Manual Mitsubishi Electronics 36FL3

12 pages 0.86 mb
Download

Go to site of 12

Summary
  • Mitsubishi Electronics 36FL3 - page 1

    Air -Conditioner s PLH18, 24, 30, 36, 42AK PL12, 18, 24, 30, 36, 42AK PCH24, 30, 36, 42GK PC24, 30, 36, 42GK PKH18, 24, 30, 36FK3 PK12, 18, 24, 30, 36FK3 PKH18, 24, 30, 36FL PK18, 24, 30, 36FL3 OPERA TION MANU AL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. FOR USER ...

  • Mitsubishi Electronics 36FL3 - page 2

    2 s Before installing the unit, make sure you read all the “Safety precautions”. s The “Safety precautions” provide very important points regarding safety . Make sure you f ollow them. s If none of the above apply , turn the main switc h off and contact the dealer from whom y ou bought the air-conditioner , telling him the model name and th ...

  • Mitsubishi Electronics 36FL3 - page 3

    3 ON/OFF – TIMER SET SET TEMP. REMOTE CONTROLLER MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER AIR SWEEP CHECK TEST RUN STAND BY DEFROST DRY COOL AUTO FAN HEAT CENTRALLY CONTROLLED ˚ F SWING FAN SPEED AUTO RETURN NOT AVAILABLE ˚ F CHECK MODE FILTER TIMER TEST RUN TIMER OFF CLOCK AUTO AUTO CHECK SET TEMP. START STOP A 1 2. Operati ...

  • Mitsubishi Electronics 36FL3 - page 4

    4 ON/OFF – TIMER SET SET TEMP. REMOTE CONTROLLER MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER AIR SWEEP CHECK TEST RUN STAND BY DEFROST DRY COOL AUTO FAN HEAT CENTRALLY CONTROLLED ˚ F SWING FAN SPEED AUTO RETURN NOT AVAILABLE ˚ F CHECK MODE FILTER TIMER TEST RUN TIMER OFF CLOCK AUTO AUTO CHECK SET TEMP. START STOP F 1 2. Operati ...

  • Mitsubishi Electronics 36FL3 - page 5

    5 C B D A ON/OFF – STAND BY DEFROST DRY COOL AUTOFAN HEAT CENTRALLY CONTROLLED ˚ F SWING FAN SPEED AUTO RETURN NOT AVAILABLE ˚ F CHECK MODE FILTER TIMER TEST RUN TIMER OFF CLOCKAUTOAUTO CHECKSET TEMP. STARTSTOP B A D C 3. Care and cleaning Caution: • Always turn off the po wer , first on the remote contr oller and then the main switch, before ...

  • Mitsubishi Electronics 36FL3 - page 6

    6 4. T roubleshooting NOTE: After a po wer cut, the unit will not restart automatically . Y ou will have to restart it by pressing the PO WER - ON/OFF but ton on the remote controller . Wired remote controller s In any of the following cases, turn off the main power switch and contact your local dealer for service: •“ CHECK ” f ollowed b y ? ...

  • Mitsubishi Electronics 36FL3 - page 7

    7 PLH18AK PLH24AK PLH30AK PLH36AK PLH42AK 18,000 24,000 30,000 35,400 42,000 19,000 [24,500/25,500] 26,000 [31,500/32,500] 33,000 [39,500/41,200] 38,000 [45,900/47,600] 44,300 [52,200/53,900] 11,000 [16,500/17,500] 16,500 [22,000/23,000] 18,500 [25,000/26,700] 23,000 [30,900/32,600] 26,800 [34,700/36,400] 1.75 2.57 3.17 3.63 3.98 1.59 [3.19/3.49] 2 ...

  • Mitsubishi Electronics 36FL3 - page 8

    8 PL12AK PL18AK PL24AK PL30AK PL36AK PL42AK 12,500 18,400 24,000 31,000 36,500 42,500 1.26 1.85 2.65 3.17 3.64 4.08 10.1 10.2 10.0 10.6 10.5 10.8 PL12AK PL18AK PL24AK PL30AK PL36AK PL42AK Galvanized sheets with gray heat insulation Munsell 0.7Y 8.59/0.97 115, 1, 60 15 2.0 3.0 1.2 2.6 420-560 530-710 710-990 780-1060 390-530 490-670 670-950 740-1020 ...

  • Mitsubishi Electronics 36FL3 - page 9

    9 PCH24GK PCH30GK PCH36GK PCH42GK 24,000 30,000 35,400 42,000 27,000 [34,000/35,500] 33,000 [40,500/42,500] 38,000 [45,500/47,500] 45,000 [52,500/54,500] 14,800 [21,800/23,300] 20,000 [27,500/29,500] 21,000 [28,500/30,500] 23,800 [31,300/33,200] 2.51 3.23 3.60 4.10 2.46 [4.49/4.94] 3.00 [5.25/5.76] 3.32 [5.57/6.08] 3.76 [6.03/6.52] 1.95 [3.98/4.43] ...

  • Mitsubishi Electronics 36FL3 - page 10

    10 PC24GK PC30GK PC36GK PC42GK 25,000 31,000 36,500 42,500 2.61 3.18 3.62 4.10 10.4 10.0 10.3 10.8 PC24GK PC30GK PC36GK PC42GK Munsell 0.7Y 8.59 / 0.97 115, 1, 60 15 2.0 3.0 1.9 2.4 710-880 990-1,240 640-810 880-1,130 51-9/16 63-3/4 26-3/4 10-5/8 82 95 99 PU24EK PU30EK PU36EK PU42EK7 Munsell 5Y 7/1 208/230, 1, 60 20 30 40 16 20 22 28 0.65+0.65 0.75 ...

  • Mitsubishi Electronics 36FL3 - page 11

    11 5. Specifications Cooling *1 BTU/h Capacity Heating *1,*3 BTU/h Heating *2,*3 BTU/h Cooling *1 kW Heating *1,*3 kW Heating *2,*3 kW SEER HSPF INDOOR UNIT MODELS External finish P ower supply V , Phase, Hz Max. fuse size (time delay) A Min. ampacity A F an motor F . L. A. Auxiliary heater A (kW) Airflow Dry CFM Lo-Hi Wet CFM Wi n Dimensions D in ...

  • Mitsubishi Electronics 36FL3 - page 12

    12 Printed in Japan BG79P948H04 HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MAR UNOUCHI, CHIY ODA-KU , TOKY O 100-8310, JAP AN 5. Specifications Cooling capacity *1 BTU/h P ower consumption *1 kW SEER INDOOR UNIT MODELS External finish P ower supply V , Phase, Hz Max. fuse size (time delay) A Min. ampacity A F an motor F . L. A. Airflow Dry CFM Lo- ...

Manufacturer Mitsubishi Electronics Category Air Conditioner

Documents that we receive from a manufacturer of a Mitsubishi Electronics 36FL3 can be divided into several groups. They are, among others:
- Mitsubishi Electronics technical drawings
- 36FL3 manuals
- Mitsubishi Electronics product data sheets
- information booklets
- or energy labels Mitsubishi Electronics 36FL3
All of them are important, but the most important information from the point of view of use of the device are in the user manual Mitsubishi Electronics 36FL3.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Mitsubishi Electronics 36FL3, service manual, brief instructions and user manuals Mitsubishi Electronics 36FL3. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Mitsubishi Electronics 36FL3.

A complete manual for the device Mitsubishi Electronics 36FL3, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Mitsubishi Electronics 36FL3 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Mitsubishi Electronics 36FL3.

A complete Mitsubishi Electronics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Mitsubishi Electronics 36FL3 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Mitsubishi Electronics 36FL3, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Mitsubishi Electronics 36FL3, that we can find in the current document
3. Tips how to use the basic functions of the device Mitsubishi Electronics 36FL3 - which should help us in our first steps of using Mitsubishi Electronics 36FL3
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Mitsubishi Electronics 36FL3
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Mitsubishi Electronics 36FL3 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Mitsubishi Electronics 36FL3?

Use the form below

If you did not solve your problem by using a manual Mitsubishi Electronics 36FL3, ask a question using the form below. If a user had a similar problem with Mitsubishi Electronics 36FL3 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)