  • Xantrex 300 - page 1

    Xantrex Inverter 300 Owner ’ s Guide 445-0 139-01-01 Print ed in China Web: www.xantrex.com Email: CustomerService@xantrex.com Phone: 1-604 -422-8595 Phone: 1-800-67 0-0707 (toll free in North Ame rica) Fax: 1-604 -420-1591 Fax: 1-800-99 4-7828 (toll free in North Ame rica) ...

  • Xantrex 300 - page 2

    About Xantre x Xantrex T e ch nology Inc. is a w o rld-leadin g su ppl ie r of a dvanced pow e r elect roni cs a nd c ontrols with prod ucts from 50 watt mo bil e units to 1 MW utility-scale systems for wind, solar , batteries, fuel cells, microturb ines, and backup pow e r app li ca tions i n both grid-connec ted and stand-al one systems. Xantrex ...

  • Xantrex 300 - page 3

    ...

  • Xantrex 300 - page 4

    Contents 1 1. Introductio n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. Important Safet y Information . . . . . . . . . . . . . . . . . . 2 Warnings and C autions . . . . . . . . . . . . . . . . . . . . . . . . 2 3. Xantrex 300 Inverter Features . . . . . . . . . . . . . . . . . . 5 AC Outlets . . . . . . . . . . . . . . ...

  • Xantrex 300 - page 5

    2 ...

  • Xantrex 300 - page 6

    1 Introduction Thank you for purchasing the Xantrex 300 Inverter. The 300 I nverter is part o f a family of adva nced, high- performance po wer inverters from Xantrex, the leader in the field of high-frequency i nverter design. Connected t o the 12 volt outl et in your vehicle o r boat or directly to your battery for loads over 150 watts, the 300 I ...

  • Xantrex 300 - page 7

    2 2 Important Safety Information If the 300 Inverter is connected or us ed incorrectly , hazardous cond itions may be created. Read and save this safety information, and pay special atten tio n to all Caution and W arning statements in the guide and on the inv erter itself. W arnings and Caut i ons are indicated by this symbol : • Wa r n i n g st ...

  • Xantrex 300 - page 8

    3 Wa rn i n g! Risk of fir e or explos ion. The 300 Inverter contains componen ts that tend to produce arcs or sparks. T o prevent fire or explosion, do not install the inverter in compartments containing b att eries o r flammable materials or in locations that require ignition - protected equipment. Wa rn i n g! Fi re haz ard. T o reduce the risk ...

  • Xantrex 300 - page 9

    4 Caution! Risk of damag e to the 300 Inverter. Reverse battery polarity (negative connected to positive; positive conn ected to negative) will damage the 300 Inverter, and i t will require servicing. Damage caused by reverse polarity is not covered by your warranty . Caution! Ris k of damage to r echargeable appliances. The output of the 300 In ve ...

  • Xantrex 300 - page 10

    5 3 Xantrex 300 Inverter Features This section des cribes the main features of the 300 Inverter. Figure 1 s hows the inver ter ’ s AC pan el . Figure 1 AC Panel on t he 300 Inverte r (European A C Outlet) ➀ AC Outlet An AC outlet is located o n one end of the inverter . It allows yo u t o p lug in a 230 v ol t A C pro duct with a power c onsump ...

  • Xantrex 300 - page 11

    6 When the inver ter is connected to a DC power source and the On/Standby switch i s on, AC power is available at the outlet. ➂ Power Light The green PWR light is on all the time when the On/Standby switch is on. ➃ Fault Li ght The red light indicates that the inverter has sh ut down because of lo w or high battery voltage, AC overload, or exce ...

  • Xantrex 300 - page 12

    7 AC Outlets Depending on your geogr aphic location, you r 300 Inverter will have one of the following AC outlets. Figure 2 European AC Outlet Figure 3 British AC Outlet Figure 4 Australian an d New Zea land AC Outlet ...

  • Xantrex 300 - page 13

    8 4 Connecting the 300 Inverter This secti on explains how t o connect the 300 Inverter. Choosing a Location For the bes t performance, choo se a location that is: • Dry Do not expose the inverter to water drip or spray . • Cool Operate the inverter in a mbient temperatures between 0° C and 40° C (32° F and 1 00° F). Keep it away from heati ...

  • Xantrex 300 - page 14

    9 Connecting t he 300 Inverter to DC Power Y ou can connect the inverter to a 12 volt D C po wer source usin g: • The cigarett e plug wire ass embly ( page 10 ) • The battery clip wire assembly ( page 1 1 ) • A har dwire d conne ction t o the bat tery ( pa ge 13 ) Y our method will depen d on the size of the AC loads you want to po wer . When ...

  • Xantrex 300 - page 15

    10 Usi ng the Ci garett e Plug Wire As sembly Load s unde r 15 0 watts When you are going to p ower loads under 150 watts, use t he cigarette plug w ire assembly . T o connect the inverter: 1. Remove the nuts from the DC terminals on the inverter . 2. Place the red ring co nnector on the inverter ’ s red (posit ive +) DC term inal, and then screw ...

  • Xantrex 300 - page 16

    11 5. T urn on the inverter ’ s On/Standby switch. The PW R li ght comes on, and AC power is available at the outlet. Note: Y ou may need to turn the vehicle’ s ignition key to the accessory p osition. 6. Plug in the AC load you want to opera t e. Using the Battery Clip Wire Assembly Loads gr e ater than 150 watts When you are going to po wer l ...

  • Xantrex 300 - page 17

    12 T o connect the inverter: 1. Remove the nuts from the DC terminals on the inverter . 2. Place the red ring co nnector on the red (pos i tive +) DC terminal, and then screw the red nut on until it is snug. Do not over tighten. 3. Attach the red clip to the red (positive +) battery terminal. 4. Attach the black clip to the black (negative –) bat ...

  • Xantrex 300 - page 18

    13 5. Place the black ring conn ector on the black ( negative –) DC terminal, and then screw the black nut on until it is snug. Do not ov er tigh ten. Note: A spark may occur when you make this connection. Th i s is normal. 6. Check that bo t h clips are securely connected to the battery terminals. A loose connection will cause excessive voltage ...

  • Xantrex 300 - page 19

    14 Figure 6 Hardwiring th e 300 Inve rter to a 12 V olt Battery T o hardwire the inverter to the battery: 1. Cut the clips off the cable clip wire assembly . (The Caution! Fir e hazard. The wires in m ost 12 volt sockets o r power outlets are not larg e enough for loads greater th an 150 watts: they will o verheat an d presen t a fi re hazard. For ...

  • Xantrex 300 - page 20

    15 wires in this assembly ar e appropriate for loads ov er 150 watts. The wires in the cigarette plug wire asse m bly are too small: do not use them.) 2. Us ing 3.3mm 2 (12 A W G ) wire or heavier , extend the power cord if you need to, to a maximum total len gth of 2 meters (6.5 fe et) including the existin g 300 Inverter power cord length. Solder ...

  • Xantrex 300 - page 21

    16 6. Remove the nuts from the DC terminals of the inverter . 7. Place the red ring co nnector on the red (pos i tive +) DC terminal on the inv erter, and then screw the red nut o n until it is snug. Do not over tighten. 8. Fasten the positive terminal (red wire) to th e positi ve batter y post. 9. Fasten the negative terminal (b lack wire) to the ...

  • Xantrex 300 - page 22

    17 Disconnecting th e Batter y • Before you disc onnect the battery , turn off the AC load, and then turn off th e in-line switch. Replacing t he In-Line Fuse • If you n eed to replace the in-line fuse (s ee Figure 6 ), turn off the in-line switch to disconnect the DC power . ...

  • Xantrex 300 - page 23

    18 5 Operating the 300 Inverter This secti on describes no rmal operation as wel l as several problems th at could occur when you use the inverter . If you have a prob lem, see “T roubleshooti ng” on page 22 . Oper ating S tatuse s • Normal Operation When you connect the inverter to your vehi cle’ s 12 volt source and turn on the On/ Standb ...

  • Xantrex 300 - page 24

    19 that occurs whe n the engine starts may trigger a low volta g e shut do wn. • AC Overload Shutdown If you connec t an AC load rated hi gher than 300 wa tts or 1.3 amps or that dra ws excessive sur ge power , the 300 Inverter shuts down. The PWR light stays on, and t he light comes on to indicate that the inver t er is overloaded. Note: High st ...

  • Xantrex 300 - page 25

    20 Interferenc e With Electronic Equipment Most AC products operate with the 300 Inverter as they would wi th household A C power with the fo llowing exceptions. Buzzing Sou nd Some inexpe nsive stereo systems and “boom boxes” have inadequ ate internal power supply filtering and buzz slightly when powered by the 300 I nverter. The best so lutio ...

  • Xantrex 300 - page 26

    21 6 Battery Operating T ime The battery operating time of t he 300 Invert er depends on the char ge level of the battery , battery capacity , and the amou nt of po wer dr a wn by t he par ticul a r AC lo ad. W it h a typical vehicle battery an d a 300 watt load, you ca n expect one or mor e hours of op erating time. T o preserve the batter y: • ...

  • Xantrex 300 - page 27

    22 7 T r oubleshooting This secti on describes pro blems you may encount er , the symptoms of each problem, poss ible causes, and various reme dies. The AC load will not operate; the re d light is on. Sympt om An AC load is plugged in or turned o n, operates for on e to te n se conds , and the n shut s do wn. W arning! Shock Hazard. Do not open the ...

  • Xantrex 300 - page 28

    23 Sympt om The AC load does not operate. The light comes on when the inverter is turned on or wh en the AC load is t urned on or pl ugged in. The alarm may sound. Sympt om The AC load runs for more th an one minute, the alarm sounds , and the light co mes on. The inverter is warm or hot to touch. The alarm may sound. Possible cause Suggested remed ...

  • Xantrex 300 - page 29

    24 The AC load will not operate; no inverter lights are on. Sympt om The cigarette lighter works in the lighter socket, but the inverter does not. Sympt om The cigarette lighter does not work in the lighter socket. Possible cause Suggested remedy The contact between the pl ug and the li ghter socket or th e 12 volt ou tlet is po or . Press the pl u ...

  • Xantrex 300 - page 30

    25 Measured inver ter output voltage is too low . Sympt om The AC voltmeter reading is 5 to 1 5 volts too low . Battery operating time is less than expected. Sympt om The inver ter r uns for a while, and then th e light comes on. The inverter i s cool or warm to touch. Possible cause Suggested remedy A standard “average-reading” AC voltme ter h ...

  • Xantrex 300 - page 31

    26 8 W arranty Information What Does This W arranty Co ver? Xantrex manuf actures its products from parts and components that are new or equivalent to new , in accordance with indu stry standard practices. This warran ty co vers an y d efects in wor kmansh ip or ma t e rials. How Long Does The Cov erage Last? This warranty las t s fo r two (2) year ...

  • Xantrex 300 - page 32

    27 building replacement pro ducts. If Xantrex repairs or replaces a product, its warranty term is not extended. Xantr ex owns all part s removed from repaired produ cts. Service During W a rranty In order to qualify for the warranty , dated pro of of purchase mus t be provided and t he product mu st n ot be di s ass embl ed or mod ified withou t pr ...

  • Xantrex 300 - page 33

    28 Y ou must obtain a Return Material Authorizatio n (RMA) number fro m Xantrex before returning a pro duct directly to Xantre x. Do not return a product to Xant rex without firs t obtai ning an RMA nu mber . Whe n you con tact Xa ntrex t o obtain service, be prepared to supply the serial number of your p roduct and i t s date of purchase as well a ...

  • Xantrex 300 - page 34

    29 T o return your 300 Inverter for out-o f-warranty service, contact Xantrex cust omer service for a Return Mat erial Authorization (RMA) number , and follow the other steps outlined in “T o Xant rex” on pag e 27 . Options for payment, such as credit card or money order , will be ex plained by the customer service r epresentative. In cases whe ...

  • Xantrex 300 - page 35

    30 9 Specifications Specifications may change w ithout notice. Electrica l AC receptacles 1 AC output voltage 230 volts AC RMS ± 5% AC output f requency 50 ± 3 Hz AC output waveform Modifi ed Sine W ave Maximu m continuo us AC output power 300 wat t s Maximu m AC output surge power 600 watts DC in put vol tage ra nge 10–15 v olts DC Battery d r ...

  • Xantrex 300 - page 36

    31 Physical Regulatory Dime ns io n s ( L x W x H) 200m m x 10 3mm x 66mm (7.9 i n. x 4.1 in. x 2 .6 in.) W e ight 0.79 K g (1. 74 lb.) CE Mark Low V oltage Directive EMC Directive e Mark Automotiv e EMC Directive TUV/T ype ap proved Certif ied to EN 60950 ...

  • Xantrex 300 - page 37

    32 ...

Manufacturer Xantrex Category Portable Generator

Documents that we receive from a manufacturer of a Xantrex 300 can be divided into several groups. They are, among others:
- Xantrex technical drawings
- 300 manuals
- Xantrex product data sheets
- information booklets
- or energy labels Xantrex 300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Xantrex 300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Xantrex 300, service manual, brief instructions and user manuals Xantrex 300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Xantrex 300.

Similar manuals

A complete manual for the device Xantrex 300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Xantrex 300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Xantrex 300.

A complete Xantrex manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Xantrex 300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Xantrex 300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Xantrex 300, that we can find in the current document
3. Tips how to use the basic functions of the device Xantrex 300 - which should help us in our first steps of using Xantrex 300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Xantrex 300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Xantrex 300 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Xantrex 300?

Use the form below

If you did not solve your problem by using a manual Xantrex 300, ask a question using the form below. If a user had a similar problem with Xantrex 300 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)