Manual Trane TAM7B0C60H51SA

28 pages 3.84 mb
Download

Go to site of 28

Summary
  • Trane TAM7B0C60H51SA - page 1

    V ariab le Speed Modular Multi-position Air Handler s 2-5 T ons T AM7A0A24H21SB T AM7A0B30H21SB T AM7A0C36H31SB T AM7A0C42H31SB PUB. NO . 22-1847-03 T AM7A0C48H41SB T AM7A0C60H51SB T AM7B0C60H51SA ...

  • Trane TAM7B0C60H51SA - page 2

    2 Pub . No . 22-1847-03 Featur es and Benefits © 2012 T rane • Unique cabinet design – 2% or less air leakage – Precision applied - durab le door seals – Specially designed air seal around refrigerant, condensate and conduit connections – Double w all f oamed cabinet system – R-4.2 Insulating V alue (A vg Insulat - ing V alue R-8.2) ? ...

  • Trane TAM7B0C60H51SA - page 3

    Pub . No . 22-1847-03 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benets 5 General Data 6 T AM7A0A24H21SB 6 T AM7A0B30H21SB 6 T AM7A0C36H31SB 6 T AM7A0C42H31SB 6 T AM7A0C48H41SB 6 T AM7A0C60H51SB 6 T AM7B0C60H51SA 6 P erformance Data 7 Electrical Data 13 Field Wiring 20 Con ver tibility 24 Dimensio ...

  • Trane TAM7B0C60H51SA - page 4

    4 Pub . No . 22-1847-03 Optional Equipment Accessory Number Description Fits Cabinet Size BA YEV AC05BK1AA Electric Heater , 5kW , Breaker , RS-485 Control, 1 Ph A to C BA YEV AC05LG1AA Electric Heater , 5kW , Lugs, RS-485 Control, 1 Ph A to C BA YEV AC08BK1AA Electric Heater , 8kW , Breaker , RS-485 Control, 1 Ph A to C BA YEV AC08LG1AA Electric H ...

  • Trane TAM7B0C60H51SA - page 5

    Pub . No . 22-1847-03 5 5 Conduit Connections Locations r Integrated Horizontal Drain P ans 6 T ool-less Door Fastener s 7 Alert Code Viewport e Compact 20.8” Depth with Doors Remo ved 1 Unique Cabinet Design 2 Precision Durable Door Seals q Electronic Expansion V alve (EEV) 3 Refrigeration Connections 9 All Aluminum Coil t Safety Door Switch 4 C ...

  • Trane TAM7B0C60H51SA - page 6

    6 Pub . No . 22-1847-03 General Data PRODUCT SPECIFICA TIONS MODEL T AM7A0A24H21SB RA TED V OL TS/PH/HZ. 200-230/1/60 RA TINGS 1 See O .D . Specications INDOOR COIL — T ype Plate Fin Rows — F .P .I. 3 - 14 F ace Area (sq. ft.) 3.67 T ube Size (in.) 3/8 Refrigerant Control EEV Drain Conn. Size (in.) 2 3/4 NPT DUCT CONNECTIONS See Outline Draw ...

  • Trane TAM7B0C60H51SA - page 7

    Pub . No . 22-1847-03 7 T AM7A0A24 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9 1.5 tons 360 CFM/ton CFM W atts 542 / 652 38 ...

  • Trane TAM7B0C60H51SA - page 8

    8 Pub . No . 22-1847-03 T AM7A0B30 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9 1.5 tons 360 CFM/ton CFM W atts 591 / 685 30 ...

  • Trane TAM7B0C60H51SA - page 9

    Pub . No . 22-1847-03 9 T AM7A0C36 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9 2 tons 350 CFM/ton CFM W atts 724 / 858 44 / ...

  • Trane TAM7B0C60H51SA - page 10

    10 Pub . No . 22-1847-03 Minimum Heating Airo w Settings T AM7A0C42 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9 2.5 tons ...

  • Trane TAM7B0C60H51SA - page 11

    Pub . No . 22-1847-03 11 Minimum Heating Airo w Settings T AM7A0C48 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9 3 tons 33 ...

  • Trane TAM7B0C60H51SA - page 12

    12 Pub . No . 22-1847-03 Minimum Heating Airo w Settings T AM7A0C60H51SB, T AM7B0C60H51SA AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.1 0.3 0.5 0.7 0.9 0.1 0.3 ...

  • Trane TAM7B0C60H51SA - page 13

    Pub . No . 22-1847-03 13 Electrical Data Notes: 1. See Air Handler nameplate for appro ved combinations of Air Handlers and Heaters 2. Heater model numbers may ha v e additional sufx digits. kW BTUH kW BTUH No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15 BAYEVAC05++1 1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25 BAYEVAC08++1 1 7.68 26200 32.0 44 45 5. ...

  • Trane TAM7B0C60H51SA - page 14

    14 Pub . No . 22-1847-03 Electrical Data kW BTUH kW BTUH No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15 BAYEVAC05++1 1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25 BAYEVAC08++1 1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40 BAYEVAC10++1 1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50 BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 32 35 7.20 24600 20.0 28 30 BAYEVBC15L ...

  • Trane TAM7B0C60H51SA - page 15

    Pub . No . 22-1847-03 15 Electrical Data kW BTUH kW BTUH No Heater 0 - - 4.2** 5 15 - - 4.2** 5 15 BAYEVAC05++1 1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYEVAC08++1 1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYEVAC10++1 1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 34 35 7.20 24600 20.0 30 30 BAYEVBC15L ...

  • Trane TAM7B0C60H51SA - page 16

    16 Pub . No . 22-1847-03 Electrical Data kW BTUH kW BTUH No Heater 0 - - 5.5** 7 15 - - 5.5** 7 15 BAYEVAC05++1 1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYEVAC08++1 1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYEVAC10++1 1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 34 35 7.20 24600 20.0 30 30 BAYEVBC15L ...

  • Trane TAM7B0C60H51SA - page 17

    Pub . No . 22-1847-03 17 AIR HANDLER ELECTRIC HEA TER PRESSURE DROP Air handler electric heater pressure drop is negligib le f or the heaters and is inc luded in the airow data f or the Series 7 air handler s. Electrical Data ...

  • Trane TAM7B0C60H51SA - page 18

    18 Pub . No . 22-1847-03 T AM7 AIR HANDLER AND HEA TER MA TRIX - ALLO WBLE COMBINA TIONS Electrical Data AIR HANDLER MODEL NUMBER AC05BK1AA 4.80 Kw BK AC05LG1AA 4.80 Kw LG AC08BK1AA 7.68 Kw BK AC08LG1AA 7.68 Kw LG AC10BK1AA 9.60 Kw BK AC10LG1AA 9.60 Kw LG BC15BK1AA 14.40 Kw BK BC20BK1AA 19.20 Kw BK CC25BK1AA 24.00 Kw BK TAM7A0A24H21SB YYYY Y 1 Y 1 ...

  • Trane TAM7B0C60H51SA - page 19

    Pub . No . 22-1847-03 19 Electrical Data WIRING DIA GRAM FOR T AM7 AIR HANDLERS ...

  • Trane TAM7B0C60H51SA - page 20

    20 Pub . No . 22-1847-03 Comfort Control Air Handler Air Conditioner Neatly bundle all low voltage wires behind the service valve cover as shown. Field wiring Y ellow Blue Red Y ellow Green White Blue B B - Blue W G Y1 Y2 Y1 - Y ellow R O O R B YI W1 YO Y2 BK G W2 W3 * (In) (Out) Field Wiring • * For multiple stages of electric heat, jumper W1, W ...

  • Trane TAM7B0C60H51SA - page 21

    Pub . No . 22-1847-03 21 Comfort Control Air Handler Heat Pump Neatly bundle all low voltage wires behind the service valve cover as shown. Field wiring Y ellow Blue Black (X2) Red Orange Red Y ellow Orange Green White Blue B B - Blue W X2 G Y1 Y1 - Y ellow R O O R B YI Y2 W1 YO BK G W2 W3 * R - Red O - Orange (In) (Out) W1 - White Field Wiring Sin ...

  • Trane TAM7B0C60H51SA - page 22

    22 Pub . No . 22-1847-03 T wo Stage Cooling Field Wiring Comfort Control Air Handler Air Conditioner Neatly bundle all low voltage wires behind the service valve cover as shown. Y ellow/Red Field wiring Y ellow/Black Blue Red Y ellow Green White Blue B B - Blue W G Y1 Brown Y2 Y1 - Y ellow Y2 - Brown R O O R B YI W1 YO Y2 BK G W2 W3 * (In) (Out) ? ...

  • Trane TAM7B0C60H51SA - page 23

    Pub . No . 22-1847-03 23 Comfort Control Air Handler Heat Pump Neatly bundle all low voltage wires behind the service valve cover as shown. Y ellow/Red Field wiring Y ellow Blue Black (X2) Red Orange Red Y ellow Orange Green White Blue B B - Blue W X2 G Y1 Brown Y2 Y1 - Y ellow Y2 - Brown R O O R B YI W1 YO Y2 BK G W2 W3 * R - Red O - Orange (In) ( ...

  • Trane TAM7B0C60H51SA - page 24

    24 Pub . No . 22-1847-03 T AM7 Conver tibility Multi-position Air Handler Airflow Airflow Airflow Airflow Upflow Condensate Drains Refrigerant Connections Downflo w Condensate Drains Refrigerant Connections V er tical Downflo w* (as shipped) Horizontal Left* V er tical Upflow* Horizontal Right* Horizontal Left Condensate Drains Refrigerant Connecti ...

  • Trane TAM7B0C60H51SA - page 25

    Pub . No . 22-1847-03 25 Dimensions T AM7 AIR HANDLER DIMENSIONAL D A T A T AM7 AIR HANDLERS ARE ALL TWO PIECE CABINETS. Model No . H W D T AM7A0A24H21SB 49.9 17.5 21.75 T AM7A0B30H21SB 55.7 21.3 21.75 T AM7A0C36H31SB 56.9 23.5 21.75 T AM7A0C42H31SB 56.9 23.5 21.75 T AM7A0C48H41SB 61.7 23.5 21.75 T AM7A0C60H51SB T AM7B0C60H51SA 61.7 23.5 21.75 D H ...

  • Trane TAM7B0C60H51SA - page 26

    26 Pub . No . 22-1847-03 T AM7 OUTLINE DRA WING MODEL NO . A B C D E F H FLO W CONTROL GAS LINE BRAZE LIQ LINE BRAZE T AM7A0A24H21SB 49.9 17.5 14.5 39.6 14.5 7.3 24.4 EEV 3/4 3/8 T AM7A0B30H21SB 55.7 21.3 18.4 45.5 18.4 9.2 24.8 EEV 3/4 3/8 T AM7A0C36H31SB 56.9 23.5 20.5 46.7 20.5 10.3 24.2 EEV 7/8 3/8 T AM7A0C42H31SB 56.9 23.5 20.5 46.7 20.5 10.3 ...

  • Trane TAM7B0C60H51SA - page 27

    Pub . No . 22-1847-03 27 ...

  • Trane TAM7B0C60H51SA - page 28

    T rane 6200 T roup Highway T yler , TX 75707 www .trane.com 03/12 The manuf acturer has a policy of continuous product and product data improv ement and it reserves the right to change design and specifications without notice. ...

Manufacturer Trane Category Air Conditioner

Documents that we receive from a manufacturer of a Trane TAM7B0C60H51SA can be divided into several groups. They are, among others:
- Trane technical drawings
- TAM7B0C60H51SA manuals
- Trane product data sheets
- information booklets
- or energy labels Trane TAM7B0C60H51SA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Trane TAM7B0C60H51SA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Trane TAM7B0C60H51SA, service manual, brief instructions and user manuals Trane TAM7B0C60H51SA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Trane TAM7B0C60H51SA.

Similar manuals

A complete manual for the device Trane TAM7B0C60H51SA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Trane TAM7B0C60H51SA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Trane TAM7B0C60H51SA.

A complete Trane manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Trane TAM7B0C60H51SA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Trane TAM7B0C60H51SA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Trane TAM7B0C60H51SA, that we can find in the current document
3. Tips how to use the basic functions of the device Trane TAM7B0C60H51SA - which should help us in our first steps of using Trane TAM7B0C60H51SA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Trane TAM7B0C60H51SA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Trane TAM7B0C60H51SA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Trane TAM7B0C60H51SA?

Use the form below

If you did not solve your problem by using a manual Trane TAM7B0C60H51SA, ask a question using the form below. If a user had a similar problem with Trane TAM7B0C60H51SA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)