Manual IMC Networks iMcV-Giga-FiberLinX-II

60 pages 0.96 mb
Download

Go to site of 60

Summary
  • IMC Networks iMcV-Giga-FiberLinX-II - page 1

    iMcV-Giga-FiberLinX-II Operation Manual ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 2

    FCC Radio Frequency Interference Statement This equipment has been tested and found to comp ly with the limi ts for a Class B computi ng device, pursuant to Part 15 of the F CC Rules. These limits are designed to provide reasona ble protection agains t har mful interferenc e when the equi pment is operated in a com merc ial environment. This eq uip ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 3

    Table of Content s FCC Radio Frequency Interference Stateme nt ------------------------------------------------ ii Warranty ---------------------------------------------------------------------------------------------- ii I - About the iMcV- Giga-FiberLi nX-II ------------------------------------------------------------ 1 Overvi ew ---------------- ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 4

    iv Transparent with Extra Ta gging (Q-in-Q) -------------------------------------------------- 34 Port VLAN --------------------------------------------------------------------------------------- 36 Port VLAN Filt er -------------------------------------------------------------------------------- 40 IX - Trou bleshootin g -------------------------- ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 5

    1 I - About the iMcV-Giga-FiberLinX-II Overview The iMcV-Gi ga-FiberLin X-II ™ allows net work ope rators to d eploy mana ged Ethernet services, with a full range of remote ma nagement, traffic monitorin g, and alarm reporting features. This unit conver ts 1000 Mb ps fiber to 10/1 00/1000 Mbps copper. In addition, a range of fiber connec tors (SC ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 6

    2 The iMcV-Gi ga-FiberLin X-II module is a double-slot, chassis-mounted module. Compatible chassis in clude the following: • iMediaChassis series • MediaChassis series Port Interfaces Every iMcV-Giga-FiberLinX-II includes the following port: • A 10/100/1000 twist ed pair port (EXT MGMT) for management One of the following uplink ports: • On ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 7

    3 2 iView Manage ment Software iView² is the IMC Ne tworks manag ement so ftware designed s pecifically for the IMC Networks “ iMcV” fa mily of mo dules. It f e atures a graphical user in terface (GUI) and gives network mana gers the ability to monitor and control the manageable IM C Networks p roducts. iView 2 is available in several versions ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 8

    4 About Dynamic Host Co ntrol Protocol (DHCP) The iMcV-Giga- FiberLinX-II module includes a Dynami c Host Control Protocol d use that (DHCP) client. By default, the DHCP clie n t is disabled. When a DHCP server is enabled on th e network, th e DHCP client will initiate a dialogue wit h the server during th e boot up s equence . The ser ver will th ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 9

    5 II - LED Oper ation The following are iMcV-Giga- FiberLinX-II diagn ostic LEDs. In this example, the functio ns for a 1x 9 fiber port versi on (SC fi ber) are shown below. NOTE In the SFP/SFP version the LNK/ACT and FDX/COL LEDs replace EXT 1000 and DATA 1000 for the top SFP, which does not h ave built-in LEDs like th e RJ-45 DATA port. In additi ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 10

    6 III - Hardware Configuration Before installing the module in a chassis, there are two features that must be selected using the DI P switch es. The se se lections are: • Enable or disable man agemen t on each port (DIP switches 1, 2, and 3 ) • Confi gure the mod ule as a standa lone, a host, or a remote (DIP switches 7 and 8) DIP Switch Settin ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 11

    7 queried by SNMP. As a Remote unit, the iMc V-Giga-FiberLinX-II will respond to requests for managemen t informatio n from an attached Host unit. The iMcV-Giga- FiberLinX-II default configuratio n is as a Standalone unit (DIP switches 7 and 8 = OFF) . Manage ment Althoug h the iMc V-Giga -FiberL inX-II provides a twisted pair port solel y for mana ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 12

    8 IV - Installation Instructions Each iMcV-Giga -FiberLinX-II module requir es two slots in an iMediaChas sis or MediaChassis. To install the modul e in a chassis, remove the blank faceplates covering th e slots wher e you w ant to install the modul e. Then sl ide the module into the chassis c ard guides until the m odule is seat ed securely in the ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 13

    9 Assigning IP Information When the iMcV -Giga-FiberLinX-II is install e d in an iM ediaChassis, you can use UMA to manag e your iMcV-Giga- FiberLin X-II withou t an IP ad dress (ref er to the i View² online help for more information on UMA). When the iMc V-Giga-FiberLin X-II is not installed in an iMediaChassis, SNM P-manag ement is not acc essib ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 14

    10 Advertising, ra ther than Forc e Mode, when con necting to devi ces that only use autonegotiation. Refer to Port Configuration on page 19 for mo re info rmatio n. Bandwidt h Control The iMcV-G iga-FiberLin X-II includes bi- directiona l bandwi dth control in increments o f 244 Kbps per secon d at gigabit speed (configurable vi a iView 2 ). This ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 15

    11 FiberAlert FiberAler t minimize s the proble ms associate d with the loss of one stran d of fiber. Normally when a single strand of fiber is lost, the transmitting side of the connection is unaware that there i s a fault. Fib erAlert retur ns faults bac k on the fiber they ca me in on. Using Li nkLoss a nd FiberAl ert In a typica l central site ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 16

    12 Loopback Testing on Remote or Standalone The following fu nctions are avail able during loopba ck testing. During l oopback testing, management traffic entering the upli nk port is still capable of managing the device. Address Swap A Laye r 2 Ethe rnet s witch w ill disc ard all rece ived packe ts with the s ame MAC address as sent packet s. To ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 17

    13 VI - Using Telnet You mu st assi gn the iMcV-Gi ga-Fibe rLinX -II an IP addres s before using a Telnet session (this is not necessary when you are usin g UMA). Refer to the Assignin g IP Information section for more inform ation. All of the configurations that you ca n perform from th e serial port can also be perfor med using a Telnet session. ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 18

    14 Basic Device Configuration After r unning thro ugh an initia l self test, the prompt: “Pre ss <Enter> for Device Configuration” displays. Pre ss Enter to open th e Main Configurati on screen: Saved Values. <These values will be active after reboot > IP Address - 10.10.10.10 DHCP is not active Subnet Mask - 255.0.0.0 Default Gatew ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 19

    15 NOTE After making any modificatio ns to the Saved V alues, reboot the unit for your changes to take effect. To reboot, type the word rebo ot at the prompt on the Main Configuration screen. (I) - Assigning IP Informat ion Press I to modify the Sav ed Paramet er Values (i.e., assi gn the IP addr ess and su bnet mask). You will be prompte d to ente ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 20

    16 (T) - Assigning SNMP Trap De stinations Traps are s ent by the man ageable d evice to a managemen t PC when a certain ev ent takes p lace. To enter a t rap dest inat ion, pre ss T . At the prompt , “Enter a New IP Address, ” type the IP address of the d estination device, an d then pr ess Enter . Next, type the name of the community string ( ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 21

    17 (U) - Deleting All SNMP Community Strings To delete all community strings and start over, press U . You will then be prompted, “Are you sure you wa nt to delet e all comm unity s tring s?” Pre ss Y to proceed, N to abort. Press Enter to finish. This function will delete all community strings. If you want to be able to selectively delete comm ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 22

    18 Command Description See Page ifsta ts Displays interface s tatistics. rmstats Displays RMON statistics. version Displays the fi rmware and hardware ve rsion infor mati on. reboot Reboots the unit. secur ity Allows non- standard network con figuratio n. port Display/configure port st atus values. 19 config Configure VLAN and T ransparent modes o ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 23

    19 7. The downl oad progres s displays and en ds with a succes sful downloa d message or with an error message. 8. Press Q or F4 to re turn to the Dev ice-Spec ific Optio ns scree n. When the iMcV -Giga-FiberLinX-II is instal led in a manage d chassis, y ou have the option of usin g UMA to updat e the firmwar e (refer to the iVie w 2 online help fo ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 24

    20 Advertise Ctrl –Selective adver tising is used in combina tion with autonegotiati on to advertise your selected speed and duplex mode for the DATA and EXT MGMT ports. This allows you to advertise all speeds an d duplex modes. Y ou must enabl e autonegotiation for selectiv e advertising t o work. NOTE If a specific speed and/or duplex mode ar e ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 25

    21 NOTE Default mode i s the factory default and i s provided as a starting poin t from which to configure the iMcV- Giga-FiberLinX-II mo dules. This mode does not provi de full management isol ation and is not recom mended for normal use. This section describ es the Telnet/serial port screens and fiel ds available for conf iguring the iMcV-Giga- F ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 26

    22 Transparent Mode Setup This parameter allows you to use all untagged data as the management domain by entering N , or allows you to define a VLAN ID tag fo r the management domain by entering Y . When y ou enter Y , this field expa nds to display th e Management Tag field an d the Man agement Priority fi eld. TRANSPARENT MODE S ETU P Is a VLAN t ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 27

    23 VLAN Mode Screen When you enter N in the T ransparent Mode Setup screen (pa ge 22), th e VLAN Mo de screen displays: In this screen yo u can set the following parameters: • Default Mode • Port V LAN on OPTICS (or UPLINK) port • Port V LAN o n DATA port • Port VLAN Filt er • Manageme nt VL AN (av ailable with all se lecti ons b y def au ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 28

    24 No VLANs ar e defined all owing only un tagged pa ckets to pass th rough the uni t. Port VLAN on OPTICS (or UPLINK) port This pa rameter allows you to rest rict traf fic to a sing le VLAN ID tag for the OPT ICS (or UPLINK) port b y entering Y in the Tags column of the Optics ro w. In the VLAN IDs - Saved c olumn of the D ata row, enter the VLAN ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 29

    25 must enter Y in the Tags c olumn for bot h the Optics ro w and Data ro w. Enter up t o 32 VLAN IDs in the Data VLANs fi elds, plus one for SNMP. Management VLAN and EXT MGMT Tag This se lection is available for all VLAN mode s except fo r the defau lt mode. Configure a VLAN ID for manage ment traffic by enteri ng an ID in the VLAN IDs – Saved ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 30

    26 Configurati on screen, press the space bar, type unit , and press Enter to ope n the Unit Contro l Settings s creen. In this sc reen you can view the uni t FlowContro l, FiberAlert/LinkLoss, Loopba ck, Maximum Frame Size, an d 802.1p Base P riority (logging-in as a User in a Telnet se ssion allows y ou to vie w these settin gs but pr events you ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 31

    27 Unit Max Fram eSz –enter t he maxi mum fram e size on t he unit by u sing th e number keys. The valid valu es are 1518 to 12196. 802.1p Base Pri –set the threshol d betwe en low an d high pr iority on t he unit. For exampl e, when the Bas e VLAN Priority is se t to 4, priority settin gs of 0 through 3 are low priority and settin gs of 4 thro ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 32

    28 NOTE It is not recommended to s et both the RX and TX Band width limits a t the same time. Unit RateCo ntro l Enable/Disable –enable or disable t he ban dwidth li miting fe ature on this unit. VII - Application Overview Before using i McV-Giga- FiberLinX-II in your network, deci de the following: • Will iMcV-Gi ga-FiberLinX-II units be locat ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 33

    29 Will you define VLAN IDs? When you want to use VLAN traffic with speci fic tags on any/all of the DATA ports, you will ne ed to disabl e Transparen cy and define VLAN I Ds (refer t o VLAN Configu ration section). When y ou want to use both VLAN tagged, untagged, or double-tag ged traffic, enable Tran sparency. When you want to use on ly untagg e ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 34

    30 Transparent with Untagged Management Transparent with Untagged Management mo de passes tagged traffic betw een the DATA port and the O PTICS (or UPLIN K) po rt and allows untagged traf fic to be cons idered mana geme nt dom ain t raffi c (u ntagged ). To conf igure th is mode, do the fo llowing: 1. Set the management DIP switch ON for the ports ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 35

    31 NOTE The flow of m anagement domain traffi c is define d by the DIP switches. For example, if the management D IP switch es are on the OPTICS and DATA ports, management domain traffi c is allo wed to flo w through those ports. External Man agement is ON On Of f On DATA: Tagged Data Only OPTICS: Tagged D ata and Untagged Management Domain Traffic ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 36

    32 Transparent with Tagged Management Transparent with Tagged Manage ment mode passes both tagged and unta gged traffic between the DATA port and the OPTICS (o r UPLINK) port. By usin g a VLAN Tag you can isolate and route the management path in the module. This method can be used with o r with out co ntinu ing the managem ent p ath down the EXT MG ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 37

    33 d. Enter the mana gement tag (VL AN ID) and t he priority ( optional). Is a VLAN tag required on Management packets? [ Y ] The Management Tag is [7 ] Management Priority is [0 ] e. Ensure the Are VLAN Tags required on the EXT Port? field is set to N. Are VLAN Tags required on the EXT Port? [ N ] f. Press S or F3 to save the se ttings. This will ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 38

    34 Transparent with Extra Tagging (Q-in-Q) Transparent with Extra Taggin g mode can ad d an extra tag to data receiv ed on the DATA port. By using Extra Tagging in a Ho st/Remot e iMcV-Giga-Fi berLinX-II pair, all data re ceived on the Remote iMcV -Giga-Fib erLinX-I I DATA po rt can b e extra-ta gged and sent out of the Host iMc V-Giga-Fib erL inX- ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 39

    35 Enter the extra tag VLAN ID (for exa mple, 8) an d the Priori ty (opti onal). Thes e values must be identical on both iMcV-Giga-FiberLin X-II modules. The Data Tag is [8 ] Data Priority is [0 ] Are Extra Tags left on the Data Port? [ N ] 4. On the Host iM cV-Giga-Fib erLinX-II modul e, enter Y in the Are Extra Tags left on the Data Port? field t ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 40

    36 Port VLAN The Port VLAN mode allows you to configur e the iMcV-G iga-Fibe rLinX-II to accept only data tagged w ith one specific VLAN ID . This mode can be config ured for either the OPTICS (or UPLINK) po rt or the DATA port. VLAN on DATA Port–Conf iguration To config ure this mode , perform the following: 1. In the Main Configur ation screen, ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 41

    37 In the SNMP field, type Y . VLAN IDs Priorities Tags Current Saved Current Saved Ports Data VLANs are used only Optics [0 ] [ 13 ] [0 ] [ 0 ] [ N ] if Tags are enabled on both he Optics and Data Ports. Data [0 ] [ 0 ] [0 ] [ 0 ] [ Y ] t Management VLAN.........................EXT Mgmt Tag NMP....[0 ] [20 ] [0 ] [0 ] [ Y ] S 4. Press S or F3 to s ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 42

    38 VLAN on OPTIC Port–Configuration To conf igure th is mode, do the fo llowing: 1. In the Main Configur ation screen, pr ess the space bar and type config . The Configuration screen di splays: 2. Enter N in the T ransparen t Mode fiel d and pr ess any key (except S or Q) to o pen the VLAN screen: 3. Enter Y in the Tag s co lumn of the Opti cs ro ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 43

    39 5. Press S or F3 to save the setti ngs. 6. Type reboot . The iMcV-Gi ga-FiberLin X-II is now configu red to pass only VLAN ID 13 from th e OPTICS (or U PLINK) port to the DATA por t. Untagged packets arriving at the DATA port (Tags = N) recei ve a tag (VLAN ID = 13) before bein g sent out of the O PTICS (or UPLINK) port. The VLAN ID number u sed ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 44

    40 Port VLAN Filter The VLA N filter m ode allows y ou to isola te a segmen t of the n etwork t o only ac cept data using some or all of the 32 availabl e VLAN IDs. To conf igure th is mode, do the fo llowing: 1. In the Main C onfiguration s creen, pr ess the s pace bar and ty pe config . The Configuration screen di splays: 2. Enter N in the T rans ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 45

    41 Enter up to 32 VLAN IDs in the Data VLANs rows. VLAN IDs can range from 1 to 4094. Only the VLANs in t his list will pass t hrough the unit. Data VLANs <Optics <----> Data> VLAN 1 [0 ] [101 ] VLAN 12 [0 ] [112 ] VLAN 23 [0 ] [123 ] VLAN 2 [0 ] [102 ] VLAN 13 [0 ] [113 ] VLAN 24 [0 ] [124 ] VLAN 3 [0 ] [103 ] VLAN 14 [0 ] [114 ] VLAN ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 46

    42 Now the iMcV- Giga-FiberLinX- II is configur ed to pass only pa ckets wi th tags cont aini ng the V LAN IDs de fine d in th e Data VLANs table . VLAN ID numbers defined in this table mus t not be the sam e as the number used for the Manageme nt VLAN ID. ON S1 1 2 3 45 67 89 10 Giga-FiberLinX-II DATA: Up to 32 VLAN IDs EXT MGMT: Untagged OPTICS : ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 47

    43 IX - Troubleshooting • If two iMcV-Gi ga-FiberLinX-II Host/Remote uni ts are not communicating properly, make sure one is a Host (DIP s witch #8) and the other i s a Remote (DIP switch #7). I f the second unit is not configured a s a Remote, it will be recognized as a Standalone unit an d the Host and Remote un its will not commu nicate with e ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 48

    44 • To restor e the unit t o factory default settings, us e the cleandb function via the serial port (ref er to the Device- Specific Opti ons from the Co mmand Line se ction fo r more info rmation). This is espec ially hel pful if yo u feel you have configured the module i mproperly. If restarting to fact ory defaults is necessary, IMC Netw orks ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 49

    45 Troubleshoot ing Link Loss/FiberAlert /Link Faul t Pass-Throug h The follow ing diagrams show you how the di fferent troubleshooting configurations for the iMcV-Giga- FiberLinX-II . The iMcV-Gi g a-FiberLinX-II also sends out link pulses from its copper and fiber transmitte rs, but normally has no way of knowing whethe r the cable to t he other ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 50

    46 FX LinkLoss Normally when a fault occurs on the fi ber segment of an iMcV-Giga-FiberLinX-II conver sion, o nly the fibe r port L EDs o n the mod ules i ndicates a faul t. None of the devices conne cted to the RJ-45 ports ar e aware of the faul t. When FX LinkL oss is enabled on the iMc V-Giga-Fibe rLinX-II m odule, the fiber fault is forwarded t ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 51

    47 TX Link Loss When a fault occurs on a twisted pair s egment joining a device to an iMcV-Giga-Fi berLinX-II modul e, the link faul t is not detected by the device con nected to the iMcV-Gig a-FiberLinX-II modul e by fiber. When TX L inkLoss is en abled on the remote iMcV-Giga- FiberLin X-II modul e, a twisted pair fau lt turns off the fiber po rt ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 52

    48 FiberAlert ***WARNING*** Do not enable FiberAlert at both ends. This can cause the fiber link to lock up . When Fibe rAlert is enable d on the rem ote module (pr eferred use), a fault on the receive side of the OP TICS (or UPLI NK) port caus es the transmit ter side to turn of f. This allow s the fibe r connecte d device to de tect a fault i n i ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 53

    49 Link Fault Pass-T hrough ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 54

    50 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1 070 (in the U.S. and Canada); +32-16-55088 0 (Europe) Fax: (949) 465-3020 E-Mail: techsupport@imcn etworks.com Web: www.im cnetworks.com Specifications Power Cons umption (Typi cal): 0.670 A @ 5 V Operatin g Temperatur e: 32° to 122° F ( 0° to 50° C) Storage Te mperature : 0° ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 55

    51 Serial Port Pinout The iMcV-Gi ga-FiberLinX-II features a ser ial port that uses an IBM-compatible DB-9 serial connector. To connect an iMcV-G iga-Fiber LinX to your wor kstation, use a straight-thr ough (pin-t o-pin) cab le. If your workstation has a serial port usin g a connection n ot compatible with a DB-9 COM port, use the pin con nection c ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 56

    52 Notes ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 57

    53 Notes ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 58

    54 Notes ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 59

    55 Saf ety C ertif icat ion s UL/ CUL: Listed to Safety of Inform ation Techn ology Equipment, includin g Electrical Busin ess Equipm ent. CE: T he prod ucts desc ribed here in comp ly with th e Counc il Direct ive on Electromagne tic Compatibility (89/33 6/EEC) and the Council Directive on Electrical Eq uipment Design ed for use within Certain Vol ...

  • IMC Networks iMcV-Giga-FiberLinX-II - page 60

    19772 Pauling • Foothill Ranch, CA 926 10-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetwork s.com © 2007 IMC Networks. Al l rights reserved. The informatio n in this documen t is subje ct to ch ange with out notice. IMC Networks assumes no responsibility for any errors that may appear in this document . iMcV-Giga- FiberLinX-II ...

Manufacturer IMC Networks Category Network Card

Documents that we receive from a manufacturer of a IMC Networks iMcV-Giga-FiberLinX-II can be divided into several groups. They are, among others:
- IMC Networks technical drawings
- iMcV-Giga-FiberLinX-II manuals
- IMC Networks product data sheets
- information booklets
- or energy labels IMC Networks iMcV-Giga-FiberLinX-II
All of them are important, but the most important information from the point of view of use of the device are in the user manual IMC Networks iMcV-Giga-FiberLinX-II.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals IMC Networks iMcV-Giga-FiberLinX-II, service manual, brief instructions and user manuals IMC Networks iMcV-Giga-FiberLinX-II. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product IMC Networks iMcV-Giga-FiberLinX-II.

Similar manuals

A complete manual for the device IMC Networks iMcV-Giga-FiberLinX-II, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use IMC Networks iMcV-Giga-FiberLinX-II by users. Manuals are usually written by a technical writer, but in a language understandable to all users of IMC Networks iMcV-Giga-FiberLinX-II.

A complete IMC Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual IMC Networks iMcV-Giga-FiberLinX-II - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the IMC Networks iMcV-Giga-FiberLinX-II, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the IMC Networks iMcV-Giga-FiberLinX-II, that we can find in the current document
3. Tips how to use the basic functions of the device IMC Networks iMcV-Giga-FiberLinX-II - which should help us in our first steps of using IMC Networks iMcV-Giga-FiberLinX-II
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with IMC Networks iMcV-Giga-FiberLinX-II
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of IMC Networks iMcV-Giga-FiberLinX-II in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning IMC Networks iMcV-Giga-FiberLinX-II?

Use the form below

If you did not solve your problem by using a manual IMC Networks iMcV-Giga-FiberLinX-II, ask a question using the form below. If a user had a similar problem with IMC Networks iMcV-Giga-FiberLinX-II it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)