Superior NMC004-TD - page 1
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. HOMEOWNER'S CARE AND OPERA TION INSTRUCTIONS 33" DIRECT-VENT GAS FIREPLACE HEATERS P/N 725,023M REV. J 11/2004 MODELS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin- ity of this or any other ap ...
-
Superior NMC004-TD - page 2
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. These appliances are designed to operate on natural or propane gas only. On Millivolt models the Input of the appliance can be varied from 13,500 to 17,500 BTU/HR. On Electronic models the input is fixed at 17,500 BTU/HR. CONGRATULATIONS! In selecting this SUPERIOR Direct-Vent Gas Appliance you hav ...
-
Superior NMC004-TD - page 3
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 1 Millivolt Appliances - To light millivolt appliances refer to the detailed lighting instructions found in both English and French on pages 12 and 13 of these instruc- tions respectively. Millivolt appliance lighting instructions may also be found on the pull out lighting instruction labels ...
-
Superior NMC004-TD - page 4
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. CAUTION: DO NOT ATTEMPT TO TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE FIREPLACE IS IN USE. Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a ...
-
Superior NMC004-TD - page 5
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Periodically (After the Burning Season) Maintenance Task Accomplishing Person Procedure Cleaning Firebox Interior Check Flame Patterns and Flame Height Checking Vent System Cleaning Front Glass Enclosure Panel Homeowner Homeowner Homeowner Homeowner Carefully remove logs, Rockwool and volcanic ston ...
-
Superior NMC004-TD - page 6
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Refer to Figure 5 and remove the front glass enclosure panel as follows : 1. Remove the top louver or radiant panel. 2. Open the hinged drop-down control com- partment panel. Flame Appearance and Sooting Proper flame appearance is a matter of taste. Generally most people prefer the warm glow of a y ...
-
Superior NMC004-TD - page 7
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Log Placement Figure 8 3 . Insert the alignment hole of the left twig over the front log's left pin. Rotate the left twig until it just touches the edge of the ember bed bracket. 4 . Insert the alignment hole of the right twig over the front log's right pin. Rotate the right twig until it ...
-
Superior NMC004-TD - page 8
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Electronic Appliance Checkout To light the burner, turn ‘ON’ the optional remote wall switch and turn the gas control switch to the “ON” position. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame rod as shown in Figure 11 . Figure 11 With proper care and maintena ...
-
Superior NMC004-TD - page 9
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARRANTY Your gas appliance is covered by a limited twenty year warranty. You will find a copy of the war- ranty accompanying this manual. Please read the warranty to be familiar with its coverage. Retain this manual. File it with your other docu- ments for future reference. REPLACEMENT PARTS A com ...
-
Superior NMC004-TD - page 10
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Remote Control System (Standard) H0249 RCL Standard Remote Control System (Model RCL) The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace. This model includes a hand-held transmitter, a remote receiver with wall-mount coverplate and all h ...
-
Superior NMC004-TD - page 11
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Door Frame Kits - 4 piece (shown) Brass Finish 99L62 DFK-4B Brushed Stainless Finish 99L63 DFK-4BS Door Frame Kits - 2 piece Brass Finish 17M28 DTK-4B Brushed Stainless Finish 17M29 DTK-BS Door Frame Kits Decorative door frame kits are available for use with these appliances. The DFK (four- piece ...
-
Superior NMC004-TD - page 12
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighte ...
-
Superior NMC004-TD - page 13
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé. Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à étincelle (en poussant le bouton) jusqu’à ce que la vei ...
-
Superior NMC004-TD - page 14
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell ne ...
-
Superior NMC004-TD - page 15
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces in- structions. B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez aucune odeur de gaz autour de l? ...
-
Superior NMC004-TD - page 16
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TROUBLESHOOTING THE MILLIVOL T GAS CONTROL SYSTEM 1. Spark ignitor will not light pilot after repeated triggering of ignitor button. 2. Pilot will not stay lit after carefully following the lighting instructions. 3. Pilot burning, no gas to burner, Valve knob “ON,” Wall Switch “ON.” 4. Fre ...
-
Superior NMC004-TD - page 17
17 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION See Below. Disconnect the two black wires from the wire nuts. Test switch(s) for continuity with a multimeter. If continuity is not indicated, switch(s) is defective and must be replaced. Note: Before replacin ...
-
Superior NMC004-TD - page 18
18 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. REPLACEMENT PARTS LIST Natural Propane No. DESCRIPTION Part No. Qty. Part No. Qty. Gas Fireplace Assembly – – – – 1. Hood LB-91941FZ 1 LB-91941FZ 1 2. Louver LB-92400F 7 LB-92400F 7 3. Louver, (Base) LB-92402F 1 LB-92402F 1 4. Enclosure, Glass Front (Complete) LB-92534H 1 LB-92534H 1 5. Na ...
-
Superior NMC004-TD - page 19
19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. REPLACEMENT PARTS 9 4 1 2 5 14 6 3 2 11 10 13 8 15 7 41 40 21 43 23 22 24 42 26 25 30 31 32 33 34 35 36 27 37 20 12 44 16 ...
-
Superior NMC004-TD - page 20
20 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2002 by LENNOX HEARTH PRODUCTS P/N 725,023M REV. J 11/2004 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fire ...
Do you have a question concerning Superior NMC004-TD?
Use the form below
If you did not solve your problem by using a manual Superior NMC004-TD, ask a question using the form below. If a user had a similar problem with Superior NMC004-TD it is likely that he will want to share the way to solve it.