    TELESCOPING POLE SA W Model 96405 SET UP AND OPERA TING INSTRUCTIONS Diagrams within this manual are not drawn proportionally . Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material bef ...

  • Chicago Electric 96405 - page 2

    Page 2 SKU 96405 For technical questions, please call 1-800-444-3353. CONTENTS IMPORT ANT SAFETY INFORMA TION ............................ 3 GENERAL SAFETY RULES ................................................. 3 Work Area ................................................................................... 3 Electrical Safety ...................... ...

  • Chicago Electric 96405 - page 3

    Page 3 SKU 96405 For technical questions, please call 1-800-444-3353. SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product ha ...

  • Chicago Electric 96405 - page 4

    Page 4 SKU 96405 For technical questions, please call 1-800-444-3353. GENERAL SAFETY RULES W ARNING! Read all instructions Failure to follow all instructions listed below may result in electric shock, re, and/or serious injury . The term “power tool” in all of the warnings listed below refers to your mains-operated (corded) power tool. SA VE ...

  • Chicago Electric 96405 - page 5

    Page 5 SKU 96405 For technical questions, please call 1-800-444-3353. Avoid accidental starting. Ensure the switch is in the “OFF” position before plugging in. Carrying power tools with your nger on the switch or plugging in power tools that have the switch on invites accidents. Remove any adjusting key or wrench before turning the power too ...

  • Chicago Electric 96405 - page 6

    Page 6 SKU 96405 For technical questions, please call 1-800-444-3353. Service Have your power tool serviced by a qualied repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained . SPECIFIC SAFETY RULES Only use the Pole Saw to cut wood. Never attempt to cut masonry , metal or any othe ...

  • Chicago Electric 96405 - page 7

    Page 7 SKU 96405 For technical questions, please call 1-800-444-3353. pacemaker failure. People with pacemakers should consult their physician(s) for advice. Some dust created by power sanding, sawing, grinding, drilling, and other construction activities, contains chemicals known [to the State of California] to cause cancer , birth defects or othe ...

  • Chicago Electric 96405 - page 8

    Page 8 SKU 96405 For technical questions, please call 1-800-444-3353. understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator . SA VE THESE INSTRUCTIONS. GROUNDING Improperly connecting the grounding wire can result in electric shock. Check with a qualied ...

  • Chicago Electric 96405 - page 9

    Page 9 SKU 96405 For technical questions, please call 1-800-444-3353. Double Insulated T ools: T ools with T wo Prong Plugs T ools marked “Double Insulated” do not require grounding. They have a special double insulation system which satises OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the ...

  • Chicago Electric 96405 - page 10

    Page 10 SKU 96405 For technical questions, please call 1-800-444-3353. RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25 Feet 50 Feet 75 Feet 100 Feet 150 Feet 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 – ...

  • Chicago Electric 96405 - page 11

    Page 1 1 SKU 96405 For technical questions, please call 1-800-444-3353. SPECIFICA TIONS Electrical Requirements 120 V~ / 60 Hz Motor No Load Amperage 3.5<->4.0 AMPS Blade 8” (Cutting Capacity = 6.7”) Chain Speed 3149 Feet Per Minute Chain Specs Pitch: 3/8” Gauge” 0.043” Center Links 33 Oil Capacity 5.07 Ounces Cord Information 17-5/ ...

  • Chicago Electric 96405 - page 12

    Page 12 SKU 96405 For technical questions, please call 1-800-444-3353. Always turn the Power Switch of the Pole Saw to the “OFF” position, unplug it from the outlet, and allow it to cool down completely before adding oil. T o ll the Oil T ank (42), remove the Oil Cap (41) and add up to 5 Ounces of high- quality chain saw oil. Replace Oil Cap ...

  • Chicago Electric 96405 - page 13

    Page 13 SKU 96405 For technical questions, please call 1-800-444-3353. OPERA TING INSTRUCTIONS Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. General operating instructions T urn the Power Switch of the tool to the “OFF” po ...

  • Chicago Electric 96405 - page 14

    Page 14 SKU 96405 For technical questions, please call 1-800-444-3353. IMPORT ANT : After running the Pole Saw for an extended period of time, allow the Engine to idle for several minutes to dissipate heat. This will prevent the Pole Saw from being damaged by overheating. T o prevent accidents, turn of f the tool and disconnect from the power suppl ...

  • Chicago Electric 96405 - page 15

    Page 15 SKU 96405 For technical questions, please call 1-800-444-3353. MAINTENANCE AND SERVICING Risk of serious personal injury from accidental starting or electric shock. T urn the Power Switch of the tool to its “OFF” position and unplug the tool from its electrical outlet before performing any inspection, maintenance, or cleaning procedures ...

  • Chicago Electric 96405 - page 16

    Page 16 SKU 96405 For technical questions, please call 1-800-444-3353. Problem Possible Causes Probable Solutions Pole Saw runs slowly and stalls easily Power supply receiving low voltage. 1. Extension cord wire size is too small. 1. Pole Saw does not run when Power Switch is depressed. Safety Switch not depressed enough to release Power Switch. Ex ...

  • Chicago Electric 96405 - page 17

    Page 17 SKU 96405 For technical questions, please call 1-800-444-3353. Part Description 1 Screw ST 4x18 2 Plastic End Cap 3 Screw M5x58 4 Spring W asher 5 W asher 8x4.2x0.6 6 Carbon Brush Housing 7 Carbon Brush 8 Nut M4 9 Motor Housing 10 Stator 1 1 Plastic Plate 12 Rotor Assembly 13 Screw M4x65 14 Key 15 Gear Box Housing 16 Gleason Gear 17 Strain ...

  • Chicago Electric 96405 - page 18

    Page 18 SKU 96405 For technical questions, please call 1-800-444-3353. ASSEMBL Y DIAGRAM ...

  • Chicago Electric 96405 - page 19

    Page 19 SKU 96405 For technical questions, please call 1-800-444-3353. LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this prod - uct is free from defects in materials and workmanship for the period of 90 days ...

Manufacturer Chicago Electric Category Pole Saw

Documents that we receive from a manufacturer of a Chicago Electric 96405 can be divided into several groups. They are, among others:
- Chicago Electric technical drawings
- 96405 manuals
- Chicago Electric product data sheets
- information booklets
- or energy labels Chicago Electric 96405
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chicago Electric 96405.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chicago Electric 96405, service manual, brief instructions and user manuals Chicago Electric 96405. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chicago Electric 96405.

A complete manual for the device Chicago Electric 96405, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chicago Electric 96405 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chicago Electric 96405.

A complete Chicago Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chicago Electric 96405 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chicago Electric 96405, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chicago Electric 96405, that we can find in the current document
3. Tips how to use the basic functions of the device Chicago Electric 96405 - which should help us in our first steps of using Chicago Electric 96405
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chicago Electric 96405
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chicago Electric 96405 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chicago Electric 96405?

Use the form below

If you did not solve your problem by using a manual Chicago Electric 96405, ask a question using the form below. If a user had a similar problem with Chicago Electric 96405 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)