTING T WISTED -P AIR D EVIC ES 4-5 Connecting to PCs, Ser vers, Hubs and Switches Depending on th e wiring config uratio n use d at the customer’ s s ite , separate wall jacks may be used for telephone and VDSL ser vices. Otherwise, you will need to connect the telep hone and co mputer directly to a CPE similar to that shown below . F or d ...

  • SMC Networks VDSL2 - page 56

    M AKIN G N ETWORK C ONNECTIONS 4-6 Connect ing Fibe r Optic Devices An optional SFP transcei ver (1000BAS E-SX, 1000BASE-LX o r 1000B ASE-ZX) can be used for a b ac kbone connection to your I nternet Servi ce Pr ovider , or for conn ecting to a high -speed se r ver . Each sing le-mode fiber port requires 9/125 micron single-mode fiber optic cab le ...

  • SMC Networks VDSL2 - page 57

    C ONNECTIVITY R ULES 4-7 3. Connect one en d of the cable t o the LC po r t on the sw itc h and th e other end to th e LC port on the other d evice . Since LC connectors are ke yed, th e cable c an be att ac hed in on ly one o rientati on. Figure 4-5 Making LC Port Connections 4. As a co nnection is made , chec k the Link LED o n the s witch corres ...

  • SMC Networks VDSL2 - page 58

    M AKIN G N ETWORK C ONNECTIONS 4-8 1000BASE-T Cable Requirements All Catego ry 5 UTP cables that are used for 100B ASE-TX connections should also wo rk for 1000B ASE-T , providing that all four wire pairs are connected. Howev er , it is re commended that for all critical connec tions , or any new cable inst allation s, Category 5e (enhanced Categor ...

  • SMC Networks VDSL2 - page 59

    C ONNECTIVITY R ULES 4-9 100 Mbps Fast Ethernet Cable Length s 10 Mbps Ethernet Cable Lengths Table 4-3 Maximum 1000BASE-LX Gigabit Ethern et Cable Length Fiber Size Fiber Bandw idth Maxi mum Ca ble Lengt h Connector 9/125 micr on single-mode fiber N/A 2 m - 10 km (7 ft - 6 .2 miles) LC Table 4-4 Maximum 1000BASE-ZX Gigabit Ethernet Cable Length Fi ...

  • SMC Networks VDSL2 - page 60

    M AKIN G N ETWORK C ONNECTIONS 4-10 Cable Labe ling and Con n ect ion Records When plannin g a netw ork installatio n, it is essential to label the opposing ends of cables and to record where each cable is connected. Doin g so will enable y ou to easily lo cate inter- connecte d devices , isolat e fault s and chan ge your t opology without n eed fo ...

  • SMC Networks VDSL2 - page 61

    A-1 A PPENDIX A T ROUBLESHOOTING Diagnosi ng Switch Indic ators This sw itch can be easily monito red through pane l indicators to identify proble ms .T he tab le below de scribes c ommon pr oblems you may encounte r and possible so lutions . Table A-1 Dia gnosing S witch Ind icators Symptom Possible Cause Action Power indicator does not light up a ...

  • SMC Networks VDSL2 - page 62

    T R OUBLESHOOTING A-2 Ethernet port Link indicator does not light up after maki ng a connection. Network cable or Ethernet device attached to this port may be defective. • Verify that the switch and attached device are powered on. • Be sure an Ethernet cabl e is plugged int o both the switch an d attached device . • Verify that the proper cab ...

  • SMC Networks VDSL2 - page 63

    P OWER AND C OOLING P RO B LE M S A-3 Power and Cooling Problems If the power indi cator does not tur n on when the power cord is pl ug ge d in, you m a y ha ve a probl em with the po wer outl et, p ow er cord , or int ernal power supply . However , if the unit powers off after runn ing for a while, check for lo ose power co nnect ions, power losse ...

  • SMC Networks VDSL2 - page 64

    T R OUBLESHOOTING A-4 Note: The switch can accept up to fo ur simul taneous T elnet se ssions. If the maximum number o f sessions alre ady exists, an additional Telnet conne ction will not be able to log into th e system. ...

  • SMC Networks VDSL2 - page 65

    B-1 A PPENDIX B C ABLES Twiste d-Pair Ca ble and Pin Assignm ents F or 10BASE-T/100B ASE-TX connections, a twisted-pair cable must have two p airs of wires . For 1000B ASE-T connections the twist ed-pair cable must hav e four pairs of wi res . Each wire p air is identi fied by two different color s . F o r ex ample , on e wire m ight be g reen and ...

  • SMC Networks VDSL2 - page 66

    C ABL ES B-2 10BASE-T/100BASE-TX Pin Assign ments Use unshie lded twiste d-pair (UTP) o r shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Categ or y 3 or better cable for 10 Mbps connections , or 100-ohm Catego ry 5 or better cable for 100 Mbp s connec tions . Also be sure that t he len gth of any twisted- pair co nnection does not ...

  • SMC Networks VDSL2 - page 67

    T WISTED -P AIR C ABL E AND P IN A SSIGNMENTS B-3 Straight-Through W iring If the twiste d-pair cable is to jo in two ports and on ly one of the por ts has an inter nal cross ov er (MDI-X ), the two pairs of wires mus t be straight- throug h. (When auto-negoti ation is en abled f or any RJ -45 por t on this switch , you can use eit her st raight-th ...

  • SMC Networks VDSL2 - page 68

    C ABL ES B-4 Crossov er Wiring If the t wisted-pa ir cable is to jo in two port s and eithe r both por ts ar e labeled with an “X” (in dicating MDI-X ) or neither port is labeled with an “X” (whic h indicates MDI), a cros sov er mus t be i mplemen ted in the wiring . (When auto -negotia tion i s enabl ed fo r any RJ -45 po rt on this switch ...

  • SMC Networks VDSL2 - page 69

    T WISTED -P AIR C ABL E AND P IN A SSIGNMENTS B-5 1000BASE-T Pin Assi gnments 1000BASE-T ports switch suppor t automatic MDI/MDI-X operation, so you can us e strai ght-throu gh cables f or all network c onnectio ns to PCs or servers , or to othe r switches or hubs . The table below shows the 1000B ASE-T MD I and MDI-X port pinouts . Th ese por ts r ...

  • SMC Networks VDSL2 - page 70

    C ABL ES B-6 1000BASE-T Cable Requirements All Catego ry 5 UTP cables that are used for 100B ASE-TX connections should also wo rk for 1000B ASE-T , providing that all four wire pairs are connected. Howev er , it is re commended that for all critical connec tions , or any new cable inst allation s, Category 5e (enhanced Categor y 5) or Categor y 6 c ...

  • SMC Networks VDSL2 - page 71

    F IBER S TAND ARDS B-7 Fiber Stan dards The cur rent TIA (T elecommunications Industry As sociation) 568-A specification o n optical fiber cablin g consists of on e recognized cabl e type for ho rizontal su bsyst ems and tw o cab le type s for backbo ne subs ystems . Horiz ontal 62.5/125 micron m ultimode (two fibers per outlet). Backbone 62.5/125 ...

  • SMC Networks VDSL2 - page 72

    C ABL ES B-8 RJ-21 Port Pi n Assign ments The RJ-21 ports are designed t o ag greg ate 24 POTS/VDS L lines , although only 16 lines are implemente d for this switch. Each wire pair m ust be attac hed to the RJ-21 connector in a specific orient ation de tailed belo w . Th e following tables show th e pin ass ignment s . Figure B-4 RJ-21 Port Pins Th ...

  • SMC Networks VDSL2 - page 73

    C ONSOLE P ORT P IN A SSIGNMENTS B-9 Console Port Pin Assignments The DB-9 seria l port on the s witch ’ s front panel is used t o conn ect to th e switch for out-of -band co nsole co nfigur ation. The on -board comman d- line configur ation program can be acc essed from a t er minal or a PC running a te r minal em ulation prog ram. The pi n assi ...

  • SMC Networks VDSL2 - page 74

    C ABL ES B-10 Console Port t o 9-Pin DTE Port o n PC Console to 25-Pin DTE Port on PC Table B-6 Console Port to 9-Pin DTE Port on PC Switch’s 9-Pin Serial Por t Null Mo dem PC’s 9-Pin DTE Port 2 RXD <--- ------ TXD -- ------- ---> 3 TXD 3 TXD --- ------- - RXD ------ ----> 2 RXD 5 SGND <----------- SGND ------ ----> 5 SGND No oth ...

  • SMC Networks VDSL2 - page 75

    C-1 A PPENDIX C S PECIFICATIONS Physical Characteristics VDSL Specifications Band Pl an: Up to 6 ba nds Signal Bandwidth: 25 kHz to 30MHz Data Rate: Up to 100 Mbps / 100 Mbps (Downstream/Upstream) Range: Up to 200 meters (656 ft) Optional Band: US0 from 4~25 kHz ( lo w end) to 138~276 kH z (high end) Multi-Car rier-Modulation (MCM) - DMT mo dulatio ...

  • SMC Networks VDSL2 - page 76

    P HYS I CA L C HARACT ERIS TICS C-2 Buffer Ar chitecture 16 Mbytes Aggregate Bandwidth 8.8 Gbps Switchin g Database 8K MA C address entries LEDs System : P owe r, Diag, F ault Po r t : L i n k / A c t We i g h t 2.92 kg (6.44 lb) Size 44.0 x 35.2 x 6.6 cm (17.4 x 13.9 x 2.6 in.) Te m p e r a t u r e Operating: 0 to 50 °C (32 to 122 °F) Storage: - ...

  • SMC Networks VDSL2 - page 77

    S PECIFICATIONS C-3 Switch Features F orw arding Mode Store-and-fo rward Throughput La yer 2: wi re speed Flow Co ntro l Full Duplex: IEEE 802.3x Half Duplex: Ba ck pressure Management Features In-Band Management W eb , T elnet, SSH, or SNMP manager Out-of-Band Mana gement Console port (RS-232 DB- 9) Isolate d manage ment por t, Gi gabit E ther net ...

  • SMC Networks VDSL2 - page 78

    S TANDA RDS C-4 Standards Ether net Standards IEEE 802.3-2005 Ethern et Access Ethernet, Fast Ethernet, Gig abi t Ethe r net Link A g g regation Cont rol Pro tocol ( LA CP) Full-duplex flow control (ISO/IEC 8802-3) IEEE 802.1D Spanning T ree Protocol IEEE 802.1w Rapid Span ning T ree Protocol IEEE 802.1s Multiple Spanning T ree Protocol IEEE 802.1p ...

  • SMC Networks VDSL2 - page 79

    S PECIFICATIONS C-5 Safety CSA/CUS (CSA 22.2. NO 60950-1 & UL60950-1) CB (IEC60950-1) ...

  • SMC Networks VDSL2 - page 80

    C OMPLIANCES C-6 ...

  • SMC Networks VDSL2 - page 81

    D-1 A PPENDIX D O RDERING I NFORMATION Table D-1 TigerAccess EE Products and Accessories Product Numb er Description SMC7816M/VSW 16-Port VDSL2 Switch with 2 combo Gigabit Ethernet uplink por ts (RJ-45/SFP) and 1 dedicated Fast Ethernet ma nagement port (RJ-45) SMC7800A/VCP Ethernet-over-VDSL2 CPE with 1 VDSL line port, 1 POT S phone port, and 1 Fa ...

  • SMC Networks VDSL2 - page 82

    O RDERING I NFOR MATION D-2 ...

  • SMC Networks VDSL2 - page 83

    Glossary-1 G LOSSARY 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet ov er tw o pairs of Categor y 3, 4, or 5 UTP cable . 100BASE-TX IEEE 802.3u specification for 100 Mbps F ast Ethernet ove r two pa irs of Categor y 5 UTP cable . 1000BASE-LX IEEE 802.3z specification for Gig abit Ethern et ov er two strands of 50/ 125, 62.5/125 or 9/125 mic ...

  • SMC Networks VDSL2 - page 84

    G LOSSAR Y Glossary-2 Bandwidth The differ ence bet ween t he hi ghest a nd low est frequ encies ava ilable f or network signals. Also sy nonymou s with wire speed, the actua l speed of the data transmi ssion alo ng the cable . Collis ion A condit ion in whic h packe t s tr ansmitt ed ov er the cabl e inter fere with each other . Their interference ...

  • SMC Networks VDSL2 - page 85

    G LOSSAR Y Glossary-3 Fast Ethernet A 100 Mbps network comm unication system based on Ethernet and the CSMA/CD access method. Fibre To The Home (FTT H) Network wher e an op tical fibre r uns from the tele phone sw itch to the subscr iber's premises or home . Full Duplex T ransmi ssion meth od that allows two network device s to trans mit and r ...

  • SMC Networks VDSL2 - page 86

    G LOSSAR Y Glossary-4 IEEE 802.3x Defin es Ethernet fram e st art/sto p reques ts and timers use d for flow control on full-duplex links . (Now incorporated in IEEE 802.3-2005.) IEEE 802.3z Defines CSMA/CD acce ss metho d and ph ysical la yer specificat ions for 1000B ASE Gig abit Ether net. (Now incor porated in IEEE 802.3-2005.) LAN Segment Separ ...

  • SMC Networks VDSL2 - page 87

    G LOSSAR Y Glossary-5 Media Access Control (MAC) A portio n of the netw orki ng prot ocol that g o ve r ns acces s to t he transmission medium, facilitating the exch ange of data between network nodes. Modal Bandwidth Bandwi dth for m ultimod e fibe r is refer red to as modal ba ndwidt h becaus e it v aries with th e modal fi eld ( or core d i amet ...

  • SMC Networks VDSL2 - page 88

    G LOSSAR Y Glossary-6 TIA T elecommunications In dustr y Association Transmission Control Protocol/Internet Protocol (TCP/IP ) Proto col suite t hat inc ludes TCP as the pr imar y trans por t prot ocol, an d IP as the netw ork la yer protoc ol. User Datagra m Protocol (UDP) UDP pro vides a d atag ram mode for pa ck et-swi tche d communica t ions . ...

  • SMC Networks VDSL2 - page 89

    G LOSSAR Y Glossary-7 Virtual LAN (VLAN) A Virtual L AN is a co llectio n of netw ork nodes th at share the same collision domain reg ardless of their physical location or c onnection point in the ne twork. A VLAN ser ves as a logical workg roup wit h no physical bar riers , allowing users to share in for mation and re sources as t hough located on ...

  • SMC Networks VDSL2 - page 90

    G LOSSAR Y Glossary-8 ...

  • SMC Networks VDSL2 - page 91

    Index-1 Numerics 10 Mbps connect ivity rules 4-9 100 Mbps connectivity ru les 4 -9 1000 Mbps connectivity rules 4-8 1000BASE-LX connections 4-6 fiber cable le ngths 4-9 1000BASE-SX connections 4-6 fiber cable le ngths 4-8 1000BASE-T cable lengths 4-8 1000BASE-X c onnections 4-6 1000BASE-ZX connections 4-6 fiber cable le ngths 4-9 100BASE-TX cable l ...

  • SMC Networks VDSL2 - page 92

    I NDE X Index-2 H hardware components 1-5 hardware, basi c description 1-5 I IEEE 802.3 Ethernet 1-12 IEEE 802.3- 2005 1-12 IEEE 802.3u Fast Ethe rnet 1-1 2 IEEE 802.3z Gigabit Ethernet 1-12 indicators, LED 1-8 installation connecting devi ces to the CPE 4-5 desktop or she lf mounting 3- 7 port connections 4-1 , 4-4 problems A-3 site requirements 3 ...

  • SMC Networks VDSL2 - page 93

    I NDEX Index-3 rubber foot pads, at taching 3-7 S SC port connection s 4-6 screws for rack mounting 3-5 SFP slots 1-7 supported transc eivers 1-7 single-mode fi ber optic cables 4-6 site req ui rem ents 3 -2 selelction 3-2 SNMP agent 1-4 specificat ions compliances C-4 environmental C-2 manage ment featu res C-3 physical C- 1 switching features C-3 ...

  • SMC Networks VDSL2 - page 94

    I NDE X Index-4 ...

  • SMC Networks VDSL2 - page 95

    ...

  • SMC Networks VDSL2 - page 96

    20 Mason Irvine, CA 92618 Phone: (9 49) 679-8000 Model Numbers: SMC7800A/VCP Pub. Number: 149 100012100 H E02200 7/ST -R01 FOR TECHNICAL SUPPOR T , CALL: From U.S.A. an d Canada (2 4 hours a day , 7 da ys a week) (800) SMC-4-YOU; (94 9) 679-8000; F ax: (949 ) 679-1481 Fro m Euro pe: Cont act deta ils can be found on www .sm c-europe. com o r www .s ...

Manufacturer SMC Networks Category Switch

Documents that we receive from a manufacturer of a SMC Networks VDSL2 can be divided into several groups. They are, among others:
- SMC Networks technical drawings
- VDSL2 manuals
- SMC Networks product data sheets
- information booklets
- or energy labels SMC Networks VDSL2
All of them are important, but the most important information from the point of view of use of the device are in the user manual SMC Networks VDSL2.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals SMC Networks VDSL2, service manual, brief instructions and user manuals SMC Networks VDSL2. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product SMC Networks VDSL2.

A complete manual for the device SMC Networks VDSL2, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use SMC Networks VDSL2 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of SMC Networks VDSL2.

A complete SMC Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual SMC Networks VDSL2 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the SMC Networks VDSL2, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the SMC Networks VDSL2, that we can find in the current document
3. Tips how to use the basic functions of the device SMC Networks VDSL2 - which should help us in our first steps of using SMC Networks VDSL2
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with SMC Networks VDSL2
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of SMC Networks VDSL2 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning SMC Networks VDSL2?

Use the form below

If you did not solve your problem by using a manual SMC Networks VDSL2, ask a question using the form below. If a user had a similar problem with SMC Networks VDSL2 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)