Manual Sharp CV-P13LJ

32 pages 1.95 mb
Download

Go to site of 32

Summary
  • Sharp CV-P13LJ - page 1

    PORT ABLE TYPE ROOM AIR CONDITIONER INST ALLA TION AND OPERA TION MANUAL H S I L G N E L O Ñ A P S E CV-P10LJ CV-P13LJ ...

  • Sharp CV-P13LJ - page 2

    ENGLISH This manual explains the proper use of your new air conditioner . Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CONTENTS • USAGE CAUTIONS ........................... .................................... ...... E-2 • PRECAUTIONS ................................ ...

  • Sharp CV-P13LJ - page 3

    ENGLISH E- 2 USAGE CAUTIONS • V entilate the room periodically during use, especially if using gas appliances. • Be sure to turn the unit off and disconnect the power supply cord before performing any mainte- nance or cleaning. • Do not splash or pour water directly onto the unit. W ater can cause electrical shock or equipment damage. • Dra ...

  • Sharp CV-P13LJ - page 4

    MIN.12" (30cm) MIN.12" (30cm) PRECAUTIONS E- 3 OPERA TING CONDITIONS • The air conditioner must be operated within the temperature range indicated below . MODE Room temperature Cool 18 ° C ~ 35 ° C Dehumidifi cation 1 5° C ~ 3 5° C • A built-in safety device may cut off operation if the temperature exceeds these limits. • When ...

  • Sharp CV-P13LJ - page 5

    Exhaust hose 1 Rain guard 2 Window exhaust Extensi on panel adapter 1 Insect guard net 1 1 1 Foam seal A 1 Exhaust hose adapter 1 Foam seal B (adhesive type) 1 Bracket Manual 1 3 Remote control 1 Screw 8 Battery (AAA.1.5V) 2 E- 4 INCLUDED SUGGESTED TOOLS FOR WINDOW P ANEL INST ALLA TION 1. Screwdriver(medium size Phillips) 2. T ape measure or ruler ...

  • Sharp CV-P13LJ - page 6

    P ART NAMES 1 Air Outlet 2 V ertical louvers 3 Horizontal louvers 4 POWER Button 5 Remote control signal receiver window 6 OPERA TION Lamp (red) 7 TIMER Lamp (orange) 8 MEGA COOL Lamp (green) 9 PLASMACLUSTER Lamp (blue) 0 Air inlet REAR VIEW NOTE: Actual unit might vary slightly from above illustration. FRONT VIEW q Insect guard net w Window exhaus ...

  • Sharp CV-P13LJ - page 7

    ENGLISH REMOTE CONTROL 1 T ransmitter 2 Display 3 POWER Button 4 LIGHTS Button 5 TEMPERA TURE Button 6 PLASMACLUSTER Button 7 SLEEP Button 8 MODE Button 9 ON TIMER Button 0 F AN Button q OFF TIMER Button w CANCEL Button e LOUVERS Button r RESET Button t MEGA COOL Button E- 6 y MODE SYMBOLS : COOL : DEHUMIDIFICA TION : F AN : VENTILA TION u MEGA COO ...

  • Sharp CV-P13LJ - page 8

    INST ALL WINDOW P ANEL Hole Projection Insect guard net Rain guard "A" Window panel Projection "A" Window panel E- 7 Foam seal A (adhesive type) Installation in a double-hung sash window (See page 9 for installation in a sliding sash window . ) 1 Connect the rain guards to the insect guard net. Insert all three projections on ea ...

  • Sharp CV-P13LJ - page 9

    Foam seal A (adhesive type) Adjustment panel Extension panel E- 8 If the inner width of the window is between 24" (609mm) and 36.8" (934mm) inclusive. (1) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to fi t the window frame width. (3) Secure the window panel to the stool with 3 scre ...

  • Sharp CV-P13LJ - page 10

    INST ALL WINDOW P ANEL Installation in a sliding sash window Hole Projection Insect guard net Rain guard "A" Window panel Projection "A" Window panel E- 9 1 Connect the rain guards to the insect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be uppermost, ...

  • Sharp CV-P13LJ - page 11

    If the inner height of the window is between 24" (609mm) and 36.8" (934mm) inclusive. (1) Open the window sash and place the window panel on the window frame. (2) Slide the adjustment panel to fi t the window frame height. (3) Secure the window panel to the window frame with 3 screws. If the inner height of the window is be- tween 36.8&q ...

  • Sharp CV-P13LJ - page 12

    Exhaust hose Window ex- haust adapter Projection Extend Hole "TOP" E-1 1 The exhaust hose must be installed or removed in accordance with the usage mode. MODE EXHAUST HOSE COOL, F AN, VENTILA TION, DEHUMIDIFICA TION with no container Install DEHUMIDIFICA TION with container Remove Installation of the exhaust hose 1 Attach the window exhau ...

  • Sharp CV-P13LJ - page 13

    "PUSH" Projection E-1 2 Removal of the exhaust hose 1 Remove the window exhaust adapter . Pull out and remove the window exhaust adapter by pushing down two “PUSH” markings, and slide and close the exhaust cover in the window panel. 2 Remove the exhaust hose adapter from the unit. Lift up and remove the exhaust hose adapter from the u ...

  • Sharp CV-P13LJ - page 14

    E-1 3 NOTES: • The battery should last approximately one year under normal use. • When replacing the batteries, always change both batteries at the same time, and make sure they are the same type. • If the remote control does not operate normally after replacing the batteries, press the RESET button using a thin pointed implement. • If you ...

  • Sharp CV-P13LJ - page 15

    ENGLISH E- 14 CAUTION • Do not expose the signal receiver window to direct sunlight. This may adversely affect its operation. If necessary , close the curtains to block out the sunlight. • Use of a fl uorescent lamp in the same room may interfere with transmission of the signal. • The unit may be affected by signals emitted from other remote ...

  • Sharp CV-P13LJ - page 16

    E- 15 COOL MODE Ensure that the stopcock is securely attached the drainpipe. 1 Press the MODE button to select COOL mode. COOL DEHUM F AN VENT 2 Press the POWER button to start opera- tion. • The red OPERA TION lamp on the unit will light. 3 Press the TEMPERA TURE button to set the desired temperature. • The temperature can be set within the ra ...

  • Sharp CV-P13LJ - page 17

    E- 16 F AN MODE VENTILA TION MODE 2 1 3 2 1 3 In this mode, the air conditioner simply circulates the air without cooling it. In this mode, the air conditioner ventilates the air to outdoors. 1 Press the MODE button to select F AN mode. COOL DEHUM F AN VENT 2 Press the POWER button to start operation. • The red OPERA TION lamp on the unit will li ...

  • Sharp CV-P13LJ - page 18

    T O CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION NOTE • During VENTILA TION mode, UP/DOWN air fl ow direction cannot be changed. Hold the vertical louver as shown in the dia- gram and adjust the air fl ow direction. 1 Press the LOUVERS button on the re- mote control. • The horizontal louvers will swing continu- ously . 2 Press the L ...

  • Sharp CV-P13LJ - page 19

    ENGLISH E- 18 1 Press the PLASMACLUSTER button during operation. • The remote control will display “ ”. • The blue PLASMACLUSTER lamp on the unit will light. TO CANCEL Press the PLASMACLUSTER button again. • The PLASMACLUSTER lamp on the unit will turn off. NOTES: • Use of the PLASMACLUSTER function will be memorized and it will be acti ...

  • Sharp CV-P13LJ - page 20

    1 Press the MEGA COOL button during cooling mode. • The remote control will display " " . • The temperature display will go of f. • The green MEGA COOL lamp on the unit will light. TO CANCEL Press the MEGA COOL button again. • MEGA COOL operation is also cancelled when the mode is changed, or when the unit is turned off. • The g ...

  • Sharp CV-P13LJ - page 21

    ENGLISH 0.5h 1.0h 1.5h 10h 1 1h 12h ON TIMER 1 Press the ON TIMER button. • The time setting will change as you press the button as follows. Hold the button down to speed through the settings. • The orange TIMER lamp on the unit will light. • The time setting will count down to show the remaining time. TO CANCEL TIMER Press the CANCEL button. ...

  • Sharp CV-P13LJ - page 22

    Prepare for drainage and drain out water within the unit in the following cases. • When the unit stops operating and the TIMER, OPERA TION and MEGA COOL lamps are blinking, the water tank is full and need to be drained. • When the unit is not used for a long time. 1 Unplug the power plug and move the unit to a drain or outside. 2 Remove the sto ...

  • Sharp CV-P13LJ - page 23

    ENGLISH E- 22 CLEANING THE UNIT AND THE REMOTE CONTROL Wipe them with a soft, dry cloth or with a cloth moistened with a mild soap. Carefully remove any residue by wiping with a damp cloth and dry completely . Avoid splashing water onto the unit. W ater can dangerously damage the electrical insulation. Never use harsh chemicals or abrasive cleaners ...

  • Sharp CV-P13LJ - page 24

    BEFORE CALLING FOR SER VICE If the unit appears to be malfunctioning, check the following points before calling for a service. AIR CONDITIONER DOES NOT OPERA TE A T ALL • Is the unit plugged in or is the plug loose? • Has the fuse blown or is the circuit breaker tripped? • Did you restart the unit within 3 minutes of a power failure? If the p ...

  • Sharp CV-P13LJ - page 25

    Technical Specifications Sr No Parameter Unit Value 1 Model CV-P10LJ Rated Voltage V ~ 220-240 Rated Frequency Hz 50 2 Power Supply Phases 1 3 Cooling Capacity W 2930 4 Cooling Power Input W 1100 5 Cooling Power Current A 4.80 6 Rated Input W 1250 7 Rated Current A 5.80 8 Air Flow Volume(H/M/L) m 3 /h 350/260/180 9 Dehumidifying Volume L/h 1 10 E ...

  • Sharp CV-P13LJ - page 26

    28 Refrigerant R410A 29 Refrigerant Charge kg 0.67 30 Compressor LANDA COMPRESSOR 31 Compressor Model QXA-B102T130 32 Compressor Oil RB68EP 33 Compressor Type Rotary 34 L.R.A. A 19.00 35 Compressor RLA A 3.90 36 Compressor Compressor Power Input W 850 37 Fan Type Centrifugal 38 Diameter Length(DXL) mm φ 227 X 109 39 Fan Motor Speed(H/ML) r/min 950 ...

  • Sharp CV-P13LJ - page 27

    Technical Specifications Sr No Parameter Unit Value 1 Model CV-P13LJ Rated Voltage V ~ 220- 240 Rated Frequency Hz 50 2 Power Supply Phases 1 3 Cooling Capacity W 3550 4 Cooling Power Input W 1360 5 Cooling Power Current A 6.00 6 Rated Input W 1550 7 Rated Curre nt A 7.20 8 Air Flow Volume(H/M/L) m 3 /h 350/260/180 9 Dehumidifying Volume L/h 1 10 ...

  • Sharp CV-P13LJ - page 28

    28 Refrigerant R410A 29 Refrigerant Charge kg 0.95 30 Compressor MITSUBISHI 31 Compressor Model RN125VHFMC 32 Compressor Oil PVE(FV50S or similar) 33 Compressor Type Rotary 34 L.R.A. A 23.00 35 Compressor RLA A 4.70 36 Compressor Compressor Power Input W 1030 37 Fan Type Centrifugal 38 Diameter Length(DXL) mm φ 227 X 109 39 Fan Motor Speed(H/ML) r ...

  • Sharp CV-P13LJ - page 29

    Congratulations on Your Purchase! This Sharp product is warranted against faults in materials and manufacture for a period of twelve (12) months from the date of original purchase. (excluding lamps and air filters. ) If service is required during the warranty period, please contact your nearest Sharp Approved Service Centre. These repairs would be ...

  • Sharp CV-P13LJ - page 30

    FOR LOCATION ENQUIRIES WITHIN NEW ZEALAND REGARDING YOUR LOCAL SHARP CORPORATION OF NEW ZEALAND LIMITED VISIT OUR WEBSITE AT SHARP CUSTOMER SERVICES TELEPHONE: 09 573 0111 FACSIMILE: 09 573 0113 FOR LOCATION ENQUIRIES WITHIN AUSTRALIA REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.au OR CALL SHARP CUSTOMER CAR ...

  • Sharp CV-P13LJ - page 31

    ...

  • Sharp CV-P13LJ - page 32

    SHARP CORPORATION OF AUSTRALIA PTY LTD ABN 40 003 039 405 1 Huntingwood Drive HUNTINGWOOD NSW 2148 www.sharp.net.au 66129905937 ...

Manufacturer Sharp Category Air Conditioner

Documents that we receive from a manufacturer of a Sharp CV-P13LJ can be divided into several groups. They are, among others:
- Sharp technical drawings
- CV-P13LJ manuals
- Sharp product data sheets
- information booklets
- or energy labels Sharp CV-P13LJ
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sharp CV-P13LJ.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sharp CV-P13LJ, service manual, brief instructions and user manuals Sharp CV-P13LJ. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sharp CV-P13LJ.

Similar manuals

A complete manual for the device Sharp CV-P13LJ, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sharp CV-P13LJ by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sharp CV-P13LJ.

A complete Sharp manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sharp CV-P13LJ - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sharp CV-P13LJ, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sharp CV-P13LJ, that we can find in the current document
3. Tips how to use the basic functions of the device Sharp CV-P13LJ - which should help us in our first steps of using Sharp CV-P13LJ
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sharp CV-P13LJ
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sharp CV-P13LJ in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sharp CV-P13LJ?

Use the form below

If you did not solve your problem by using a manual Sharp CV-P13LJ, ask a question using the form below. If a user had a similar problem with Sharp CV-P13LJ it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)