    SP ARCcenter 2000E Power Supply Installation Manual Part No.: 802-2700-10 Revision -A, April 1995 A Sun Microsystems, Inc. Business 2550 Garcia Avenue Mountain View, CA 94043 U.S.A. 415 960-1300 FAX 415 969-9131 ...

  • Sun Microsystems 2000E - page 2

    Please Recycle  1995 Sun Microsystems, Inc. 2550 Garcia A venue, Mountain V iew , California 94043-1 100 U.S.A. All rights reserved. This pr oduct and related documentation are pr otected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this pr oduct or related documentation ma ...

  • Sun Microsystems 2000E - page 3

    iii Contents 1. Before Y ou Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.1 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.3 T ools Required . . . . . . . . . . . . . ...

  • Sun Microsystems 2000E - page 4

    iv SP ARCserver 2000E Power Supply Installation Manual — April 1995 A.1 Removal Procedur es . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 A.1.1 Opening the Hinged Door . . . . . . . . . . . . . . . . . . . . . A-1 A.1.2 Removing the V ented Fr ont Panels . . . . . . . . . . . . . . A-2 A.1.3 Removing the Side Panels . . . . . ...

  • Sun Microsystems 2000E - page 5

    v Figur es Figure 2-1 Key Switch Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Figure 2-2 AC Distribution Unit Power Switch . . . . . . . . . . . . . . . . . . . . . . 2-3 Figure 2-3 Removing the Power Supply Compartment EMI Panel . . . . . 2-5 Figure 2-4 Disconnecting the Top Power Supply Power Cord . . . . . ...

  • Sun Microsystems 2000E - page 6

    vi SP ARCserver 2000E Power Supply Installation Manual — April 1995 Figure 2-17 Connecting the Power Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 Figure 2-18 Removing the Jumper-Connector and Installing the Sense Cable 2-18 Figure 2-19 Replacing the Power Supply Compartment EMI Panel . . . . . 2-19 Figure 2-20 Local/Remote S ...

  • Sun Microsystems 2000E - page 7

    vii T ables Table 1-1 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Table 2-1 LED Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25 ...

  • Sun Microsystems 2000E - page 8

    viii SP ARCserver 2000E Power Supply Installation Manual — April 1995 ...

  • Sun Microsystems 2000E - page 9

    ix Pr eface This manual provides instr uctions for installing a power supply in a redundant-capable SP ARCcenter ™ 2000 ™ or SP ARCcenter 2000E ™ system. These instructions ar e designed for an experienced service provider . How This Book Is Or ganized Chapter 1, “Before Y ou Start,” is an overview of the tasks involved. Read this chapter ...

  • Sun Microsystems 2000E - page 10

    x SP ARCserver 2000E Power Supply Installation Manual — April 1995 Related Documents The following documents contain information that may be helpful after the upgrade is installed. T able P-1 Related Documents Application T itle Part Number Safety SP ARCcenter 2000 Regulatory Compliance Manual 801-3051 Installation SP ARCcenter 2000 Installation ...

  • Sun Microsystems 2000E - page 11

    Preface xi What T ypographic Changes Mean The following table describes the typographic changes used in this book. Shell Pr ompts in Command Examples The following table shows the default system prompt and super user prompt for the C shell, Bourne shell, and Korn shell. T able P-2 T ypographic Conventions T ypeface or Symbol Meaning Example AaBbCc1 ...

  • Sun Microsystems 2000E - page 12

    xii SP ARCserver 2000E Power Supply Installation Manual — April 1995 Notes, Cautions, and W arnings Warning – This equipment contains lethal voltage. Accidental contact can result in serious injury or death. Caution – Improper handling by unqualif ied personnel can cause serious damage to this equipment. Unqualified personnel who tamper with ...

  • Sun Microsystems 2000E - page 13

    1-1 Befor e Y ou Start 1 This manual provides pr ocedures for installing a power supply in a r edundant- capable SP ARCcenter 2000 or 2000E system cabinet. 1.1 Safety Pr ecautions For your protection, observe the following safety pr ecautions when setting up your equipment: • Follow all cautions, warnings, and instructions marked on the equipment ...

  • Sun Microsystems 2000E - page 14

    1-2 SP ARCserver 2000E Power Supply Installation Manual — April 1995 1 T o protect both yourself and the equipment, observe the following pr ecautions: 1.2 Symbols The following symbols mean: WARNING Risk of electrical shock.To reduce the risk, follow the instructions. WARNING Risk of personal injury. To reduce the risk, follow the instructions. ...

  • Sun Microsystems 2000E - page 15

    Before Y ou Start 1-3 1 CAUTION Risk of equipment damage. To reduce the risk, follow the instructions. AC A terminal to which alternating current or voltage may be applied. ON The principal and stand-by switches are in the ON position. OFF The principal switch is in the OFF position. STAND-BY The stand-by switch is in the STAND-BY position. PROTECT ...

  • Sun Microsystems 2000E - page 16

    1-4 SP ARCserver 2000E Power Supply Installation Manual — April 1995 1 Warning – This equipment contains lethal voltages. Accidental contact can result in serious injury or death. Caution – Improper handling by unqualif ied personnel can cause serious damage to this equipment. Unqualified personnel who tamper with this equipment may be held l ...

  • Sun Microsystems 2000E - page 17

    2-1 Power Supply Installation 2 This chapter provides the complete upgrade pr ocedures. Warning – Risk of electric shock. Do not work inside the cabinet while power is applied to the system. Power down using the procedur e which follows. Perform these tasks in order to install a system power supply . Safety Precautions page 1- 1 Powering Down the ...

  • Sun Microsystems 2000E - page 18

    2-2 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 2.1 Operating System The correct operating system must be installed to support dual power supply operation. The operating system must be: Solaris 2.4 or higher , or Solaris 2.3 with the patch: ID# 101318-59 or later revision level (obtain this patch through your normal service ...

  • Sun Microsystems 2000E - page 19

    Power Supply Installation 2-3 2 Figure 2-1 Key Switch Positions Figure 2-2 AC Distribution Unit Power Switch Standby On Secure Diagnostics Main Power ↓ Off ...

  • Sun Microsystems 2000E - page 20

    2-4 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 2.4 Access Remove all system cover panels before pr oceeding with the upgrade. For these procedur es, refer to Appendix A, “Access.” 2.5 Installing the Bottom Power Supply Note – Read and follow all safety and ESD instructions found in Section 1.1, “Safety Precautions. ...

  • Sun Microsystems 2000E - page 21

    Power Supply Installation 2-5 2 2.5.2 Installing the Supply 2.5.2.1 Preparation 1. Remove the power supply compartment EMI panel Part No. 340-3134-xx covering both power supplies. See Figure 2-3. Remove twelve 10-32 screws securing the panel in place and set aside. Figure 2-3 Removing the Power Supply Compartment EMI Panel 2. Disconnect the top pow ...

  • Sun Microsystems 2000E - page 22

    2-6 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 Figure 2-4 Disconnecting the T op Power Supply Power Cord 3. Remove the power supply cage cover panel. Remove six screws securing the panel, Part No. 340-3157-xx to the power supply cage and remove the panel (it will not be r eused). See Figure 2-5. P ower cord ...

  • Sun Microsystems 2000E - page 23

    Power Supply Installation 2-7 2 Figure 2-5 Removing the Power Supply Cage Cover Panel Remove the AC Distribution Unit 1. Disconnect all AC cables plugged into the unit, and disconnect cables from connectors J2 and J3. See Figure 2-6. Figure 2-6 AC Distribution Unit Removal and Replacement Remov e screws, 6 places Cage cov er panel Springfingers (2 ...

  • Sun Microsystems 2000E - page 24

    2-8 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 Note – J3 is located on the top of the AC distribution unit, J2 is on the backside. 2. Remove the three Phillips screws and two #6-32 Phillips screws. 3. Carefully remove the power distribution unit from the system chassis. Remove the Breaker Box 1. Remove the power breaker ...

  • Sun Microsystems 2000E - page 25

    Power Supply Installation 2-9 2 Filter Cable 1. Free the f ilter cable. a. On the inside of the power supply cage, cut the tie wrap and uncoil the cable. See Figure 2-8. b. Pass the cable connector through the rectangular hole in the power supply cage and allow it to hang. Figure 2-8 Freeing the Filter Cable 2.5.2.2 Power Supply Physical Installati ...

  • Sun Microsystems 2000E - page 26

    2-10 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 3. Shove the supply into the cavity — f lush against the sheet metal in the left-interior of the power supply cage. See Figure 2-9. Figure 2-9 Installing the Bottom Power Supply 4. Install six screws to secure the power supply to the power supply cage. Use screws Part No. 3 ...

  • Sun Microsystems 2000E - page 27

    Power Supply Installation 2-1 1 2 Figure 2-10 Installing the Power Supply Mounting Screws Screws (6 places) ...

  • Sun Microsystems 2000E - page 28

    2-12 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 5. Install the bottom cover panel. Position the panel Part No. 340-3190-xx and install 12 screws Part No. 240-1372-xx to secure the panel to the cabinet. See Figur e 2-1 1.g Figure 2-1 1 Installing the Bottom Cover Panel 2.5.2.3 Main Bus Bar Installation Install the main bus ...

  • Sun Microsystems 2000E - page 29

    Power Supply Installation 2-13 2 Figure 2-12 Installing the Main Bus Bar 2.5.2.4 Power Harness Installation Install the power harness, Part No. 530-2164-xx (comprised of four bus wires) to connect the two power supplies. 1. Orient the power harness as shown in Figure 2-13. 2. Connect the power harness to the top power supply . Push four spade conne ...

  • Sun Microsystems 2000E - page 30

    2-14 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 Figure 2-13 Installing Power Harness on the T op and Bottom Power Supply T erminal Blocks Figure 2-14 Installing the Main Bus Bar and the Power Harness P ower harness P ar t No . 530-2164-xx +12V +12V Return –12V –12V Return B D F H +12V +12V Return –12V –12V Return A ...

  • Sun Microsystems 2000E - page 31

    Power Supply Installation 2-15 2 2.5.2.5 Cabling Filter Cable, Breaker Box and AC Distribution Unit 1. Plug in the f ilter cable. Form a service loop in the cable and plug the connector into J2 (the top connector) on the power supply . See Figur e 2-15. 2. Replace the power breaker box. See Figure 2-15. c. Insert the f ilter cable service loop into ...

  • Sun Microsystems 2000E - page 32

    2-16 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 d. Place the breaker box against power supply cage. Align the captive screws with the bottom two holes in the top power supply . See Figur e 2-16. e. Loosely thread the two captive screws at the top of the breaker box into holes in the top power supply . f. Loosely thread two ...

  • Sun Microsystems 2000E - page 33

    Power Supply Installation 2-17 2 b. Replace the three Phillips screws and two #6-32 Phillips screws. c. Replace cables in connectors J2 and J3. 1. Plug in the three power cords: See Figure 2-17. a. Plug the main power cord into the AC distribution box J2 and the other end into breaker box J1 (bottom-right jack). b. Plug power cord Part Number 530-2 ...

  • Sun Microsystems 2000E - page 34

    2-18 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 2.5.2.6 Power Supply Sense Cable 1. Remove the jumper-connector from the power supply adapter board. Y ou will find this device plugged into the connector near est the outside edge of the cabinet. Remove it. See Figure 2-18. 2. Plug the sense cable for the bottom power supply ...

  • Sun Microsystems 2000E - page 35

    Power Supply Installation 2-19 2 2.5.2.7 Restore the System 1. Replace the power supply compartment EMI panel. See Figure 2-3. Position the panel against the cabinet and secure using 12 scr ews. Figure 2-19 Replacing the Power Supply Compartment EMI Panel Screws ...

  • Sun Microsystems 2000E - page 36

    2-20 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 2.6 Restarting the System Note – As the system starts up, watch for error messages fr om the POST diagnostic program. If a terminal is not alr eady part of the system, install a TTY terminal before continuing the start up. See the SP ARCcenter 2000 Installation manual for t ...

  • Sun Microsystems 2000E - page 37

    Power Supply Installation 2-21 2 Figure 2-20 Local/Remote Switch Location Caution – Never move the system cabinet or the expansion cabinets when system power is on. Excessive movement can cause catastrophic disk drive failure. Always power the system OFF befor e moving cabinets. Remote Local ! ...

  • Sun Microsystems 2000E - page 38

    2-22 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 6. W atch the terminal screen for any POST error messages. At the conclusion of testing, POST automatically configur es the system, omitting any devices that have failed diagnostics. After POST ends, the system will boot using the new configuration. If the middle front panel ...

  • Sun Microsystems 2000E - page 39

    Power Supply Installation 2-23 2 Figure 2-21 System Reset Switch 8. If the system displays “not responding” or “no carrier” messages, the Link Integrity T est may be set incorrectly . 2.7 Reading Boot Messages Use the boot software messages to verify the pr esence of options in the system. After POST completes the system self-test, a messag ...

  • Sun Microsystems 2000E - page 40

    2-24 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 Note – The following screen display is an example only . The actual message displayed on the screen will vary with the softwar e running on the system. Note – When a system is started for the first time, or if the master boar d is replaced, OBP will pr ompt you to select ...

  • Sun Microsystems 2000E - page 41

    Power Supply Installation 2-25 2 Figure 2-23 Power Supply Adapter Board LEDs T able 2-1 LED Status Indicators Location LED Condition Front panel Left LED (green) On — DC power supply is r eceiving AC current. Off — Ther e is no DC power . Middle LED (yellow) On — (first 60 seconds) Self tests ar e running. Off — (after self tests end) No ha ...

  • Sun Microsystems 2000E - page 42

    2-26 SP ARCserver 2000E Power Supply Installation Manual — April 1995 2 ...

  • Sun Microsystems 2000E - page 43

    A-1 Access A A.1 Removal Pr ocedures Remove panels to affor d access to the power supplies and related components. A.1.1 Opening the Hinged Door 1. Grasp the door at the upper-right corner and pull towards you f irmly . See Figure 1- 1. The door is secured closed by clips and ball-studs at the side opposite of the hinge. The door is released and sw ...

  • Sun Microsystems 2000E - page 44

    A-2 SP ARCserver 2000E Power Supply Installation Manual — April 1995 A Figure 1- 1 Opening the Hinged Door A.1.2 Removing the V ented Front Panels 1. Grasp the panel under the vent at one end and pull it outward approximately 1 inch (2-3 centimeters) to disengage the ball studs. See Figure 1-2. 2. Repeat this procedure at the opposite side to fre ...

  • Sun Microsystems 2000E - page 45

    Access A-3 A Figure 1-2 Removing the V ented Front Panels A.1.3 Removing the Side Panels T o remove the left and right side panels: 1. Loosen two slot-head captive screws near the panel base. 2. T ilt the panel bottom out. ...

  • Sun Microsystems 2000E - page 46

    A-4 SP ARCserver 2000E Power Supply Installation Manual — April 1995 A 3. Lift the panel up until free of the tabs at the top of the chassis. Set the panel aside . Figure 1-3 Removing the Side Panels A.1.4 Removing the EMI Shield The EMI shield is located behind the front panels. 1. Remove the Phillips screws securing the EMI shield to the chassi ...

  • Sun Microsystems 2000E - page 47

    Access A-5 A Figure 1-4 Removing the EMI Shield A.1.5 Rear Scr een Panel 1. Remove the two #10 Phillips screws securing the panel to the frame. See Figure 1-5. EMI shield #10 Phillips screws ...

  • Sun Microsystems 2000E - page 48

    A-6 SP ARCserver 2000E Power Supply Installation Manual — April 1995 A 2. T ilt the panel top out and lift it free of the chassis. Set the panel aside. There is a f lange on the bottom of the rear screen. Figure 1-5 Rear Screen Panel Removal A.2 Closing the System A.2.1 EMI Panel 1. Hold the panel by the handle at the top. Position the panel in t ...

  • Sun Microsystems 2000E - page 49

    Access A-7 A A.2.3 V ented Front Panel ♦ Place the panel against the chassis with ball studs aligned with catches on the panel. At both ends, tap or press the panel into place. A.2.4 Side Panels 1. Place the panel against the cabinet so the notches on the panel inside align with tabs at the chassis top. 2. Lower the panel into place and allow it ...

  • Sun Microsystems 2000E - page 50

    A-8 SP ARCserver 2000E Power Supply Installation Manual — April 1995 A ...

  • Sun Microsystems 2000E - page 51

    Revision History Revision Dash Date Comments 802-2700-10 -A April 1995 First Customer Ship ...

  • Sun Microsystems 2000E - page 52

    SP ARCserver 2000E Power Supply Installation Manual — April 1995 ...

  • Sun Microsystems 2000E - page 53

    Reader Comments We welcome your comments and suggestions to help improve this manual. Please let us know what you think about the SP ARCserver 2000E P ower Supply Installation Manual, part number 802-2700-10 . ■ The procedures were well documented. Strongly Strongly Not Agree Agree Disagree Disagree Applicable ❑❑❑❑❑ Comments ■ The tas ...

  • Sun Microsystems 2000E - page 54

    NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPL Y MAIL FIRST CLASS MAIL PERMIT NO . 1 MOUNT AIN VIEW , CA POST AGE WILL BE P AID BY ADDRESSEE SUN MICROSYSTEMS, INC. Attn: Manager, Hardware Publications MS MPK 14-101 2550 Garcia Avenue Mt. View, CA 94043-9850 ...

Manufacturer Sun Microsystems Category Power Supply

Documents that we receive from a manufacturer of a Sun Microsystems 2000E can be divided into several groups. They are, among others:
- Sun Microsystems technical drawings
- 2000E manuals
- Sun Microsystems product data sheets
- information booklets
- or energy labels Sun Microsystems 2000E
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sun Microsystems 2000E.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sun Microsystems 2000E, service manual, brief instructions and user manuals Sun Microsystems 2000E. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sun Microsystems 2000E.

A complete manual for the device Sun Microsystems 2000E, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sun Microsystems 2000E by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sun Microsystems 2000E.

A complete Sun Microsystems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sun Microsystems 2000E - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sun Microsystems 2000E, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sun Microsystems 2000E, that we can find in the current document
3. Tips how to use the basic functions of the device Sun Microsystems 2000E - which should help us in our first steps of using Sun Microsystems 2000E
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sun Microsystems 2000E
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sun Microsystems 2000E in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sun Microsystems 2000E?

Use the form below

If you did not solve your problem by using a manual Sun Microsystems 2000E, ask a question using the form below. If a user had a similar problem with Sun Microsystems 2000E it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)