  • Invacare IRC5PAW - page 1

    Dealer: This manual MUST be given to the end user. User: BEFORE using this product, read this manual and save for future reference. Operator’s Manual For more information regarding Invacare products, parts, and services, please visit www.invacare.com Perfecto 2 ™ Series Oxygen Concentrators without SensO 2 ® , Oxygen Concentrators with SensO 2 ...

  • Invacare IRC5PAW - page 2

    WARNING Perfecto 2 ™Series 2 Part No 1150713  WARNING DO  NOT  use  this  product  or  any  av ailable  optional  equipment  without  first  completely  reading  and  understanding  these  instructions  and  any  additional  instructional  material  such  as  owner ’ ...

  • Invacare IRC5PAW - page 3

    TABLE OF CONTENTS Part No 1150713 3 Perfecto 2 ™Series ACCESSORIES .................................................. 2 SPECIAL NOTES ............................................... 4 LABEL LOCATION ............................................ 6 SECTION 1—GENERAL GUIDELINES ..................... 7 Radio Frequency Interference .. ............... ...

  • Invacare IRC5PAW - page 4

    SPECIAL NOTES Perfecto 2 ™Series 4 Part No 1150713 SPECIAL NOTES Signal  w ords  are  used  in  this  manual  and  apply  to  hazards  or  unsafe  practices  which  could  result  in  personal  injury  or  property  damage.  Refer  to  the  following  table  for ? ...

  • Invacare IRC5PAW - page 5

    SPECIAL NOTES Part No 1150713 5 Perfecto 2 ™Series CAUTION “Caution:  Statutory  law  can  restrict  this  device  to  sal e  by  or  on  order  of  a  physician,  or  any  other  practitioner  licens ed  by  the  law  of  the  governmental  agency  in  which ...

  • Invacare IRC5PAW - page 6

    LABEL LOCATION Perfecto 2 ™Series 6 Part No 1150713 LABEL LOCATION Serial Number Lab el is located on the resonator intake assembly Specification Label is located on the back near the bottom Perfecto 2 ™ FOR OPERATING INSTRUCTIONS or ALARMS (See Operator’s Manual) DANGER - RISK OF FIRE NO SMOKING - Keep ALL sources of ignition out of the room ...

  • Invacare IRC5PAW - page 7

    SECTION 1—GENERAL GUIDELINES Part No 1150713 7 Perfecto 2 ™Series SECTION 1—GENERAL GUIDELINES In  order  to  ensure  the  safe  installation,  assembly  and  operation  of  the  Pe r f e c t o 2  concentrator  these  instructions  MUST  be  followed.  WARNING This  section  conta ...

  • Invacare IRC5PAW - page 8

    SECTION 1—GENERAL GUIDELINES Perfecto 2 ™Series 8 Part No 1150713 Operating Information For  optimum  performance,  Inv acare  recommends  that  each  concentrator  be  on  and  running  for  a  minimum  of  30  minutes  at  a  time.  Shorter  periods  of  operation  may ...

  • Invacare IRC5PAW - page 9

    SECTION 1—GENERAL GUIDELINES Part No 1150713 9 Perfecto 2 ™Series Radio Frequency Interference This  equipmen t  has  been  tested  and  found  to  comply  with  EMC  limits  specified  by  IEC/EN  60601 ‐ 1 ‐ 2.  These  limits  are  designed  to  provide  a  reasonable ? ...

  • Invacare IRC5PAW - page 10

    SECTION 2—FEATURES Perfecto 2 ™Series 10 Part No 1150713 SECTION 2—FEATURES Oxygen Outlet Flowmeter Oxygen Purity Indicator Lights / Fault and Power Indicator Lights Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter REAR VIEW *HF Outlet Fitting Power Cord *NOTE:  This  outlet  fitting  is  to  be  used  on ...

  • Invacare IRC5PAW - page 11

    SECTION 3—HANDLING Part No 1150713 11 Perfecto 2 ™Serie s SECTION 3—HANDLING The  concentrator  should  AL W A YS  be  kept  in  the  upright  position  to  prevent  cabinet  damage  while  being  transported. If  the  concentrator  is  to  be  reshipped  by  common  c ...

  • Invacare IRC5PAW - page 12

    SECTION 4—TECHNICAL DESCRIPTION Perfecto 2 ™Series 12 Part No 1150713 SECTION 4—TECHNICAL DESCRIPTION The  Invacare  Per f e c t o 2  concentr ator  is  used  by  patients  with  respiratory  disorders  who  require  supplemental  oxygen.  The  device  is  not  intended  to  susta ...

  • Invacare IRC5PAW - page 13

    SECTION 5—TYPICAL PRODUCT PARAMETERS Part No 1150713 13 Perfecto 2 ™Serie s SECTION 5—TYPICAL PRODUCT PARAMETERS Alternating Current Type BF equipment Unit runnin g Unit not runnin g Attention - Consider Accompanying Documents DO NOT smoke Class II, Double Insulated Not Protected Electrical Requirements: 230 VAC ± 10% (253 VAC/20 7 VAC), 50 ...

  • Invacare IRC5PAW - page 14

    SECTION 5—TYPICAL PRODUCT PARAMETERS Perfecto 2 ™Series 14 Part No 1150713 Flow Range: 0.5 to 5 L/min (maximum ). For flowrates less than 1 L/min, we recommend th e use of the Invacare Pediatric Flowmeter Accessory (IRCPF16AW). Low Flow Alarm: 0 L/min to 0.5 L/min Rapid Audible Alarm Beeping (No Accessories Connected). Average Power Consumption ...

  • Invacare IRC5PAW - page 15

    SECTION 5—TYPICAL PRODUCT PARAMETERS Part No 1150713 15 Perfecto 2 ™Serie s No AP/APG Not suitable for use in the presence of a flammable anaesthetic mixture. Standards and Regulatory Listing: IRC5PO2AW/IRC5PAW IEC/EN61000-3-2 IEC/EN61000-3-3, IEC/EN 60601-1 , A1, A2 IEC/EN 60601-1 -2 IRC5PO2AW Models Only ISO8359 MDD 93/42/EEC, Annex I and IX ...

  • Invacare IRC5PAW - page 16

    SECTION 5—TYPICAL PRODUCT PARAMETERS Perfecto 2 ™Series 16 Part No 1150713 IRC5PO2AW INDICATORS IRC5PAW INDI CATORS LABEL SYMBOL O 2 PURITY INDICATOR LIGHTS (LED) SYSTEM OKAY O 2 over 85% (± 2%) GREEN Indicator Light O 2 Between 73% (± 3%) to 85% (±2%) YELLOW Indicator light A. YELLOW Solid B. YELLOW Flashing Sensor Failure Call a qualif ied ...

  • Invacare IRC5PAW - page 17

    SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 17 Perfecto 2 ™Serie s SECTION 6— OPERATING INSTRUCTIONS Introduction Yo u r  oxygen  concentrator  is  intended  for  individual  use.  It  is  an  electronically  operated  device  that  separates  oxygen  from  room  air .  It  p ...

  • Invacare IRC5PAW - page 18

    SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 18 Part No 1150713 Yo u r  oxygen  concentrator  will  perform  best  when  operated  under  the  conditions  outlined  in  the  Ty p i c a l  Product  P arameters  on  page 13.  Usage  in  environments  other  than  those ...

  • Invacare IRC5PAW - page 19

    SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 19 Perfecto 2 ™Serie s 3. Insert  a  flathead  screwdriver  in  the  plate  groove  on  the  top  edge  of  the  filter  access  door  and  gently  pry  the  filter  access  door  off  (FIGURE  6.2). 4. Pull  up  ...

  • Invacare IRC5PAW - page 20

    SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 20 Part No 1150713 10. After  assembly ,  ensure  that  oxygen  is  flowing  through  the  cannula. FIGURE 6.3 Humidifier Compartmen t Power Switch NOTE:  For  this  pr ocedure,  refe r  to  FIGURE  6.4. 1. Press  power  switch  to  O ...

  • Invacare IRC5PAW - page 21

    SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 21 Perfecto 2 ™Serie s Flowrate NOTE:  For  this  procedure,  refe r  to  FIGURE  6.5. NOTE:  Ta k e  care  not  to  set  the  flow  above  RED  ring.  An  oxygen  flow  gr eater  than  5  L/min  will  decr ease  the ...

  • Invacare IRC5PAW - page 22

    SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 22 Part No 1150713 SensO 2 Oxygen Purity Indicator - Model IRC5PO2AW This  feature  monitors  the  purity  of  oxygen  generated  by  the  oxygen  concentrator .  If  purity  falls  below  factory  preset  standards,  indicator  light ...

  • Invacare IRC5PAW - page 23

    SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 23 Perfecto 2 ™Serie s FIGURE 6.6 Explanation of Oxygen Purity Indicator Lights - Model IRC5PO2AW Explanation of Indicator Lights - Model IRC5PAW NOTE:  For  this  procedure,  refe r  to  FIGURE  6.7. IRC5PAW Model Indicator Light Explanation RED  light  () ‐  T ...

  • Invacare IRC5PAW - page 24

    SECTION 7—MAINTENANCE Perfecto 2 ™Series 24 Part No 1150713 SECTION 7—MAINTENANCE  WARNING The  Invacare  concentrators  are  specifically  designed  to  minimize  routine  preventiv e  mainte nance.  Only  qualified  personnel  should  perform  preventiv e  maintenance  on  the  ...

  • Invacare IRC5PAW - page 25

    SECTION 7—MAINTENANCE Part No 1150713 25 Perfecto 2 ™Serie s 2. Clean  the  cabinet  filter  with  a  va c u u m  cleaner  or  wa s h  in  w arm  soapy  wa t e r  and  rinse  thoroughly . 3. Dry  the  filter  thoroughly  before  reinstallation. FIGURE 7.1 Cleaning the Cabinet Filter ...

  • Invacare IRC5PAW - page 26

    SECTION 7—MAINTENANCE Perfecto 2 ™Series 26 Part No 1150713 PREVENTIVE MAINTENANCE RECORD Model  No.  IRC  ______________  Serial  No.________________ On  Each  Inspection *NOTE:  Refer  to  Preventive  Ma intenance  section  of  Service  Manual. **NOTE:  Model  not  available  within  ...

  • Invacare IRC5PAW - page 27

    SECTION 8—TROUBLESHOOTING GUIDE Part No 1150713 27 Perfecto 2 ™Serie s SECTION 8—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: Main Power Loss: Short beeps, long pause 1. Power cord not plugged in. 1. Insert plug in to outlet. Concentrator not operating, power switch On. 2. No power at outlet. 2 . Inspect house circuit break ...

  • Invacare IRC5PAW - page 28

    SECTION 8—TROUBLESHOOTING GUIDE Perfecto 2 ™Series 28 Part No 1150713 YELLOW or RED light Illuminated. Alarm: Continuo us On RED light only. * Only applies to IRC5PO2AW models. 1. Low oxygen purity.* 1. Clean or Replace filters. 2. Kinked or blocked tubing, cannula or humidifier.* 2. Inspect for kinks or blockages. Correct, clean or replace ite ...

  • Invacare IRC5PAW - page 29

    SECTION 9—OPTIONAL ACCESSORIES Part No 1150713 29 Perfecto 2 ™Serie s SECTION 9—OPTIONAL ACCESSORIES The  following  optional  accessories  are  also  av ailable:  • Standard  Adult  Nasal  Cannula,  2.1  m  (7  feet) ‐ M3120 • Standard  Humidifier ‐ M5120 • PreciseRX™  P ed ...

  • Invacare IRC5PAW - page 30

    RECYCLING INFORMATION Perfecto 2 ™Series 30 Part No 1150713 RECYCLING INFORMATION This  product  has  been  supplied  from  an  environmentally  aw are  manufacturer  that  complies  with  the  Wa s t e  Electrical  and  Electronic  Equipment  (WEEE)  Directive  2002/96/CE. This  p ...

  • Invacare IRC5PAW - page 31

    LIMITED WARRANTY Part No 1150713 31 Perfecto 2 ™Serie s LIMITED WARRANTY United  Kingdom:  Invacare  Ltd,  South  Road,  Bridgend  Industrial  Estate,  UK ‐ Bridge nd  CF31  3PY Te l :  (44)  (0)1656  664  321,  Fax:  (44)  (0)1656  667  532 UK@inv acare.com  Ireland: Inv acare  ...

  • Invacare IRC5PAW - page 32

    0120 Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio USA 44036-2125 440-329-6000 800-333-6900 Technical Services 440-329-6593 800-832-4707 EU Representative Invacare International Sarl Route de Cité Ouest 2 1196 Gland Switzerland Tel: +41 22 354 60 10 Fax: +41 22 354 60 11 Part No 1150713 Invacare Corporation 2101 E. Lake M ...

Manufacturer Invacare Category Oxygen Equipment

Documents that we receive from a manufacturer of a Invacare IRC5PAW can be divided into several groups. They are, among others:
- Invacare technical drawings
- IRC5PAW manuals
- Invacare product data sheets
- information booklets
- or energy labels Invacare IRC5PAW
All of them are important, but the most important information from the point of view of use of the device are in the user manual Invacare IRC5PAW.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Invacare IRC5PAW, service manual, brief instructions and user manuals Invacare IRC5PAW. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Invacare IRC5PAW.

Similar manuals

A complete manual for the device Invacare IRC5PAW, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Invacare IRC5PAW by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Invacare IRC5PAW.

A complete Invacare manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Invacare IRC5PAW - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Invacare IRC5PAW, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Invacare IRC5PAW, that we can find in the current document
3. Tips how to use the basic functions of the device Invacare IRC5PAW - which should help us in our first steps of using Invacare IRC5PAW
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Invacare IRC5PAW
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Invacare IRC5PAW in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Invacare IRC5PAW?

Use the form below

If you did not solve your problem by using a manual Invacare IRC5PAW, ask a question using the form below. If a user had a similar problem with Invacare IRC5PAW it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)