    OWNER`S MANUAL ELDORADO, ADIRONDACK, JURASSIEN, CELTIC AND SAVANNAH US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVES Verified and tested following ULC S627 and UL 1482 Standards by: Manufactured by : STOVE BUILDER INTERNATIONAL INC. 1700, Léon-Harmel, Québec (Québec) G1N 4R9 Tel : ( 418 ) 527-3060 Fax : ( 418 ) 527-4311 w w w .dr ...

  • Drolet WOODSTOVES - page 2

    TABLE OF CONTENTS INTRODUCTION ............................................................................................................................. 2 TECHNICAL SPECIFICATIONS ..................................................................................................... 3 TIPS ON WOOD HEATING ......................................... ...

  • Drolet WOODSTOVES - page 3

    2 INTRODUCTION SBI INC., one of the most im portant wood stove and fireplac e manufacturers in Canada, congratulates you on your purchase and wishes to help you get maximum satisfaction from your wood stove. In the pages that follow, we will give you advice on wood heating and controlled combustion as well as technica l specifications regarding ins ...

  • Drolet WOODSTOVES - page 4

    3 TECHNICAL SPECIFICATIONS Combustible: Wood Recommended Surface 500 to 1 500 ft 2 (47 to 140 m 2 ) Heating Capacity : E.P.A : 44 000 BTU/h (12.8kW) Efficiency : 75.32 % Emissions: 6.28 g/h Colours : Metallic Black Flue Pipe Diameter : 6’’ (152 mm) Chimney type : 2 100°F (650 °C) Minimum Chimney Height : 12’ (3,66 m) Maximum Log Length : 18 ...

  • Drolet WOODSTOVES - page 5

    4 TIPS ON WOOD HEATING Wood is a renewable energy. It is also a very clean heat source when used with appliances that are certified by the U.S. Environmental Protection Agency (EPA), a standard accepted in Canada as well. EPA-certified wood stoves are different than conventional wood stoves. Burning with an EPA-certified wood stove may ther efore r ...

  • Drolet WOODSTOVES - page 6

    ASSEMBLY PEDESTAL AND PANELS Pedestal Base Installation: 1. Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supplied screws. 2. Slide the ash pan in position. Side Panels and Ash Lip Installation: 1. Start by fixing the front part of the decorative side in the two clips welded on the sides of the fir ...

  • Drolet WOODSTOVES - page 7

    LEGS AND ASH PAN Ash Lip Installation : 1. Just clip the ash lip into position, centred just below the door. 2. Slide the ash pan in position. 6 ...

  • Drolet WOODSTOVES - page 8

    DOOR ADJUSTMENT In order for your stove to operate properly, the door shoul d be adjusted periodically to provide an air tight fit. To adjust: • Remove the lock pin (spring pin) by pulling and turning it using pliers ("wise grip") • Turn the handle counter clock wise one turn to increase pressure • Re-install the lock pin (spring pi ...

  • Drolet WOODSTOVES - page 9

    THE BENEFITS OF INSTALLING A BLOWER A blower can be installed at t he back of your DROLET stove. This option is necessary if you wish to redistribute into a room the heat trapped at the back of your stove. By forcing hot air toward the front, the blower enables you to extend the radiation power of your stove. You can purchase this option through yo ...

  • Drolet WOODSTOVES - page 10

    9 INSTALLATION SAFETY NOTICE • I F THIS STOVE IS NOT PROPERLY INSTALLED , A HOUSE FIRE MAY RESULT . T O REDUCE THE RISK OF FIRE , FOLLOW THE INSTALLATION INSTRUCTIONS . F AILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE , BODILY INJURY , OR EVEN DEATH . • C ONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OF FICIALS ABOUT RESTRICTIO ...

  • Drolet WOODSTOVES - page 11

    FLOOR PROTECTOR Your wood stove should be placed on a non-com bustible surface. The floor protector should be under the stove, eighteen inches bey ond the front and eight inches beyond each side of the fuel loading and as h removal opening. If there is a horizontal section of chimney connector, the floor protector should go under it and two inches ...

  • Drolet WOODSTOVES - page 12

    CLEARANCES FROM COMBUSTIBLES It is of outmost importance t hat the clearances to combusti ble materials be scrupulously respected upon installation of the stove you hav e selected. Refer to the tables below : Single pipe / Double pipe Model A B C D E F Eldorado 15/6 18/18 12/12 21.5/ 12.5 30.5/30.5 24/24 Adirondack 15/5 12/12 10/8 21. 5/11.5 24.5/2 ...

  • Drolet WOODSTOVES - page 13

    12 REDUCED CLEARANCES You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. These heat radiation shields must be installed permanently, and can include sheet metal, a rigid non-co mbustible sheet or a masonry wall. Clearances of not less than 1" (25 mm) and not more than 3" (7 ...

  • Drolet WOODSTOVES - page 14

    13 CHIMNEY Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must co mply with UL 103 or ULC S629 standards; therefore it must be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer's specifications. If you are using a masonry chi ...

  • Drolet WOODSTOVES - page 15

    CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have t he same diameter as the stove outlet. If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draught. The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.021" or 0.53 m ...

  • Drolet WOODSTOVES - page 16

    TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY: ROOF FLASHING 18" CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIEL D Vertical installation 15 ...

  • Drolet WOODSTOVES - page 17

    MASONRY CHIMNEY: Cl a y l i n e r Thim b l e C l ean out door 16 ...

  • Drolet WOODSTOVES - page 18

    FACTORY BUILT THIMBLE: 17 ...

  • Drolet WOODSTOVES - page 19

    BRICK THIMBLE: 18 ...

  • Drolet WOODSTOVES - page 20

    19 OUTSIDE COMBUSTION AIR Your DROLET stove is approved to be insta lled with an outside air intake which is necessary for a mobile home. This type of installation is also required in air tight houses and houses with negative pressure problems. Y ou can purchase this option through your DROLET dealer. Make sure to specify th is part number: #AC0208 ...

  • Drolet WOODSTOVES - page 21

    20 WOODSTOVE UTILISATION Your heating unit was designed to burn wood onl y; no other materials should be burnt. Wastes and other flammable materials should not be burnt in your wood stove. Any type of wood may be used in your stove, but specif ic varieties have better energy yields than others. Please consult the following table in order to make th ...

  • Drolet WOODSTOVES - page 22

    21 Smaller pieces of wood will dry fa ster. All logs exceeding 6" in diameter should be split. The wood should not be stored directly on the ground. Air should circulate through the cord. A 24" to 48" air space should be le ft between each row of logs, which should be placed in the sunniest location possible. The upper layer of wood ...

  • Drolet WOODSTOVES - page 23

    HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of com bustion you want for each given situation. The wood will burn slowly if the wood stove air intake control is adjusted to reduce the oxygen supply in the combustion chamber to a minimum. On t he other hand, wood will burn q ...

  • Drolet WOODSTOVES - page 24

    23 RELOADING Once you have obtained a good bed of embers, y ou should reload the unit. In order to do so, open the air controls to maximum a few seconds prior to opening the stove's door. Then proceed by opening the door very slowly; open it one or two inches for 5 to 10 seconds, before opening it completely to in crease the draught and t hus ...

  • Drolet WOODSTOVES - page 25

    24 ASH DISPOSAL Ashes should be removed from the stove ever y few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold, such as in the morning. Always dispose of ashes in a metal container wit h a tight fitting lid. Plac e this container on a non combustible floor or on the ground, well away from all combustible mate ...

  • Drolet WOODSTOVES - page 26

    25 MAINTENANCE Your Drolet stove is a high efficiency stove and therefore require littl e maintenance. It is important to perform a visual inspection of the stove every time it is emptied, in order to insure that no parts have been damaged, in which case repairs must be performed immediately. GLASS • Inspect the glass regularly in order to detect ...

  • Drolet WOODSTOVES - page 27

    26 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable . This warranty covers brand new products only, whic h have not been altered, m odified nor repaired since shipm ent from factory . Proof of purchase (dated bill of sale), model name and serial num ber must be ...

Manufacturer Drolet Category Stove

Documents that we receive from a manufacturer of a Drolet WOODSTOVES can be divided into several groups. They are, among others:
- Drolet technical drawings
- WOODSTOVES manuals
- Drolet product data sheets
- information booklets
- or energy labels Drolet WOODSTOVES
All of them are important, but the most important information from the point of view of use of the device are in the user manual Drolet WOODSTOVES.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Drolet WOODSTOVES, service manual, brief instructions and user manuals Drolet WOODSTOVES. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Drolet WOODSTOVES.

Similar manuals

A complete manual for the device Drolet WOODSTOVES, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Drolet WOODSTOVES by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Drolet WOODSTOVES.

A complete Drolet manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Drolet WOODSTOVES - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Drolet WOODSTOVES, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Drolet WOODSTOVES, that we can find in the current document
3. Tips how to use the basic functions of the device Drolet WOODSTOVES - which should help us in our first steps of using Drolet WOODSTOVES
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Drolet WOODSTOVES
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Drolet WOODSTOVES in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Drolet WOODSTOVES?

Use the form below

If you did not solve your problem by using a manual Drolet WOODSTOVES, ask a question using the form below. If a user had a similar problem with Drolet WOODSTOVES it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)