Manual Viking F20533 EN

16 pages 4.07 mb
Download

Go to site of 16

Summary
  • Viking F20533 EN - page 1

    Viking Range Corporation 111 Front Str eet Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com F20533 EN (093008J) ® Viking Installation Guide Pr ofessional Fr eestanding Dual Fuel Ranges ...

  • Viking F20533 EN - page 2

    IMPORT ANT– Read and Follow! 3 2 T able of Contents W arnings & Important Safety Instructions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

  • Viking F20533 EN - page 3

    IMPORT ANT– Read and Follow! 5 4 DANGER Gas leak hazard. T o avoid risk of personal injury or death; leak testing of the appliance must be conducted according to the manufacturer ’s instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution. • DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. DANG ...

  • Viking F20533 EN - page 4

    Dimensions 7 Dimensions 6 Dual Fuel 30”, 36”, 48” and 60” W . Ranges 3 5 - 7 / 8 ” ( 9 1 . 1 c m ) m i n . t o 3 7 ” ( 9 4 c m ) m a x . 1 ” ( 2 . 5 c m ) 2 9 - 7 / 8 ” ( 7 5 . 9 c m ) 3 5 - 7 / 8 ” ( 9 1 . 1 c m ) 4 7 - 7 / 8 ” ( 1 2 1 . 6 c m ) 6 0 ” ( 1 5 2 . 4 c m ) Note: Unit shown with standard island trim. Note: Unit sh ...

  • Viking F20533 EN - page 5

    Specifications 9 Specifications 8 Dual Fuel 30” and 36” W . Ranges Description 30” W . Models 36” W . Models Overall width 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) Overall height T o top of side trim - 35-7/8” (91.1 cm) min 37” (94.0 cm) max L egs adjust - 1-1/8” (2.9 cm) Overall depth from r ear T o end of side panel - 24-5/16” (61. ...

  • Viking F20533 EN - page 6

    4 2 ” m i n . ( 1 0 6 . 7 c m ) 1 3 ” m a x . ( 3 3 . 0 c m ) 6 ” m i n . ( 1 5 . 2 c m ) 1 8 ” m i n . ( 4 5 . 7 c m ) 3 / 8 ” ( 0 . 9 5 c m ) 3 6 ” ( 9 1 . 4 c m ) 2 9 - 7 / 8 ” ( 7 5 . 9 c m ) Clearance Dimensions (W ood/Composite Overlay) 11 Clearance Dimensions (Pr oximity to Cabinets) 10 • This range may be installed directly ...

  • Viking F20533 EN - page 7

    13 Electrical & Gas Requir ements Flexible Connections: If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a heavy-duty AGA design-certified flexible connector of at least 1/2” (1.3 cm) ID NPT (with suitable strain reliefs) in compliance with ANSI Z21.41 and Z21.69. 12 Electrical Re ...

  • Viking F20533 EN - page 8

    15 14 General Infor mation Installation READ AND FOLLOW ALL W ARNING AND CAUTION INFORMA TION WHEN INST ALLING THIS APPLIANCE. • Al l op en in gs in t he w al l be hi nd t he ap pl ia nc e and i n th e fl oo r un de r th e ap pl ia nc e mus t be s ea le d. • Do n ot o bs tr uct t he f lo w of c om bu st io n and ve nt il at ion a ir . Mo vin g, ...

  • Viking F20533 EN - page 9

    16 17 1 Remove access door . Electrical Connection (3-wir e) Note: If you have a 4-wire connection, see following section for 4-wire connection instructions. Use a 3-wire power supply cor d kit rated for 40 amps – 125/250 volts with closed loop terminals and marked for use with ranges. Do not use a GFI circuit. Wher e local codes do not permit gr ...

  • Viking F20533 EN - page 10

    19 18 1 2 Remove access door . Remove supply cord strain r elief bracket and three supply cor d mounting screws on the terminal block. Electrical Connection (4-wir e) Electrical Connection (3-wir e) (cont.) W ARNING Electrical shock hazard. T o avoid risk or electrical shock, personal injury or death; grounding product to the frame of the unit may ...

  • Viking F20533 EN - page 11

    21 20 1 2 Measure the four corners in cutout area to verify if flooring is level. For uneven or sloped floors, level unit with metal shims only , as the adjustment required may exceed the thread available in the leg. 3 4 3 /8 ” 3/8” (0 . 9 5 c m ) (0.95 cm) 3 /8 ” (0 . 9 5 c m ) Move unit into opening. Leveling/Adjustments/Alignment Electrica ...

  • Viking F20533 EN - page 12

    23 22 1 Me a sur emen t ( A ) Measurement (A) Mea su r emen t ( A ) 2 M e a s u r e m e n t ( A ) Measurement (A) + 1 / 2 ” +1/2” ( 1 . 3 c m ) (1.3 cm) M e a s u r e m e n t ( A ) + 1 / 2 ” ( 1 . 3 c m ) X X X Measure fr om floor to bottom of the anti-tip opening located on the back of range. This will be measurement (A). Lo c at e a nt i- t ...

  • Viking F20533 EN - page 13

    24 25 1 2 Reattach door to range. Open door completely . Reattach hinge trim. 3 4 Remove pins from hole in hinges. Close door . 5 If the door needs to be adjusted, loosen hinge trim screws located in step 2. Adjust the screws located between the door and kickplate using a 5/32” hex head allen wrench. After adjustment, tighten hinge trim scr ews. ...

  • Viking F20533 EN - page 14

    27 26 Only authorized replacement parts may be used in performing service on the appliance. All servicing should be referr ed to a qualified technician. Contact Viking Range Corporation, 1-888-VIKING1 (854-4641), for the nearest service parts distributor in your area or write to: VIKING RANGE CORPORA TION PREFERRED SERVICE 1803 Hwy 82W Greenwood, M ...

  • Viking F20533 EN - page 15

    29 28 N o t e s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

  • Viking F20533 EN - page 16

    31 30 ...

Manufacturer Viking Category Range

Documents that we receive from a manufacturer of a Viking F20533 EN can be divided into several groups. They are, among others:
- Viking technical drawings
- F20533 EN manuals
- Viking product data sheets
- information booklets
- or energy labels Viking F20533 EN
All of them are important, but the most important information from the point of view of use of the device are in the user manual Viking F20533 EN.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Viking F20533 EN, service manual, brief instructions and user manuals Viking F20533 EN. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Viking F20533 EN.

Similar manuals

A complete manual for the device Viking F20533 EN, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Viking F20533 EN by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Viking F20533 EN.

A complete Viking manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Viking F20533 EN - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Viking F20533 EN, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Viking F20533 EN, that we can find in the current document
3. Tips how to use the basic functions of the device Viking F20533 EN - which should help us in our first steps of using Viking F20533 EN
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Viking F20533 EN
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Viking F20533 EN in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Viking F20533 EN?

Use the form below

If you did not solve your problem by using a manual Viking F20533 EN, ask a question using the form below. If a user had a similar problem with Viking F20533 EN it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)