Summary
  • Liebert PS250-50S, PS400-50S, PS600-50S - page 1

    PowerSure™ POWER PROTECTION Uninterruptible Power System 250 VA – 600 VA 230 VAC USER’S MANUAL R PS250-50 S 250 V A PS400-50 S 400 V A PS600-50 S 600 V A ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 2

    2 IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or removing the cov er may expose you to dangerous voltages, even when the AC cord is disconnected from the electrical outlet. Refer all servicing to qualified service personnel. 1. SAVE THESE INSTRUCTIONS. ADHERE TO ALL O ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 3

    3 1. ON/OFF Button 2. Battery Light (400/600 Only ) 3. Check Light (400/600 Only) 4. AC Light 5. Battery Test Button (400/600 Only) 6. Option Switches 7. Output Receptacles 8. Power Cord Input 9. Circuit Breaker 10. Communications Port ATTENTION: Please refer to these drawings when reading this manual. This manual references t he various parts of y ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 4

    4 5. After charging, shutdown both the UPS and load equipment and unplug them fro m the AC supply socket. Connect the supplied CEE - 22 output cable (B) between the load equipment input socket (D) and one of the UPS AC output sockets (E). Connect all load equipment to UPS in this way. 6. When all equipment is plugged in, plug UPS into the A C suppl ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 5

    5 COMPUTER/LAN INTERFACE (400/600 VA ONLY) Optional SiteNet 1 kits provide connection to a wide range of popular computer operating systems; such as No vell, UNIX, UNISYS, SUN, WINDOWS and many others. SiteNet 1 software automatically performs an orderly shutdown of computer operating systems, in the event of a power outage and/or low battery condi ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 6

    6 Option Switch 3 & 4: Low Voltage Limit Select – Low voltage limit is the voltage level at which battery operation starts. You may set the low voltage limit of the UPS to 180V, 190V, or 200V. The factory setting is 190V. This option reduces excessive battery usage in brownout cond itions. Make sure your computer equipment can operate at 180 ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 7

    7 To Replace the Battery: 1. Close active programs and turn off computers. Turn OFF the UPS and unplug it from mains supply. 2. Place UPS on its side and remove retaining screws (A) to battery door (B). 3. Ope n battery door (B) and remove the battery (C) by pulling on the battery tab (D). 4. Remove terminal wires (E) from old battery. Connect term ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 8

    8 PROBLEM CAUSE SOLUTION UPS will not start Input voltage be low threshold Overload/Short Circuit Input frequency mis - match with option switch setting Mains overvoltage Wait until mains voltage rises to appropriate level. Check circuit breaker at rear of UPS (9). If it is activated, reset it and restart the UPS (See "Resetting Circuit Breake ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 9

    9 250 VA LED & ALARM INDICATIONS Condition Green AC Light (4) Audible Alarm Status NORMAL/START UP On after Beep Single Beep, then Off Operate Start - Up Test Fail On after Beep Fast Beep for 15 Sec and then Off Operate Input Frequ ency Mismatch with Option Switch Setting Input Voltage Below Threshold Off Continuous Will Not Start Overload/Shor ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 10

    10 SPECIFICATIONS Model # / Stock # PS250 - 50/PS250 - 50S PS400 - 50 / PS400 - 50S PS600 - 50 / PS600 - 50S Model Rating 25 0 VA / 150 W 400 VA / 240 W 600 VA / 360 W Dimensions: mm Unit (W x D x H) 90 x 262 x 175 109 x 262 x 186 124 x 262 x 216 Shipping (W x D x H) 181 x 365 x 303 212 x 482 x 292 237 x 482 x 334 Weight: Kg Unit 4 5.7 9 Shipping 4 ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 11

    11 LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaser and to its customer (collectively referred to as the "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal use, service, and maintenance FOR A PERIOD OF TWO ...

  • Liebert PS250-50S, PS400-50S, PS600-50S - page 12

    12 1050 Dearborn Drive Co lumbus, OH 43229 614 - 888 - 0246 Technical Support U.S.A................................................................ 1 - 800 - 222 - 5877 Outside the U.S.A ........................................... 614 - 841 - 6755 U.K...................................... .......................... +44 (0) 1793 553355 France ...... ...

Manufacturer Liebert Category Power Supply

Documents that we receive from a manufacturer of a Liebert PS250-50S, PS400-50S, PS600-50S can be divided into several groups. They are, among others:
- Liebert technical drawings
- PS250-50S, PS400-50S, PS600-50S manuals
- Liebert product data sheets
- information booklets
- or energy labels Liebert PS250-50S, PS400-50S, PS600-50S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Liebert PS250-50S, PS400-50S, PS600-50S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Liebert PS250-50S, PS400-50S, PS600-50S, service manual, brief instructions and user manuals Liebert PS250-50S, PS400-50S, PS600-50S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Liebert PS250-50S, PS400-50S, PS600-50S.

Similar manuals

A complete manual for the device Liebert PS250-50S, PS400-50S, PS600-50S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Liebert PS250-50S, PS400-50S, PS600-50S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Liebert PS250-50S, PS400-50S, PS600-50S.

A complete Liebert manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Liebert PS250-50S, PS400-50S, PS600-50S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Liebert PS250-50S, PS400-50S, PS600-50S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Liebert PS250-50S, PS400-50S, PS600-50S, that we can find in the current document
3. Tips how to use the basic functions of the device Liebert PS250-50S, PS400-50S, PS600-50S - which should help us in our first steps of using Liebert PS250-50S, PS400-50S, PS600-50S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Liebert PS250-50S, PS400-50S, PS600-50S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Liebert PS250-50S, PS400-50S, PS600-50S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Liebert PS250-50S, PS400-50S, PS600-50S?

Use the form below

If you did not solve your problem by using a manual Liebert PS250-50S, PS400-50S, PS600-50S, ask a question using the form below. If a user had a similar problem with Liebert PS250-50S, PS400-50S, PS600-50S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)