Manual Franke FDW 908 IB XS

20 pages Not applicable
Download

Go to site of 20

Summary
  • Franke FDW 908 IB XS - page 1

    Instructions for use and installation Cooker Hood Istruzioni per l’uso e l’installazione Cappa Mode d’emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube Kullan ı m ve montaj talimatlar ı Davlumbaz FDW 908 IB XS GB IT FR DE TR ...

  • Franke FDW 908 IB XS - page 2

    2 2 INDEX RECOMMENDATIONS A ND SUGGEST IONS ..................................................................................................................... 3 CHARACTER ISTICS ............................................................................................................................................................. 4 INSTALLA ...

  • Franke FDW 908 IB XS - page 3

    EN 3 3 RECOMMENDATIONS AND SUGGESTIONS The Instruct ions for Us e apply to severa l versions of this appliance . Accordingly, you may find descrip tions of individu al features that do not apply to your sp ecific appl iance. INSTALLATION • The manufactur er will not b e held liabl e for any dam ages resulting from incorrec t or im- proper instal ...

  • Franke FDW 908 IB XS - page 4

    EN 4 4 CHARACTERISTICS Components Ref. Q.ty Product Components 1 1 Hood Canopy complete with: Controls, Light, Filters 2 1 Motor unit 3 1 Electric unit 4 1 Front Frame Ref. Q.ty Installation Components 7.1 2 Splashback Fixing Bracket 7.2 2 Hob Fixing Bracket 7.3 2 Side Bracket 12a 16 Screws 3.5 x 9.5 12b 6 Screws M4 x 8 12c 6 Screws 4 x 15 Q.ty Doc ...

  • Franke FDW 908 IB XS - page 5

    EN 5 5 Dimensions This Cooker hood can be used in conjunction with a Gas Cook Top having the following characteris tics: • Maximum power 12,4 kW • 5 fire like the picture 2,6 kW 5 kW 1,9 kW 1,9 kW 1 kW ...

  • Franke FDW 908 IB XS - page 6

    EN 6 6 INSTALLATION This Hood is set up to be f itt ed in side the kitchen unit in: • Ducting version : Evacuation to th e outside. • Recirculation version : Internal recirculation . Sequence of operations - Installation • Drilling the Support Surface and Fitting the Hood • Connections • Functional Check • Disposal of Packaging Drilling ...

  • Franke FDW 908 IB XS - page 7

    EN 7 7 7.2 12a 7.2 12a A Inserting the Hood Canopy into the support surface from bel ow • The Hood is built read y for front installation of the Mo- tor Unit. • If the kitchen unit is arr anged differently and the Motor Unit has to be fitted on the bac k, the Plug alr eady fitted on th e back of the Hoo d Can- opy must be removed and replaced a ...

  • Franke FDW 908 IB XS - page 8

    EN 8 8 7.2 12a 7.2 12a Inserting the Hood Canopy into the support surface from above • Insert the Brackets 7.2 , as indi- cated in the figure, into the slots provided and fix them with the screws 12a provided. • The Hood is built ready for front in- stallation of the Motor Unit. • If the kitchen unit is arranged differently and the Motor Unit ...

  • Franke FDW 908 IB XS - page 9

    EN 9 9 12c 12a 7.1 12a 7.1 Fixing the Lower Brackets • Screw the brac kets 7.1 to the front of the Hood Canopy using the screws 12a provided. • Before tightening the Brackets completel y, make all the adjustments to allow them to rest on the lower base of the worktop to avoid deformation of the upper brackets 7.2 as shown in the figure. • Wit ...

  • Franke FDW 908 IB XS - page 10

    EN 1 10 Fixing the Squaring Brackets • Screw the brackets 7.3 to the Hood Canopy using the screws 12b provided, without tightening completel y. • Using the screws 12c provided, fasten the oth er part of the brackets 7.3 either to the side walls of the unit or to the lower part of the cooker top. 12b 7.3 12b 7.3 12c • Tighten the scre ws 12c a ...

  • Franke FDW 908 IB XS - page 11

    EN 1 11 A Fixing the Motor Unit • Installation of the Motor Unit ( 1 ) at the front or rear must be de- cided according to the position of the Kitchen unit, making sure that the plug is properly positioned. • Subsequently, according to where the air outlet openin g has been created on the unit, the Motor Unit can be turned by 90° at a time so ...

  • Franke FDW 908 IB XS - page 12

    EN 1 12 Fixing the Electric Unit • Connect the Electric cables that come out of the lower right hand part of the Hood Canopy to the Connectors on the Electric unit. • Each cable connector has a corresponding connector on the Electric Unit, so take care not to make mistakes when connecting up. • Fix the Electric Unit to the Hood Canopy using t ...

  • Franke FDW 908 IB XS - page 13

    EN 1 13 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexib le or rigid pipe ø 150 or 120 mm, the choice of which is left to the insta ller. • To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. • Fix the pipe in ...

  • Franke FDW 908 IB XS - page 14

    EN 1 14 Warning..: Handle with care Fitting the Front element • Lift the mobile hood canopy (see paragraph on Use) by just a few centimetres. • To stop movement , simply press down on the mobile can- opy as it lifts up . Warning : Never block the slid- ing door when it is opening or closing, except during the op- erations required to fit the fr ...

  • Franke FDW 908 IB XS - page 15

    EN 1 15 Surround Suction Panel • Open the Hood Door (see USE). • Remove the 2 strips of adhesive tape fastening the panel during transport. ...

  • Franke FDW 908 IB XS - page 16

    EN 1 16 USE Control panel Button Function LED button A The bu tton only works when the door is open . Press B riefly = Turn s the Lights On/ Off at maximum intensi ty. Press and hold for 2 Seconds = Turns the Courtesy Lights On/Off. B Door Open or C losed Press briefly = Perfor ms a Reset of the Filter sat uration alarm. After 100 hours in operatio ...

  • Franke FDW 908 IB XS - page 17

    EN 1 17 REMOTE CONTROL (OPTIONAL) The appliance can be controll ed using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-AAA type (not included). • Do not place the rem ote control near to heat sour ces. • Used batteries must be disposed of in the proper manner. Remote control panel Warning ..: The remote ...

  • Franke FDW 908 IB XS - page 18

    EN 1 18 MAINTENANCE Cleaning the Comfort Panels • Open the Comfort Panel by pulling it at the top. • Unhook the security chain b y opening th e spring catch. • Disconnect the panel from the hood canopy. • The comfort panel m ust never be washed in the d ishwasher. • Clean the outside with a damp cloth and neu t ral deterg ent. • Clean t ...

  • Franke FDW 908 IB XS - page 19

    EN 1 19 Activated Charcoal Filter (Recirculation Versi o n) Can be washed in the dishwasher. It must be washed when button “C” lights up or at least once every 4 months, or more frequently if use is particu larly intense. Guaranteed to operate after washing for up to a maximum of 5 times be fore requiring replacement. The Alarm signal, if it ha ...

  • Franke FDW 908 IB XS - page 20

    991.0266.34 2_ver 4 Franke S.p.a. Via Pignolini,2 37019 Peschiera del Garda (VR) www.franke.it ...

Manufacturer Franke Category Exhaust hood

Documents that we receive from a manufacturer of a Franke FDW 908 IB XS can be divided into several groups. They are, among others:
- Franke technical drawings
- FDW 908 IB XS manuals
- Franke product data sheets
- information booklets
- or energy labels Franke FDW 908 IB XS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Franke FDW 908 IB XS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Franke FDW 908 IB XS, service manual, brief instructions and user manuals Franke FDW 908 IB XS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Franke FDW 908 IB XS.

A complete manual for the device Franke FDW 908 IB XS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Franke FDW 908 IB XS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Franke FDW 908 IB XS.

A complete Franke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Franke FDW 908 IB XS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Franke FDW 908 IB XS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Franke FDW 908 IB XS, that we can find in the current document
3. Tips how to use the basic functions of the device Franke FDW 908 IB XS - which should help us in our first steps of using Franke FDW 908 IB XS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Franke FDW 908 IB XS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Franke FDW 908 IB XS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Franke FDW 908 IB XS?

Use the form below

If you did not solve your problem by using a manual Franke FDW 908 IB XS, ask a question using the form below. If a user had a similar problem with Franke FDW 908 IB XS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)