    Fieldbus FBUS-HSE/H1 Linking Device (LD) User Manual FBUS-HSE/H1 LD User Manual May 2003 Edition Part Number 3707 28A-01 ...

  • National Instruments Fieldbus - page 2

    Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599, Canada (Calgary) 403 274 9391, Canada (M ...

  • National Instruments Fieldbus - page 3

    Important Information Warranty The FBUS-HSE/H 1 Linking Device (LD) is wa rranted agai nst defects in materials and w orkmanshi p for a perio d of one year f rom the date of shipment, as evidenc ed by receipts or othe r documentation. Nati onal Instruments will, at its opt ion, repair or replace equipmen t that proves to be defective durin g the wa ...

  • National Instruments Fieldbus - page 4

    Compliance FCC/Canada Radio Frequency Interference Compliance Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless co mmunications from inte rference. The FCC places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations onl y) or Class B (for u ...

  • National Instruments Fieldbus - page 5

    © National Instruments Corporat ion v FBUS-HSE/H1 LD User Manual Contents About This Manual How To Use the Manual Set ............ ............ ........... .............. ........... .............. ............ .... vii Conventions ............ ........... .............. ............ .............. ........... ........... .............. .......... ...

  • National Instruments Fieldbus - page 6

    Contents FBUS-HSE/H1 LD User Manua l vi ni.com Appendix D Technical Support and Professional Services Glossary Index ...

  • National Instruments Fieldbus - page 7

    © National Instruments Corporatio n vii FBUS-HSE/H1 LD User Manual About This Manual This manual describes the mechani cal and electrical aspects of the FBUS-HSE/H1 Linking Device (LD) and contains information con cerning its installation and operat ion. The FBUS-HSE/H1 LD product is a High Speed Ethernet to Foundatio n H1 Linking Device. How T o ...

  • National Instruments Fieldbus - page 8

    About This Manual FBUS-HSE/H1 LD User Manua l viii ni.com programs, subprograms, su broutines, d evice names, functions, operations, variables, filenames and e xtensions, and code excerpts. Related Documentation The following documents contain information you migh t find helpful as you read this manual: • Foundation Fieldbus Specification : Syste ...

  • National Instruments Fieldbus - page 9

    © National Instruments Corporatio n 1-1 FBUS-HSE/H1 LD User Manual 1 Over view of FBUS-HSE/H1 Linking Device (LD) Hardware This chapter provides an overview of the FBUS -HSE/H1 Linking Device (LD) hardware. Product Over view High Speed Ethernet (HSE) is an extension to the Foundatio n Fieldbus specification and is governed by the Foundation Fieldb ...

  • National Instruments Fieldbus - page 10

    Chapter 1 Overview of FBU S-HSE/H 1 Li nking Devic e (LD) H ardware FBUS-HSE/H1 LD User Manua l 1-2 ni.com Figure 1-1 shows an FB US-HSE/H1 LD connected to an Ethernet network. Figure 1-1. T y pical Ethernet Network Setup In a distributed application, many Fieldb us H1 segments are network ed together using HSE LDs. With Ethernet, you can use an un ...

  • National Instruments Fieldbus - page 11

    Chapter 1 Overview of FBUS-HSE/H 1 Linking Devi ce (LD) Hardware © National Instruments Corporatio n 1-3 FBUS-HSE/H1 LD User Manual Once configured, the linking de vice permits HMI software on any PC connected to an FBUS-HSE/H1 LD to access and monitor Fieldb us devices as if the HMI were directly conn ected to the Fieldbus network. System Require ...

  • National Instruments Fieldbus - page 12

    © National Instruments Corporatio n 2-1 FBUS-HSE/H1 LD User Manual 2 Hardware Installation and Configuration Installing the FBUS-HSE/H1 LD The FBUS-HSE/H1 LD has a simple rai l clip for reliable mounting o nto a standard 35 mm DIN rail. Complet e the follo wing steps to mount the FBUS-HSE/H1 LD on a DIN rail. 1. Use a flathead scre wdriv er to ope ...

  • National Instruments Fieldbus - page 13

    Chapter 2 Hardware Installa tion and Configuration FBUS-HSE/H1 LD User Manua l 2-2 ni.com Figure 2-2. Mounting the FBUS-HSE/H1 LD on a DIN Rail 3. Slide the FBUS-HSE/H1 LD to the de sired position alon g the DIN rail. After the FBUS-HSE/H1 LD is in position, lock it to the DIN rail by pushing the rail clip to the locked positio n, as shown in Figur ...

  • National Instruments Fieldbus - page 14

    Chapter 2 Hardware Installa tion and Configuration © National Instruments Corporatio n 2-3 FBUS-HSE/H1 LD User Manual Mounting the FBUS-HSE /H1 LD to a Panel Complete the followin g steps to install the optional Fi eldbus network panel mount accessory and mount the FBUS -HSE/H1 LD network module to a panel. You can order the panel mount accessory ...

  • National Instruments Fieldbus - page 15

    Chapter 2 Hardware Installa tion and Configuration FBUS-HSE/H1 LD User Manua l 2-4 ni.com Connect Y our FBUS-HSE/H1 LD to the Network Connect the RJ-45 Ethernet port of th e FBUS-HSE/H1 LD to an Ethernet hub using a standard Category 5 Ethern et cable. You also can connect an FBUS-HSE/H1 LD directly to a comp uter using an Ethernet crossover cable. ...

  • National Instruments Fieldbus - page 16

    Chapter 2 Hardware Installa tion and Configuration © National Instruments Corporatio n 2-5 FBUS-HSE/H1 LD User Manual Cabling If you build your own cables, the following table shows the st andard Ethernet cable wiring connections for both normal and crossover cables. Figure 2-5 shows the connector pinouts for Fieldbus Ethernet cables. Figure 2-5. ...

  • National Instruments Fieldbus - page 17

    Chapter 2 Hardware Installa tion and Configuration FBUS-HSE/H1 LD User Manua l 2-6 ni.com Connect the FBUS-HSE/H1 LD to the Fieldbus Network The FBUS-HSE /H1 LD ca n be one of up to 32 devices connected to a Fieldbus H1 network. The connecti on is made thro ugh one of the two 9-pin male D-sub Fieldbus H1 connectors on the FBUS-HSE/H 1 LD, shown in ...

  • National Instruments Fieldbus - page 18

    Chapter 2 Hardware Installa tion and Configuration © National Instruments Corporatio n 2-7 FBUS-HSE/H1 LD User Manual Connect Power to the FBUS-HSE/H1 LD Each FBUS-HSE/H1 LD on your network requires an 11-30 VDC power supply. The po wer connector is a 6-pin scre w terminal power connector whose pinout is shown in Figure 2-7. Figure 2-7. FBUS-HSE/H ...

  • National Instruments Fieldbus - page 19

    © National Instruments Corporatio n A-1 FBUS-HSE/H1 LD User Manual A Resetting the FBUS-HSE/H1 LD If the FBUS-HSE/H1 LD cannot communicate with the network, you can configure the Ethernet settings through NI-FBUS software. When you configure the de vice, it attempts to confirm that the ne w settings are valid. Ho wever , if the configuration proce ...

  • National Instruments Fieldbus - page 20

    Appendix A Resetting the FBUS-HSE/H1 LD FBUS-HSE/H1 LD User Manua l A-2 ni.com Figure A-1. FBUS-HSE/H1 LD Reset Switch 3. Looking at the FBUS-HSE/H1 LD so that the label is upright, as shown in Figure A-1, use a pen or a smal l screwdr i ver to mov e the Reset switch to the right. 4. Power up the FBUS-HSE/H1 L D and wait for the re d STATUS LED to ...

  • National Instruments Fieldbus - page 21

    © National Instruments Corporatio n B-1 FBUS-HSE/H1 LD User Manual B T roubleshooting LED Indicators Hardware The FBUS-HSE/H1 LD has sev en LED indicators on the top panel and three LEDs on the front panel, as sho wn in Figure B-1. ...

  • National Instruments Fieldbus - page 22

    Appendix B T roubleshooting FBUS-HSE/H1 LD User Manua l B-2 ni.com Figure B-1. LEDs on the FBUS-HSE/H1 LD Ethernet LEDs The six Ethernet LEDs are locat ed on the top panel. The green POWER LED is lit while the FBUS-HSE/H1 LD is powered up. This LED indicates th at the po wer supply connected to the FBUS-HSE/H1 LD is acceptable. 1 H1 Port1 Network S ...

  • National Instruments Fieldbus - page 23

    Appendix B T roubleshooting © National Instruments Corporatio n B-3 FBUS-HSE/H1 LD User Manual Caution Do not power do wn the FBUS-HSE/H1 LD while the PROCESS LED is lit. The green PROCESS LED is lit when you update the non v olatile flash memory of the FBUS-HSE/H1 LD. If you want to change network settings, sav e channel settings or power -up val ...

  • National Instruments Fieldbus - page 24

    Appendix B T roubleshooting FBUS-HSE/H1 LD User Manua l B-4 ni.com Module ST A TUS LED The module STATUS LED is located on the front of the linking device, between the two Fieldbus (H1 Network) connectors, as sho wn in Figure B-1. It indicates whether the linking device is powered, conf igured, and operating properly . T able B-2 shows ho w to inte ...

  • National Instruments Fieldbus - page 25

    Appendix B T roubleshooting © National Instruments Corporatio n B-5 FBUS-HSE/H1 LD User Manual Standby state indicates the linking device has passed all self tests and is ready to operate. Howe ver , it is not functioning because no acti ve Ethernet segment is conf igured. Operational state indicates the linking de vice has left standby state beca ...

  • National Instruments Fieldbus - page 26

    © National Instruments Corporatio n C-1 FBUS-HSE/H1 LD User Manual C Specifications This appendix describes the specifications of the FBUS-HSE/H1 LD. Network Network interface ....................... ........... . 10BaseT and 100BaseTX Ethernet Device interface ........ .............. ............... Found ation Fieldbus H1 Compatibility ...... .. ...

  • National Instruments Fieldbus - page 27

    Appendix C Specifications FBUS-HSE/H1 LD User Manua l C-2 ni.com Safety This product is designed to meet the requirements of the following standards for safety and electrical equi pment for measurement, control, and laboratory use: • IEC 60950, EN 60950 • UL 1950, UL 60950 • CAN/CSA C22.2 No. 60950 Note For UL and other safety certifications ...

  • National Instruments Fieldbus - page 28

    © National Instruments Corporatio n D-1 FBUS-HSE/H1 LD User Manual D T echnical Support and Professional Ser vices Visit the following sections of the National Instruments Web site at ni.com for technical support an d professional services: • Support —Online technical support resources include the following: – Self-Help Resources —For imme ...

  • National Instruments Fieldbus - page 29

    Appendix D T echnical Su pport and Professio nal Ser vices FBUS-HSE/H1 LD User Manua l D-2 ni.com • Calibration Certificate —If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration . If you searched ni.com and could not find the answers you need, contact your local off ice or NI co ...

  • National Instruments Fieldbus - page 30

    © National Instruments Corporatio n G-1 FBUS-HSE/H1 LD User Manual Glossar y Symbol Pref ix V alue m milli 10 –3 k kilo 10 3 Mm e g a 1 0 6 A A Amperes. A/D Analog-to-dig ital con verter Al arm. A notification the NI-FBUS Communications Manager software sends when it detects that a block leav es or returns to a particular state. address characte ...

  • National Instruments Fieldbus - page 31

    Glossary FBUS-HSE/H1 LD User Manua l G-2 ni.com Boolean Logical relational system having two v alues, each the opposite of the other , such as true and false or zero and one. bps Bits per second. buf fer T emporary storage for acquired or generated data. bus The group of conductors that interconnect individual circuitry in a computer . T ypi cally ...

  • National Instruments Fieldbus - page 32

    Glossary © National Instruments Corporatio n G-3 FBUS-HSE/H1 LD User Manual device tag A name you assign to a Fieldbus de vice. DI Discrete input. digital Pertaining to data (signals) in the form of discrete (separate/pulse fo rm) integral v alues. directory A structure for organizing f iles in to con venient groups. A directory is like an address ...

  • National Instruments Fieldbus - page 33

    Glossary FBUS-HSE/H1 LD User Manua l G-4 ni.com Fieldbus network address Location of a board or device on the Fieldb us; theFieldbus node address. Foundation Fieldbus specification Communications network specifica tion created b y the Fieldbus Foundation. G ground An intentional or accidental conduc ting path between an electrical system or circuit ...

  • National Instruments Fieldbus - page 34

    Glossary © National Instruments Corporatio n G-5 FBUS-HSE/H1 LD User Manual L LAS See Link Ac t ive Sc h e du l e r . LD Linking device. LED Light-emitting diode. link A Foundation Fieldbus network is made up of devices connected by a serial bus. This serial b us is called a link. Also kno wn as a segment. Link Activ e Scheduler Fieldbus de vice c ...

  • National Instruments Fieldbus - page 35

    Glossary FBUS-HSE/H1 LD User Manua l G-6 ni.com node Junction or branch point in a circuit. non-volatile memory Memory that does not require electricity to hold data. O object An element of an object dictionary . P parameter One of a set of network-visibl e v alues that makes up a function block. PC Personal computer . polarity T erm used to descri ...

  • National Instruments Fieldbus - page 36

    Glossary © National Instruments Corporatio n G-7 FBUS-HSE/H1 LD User Manual sensor A de vice that responds to a physical stimulus (heat, light, sound, pressure, motion, flow , and so on), and produ ces a corresponding electrical signal. server Devic e that recei ves a me ssage request. service A service allo ws user applicatio ns to send messages ...

  • National Instruments Fieldbus - page 37

    Glossary FBUS-HSE/H1 LD User Manua l G-8 ni.com W W aveform Multiple v oltage readings taken at a specific sampling rate. ...

  • National Instruments Fieldbus - page 38

    © National Instruments Corporatio n I-1 FBUS-HSE/H1 LD User Manual Index C cables, 2-5 calibration certificate, D-2 CE compliance, C-2 compatibility informat ion, 1-3 configuration and monitoring, 1-2 connecting to the Fieldbus network, 2-6 connector pinout (figure), 2-6 contacting National In struments, D-2 conventions used in the manual, vii cus ...

  • National Instruments Fieldbus - page 39

    Index FBUS-HSE/H1 LD User Manua l I-2 ni.com LEDs Ethernet LEDs, B-5 Ethernet STATUS LED flashes and corresponding erro rs (table), B-4 figure, B-2 H1 network status LEDs (table), B-5 module STATUS LED (table), B-4 troubleshooting, B-1 mounting on a DIN rail (figure), 2-2 mounting to a panel, 2-3 overview, 1-1 power connection, 2-7 pinout (figure), ...

  • National Instruments Fieldbus - page 40

    Index © National Instruments Corporatio n I-3 FBUS-HSE/H1 LD User Manual L LEDs Ethernet LEDs, B-2 figure, B-2 H1 network status LEDs (table), B-5 module STATUS LED (table), B-4 on top panel (figure), B-1 POWER, 2-7 troubleshooting, B-1 M mechanical dimensions, C-1 module STATUS LED, B-4 N National Instruments calibration certificate, D-2 customer ...

  • National Instruments Fieldbus - page 41

    Index FBUS-HSE/H1 LD User Manua l I-4 ni.com W Web professional services, D-1 technical support, D-1 worldwide technical support, D-2 ...

Manufacturer National Instruments Category Network Card

Documents that we receive from a manufacturer of a National Instruments Fieldbus can be divided into several groups. They are, among others:
- National Instruments technical drawings
- Fieldbus manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments Fieldbus
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments Fieldbus.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments Fieldbus, service manual, brief instructions and user manuals National Instruments Fieldbus. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments Fieldbus.

A complete manual for the device National Instruments Fieldbus, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments Fieldbus by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments Fieldbus.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments Fieldbus - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments Fieldbus, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments Fieldbus, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments Fieldbus - which should help us in our first steps of using National Instruments Fieldbus
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments Fieldbus
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments Fieldbus in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments Fieldbus?

Use the form below

If you did not solve your problem by using a manual National Instruments Fieldbus, ask a question using the form below. If a user had a similar problem with National Instruments Fieldbus it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)