Manual APC Smart-UPS

18 pages Not applicable
Download

Go to site of 18

Summary
  • APC Smart-UPS - page 1

    Operation Manual Smart-UPS ® Uninterruptible Power Supply 750/1000/1500/2200/3000 V A T ower 100/120/230 V ac 500 V A T ower 100 V ac ...

  • APC Smart-UPS - page 2

    ...

  • APC Smart-UPS - page 3

    1 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 500 V A to 3000 V A T ower is a high perform ance uninterruptible power supply (UPS). It provides pr otection for electronic equipment from utility power blackouts, brownouts, sags, and surges, sm ...

  • APC Smart-UPS - page 4

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 2 Product Overview Front p anel features Rear p a nel features 500 V A to 15 00 V A models  Display interface 500/750/1000/1 500 V A 2200/3000 V A  Bezel  Battery  Internal battery connector  USB port 500/750 V A 100 V ac 750 V A 120 V ac 750 V A 230 V ac  ...

  • APC Smart-UPS - page 5

    3 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Rear p a nel features 2200 V A and 30 00 V A models Inst allation For UPS installation information, refer to the Smart-UPS Installation Guide 750/1000/1500/2200/3000 V A 100/120/230 V ac, 500 V A 100 V ac T ower, that is included with the UPS. The Installation guide is a ...

  • APC Smart-UPS - page 6

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 4 Operation Connect Equipment Note: The UPS will char ge to 90% capacity in th e first four and a half hours of normal operation for the 2200/3000 V A 100 V ac model or the first three hours of normal operation for all other models . Do not expect full battery runtime capabi ...

  • APC Smart-UPS - page 7

    5 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Display Panel Using the display interface Use the U P and D OWN keys to scroll through th e main menu options. Press E NTER to view the sub-menus under each main menu option. Press E SCAPE to exit a sub-menu and return to a main menu. St andard menus The Standard menus a ...

  • APC Smart-UPS - page 8

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 6 Advanced menus The Advanced menus provid e additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. Menu General Functions St a t u s V iew detailed UPS information: • Operating Mode • Eff iciency • Load ...

  • APC Smart-UPS - page 9

    7 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Configuration UPS Settings St art-up Settings Configure these settings at initial start-up, using the di splay interface. As an a lternative, configuration can be performed using APC PowerChute ® software. Note: During start-up, use the display interface to configure th ...

  • APC Smart-UPS - page 10

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 8 Low T ransfer Point 100 V ac: 92 V ac 86 V ac - 92 V ac Set the transfer point lower if the utility voltage is chronically low and the connected equipment can tolerate this cond ition.This setting may also be a djusted using the power quality setting. Note: Use the Advance ...

  • APC Smart-UPS - page 11

    9 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Main Outlet Group and Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Grou p can be configured to independently turn of f, turn on, shut down, and reboot connecte d equipment. (These features are not available on the 500 V A or 750 V A units. ...

  • APC Smart-UPS - page 12

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 10 Customize the Main and Switched Outlet Groups Use the Configuration menus to change the Main Outlet Gro up and the Switched Ou tlet Group settings. Network Management Card Settings These settings are available only on units that have a Ne twork Management Card (NMC) and a ...

  • APC Smart-UPS - page 13

    11 Smart-UPS 750/1000/1 500/2200/3000 VA 1 00/120/2 30 Vac 500 VA 100 Vac Tower Emergency Power Off Overview The Emergency Power Off (EPO) optio n, is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r . Adhere to all national and l ...

  • APC Smart-UPS - page 14

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 12 T r oubleshooting Prob lem and Possible Cause Solution The UPS will not turn on or there is no output. The unit has not been turned on. Press the ON key once to turn on the UPS. The UPS is not connected to utility power . Be sure the power cabl e is securely connected to ...

  • APC Smart-UPS - page 15

    13 Smart-UPS 750/1000/1 500/2200/3000 VA 1 00/120/2 30 Vac 500 VA 100 Vac Tower Service If the unit requires service, do not retu rn it to the dealer . Follow these steps: 1. Review the T r ou bleshooting section of the manual to eliminate common problems. 2. If the problem persists, contact APC Cust omer Support through the APC W eb site, www .apc ...

  • APC Smart-UPS - page 16

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 14 Smart-UPS Factory W arranty LIMITED W ARRAN TY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from dat ...

  • APC Smart-UPS - page 17

    ...

  • APC Smart-UPS - page 18

    2/2012 990-3534C APC W orldwide Customer Support Customer support for this or any other APC product is available at no char ge in any of the follow ing ways: • V isit the APC W e b site to acce ss documents in the APC Knowledg e Base and to submit customer support requests. – www .apc.com (Corporate Headquarters) Connect to localized APC W eb s ...

Manufacturer APC Category Uninterruptible power supply (

Documents that we receive from a manufacturer of a APC Smart-UPS can be divided into several groups. They are, among others:
- APC technical drawings
- Smart-UPS manuals
- APC product data sheets
- information booklets
- or energy labels APC Smart-UPS
All of them are important, but the most important information from the point of view of use of the device are in the user manual APC Smart-UPS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals APC Smart-UPS, service manual, brief instructions and user manuals APC Smart-UPS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product APC Smart-UPS.

A complete manual for the device APC Smart-UPS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use APC Smart-UPS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of APC Smart-UPS.

A complete APC manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual APC Smart-UPS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the APC Smart-UPS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the APC Smart-UPS, that we can find in the current document
3. Tips how to use the basic functions of the device APC Smart-UPS - which should help us in our first steps of using APC Smart-UPS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with APC Smart-UPS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of APC Smart-UPS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning APC Smart-UPS?

Use the form below

If you did not solve your problem by using a manual APC Smart-UPS, ask a question using the form below. If a user had a similar problem with APC Smart-UPS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)